903 resultados para GLANCING ANGLE DEPOSITION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:The QRS-T angle correlates with prognosis in patients with heart failure and coronary artery disease, reflected by an increase in mortality proportional to an increase in the difference between the axes of the QRS complex and T wave in the frontal plane. The value of this correlation in patients with Chagas heart disease is currently unknown.Objective:Determine the correlation of the QRS-T angle and the risk of induction of ventricular tachycardia / ventricular fibrillation (VT / VF) during electrophysiological study (EPS) in patients with Chagas disease.Methods:Case-control study at a tertiary center. Patients without induction of VT / VF on EPS were used as controls. The QRS-T angle was categorized as normal (0-105º), borderline (105-135º) or abnormal (135-180º). Differences between groups for continuous variables were analyzed with the t test or Mann-Whitney test, and for categorical variables with Fisher's exact test. P values < 0.05 were considered significant.Results:Of 116 patients undergoing EPS, 37.9% were excluded due to incomplete information / inactive records or due to the impossibility to correctly calculate the QRS-T angle (presence of left bundle branch block and atrial fibrillation). Of 72 patients included in the study, 31 induced VT / VF on EPS. Of these, the QRS-T angle was normal in 41.9%, borderline in 12.9% and abnormal in 45.2%. Among patients without induction of VT / VF on EPS, the QRS-T angle was normal in 63.4%, borderline in 14.6% and abnormal in 17.1% (p = 0.04). When compared with patients with normal QRS-T angle, those with abnormal angle had a fourfold higher risk of inducing ventricular tachycardia / ventricular fibrillation on EPS [odds ratio (OR) 4; confidence interval (CI) 1.298-12.325; p = 0.028]. After adjustment for other variables such as age, ejection fraction (EF) and QRS size, there was a trend for the abnormal QRS-T angle to identify patients with increased risk of inducing VT / VF during EPS (OR 3.95; CI 0.99-15.82; p = 0.052). The EF also emerged as a predictor of induction of VT / VF: for each point increase in EF, there was a 4% reduction in the rate of sustained ventricular arrhythmia on EPS.Conclusions:Changes in the QRS-T angle and decreases in EF were associated with an increased risk of induction of VT / VF on EPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projecte de recerca elaborat a partir d’una estada al Departament d’Enginyeria Química del Massachusetts Institute of Technology entre abril i octubre del 2006. S’ha dissenyat i sintetitzat uns nous films polimèrics, amb aplicacions en l’àmbit de l’enginyeria de teixits, utilitzant la tècnica anomenada iCVD (initiated Chemical Vapor Deposition), prèviament desenvolupada pel grup receptor. Es tracta d’uns hidrogels superficials de gruix controlable, que incorporen un monòmer fluorat, el qual s’havia estudiat extensament en el grup d’origen. Aquest monòmer es caracteritza per reaccionar molt fàcilment amb pèptids, de manera que aquests queden units covalentment a la superfície. Diferents estratègies pel desenvolupament d’aquests copolímers han estat avaluades, tant des del punt de vista purament sintètic com de la pròpia aplicació. Les condicions de polimerització han estat optimitzades i els hidrogels s’han caracteritzat químicament per tècniques espectroscòpiques (FTIR, XPS), i físicament per angle de contacte i el·lipsometria. D’aquesta manera, s’ha estudiat la capacitat dels hidrogels d’absorbir aigua i alhora augmentar el seu gruix, depenent de la quantitat d’agent reticulant introduït i de la incorporació del nou monòmer. A continuació, s’han optimitzat les condicions de reacció d’aquestes superfícies amb pèptids que incorporen una molècula fluorescent, la qual permet detectar fàcilment per microscòpia de fluorescència si la reacció ha tingut lloc. Una vegada la plataforma ha estat posada a punt, s’han iniciat assajos cel·lulars tant amb fibroblasts embriònics de ratolí com amb cèl·lules humanes umbilicals. Els resultats preliminars suggereixen una morfologia diferent de les cèl·lules segons si es cultiven sobre films modificats amb pèptids que promouen l’adhesió cel·lular o sobre les seves seqüències permutades no actives. Però, el més interessant és que també s’han observat certes diferències depenent si els films contenen el component hidrogel o no, fet que suggeriria un paper actiu d’aquests noves superfícies en el comportament cel·lular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called 'virtual CT' to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland-Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (-0.22-0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the maximum temperature elevation in the phantom (7% relative drop). Without any correction, the maximum temperature was down 6 °C (43% relative drop). We have developed an approach that allows for a reconstruction of a virtual CT dataset from MRI to perform phase correction in TcMRgFUS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In addition to prosthetic rehabilitation, maxillary defects can also be surgically reconstructed. Soft-tissue reconstruction employs a radial forearm or latissimus dorsi muscle flap, while bony reconstruction can be achieved using a fibula, iliac crest, or scapular flap. Reconstruction using a scapular flap is further divided into two subgroups: the traditional scapular flap with the circumflex scapular artery as the donor vessel and the scapular angle flap with the angular artery originating from the thoracodorsal artery as the donor vessel. MATERIALS AND METHODS: We report on four patients who underwent successful reconstruction with a free scapular angle flap between 2009 and 2011, following maxillary resection due to malignancy. RESULTS: Vertical positioning of the scapular angle flap enables reconstruction of the facial contour, whereas its horizontal alignment and microvascular anastomosis makes a bony reconstruction of the hard palate possible. CONCLUSIONS: The versatility, low rate of donor site morbidity and shape of the scapular angle flap--which resembles that of the hard palate--render it ideal for plastic reconstruction. The suitability of bone quality for dental rehabilitation with implants is a topic of controversial discussion. The scapular angle flap represents an alternative to obturator prosthesis for the reconstruction of maxillary defects ≥ grade I according to Okay et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBACKGROUND: KRAB-ZFPs (Krüppel-associated box domain-zinc finger proteins) are vertebrate-restricted transcriptional repressors encoded in the hundreds by the mouse and human genomes. They act via an essential cofactor, KAP1, which recruits effectors responsible for the formation of facultative heterochromatin. We have recently shown that KRAB/KAP1 can mediate long-range transcriptional repression through heterochromatin spreading, but also demonstrated that this process is at times countered by endogenous influences.METHOD: To investigate this issue further we used an ectopic KRAB-based repressor. This system allowed us to tether KRAB/KAP1 to hundreds of euchromatic sites within genes, and to record its impact on gene expression. We then correlated this KRAB/KAP1-mediated transcriptional effect to pre-existing genomic and chromatin structures to identify specific characteristics making a gene susceptible to repression.RESULTS: We found that genes that were susceptible to KRAB/KAP1-mediated silencing carried higher levels of repressive histone marks both at the promoter and over the transcribed region than genes that were insensitive. In parallel, we found a high enrichment in euchromatic marks within both the close and more distant environment of these genes.CONCLUSION: Together, these data indicate that high levels of gene activity in the genomic environment and the pre-deposition of repressive histone marks within a gene increase its susceptibility to KRAB/KAP1-mediated repression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are numerous variants of cutaneous tumors involving the eyelids. Tumors of a different nature may at times be observed simultaneously in the same area of the eyelid. A clinicopathologic case of a 36-year-old male patient with 2 different cutaneous tumors at the nasal part of the left eyelid is reported. One was a nodular tumor on the inner canthus with a pearly appearance; the other had a papillomatous pattern. After surgical removal, the histopathological study of the tumors disclosed a typical basal cell carcinoma and a squamous cell papilloma. Both tumors can be commonly observed on the eyelids and surgical excision cured the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gliomas are routinely graded according to histopathological criteria established by the World Health Organization. Although this classification can be used to understand some of the variance in the clinical outcome of patients, there is still substantial heterogeneity within and between lesions of the same grade. This study evaluated image-guided tissue samples acquired from a large cohort of patients presenting with either new or recurrent gliomas of grades II-IV using ex vivo proton high-resolution magic angle spinning spectroscopy. The quantification of metabolite levels revealed several discrete profiles associated with primary glioma subtypes, as well as secondary subtypes that had undergone transformation to a higher grade at the time of recurrence. Statistical modeling further demonstrated that these metabolomic profiles could be differentially classified with respect to pathological grading and inter-grade conversions. Importantly, the myo-inositol to total choline index allowed for a separation of recurrent low-grade gliomas on different pathological trajectories, the heightened ratio of phosphocholine to glycerophosphocholine uniformly characterized several forms of glioblastoma multiforme, and the onco-metabolite D-2-hydroxyglutarate was shown to help distinguish secondary from primary grade IV glioma, as well as grade II and III from grade IV glioma. These data provide evidence that metabolite levels are of interest in the assessment of both intra-grade and intra-lesional malignancy. Such information could be used to enhance the diagnostic specificity of in vivo spectroscopy and to aid in the selection of the most appropriate therapy for individual patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En aquest projecte s'ha estudiat la posada a punt d’un equip comercial ALD per a l’obtenció de capes primes d'alúmina a escala nanomètrica utilitzant vapor d’aigua i TMA com a precursors. Per tal de comprovar a bondat de les receptes experimentals aportades pel fabricant així com comprovar alguns aspectes de la teoria ALD s’han realitzat una sèrie de mostres variant els diferents paràmetres experimentals, principalment la temperatura de deposició, el nombre de cicles, la durada del cicle i el tipus de substrat. Per a la determinació dels gruixos nanomètrics de les capes i per tant dels ritmes de creixement s’ha utilitzat la el·lipsometria, una de les poques tècniques no destructives capaç de mesurar amb gran precisió gruixos de capes o interfases de pocs àngstroms o nanòmetres. En una primera etapa s'han utilitzat els valors experimentals donats pel fabricant del sistema ALD per determinar el ritme de creixement en funció de la temperatura de dipòsit i del numero de cicles, en ambdós casos sobre diversos substrats. S'ha demostrat que el ritme de creixement augmenta lleugerament en augmentar la temperatura de dipòsit, tot i que amb una variació petita, de l'ordre del 12% en variar 70ºC la temperatura de deposició. Així mateix s'ha demostrat la linealitat del gruix amb el número de cicles, tot i que no s’observa una proporcionalitat exacta. En una segona etapa s'han optimitzat els paràmetres experimentals, bàsicament els temps de purga entre pols i pols per tal de reduir considerablement les durades dels experiments realitzats a relativament baixes temperatures. En aquest cas s’ha comprovat que es mantenien els ritmes de creixement amb una diferencia del 3,6%, 4,8% i 5,5% en optimitzar el cicles en 6,65h, 8,31h, o 8,33h, respectivament. A més, per una d'aquestes condicions s’ha demostrat que es mantenia l’alta conformitat de les capes d’alúmina. A més, s'ha realitzat un estudi de l'homogeneïtat del gruix de les capes en tota la zona de dipòsit del reactor ALD. S’ha demostrat que la variació en gruix de les capes dipositades a 120ºC és com a màxim del 6,2% en una superfície de 110 cm2. Confirmant l’excepcional control de gruixos de la tècnica ALD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The in situ deposition of zinc oxide on gold nanoparticles in aqueous solution has been here successfully applied in the field of fingermark detection on various non-porous surfaces. In this article, we present the improvement of the multimetal deposition, an existing technique limited up to now to non-luminescent results, by obtaining luminescent fingermarks with very good contrast and details. This is seen as a major improvement in the field in terms of selectivity and sensitivity of detection, especially on black surfaces.

Relevância:

20.00% 20.00%

Publicador: