980 resultados para Fire conditions


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We synthesize recent results from lake-sediment studies of Holocene fire-climate-vegetation interactions in Alaskan boreal ecosystems. At the millennial time scale, the most robust feature of these records is an increase in fire occurrence with the establishment of boreal forests dominated by Picea mariana: estimated mean fire-return intervals decreased from ≥300 yrs to as low as ∼80 yrs. This fire-vegetation relationship occurred at all sites in interior Alaska with charcoal-based fire reconstructions, regardless of the specific time of P. mariana arrival during the Holocene. The establishment of P. mariana forests was associated with a regional climatic trend toward cooler/wetter conditions. Because such climatic change should not directly enhance fire occurrence, the increase in fire frequency most likely reflects the influence of highly flammable P. mariana forests, which are more conducive to fire ignition and spread than the preceding vegetation types (tundra, and woodlands/forests dominated by Populus or Picea glauca). Increased lightning associated with altered atmospheric circulation may have also played a role in certain areas where fire frequency increased around 4000 calibrated years before present (BP) without an apparent increase in the abundance of P. mariana. When viewed together, the paleo-fire records reveal that fire histories differed among sites in the same modern fire regime and that the fire regime and plant community similar to those of today became established at different times. Thus the spatial array of regional fire regimes was non-static through the Holocene. However, the patterns and causes of the spatial variation remain largely unknown. Advancing our understanding of climate-fire-vegetation interactions in the Alaskan boreal biome will require a network of charcoal records across various ecoregions, quantitative paleoclimate reconstructions, and improved knowledge of how sedimentary charcoal records fire events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the people: a revelation.--The conditions that hold among us.--As time deals with nations.--As to government.--A great people's movement.--Public utilities for the public good.--Labour and its uniting power.--Agencies whereby we shall secure the people's greatest good.--The great nation.--The life of the higher beauty and power.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"Compliments of American Eagle Fire Insurance Co., the Continental Insurance Company, Fidelity-Phenix Fire Insurance Co"

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fire Service personnel face risk on a daily basis, frequently working in extremely hazardous conditions—and the severity of the danger faced can fluctuate rapidly. The Fire Service has therefore become extremely experienced at managing dynamic risks. The aim of this article is to review techniques used in the UK fire service to attenuate the effects of risk and to discuss these with respect to organisations which experience dynamic risk in other fields—even if in less dramatic conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research is concerned with the application of the computer simulation technique to study the performance of reinforced concrete columns in a fire environment. The effect of three different concrete constitutive models incorporated in the computer simulation on the structural response of reinforced concrete columns exposed to fire is investigated. The material models differed mainly in respect to the formulation of the mechanical properties of concrete. The results from the simulation have clearly illustrated that a more realistic response of a reinforced concrete column exposed to fire is given by a constitutive model with transient creep or appropriate strain effect The assessment of the relative effect of the three concrete material models is considered from the analysis by adopting the approach of a parametric study, carried out using the results from a series of analyses on columns heated on three sides which produce substantial thermal gradients. Three different loading conditions were used on the column; axial loading and eccentric loading both to induce moments in the same sense and opposite sense to those induced by the thermal gradient. An axially loaded column heated on four sides was also considered. The computer modelling technique adopted separated the thermal and structural responses into two distinct computer programs. A finite element heat transfer analysis was used to determine the thermal response of the reinforced concrete columns when exposed to the ISO 834 furnace environment. The temperature distribution histories obtained were then used in conjunction with a structural response program. The effect of the occurrence of spalling on the structural behaviour of reinforced concrete column is also investigated. There is general recognition of the potential problems of spalling but no real investigation into what effect spalling has on the fire resistance of reinforced concrete members. In an attempt to address the situation, a method has been developed to model concrete columns exposed to fire which incorporates the effect of spalling. A total of 224 computer simulations were undertaken by varying the amounts of concrete lost during a specified period of exposure to fire. An array of six percentages of spalling were chosen for one range of simulation while a two stage progressive spalling regime was used for a second range. The quantification of the reduction in fire resistance of the columns against the amount of spalling, heating and loading patterns, and the time at which the concrete spalls appears to indicate that it is the amount of spalling which is the most significant variable in the reduction of fire resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

East-West trade has grown rapidly since the sixties, stimulating a parallel expansion in the literature on the subject. An extensive review of this literature shows how: (i) most of the issues involved have at their source the distinctions between East and West in political ideology and/or economic management, and (ii) there has been a tendency to keep theoretical and practical perspectives on the subject too separate. This thesis demonstrates the importance of understanding the fundamental principles implied in the first point, and represents an attempt to bridge the gap identified in the second. A detailed study of the market for fire fighting equipment in Eastern Europe is undertaken in collaboration with a medium-sized company, Angus Fire Armour Limited. Desk research methods are combined with visits to the market to assess the potential for the company's products, and recommendations for future strategy are made. The case demonstrates the scope and limitations of various research methods for the East European market, and a model for market research relevant to all companies is developed. Tne case study highlights three areas largely neglected in the literature: (i) the problems of internal company adaptation to East European conditions; (ii) the division of responsibility between foreign trade organisations; and (iii) bribery and corruption in East-West trade. Further research into the second topic - through a survey of 36 UK exporters - and the third - through analysis of publicised corruption cases - confirms the representativeness of the Angus experience, and reflects on the complexity of the Bast European import process, which does not always function as is commonly supposed. The very complexity of the problems confronting companies reaffirms the need to appreciate the principles underlying the subject, while the detailed analysis into questions of, originally, a marketing nature, reveals wider implications for East-West trade and East-West relations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While the existence of black carbon as part of dissolved organic matter (DOM) has been confirmed, quantitative determinations of dissolved black carbon (DBC) in freshwater ecosystem and information on factors controlling its concentration are scarce. In this study, stream surface water samples from a series of watersheds subject to different burn frequencies in Konza Prairie (Kansas, USA) were collected in order to determine if recent fire history has a noticeable effect on DBC concentration. The DBC levels detected ranged from 0.04 to 0.11 mg L−1, accounting for ca. 3.32 ± 0.51% of dissolved organic carbon (DOC). No correlation was found between DBC concentration and neither fire frequency nor time since last burn. We suggest that limited DBC flux is related to high burning efficiency, possibly greater export during periods of high discharge and/or the continuous export of DBC over long time scales. A linear correlation between DOC and DBC concentrations was observed, suggesting the export mechanisms determining DOC and DBC concentrations are likely coupled. The potential influence of fire history was less than the influence of other factors controlling the DOC and DBC dynamics in this ecosystem. Assuming similar conditions and processes apply in grasslands elsewhere, extrapolation to a global scale would suggest a global grasslands flux of DBC on the order of 0.14 Mt carbon year−1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within the marl prairie grasslands of the Florida Everglades, USA, the combined effects of fire and flooding usually lead to very significant changes in tree island structure and composition. Depending on fire severity and post-fire hydroperiod, these effects vary spatially and temporally throughout the landscape, creating a patchy post-fire mosaic of tree islands with different successional states. Through the use of the Normalized Difference Vegetation Index (NDVI) and three predictor variables (marsh water table elevation at the time of fire, post-fire hydroperiod, and tree island size), along with logistic regression analysis, we examined the probability of tree island burning and recovering following the Mustang Corner Fire (May to June 2008) in Everglades National Park. Our data show that hydrologic conditions during and after fire, which are under varying degrees of management control, can lead to tree island contraction or loss. More specifically, the elevation of the marsh water table at the time of the fire appears to be the most important parameter determining the severity of fire in marl prairie tree islands. Furthermore, in the post-fire recovery phase, both tree island size and hydroperiod during the first year after the fire played important roles in determining the probability of tree island recovery, contraction, or loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fire, which affects community structure and composition at all trophic levels, is an integral component of the Everglades ecosystem (Wade et al. 1980; Lockwood et al. 2003). Without fire, the Everglades as we know it today would be a much different place. This is particularly true for the short-hydroperiod marl prairies that predominate on the eastern and western flanks of Shark River Slough, Everglades National Park (Figure 1). In general, fire in a tropical or sub-tropical grassland community favors the dominance of C4 grasses over C3 species (Roscoe et al. 2000; Briggs et al. 2005). Within this pyrogenic graminoid community also, periodic natural fires, together with suitable hydrologic regime, maintain and advance the dominance of C4 vs C3 graminoids (Sah et al. 2008), and suppress the encroachment of woody stems (Hanan et al. 2009; Hanan et al. unpublished manuscript) originating from the tree islands that, in places, dominate the landscape within this community. However, fires, under drought conditions and elevated fuel loads, can spread quickly throughout the landscape, oxidizing organic soils, both in the prairie and in the tree islands, and, in the process, lead to shifts in vegetation composition. This is particularly true when a fire immediately precedes a flood event (Herndon et al. 1991; Lodge 2005; Sah et al. 2010), or if so much soil is consumed during the fire that the hydrologic regime is permanently altered as a result of a decrease in elevation (Zaffke 1983).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within Big Cypress National Preserve (BICY), oak-dominated forests and woodlands as well as tropical and temperate hardwood hammocks are integral components of the landscape and are biodiversity hotpots for both flora and fauna. These broadleaved forest communities serve as refugia for many of the Preserve’s wildlife species during prolonged flooding and fires. However, both prolonged flooding and severe fires, which are important and necessary disturbance vectors within this landscape, can have deleterious effects on these forested communities. This is particularly true in the case of fires, which under extreme conditions associated with drought and elevated fuel loads, can burn through these forested communities consuming litter and understory vegetation and top killing most, if not all, of the trees present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Once the preserve of university academics and research laboratories with high-powered and expensive computers, the power of sophisticated mathematical fire models has now arrived on the desk top of the fire safety engineer. It is a revolution made possible by parallel advances in PC technology and fire modelling software. But while the tools have proliferated, there has not been a corresponding transfer of knowledge and understanding of the discipline from expert to general user. It is a serious shortfall of which the lack of suitable engineering courses dealing with the subject is symptomatic, if not the cause. The computational vehicles to run the models and an understanding of fire dynamics are not enough to exploit these sophisticated tools. Too often, they become 'black boxes' producing magic answers in exciting three-dimensional colour graphics and client-satisfying 'virtual reality' imagery. As well as a fundamental understanding of the physics and chemistry of fire, the fire safety engineer must have at least a rudimentary understanding of the theoretical basis supporting fire models to appreciate their limitations and capabilities. The five day short course, "Principles and Practice of Fire Modelling" run by the University of Greenwich attempt to bridge the divide between the expert and the general user, providing them with the expertise they need to understand the results of mathematical fire modelling. The course and associated text book, "Mathematical Modelling of Fire Phenomena" are aimed at students and professionals with a wide and varied background, they offer a friendly guide through the unfamiliar terrain of mathematical modelling. These concepts and techniques are introduced and demonstrated in seminars. Those attending also gain experience in using the methods during "hands-on" tutorial and workshop sessions. On completion of this short course, those participating should: - be familiar with the concept of zone and field modelling; - be familiar with zone and field model assumptions; - have an understanding of the capabilities and limitations of modelling software packages for zone and field modelling; - be able to select and use the most appropriate mathematical software and demonstrate their use in compartment fire applications; and - be able to interpret model predictions. The result is that the fire safety engineer is empowered to realise the full value of mathematical models to help in the prediction of fire development, and to determine the consequences of fire under a variety of conditions. This in turn enables him or her to design and implement safety measures which can potentially control, or at the very least reduce the impact of fire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental and numerical study of turbulent fire suppression is presented. For this work, a novel and canonical facility has been developed, featuring a buoyant, turbulent, methane or propane-fueled diffusion flame suppressed via either nitrogen dilution of the oxidizer or application of a fine water mist. Flames are stabilized on a slot burner surrounded by a co-flowing oxidizer, which allows controlled delivery of either suppressant to achieve a range of conditions from complete combustion through partial and total flame quenching. A minimal supply of pure oxygen is optionally applied along the burner to provide a strengthened flame base that resists liftoff extinction and permits the study of substantially weakened turbulent flames. The carefully designed facility features well-characterized inlet and boundary conditions that are especially amenable to numerical simulation. Non-intrusive diagnostics provide detailed measurements of suppression behavior, yielding insight into the governing suppression processes, and aiding the development and validation of advanced suppression models. Diagnostics include oxidizer composition analysis to determine suppression potential, flame imaging to quantify visible flame structure, luminous and radiative emissions measurements to assess sooting propensity and heat losses, and species-based calorimetry to evaluate global heat release and combustion efficiency. The studied flames experience notable suppression effects, including transition in color from bright yellow to dim blue, expansion in flame height and structural intermittency, and reduction in radiative heat emissions. Still, measurements indicate that the combustion efficiency remains close to unity, and only near the extinction limit do the flames experience an abrupt transition from nearly complete combustion to total extinguishment. Measurements are compared with large eddy simulation results obtained using the Fire Dynamics Simulator, an open-source computational fluid dynamics software package. Comparisons of experimental and simulated results are used to evaluate the performance of available models in predicting fire suppression. Simulations in the present configuration highlight the issue of spurious reignition that is permitted by the classical eddy-dissipation concept for modeling turbulent combustion. To address this issue, simple treatments to prevent spurious reignition are developed and implemented. Simulations incorporating these treatments are shown to produce excellent agreement with the experimentally measured data, including the global combustion efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Doutoramento em Engenharia Florestal - Instituto Superior de Agronomia - UL

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado Mediterranean Forestry and Natural Resources Management - Instituto Superior de Agronomia - UL