965 resultados para Gas chromatography - GC-FID


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gas chromatographic/mass spectrometric method is described for the detection of clenbuterol residues in liver, muscle, urine and retina. Tissue samples are first digested using protease and any clenbuterol present is extracted using a simple liquid/liquid extraction procedure. The dried extracts are then derivatized using methylboronic acid and the derivatives are subjected to gas chromatography/mass spectrometry on a magnetic sector instrument. The detection limit of the assay is 0.05 ng g-1 clenbuterol in liver, muscle or urine using a 10 g sample size, and 4 ng g-1 in retina using a 0.5 g sample size. The assay is made very specific by using selected ion monitoring of three ions at a resolution of 3500 and by ion ratio measurements. The precision and reproducibility of the assay are enhanced by the use of a deuterated internal standard, with a typical coefficient of variation of 3%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to analyse the Brazilian savanna forest from a Legal Reserve (LR) area from a perspective of conservation, reservoir of organic carbon and medicinal biomass for a prospective use of native medicinal plants. An ethnobotanical and ethnopharmacological survey was carried out close to a community settled in the rural area in the south of Tocantins, being selected 9 of the most cited species (cajuí- Anacardium othonianum; inharé-Brosimum gaudichaudii; jatobá-Hymenaeae courbaril; jenipapo-Genipa americana, aroeira-Myracrodruon urundeuva; negramina-Siparuna guianensis; barbatimão- Stryphnodendron obovatum; assa peixe-Vernonia brasiliana, embaúba-Cecropia pachystachya). Crude foliar extracts were subjected to a preliminary phytochemical prospection and triage of secondary metabolites with antimicrobial activity of potential interest in health and familiar agriculture. Phenolic compounds, terpenes and flavonoids were detected in the extracts of most species, which suggests the presence of antimicrobial, antioxidant and anti-insect activities. It was evident the need to better know the LR as a reservoir of medicinal biomass in an area under ecological tension where 35% (610ha) of the property is LR and should be protected by law. Therefore, a forest inventory of live woody species was performed using the allometric or indirect method. This identified a rare remnant of Semidecidual Seasonal Forest amidst the largest world savannah, the Cerrado biome. An analysis of the forest average productivity per basal area (m².ha), aerial live biomass (ton.ha-1) and carbon stock was carried out. The forest fragment was considered relatively rich in species and diversity, although showing signs of disturbance and dominance by a few species. Its horizontal structure suggests biotic regeneration conditions. It is an important reservoir of medicinal plants. Of the families (57.5%) presenting medicinal species, 19 from a total of 33 are represented in the area and contain 44% (27) of the total species (61) and 63% (432) of the total individuals catalogued. Medicinal species have ecological importance for the equilibrium of the local flora and represent 80% of the 10 species with higher Importance Value Index (IVI): Tetragastris altissima, Chrysophyllum marginatum, Oenocarpus distichus, Sclerolobium paniculatum, Simarouba versicolor, Alibertia macrophylla, Siparuna guianensis, Maprounea guianensis, Licania parvifolia e Physocalymma scaberrimum. Medicinal productivity was high for this type of phytophysionomy: 183,2 ton. ha-1 of biomass and 91,51 ton. ha-1 of carbon representing 66% of the total biomass and carbon of this Cerrado forest. From this stage S. guianensis (Siparunaceae) was selected for performing bioassays in order to verify its biological activity against microorganisms of health and agricultural relevance. This is a native aromatic medicinal plant recommended as priority for conservation, with local popular medicinal validation and availability of medicinal feedstock (3300 Kg.ha-1), with the foliar fraction giving 38Kg/ha of crude extract and 5L/ha of essential oil. Foliar crude extracts and essential oil were obtained and tested in vitro using a disk diffusion bioassay. Different concentrations of these natural products were tested against gram-positive bacteria (Staphylococcus aureus ATCC 29213), gram-negative bacteria (Escherichia coli ATCC 25922 and ATCC 35218; Pseudomonas aeruginosa ATCC 10145) and fungi (Candida albicans ATCC 6258 e Fusarium oxysporum). The essential oil inhibited the growth of S. aureus in its crude concentration (380μg.mL-1), as well as diluted to half (190μg.mL-1) and a quarter strength (95μg.mL-1). It’s likely that such action is due to sesquiterpenes major components, such as bisabolol and bisabolene (10.35%), measured by gas chromatography (GC-MS, GC-FID). Extracts did not exhibit any antimicrobial activity against the microorganisms tested. The native medicinal plants prospective market is an alternative that favours the conservation of biodiversity while generating benefits for the development of sustainable family productive activities within local ecosystems instead of the current inappropriate uses. This strengthens conservation policies of Legal Reserve in rural settlements and is in agreement with public policy on global warming and climate changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a comparison of adaptations of the QuEChERS (quick, easy, cheap, effective, rugged and safe) approach for the determination of 14 organochlorine pesticide (OCP) residues in strawberry jam by concurrent use of gas chromatography (GC) coupled to electron capture detector (ECD) and GC tandem mass spectrometry (GC-MS/MS). Three versions were tested based on the original QuEChERS method. The results were good (overall average of 89% recoveries with 15% RSD) using the ultrasonic bath at five spiked levels. Performance characteristics, such as accuracy, precision, linear range, limits of detection (LOD) and quantification (LOQ), were determined for each pesticide. LOD ranged from 0.8 to 8.9 microg kg-1 ; LOQ was in the range of 2.5–29.8 microg kg- 1; and calibration curves were linear (r2>0.9970) in the whole range of the explored concentrations (5–100 microg kg- 1). The LODs of these pesticides were much lower than the maximum residue levels (MRLs) allowed in Europe for strawberries. The method was successfully applied to the quantification of OCP in commercially available jams. The OCPs were detected lower than the LOD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combined gas chromatography and mass spectrometry has been used to identify unknown residues in soils (especially pesticides). The effect of U.V. light on DDT and linuron and quantitative estimation of elemental sulfur in different soils has also been carried out.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the determination of volatile organic compounds (VOCs) in recycled polyethylene terephthalate and high-density polyethylene using headspace sampling by solid-phase microextraction and gas chromatography coupled to mass spectrometry detection is presented. This method was used to evaluate the efficiency of cleaning processes for VOC removal from recycled PET. In addition, the method was also employed to evaluate the level of VOC contamination in multilayer packaging material containing recycled HDPE material. The optimisation of the extraction procedure for volatile compounds was performed and the best extraction conditions were found using a 75 mu m carboxen-polydimethylsiloxane (CAR-PDMS) fibre for 20 min at 60 degrees C. The validation parameters for the established method were linear range, linearity, sensitivity, precision (repeatability), accuracy (recovery) and detection and quantification limits. The results indicated that the method could easily be used in quality control for the production of recycled PET and HDPE. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography - mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L(-1) and 0.02 mg kg(-1), respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.