994 resultados para Financial strength


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we report the adsorption of phenylalanine (Phe) on Magnesium Aluminum Layered Double Hydroxides (Mg-Al-CO(3)-LDH) at two different temperatures (298 and 310 K) and under two distinct ionic strength conditions (with and without the addition 0.1 M of NaCl). The adsorption isotherms exhibit the same profile in all conditions, and they only differ in the amount of removed Phe. At lower ionic strength, the isotherms are almost identical at both temperatures, except for the last points, where the increase in temperature causes a decrease in the amount of adsorbed Phe. An increase in ionic strength results in a decrease in Phe adsorption. The electrokinetic potential decreases as the amount of adsorbed Phe increases, and only positive values are observed. This indicates that the surface of the adsorbent is not totally neutralized and suggests that more Phe could be removed by adsorption. The presence of Phe on the solid is confirmed by FTIR spectra, which present the specific bands assigned to Phe. The hydrophobicity of the amino acid probably contributes to its extraction, thus enabling the removal of a great amount of Phe. In conclusion, LDH is potentially applicable in the removal of Phe from wastewater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Strength of Weak Parties The aim of this article is to fill some gaps in research on the Brazilian electoral arena. The current literature, by neglecting the study of party organization, ends up overlooking fundamental questions for understanding how the electoral process works. This study addressed two questions: How do Brazilian parties work? What is the impact of party organization on a party`s decision to launch or withhold a candidate in a given election? We intend to show that the parties have more life than many studies on our political system tend to show. This partisan life helps understand one of the central aspects of the electoral arena, that is, how pre-election coordination occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this paper is to study the respiratory muscle strength by evaluating the maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP) and lung volume before and 3 and 6 months after adenotonsillectomy. This is an interventional, before and after trial. It was set at the Department of Otolaryngology. University of Sao Paulo, School of Medicine. We included 29 children (6-13 years old), both genders, consecutively recruited from the waiting list for adenotonsillectomy. Children were submitted to maximal inspiratory pressures (MIP), maximal expiratory pressure (MEP) evaluation using an analog manovacuometer, lung volume, using incentive expirotometer and thoracic and abdominal perimeter using a centimeter tape. Children were evaluated in 3 different moments: 1 week before and 3 and 6 months after surgery. Results: MIP improved significantly 3 months (p < 0.001) after adenotonsillectomy and MEP did not change (p = 1). There were increases in lung volume (p = 000), chest (p = 0.017) and abdominal perimeter (p = 0.05). Six months after surgery, all parameters improved. MIP (p = 0), MEP (p = 0), lung volume (p = 0.02), chest (p = 0.034) and abdominal perimeter (p = 0.23). Conclusion: This study suggests that there was an improvement in respiratory muscular strength, once there was a significant improvement in maximal inspiratory pressure, lung volume and other parameters after adenotonsillectomy. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protrusion of the abdominal wall secondary to abdominoplasty may occur in patients with weakness of the aponeurotic structures. The anterior layer of the rectus abdominis muscle consists of fibers that are transverse rather than vertical. Based on this anatomical feature, vertical sutures are suggested for the correction of diastasis recti, since they include a greater amount of fascial fibers and thus would be more resistant to tensile strength than horizontal ones. The anterior layers of the rectus abdominis muscles of 15 fresh cadavers were dissected. Two vertical lines were marked on each side of the linea alba, corresponding to the site where plication is usually performed in abdominoplasties. Three abdominal levels were evaluated: the supraumbilical, umbilical, and infraumbilical levels. A simple suture was placed in the vertical direction in one group and in the horizontal direction in the other group, at each of the three levels previously described. These sutures were connected to a dynamometer, which was pulled medially toward the linea alba until rupture of the aponeurosis occurred. The mean strength required to rupture the aponeurotic structures in which the vertical sutures had been placed was greater than for the horizontal ones (p < 0.0001). The vertical suture of the rectus abdominis sheaths was stronger than the horizontal suture because of the more transversal arrangement of its aponeurotic fibers. Thus, routine use of the vertical suture in plications of the aponeurosis of the rectus abdominis muscles is suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Studies have investigated the influence of neuromuscular electrostimulation on the exercise/muscle capacity of patients with heart failure (HF), but the hemodynamic overload has never been investigated. The aim of our study was to evaluate the heart rate (HR), systolic and diastolic blood pressures in one session of strength exercises with and without neuromuscular electrostimulation (quadriceps) in HF patients and in healthy subjects. Methods: Ten (50% male) HF patients and healthy subjects performed three sets of eight repetitions with and without neuromuscular electrostimulation randomly, with one week between sessions. Throughout, electromyography was performed to guarantee the electrostimulation was effective. The hemodynamic variables were measured at rest, again immediately after the end of each set of exercises, and during the recovery period. Results: Systolic and diastolic blood pressures did not change during each set of exercises among either the HF patients or the controls. Without electrostimulation: among the controls, the HR corresponding to the first (85 +/- 13 bpm, p = 0.002), second (84 +/- 10 bpm, p < 0.001), third (89 +/- 17, p < 0.001) sets and recuperation (83 +/- 16 bpm, p = 0.012) were different compared to the resting HR (77 bpm). Moreover, the recuperation was different to the third set (0.018). Among HF patients, the HR corresponding to the first (84 +/- 9 bpm, p = 0.041) and third (84 +/- 10 bpm, p = 0.036) sets were different compared to the resting HR (80 +/- 7 bpm), but this increase of 4 bpm is clinically irrelevant to HF. With electrostimulation: among the controls, the HR corresponding to the third set (84 +/- 9 bpm) was different compared to the resting HR (80 +/- 7 bmp, p = 0.016). Among HF patients, there were no statistical differences between the sets. The procedure was well tolerated and no subjects reported muscle pain after 24 hours. Conclusions: One session of strength exercises with and without neuromuscular electrostimulation does not promote a hemodynamic overload in HF patients. (Cardiol J 2011; 18,1: 39-46)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to determine the reliability of isokinetic strength and endurance testing in the ankle joints of patients with intermittent claudication. Twenty-three patients with peripheral artery disease (PAD) and symptoms of intermittent claudication participated in the study. Isokinetic strength and endurance testing of the ankle joint were performed in symptomatic and asymptomatic legs on 3 separate days. Intraclass coefficient correlation of peak torque (PT) and total work (TW) ranged from 0.77 to 0.92 and 0.89 to 0.96, respectively. PT and TW increased significantly and similarly in both legs from day 1 to day 2 (PT: +42 +/- 84% in the symptomatic leg and +33 +/- 51% in the asymptomatic leg, p < 0.05;TW: +38 +/- 26% in the symptomatic leg and +26 +/- 50% in the asymptomatic leg, p < 0.05). In conclusion, isokinetic strength and endurance testing in the ankle joints of patients with PAD presents reliability coefficients ranging from 0.77 to 0.96. However, strength and endurance increased between the first and the other test sessions performed on separate days, suggesting that two test sessions are necessary for the accurate evaluation of strength and endurance in patients with PAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of the opaque layer firing temperature and mechanical and thermal cycling on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr). The hypotheses were that higher opaque layer temperatures increase the metal/ceramic bond strength and that aging reduces the bond strength. Materials and Methods: Metallic frameworks (25 x 3 x 0.5 mm(3); ISO 9693) (N = 60) were cast in Co-Cr and airborne-particle abraded (Al(2)O(3): 150 mu m) at the central area of the frameworks (8 x 3 mm(2)) and divided into three groups (N = 20), according to the opaque layer firing temperature: Gr1 (control)-900 degrees C; Gr2-950 degrees C; Gr3-1000 degrees C. The opaque ceramic (Opaque, Vita Zahnfabrick, Bad Sackingen, Germany) was applied, and the glass ceramic (Vita Omega 900, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). While half the specimens from each group were randomly tested without aging (water storage: 37 degrees C/24 hours), the other half were mechanically loaded (20,000 cycles; 50 N load; distilled water at 37 degrees C) and thermocycled (3000 cycles; 5 degrees C to 55 degrees C, dwell time: 30 seconds). After the flexural strength test, failure types were noted. The data were analyzed using 2-way ANOVA and Tukey`s test (alpha = 0.05). Results: Gr2 (19.41 +/- 5.5 N) and Gr3 (20.6 +/- 5 N) presented higher values than Gr1 (13.3 +/- 1.6 N) (p = 0.001). Mechanical and thermal cycling did not significantly influence the mean flexural strength values (p > 0.05). Increasing the opaque layer firing temperature improved the flexural bond strength values (p < 0.05). The hypotheses were partially accepted. Conclusion: Increasing of the opaque layer firing temperature improved the flexural bond strength between ceramic fused to Co-Cr alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burke TN, Franc, a FJR, de Meneses SRF, Cardoso VI, Marques AP: Postural control in elderly persons with osteoporosis: Efficacy of an intervention program to improve balance and muscle strength: A randomized controlled trial. Am J Phys Med Rehabil 2010; 89: 549-556. Objective: To assess the efficacy of an exercise program aiming to improve balance and muscular strength, for postural control and muscular strength of women with osteoporosis. Design: Sample consisted of 33 women with osteoporosis, randomized into one of two groups: intervention group, in which exercises for balance and improvement of muscular strength of the inferior members were performed for 8 wks (n = 17, age 72.8 +/- 3.6 yrs); control group, which was women not practicing exercises (n = 16, age 74.4 +/- 3.7 yrs). At baseline and after 8 wks of treatment, postural control was assessed using a force plate (Balance Master, Neurocom), and muscular strength during ankle dorsiflexion, knee extension, and flexion was assessed by dynamometry. Results: Adherence to the program was 82%. When compared with the control group, individuals in the intervention group significantly improved the center of pressure velocity (P = 0.02) in the modified clinical test of sensory interaction for balance test, center of pressure velocity (P < 0.01), and directional control (P < 0.01) in limits of stability test, isometric force during ankle dorsiflexion (P = 0.01), knee extension (P < 0.01), and knee flexion (P < 0.01). Conclusions: Balance and strength exercises are effective in improving postural control and lower-limb strength in elderly women with osteoporosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The financial and economic analysis of investment projects is typically carried out using the technique of discounted cash flow (DCF) analysis. This module introduces concepts of discounting and DCF analysis for the derivation of project performance criteria such as net present value (NPV), internal rate of return (IRR) and benefit to cost (B/C) ratios. These concepts and criteria are introduced with respect to a simple example, for which calculations using MicroSoft Excel are demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The study was designed to evaluate the effects of strength training (ST) on the bone mineral density (BMD) of postmenopausal women without hormone replacement therapy. Method: Subjects were randomized into untrained (UN) or trained (TR) groups. The TR group exercised three ST sessions per week for 24 weeks, and body composition, muscular strength, and BMD of the lumbar spine and femur neck were evaluated. Results: Body weight, mass index, and fat percentage were lower after 24 weeks only in the TR group (p < .05). SR also improved the one repetition maximum test in 46% and 39% of upper and lower limbs, respectively. The percentage of demineralization was higher in the UN group than in the TR group at the lumbar spine and femoral neck (p < .05). Discussion: Results indicated that 24 weeks of ST improved body composition parameters, increased muscular strength, and preserved BMD in postmenopausal women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we study the possible microscopic origin of heavy-tailed probability density distributions for the price variation of financial instruments. We extend the standard log-normal process to include another random component in the so-called stochastic volatility models. We study these models under an assumption, akin to the Born-Oppenheimer approximation, in which the volatility has already relaxed to its equilibrium distribution and acts as a background to the evolution of the price process. In this approximation, we show that all models of stochastic volatility should exhibit a scaling relation in the time lag of zero-drift modified log-returns. We verify that the Dow-Jones Industrial Average index indeed follows this scaling. We then focus on two popular stochastic volatility models, the Heston and Hull-White models. In particular, we show that in the Hull-White model the resulting probability distribution of log-returns in this approximation corresponds to the Tsallis (t-Student) distribution. The Tsallis parameters are given in terms of the microscopic stochastic volatility model. Finally, we show that the log-returns for 30 years Dow Jones index data is well fitted by a Tsallis distribution, obtaining the relevant parameters. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods. Metallic frameworks (25 mm x 3 mm x 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 mu m aluminum oxide at the central area of the frameworks (8 mm x 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: I mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 degrees C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 degrees C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 degrees C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey`s test (alpha = 0.05). Results. The mean flexural strength values for the ceramic-gold alloy combination (55 +/- 7.2MPa) were significantly higher than those of the ceramic-Ti cp combination (32 +/- 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 +/- 6.6 and 53 +/- 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 +/- 6.8 and 29 +/- 6.8 MPa, respectively) compared to the control group (58 +/- 7.8 and 39 SA MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey`s test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance. Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.