Percutaneous autologous venous valve transplantation: short-term feasibility study in an ovine model
Resumo:
BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.
Resumo:
BACKGROUND AND PURPOSE: The purpose of the study was to compare efficacy and potential complications of 2 commercially available devices for mechanical thromboembolectomy. METHODS: Devices were tested in an established animal model allowing the use of routine angiography catheters and thrombectomy devices. Radio-opaque thrombi were used for visualization of thrombus-device interaction during angiography. The Merci Retrieval System and the Catch Thromboembolectomy System were assessed each in 10 vessel occlusions. For every occluded vessel up to 5 retrieval attempts were performed. RESULTS: Sufficient recanalization was achieved with the Merci Retriever in 90% of occlusions, and with the Catch device recanalization was achieved in 70% of occlusions. Recanalization at the first attempt occurred significantly more often with the Merci Retriever compared to the Catch device (OR, 21; 95% CI, 1.78-248.11). Consequently, significantly more attempts (P=0.02) had to be performed with the Catch device; therefore, time to recanalization was longer. Thrombus fragmentations during retrieval were caused more often by the Catch device compared to the Merci Retriever (OR, 15.6; 95% CI, 1.73-140.84), resulting in a higher distal embolization rate. During retrieval both devices lost thrombotic material at the tip of the guide catheter, which was then aspirated in most cases. CONCLUSIONS: Both distal devices are effective for thromboembolectomy. To avoid loss of thrombotic material and distal embolization, the use of large luminal balloon guide catheters and aspiration during retrieval seems to be mandatory. The design of the Merci Retriever appears to be more efficient during thrombus mobilization and retrieval with less fragmentation compared to the Catch Thromboembolectomy System.
Resumo:
OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
Resumo:
The aim of the study was to conduct a long-term follow-up on the stability of the hard tissues after bilateral sagittal split osteotomy (BSSO) with rigid internal fixation (RIF)to set back the mandible and to compare it with that of mandibular advancement performed by the same team of surgeons and with the same examination protocol. Seventeen consecutive patients (6 females and 11 males) could be re-examined 12.7 years (T5) after surgery. The previous examinations were before surgery (T1), 5 days (T2), and 6.6 (T3) and 14.4 (T4) months after surgery. Lateral cephalograms were traced by hand, digitized, and evaluated with the Dentofacial Planner software program. The x-axis for the system of co-ordinates ran through sella (point zero) and the line nasion-sella-line minus 7 degrees. The program determined the x- and y-values of each variable and the usual angles and distances. The effects of treatment were determined with Wilcoxon matched pairs, signed ranks test, with Bonferroni adjustment, and the relationship between variables with Spearman rank correlation coefficient. Relapse at point B was 0.94 mm or 15 per cent and at pogonion 1.46 mm or 21 per cent of the initial setback at T5. Relapse was mainly short-term (T4-T2), 13 per cent for point B and 17 per cent for pogonion. Gender correlated significantly with relapse (T5-T2) at point B (P = 0.002) and pogonion (P = 0.021), i.e. females in contrast to males showed further distalization of the mandible instead of relapse. No correlations were seen for age or the amount of surgical setback. The long-term results in mandibular setback patients were more stable when compared with the mandibular advancement patients examined previously. The initial soft tissue profile, the initial growth direction, and the remodelling processes of the hard tissues must be considered as reasons for long-term relapse. Growth direction positively influenced the long-term results in females: further distalization of the mandible occurred.
Resumo:
AIM: This pilot study seeks to determine whether contact system activation (CSA) occurs in human sepsis patients and to characterise blood levels of the 47kD light chain of high-molecular weight kininogen (47kD HK). METHODS: Six consecutive patients with clinical suspicion of sepsis were evaluated on days 1, 2, 3 and 6-8 for 47kD HK blood levels expressed in U/ml of whole blood and as percent of total HK. 47kD HK was measured in whole blood by quantitative immunoblot analysis. RESULTS: On study day 1 or 2, analysis of 47kD HK in U/ml of whole blood identified CSA in 3/6 patients.When 47kD HK levels were expressed as percent of total HK, 4/6 patients were identified with CSA before day 3. The degree of CSA as assayed by the presence of 47kD HK correlated with the severity of the systemic inflammatory syndrome (SIRS), i.e. mean CSA increased progressively from basal levels in healthy controls (0.08 U/ml or 10.4%) to patients without SIRS (0.10 U/ml or 15.1%), to patients with sepsis (0.12 U/ml or 15.0%), and finally to patients in a combined category of severe sepsis and septic shock (0.13 U/ml or 17.4%). CONCLUSION: CSA, defined by increased 47kD HK, occurred early on in the course of sepsis in a subset of sepsis patients. 47kD HK levels, an indicator of bradykinin release, correlated with sepsis severity. Future larger studies will need to evaluate the role of 47kD HK as a biomarker for both prognosis and treatment response in human sepsis..
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
OBJECTIVE: To review the epidemiology of facial fractures in children and to analyze whether it has changed over time. STUDY DESIGN: Retrospective review of records of children aged < or = 15 years diagnosed for fracture during 2 10-year periods. RESULTS: A total of 378 children were diagnosed with fractures, 187 in 1980-1989 and 191 in 1993-2002. The proportion of children with mandibular fractures decreased by 13.6 percentage-points from the first period to the second, whereas the proportion of patients with midfacial fractures increased by 18.7 percentage-points. Assault as a causative factor increased by 5.5 percentage-points, almost exclusively among children aged 13-15 years, with a high percentage (23.5%). CONCLUSIONS: Recognition of a change in fracture patterns over time is probably due to the increased use of computerized tomographic scanning.
Resumo:
OBJECTIVE: To evaluate safety of same-day administration of verteporfin and ranibizumab. METHODS: Prospective, open-label, multicentre study; patients with predominantly classic (n = 13) or occult (n = 19) choroidal neovascularisation secondary to age-related macular degeneration received standard-fluence verteporfin at baseline and months 3, 6 and 9, based on fluorescein angiography (FA). Ranibizumab 0.5 mg was administered at baseline and months 1, 2 and 3. MAIN OUTCOME MEASURE: The incidence of severe vision loss (best-corrected visual acuity (BCVA) loss > or = 30 letters; primary safety assessment). RESULTS: No severe vision loss due to ocular inflammation or uveitis occurred. One patient had moderate vision loss (BCVA loss > or = 15 letters). Three patients had mild/moderate uveitis. Two serious ocular adverse events occurred (retinal pigment epithelial tear and moderate BCVA decrease). No systemic adverse events occurred. At 9 months, all lesions were inactive with no recurrent leakage on FA and optical coherence tomography; macular oedema and subretinal fluid resolved. The mean BCVA measured at 2 m improved by 6.9 letters at 4 months and 2.4 letters at 9 months. CONCLUSIONS/APPLICATION TO CLINICAL PRACTICE: Same-day verteporfin and ranibizumab was safe and not associated with severe vision loss or severe ocular inflammation. Lesions stabilized, with minimal treatment required after month 3.
Resumo:
OBJECTIVES Application of the recently developed optical method based on the monitoring of the specular reflection intensity to study the protective potential of the salivary pellicle layer against early enamel erosion. METHODS The erosion progression was compared between two treatment groups: enamel samples coated by the 15 h-in vitro-formed salivary pellicle layer (group P, n=90) and the non-coated enamel surfaces (control group C, n=90). Different severity of the erosive impact was modelled by the enamel incubation in 1% citric acid (pH=3.6) for 2, 4, 8, 10 or 15 min. Erosion quantification was performed by the optical method as well as by the microhardness and calcium release analyses. RESULTS Optical assessment of the erosion progression showed erosion inhibition by the in vitro salivary pellicle in short term acidic treatments (≤ 4 min) which was also confirmed by microhardness measurements proving significantly less (p<0.05) enamel softening in the group P at 2 and 4 min of erosion compared to the group C. SEM images demonstrated less etched enamel interfaces in the group P at short erosion durations as well. CONCLUSIONS Monitoring of the specular reflection intensity can be successfully applied to quantify early erosion progression in comparative studies. In vitro salivary pellicle (2h) provides erosion inhibition but only in short term acidic exposures. CLINICAL SIGNIFICANCE The proposed optical technique is a promising tool for the fast and non-invasive erosion quantification in clinical studies.
Resumo:
BACKGROUND: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. METHODS: We studied 4 alerts: hemoglobin A1c > or =15%, positive hepatitis C antibody, prostate-specific antigen > or =15 ng/mL, and thyroid-stimulating hormone > or =15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. RESULTS: Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84). CONCLUSIONS: Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.
Resumo:
Fusion of nonmetastatic murine melanoma K1735 C19H cells with metastatic human melanoma A375 C15N cells resulted in a hybrid (termed H7) which was highly metastatic in a nude mouse model. The H7 hybrid retained chromosome 17 as the sole intact human chromosome in the cell. A lung bioassay showed that the K1735 C19H cells were present in the lungs of nude mice with s.c. tumors, yet at 6-weeks after tumor resection, no cells remained in the lung and therefore did not form lung metastases. Examination of various phenotypic properties such as in vivo and in vitro growth demonstrated that phenotypically the H7 hybrid was most like the K1735 C19H cell line except for its metastatic ability. In contrast the H7 hybrid cells containing single or multiple copies of human chromosome 17 with a point mutation at codon 249 (arg-gly) of the p53 gene, readily formed lung metastases. A plasmid containing the human p53 from the H7 hybrid and four other contructs with mutations at codon 143 (val-arg), 175 (arg-his), 249 (arg-ser) and 273 (arg-his) were transfected into K1735 C19H cells. K1735 C19H cells expressing human p53 genes with mutations at codons 249, both the arg-ser mutation and the mutation from the H7 hybrid and 273 produced significantly more lung metastases.^ In vitro assays demonstrated that responses to various cytotoxic and DNA damaging agents varied with the presence of mutant p53 and with the type of agent used. When cultured in mouse lung-conditioned medium, the K1735 C19H cell line was growth-inhibited, while cells containing a mutant human p53 (either on the whole chromosome 17, as in the H7 hybrid cells or from a stably transfected construct) were growth stimulated. Western blot analysis of lung-conditioned media derived from either 6-month or 15-month old mice has detected high levels of soluble Fas ligand in the medium from older animals. Comparison of the levels of Fas receptor on the K1735 C19H cell line and the H7 hybrid were almost identical, but 50% of the K1735 C19H cells were killed in the presence of anti-Fas antibody as opposed to 7% of the H7 hybrid cells. The growth-inhibitory effects of the lung-conditioned medium on the K1735 C19H cells were abrogated by coculture with Fas-Fc, which competes with the Fas ligand for receptor binding. Growth-inhibition of the K1735 C19H was 54% when cultured in 60 $\mu$g/0.2 ml lung-conditioned medium and a control Fc, with only 9% inhibition in 60 $\mu$g/0.2 ml lung-conditioned medium and Fas-Fc. Growth of the H7 cells and K1735 C19H cells transfected with various mutant human p53 genes were unchanged by the presence of either the control Fc or the Fas-Fc. This indicates that the presence of human chromosome 17, and mutant p53 in part protects the cells from Fas:Fas ligand induced apoptosis, and allows the growth of lung metastases. ^
Resumo:
PURPOSE: Surgical site infections (SSI) are associated with increased costs and length of hospital stay, readmission rates, and mortality. The aim of this study was to identify risk factors for SSI in patients undergoing laparoscopic cholecystectomy. METHODS: Analysis of 35,432 laparoscopic cholecystectomies of a prospective multicenter database was performed. Risk factors for SSI were identified among demographic data, preoperative patients' history, and operative data using multivariate analysis. RESULTS: SSIs after laparoscopic cholecystectomy were seen in 0.8 % (n = 291) of the patients. Multivariate analysis identified the following parameters as risk factors for SSI: additional surgical procedure (odds ratio [OR] 4.0, 95 % confidence interval [CI] 2.2-7.5), age over 55 years (OR 2.4 [1.8-3.2]), conversion to open procedure (OR 2.6 [1.9-3.6]), postoperative hematoma (OR 1.9 [1.2-3.1]), duration of operation >60 min (OR 2.5 [1.7-3.6], cystic stump insufficiency (OR 12.5 [4.2-37.2]), gallbladder perforation (OR 6.2 [2.4-16.1]), gallbladder empyema (OR 1.7 [1.1-2.7]), and surgical revision (OR 15.7 [10.4-23.7]. SSIs were associated with a significantly prolonged hospital stay (p < 0.001), higher postoperative mortality (p < 0.001), and increased rate of surgical revision (p < 0.001). CONCLUSIONS: Additional surgical procedure was identified as a strong risk factor for SSI after laparoscopic cholecystectomy. Furthermore, operation time >60 min, age >55 years, conversion to open procedure, cystic stump insufficiency, postoperative hematoma, gallbladder perforation, gallbladder empyema, or surgical revision were identified as specific risk factors for SSI after laparoscopic cholecystectomy.
Resumo:
Up to 10% of all breast and ovarian cancers are attributable to mutations in cancer susceptibility genes. Clinical genetic testing for deleterious gene mutations that predispose to hereditary breast and ovarian cancer (HBOC) syndrome is available. Mutation carriers may benefit from following high-risk guidelines for cancer prevention and early detection; however, few studies have reported the uptake of clinical genetic testing for HBOC. This study identified predictors of HBOC genetic testing uptake among a case series of 268 women who underwent genetic counseling at The University of Texas M. D. Anderson Cancer Center from October, 1996, through July, 2000. Women completed a baseline questionnaire that measured psychosocial and demographic variables. Additional medical characteristics were obtained from the medical charts. Logistic regression modeling identified predictors of participation in HBOC genetic testing. Psychological variables were hypothesized to be the strongest predictors of testing uptake—in particular, one's readiness (intention) to have testing. Testing uptake among all women in this study was 37% (n = 99). Contrary to the hypotheses, one's actual risk of carrying a BRCA1 or BRCA2 gene mutation was the strongest predictor of testing participation (OR = 15.37, CI = 5.15, 45.86). Other predictors included religious background, greater readiness to have testing, knowledge about HBOC and genetic testing, not having female children, and adherence to breast self-exam. Among the subgroup of women who were at ≥10% risk of carrying a mutation, 51% (n = 90) had genetic testing. Consistent with the hypotheses, predictors of testing participation in the high-risk subgroup included greater readiness to have testing, knowledge, and greater self-efficacy regarding one's ability to cope with test results. Women with CES-D scores ≥16, indicating the presence of depressive symptoms, were less likely to have genetic testing. Results indicate that among women with a wide range of risk for HBOC, actual risk of carrying an HBOC-predisposing mutation may be the strongest predictor of their decision to have genetic testing. Psychological variables (e.g., distress and self-efficacy) may influence testing participation only among women at highest risk of carrying a mutation, for whom genetic testing is most likely to be informative. ^
Resumo:
Human Papillomavirus (HPV) is the most common sexually transmitted disease in the United States. Although HPV prevalence is high in the United States, there are a limited number of research studies that focus on Hispanics, who have higher incidence rates of cervical cancer than their non-Hispanic counterparts. The HPV vaccine introduced in 2006 may offer a feasible solution to the issues surrounding high prevalence of HPV. Due to the high prevalence of HPV infection among adolescents and young adults it has been suggested that HPV vaccination begin prior to onset sexual activity and focus on non-sexually active adolescents and pre-adolescents. Consequently, it has become increasingly important to assess knowledge and awareness of HPV in order to develop effective intervention strategies. This pilot study evaluated the knowledge and health beliefs of Hispanic parents regarding HPV and the HPV vaccine using a newly developed questionnaire based on the constructs of the Health Belief Model. The sample was recruited from an ob-gyn office in El Paso, Texas. Descriptive data show that the majority of the sample was female (94.1%), Hispanic (76.5%), Catholic (64.7%), and had at least a high school education (55.9%). Chi-square analysis revealed that the following variables differed amongst parents who intended to vaccinate their child against HPV and those who did not: religion (p=0.038), perceived severity item "HPV infections are easily treated" (p=0.052), perceived benefits item "It is better to vaccinate a child against an STI before they become sexually active" (p=0.014) and perceived barriers item "The HPV vaccine may have serious side effects that could harm my child" (p=0.004). Univariate logistic regression indicated that religion (OR = 4.8, CI: 1.04, 21.8) and "The HPV vaccine may have serious side effects that could harm my child" (OR = 15.9, CI: 1.73, 145.8) were significant predictors of parental intention to vaccinate. Multivariate logistic regression, using backwards elimination, indicated that religion (OR = 7.7, CI: 1.25, 47.8) and "The HPV vaccine may have serious side effects that may harm my child" (OR = 7.6, CI: 1.15, 50.2) were the best predictive variables for parental intention to vaccinate. ^
Resumo:
The purpose of this study was to assess the accuracy and precision of airborne volatile organic compound (VOC) concentrations measured using passive air samplers (3M 3500 organic vapor monitors) over extended sampling durations (9 and 15 days). A total of forty-five organic vapor monitor samples were collected at a State of Texas air monitoring site during two different sampling periods (July/August and November 2008). The results of this study indicate that for most of the tested compounds, there was no significant difference between long-term (9 or 15 days) sample concentrations and the means of parallel consecutive short-term (3 days) sample concentrations. Biases of 9 or 15-day measurements vs. consecutive 3-day measurements showed considerable variability. Those compounds that had percent bias values of <10% are suggested as acceptable for long-term sampling (9 and 15 days). Of the twenty-one compounds examined, 10 compounds are classified as acceptable for long-term sampling; these include m,p-xylene, 1,2,4-trimethylbenzene, n-hexane, ethylbenzene, benzene, toluene, o-xylene, d-limonene, dimethylpentane and methyl tertbutyl ether. The ratio of sampling procedure variability relative to variability within days was approximately 1.89 for both sampling periods for the 3-day vs. 9-day comparisons and approximately 2.19 for both sampling periods for the 3-day vs. 15-day comparisons. Considerably higher concentrations of most VOCs were measured during the November sampling period compared to the July/August period. These differences may be a result of varying meteorological conditions during these two time periods, e.g., the differences in wind direction, and wind speed. Further studies are suggested to further evaluate the accuracy and precision of 3M 3500 organic vapor monitors over extended sampling durations. ^