898 resultados para FULL-THICKNESS DEFECTS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a model for permeation in oxide coated gas barrier films. The model accounts for diffusion through the amorphous oxide lattice, nano-defects within the lattice, and macro-defects. The presence of nano-defects indicate the oxide layer is more similar to a nano-porous solid (such as zeolite) than silica glass with respect to permeation properties. This explains why the permeability of oxide coated polymers is much greater, and the activation energy of permeation much lower, than values expected for polymers coated with glass. We have used the model to interpret permeability and activation energies measured for the inert gases (He, Ne and Ar) in evaporated SiOx films of varying thickness (13-70 nm) coated on a polymer substrate. Atomic force and scanning electron microscopy were used to study the structure of the oxide layer. Although no defects could be detected by microscopy, the permeation data indicate that macro-defects (>1 nm), nano-defects (0.3-0.4 nm) and the lattice interstices (<0.3 nm) all contribute to the total permeation. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three different lubricating greases and their bleed and base oils were compared in terms of film thickness in a ball-on-disc test rig through optical interferometry. The theoretical values calculated according to Hamrock's equation are in close agreement with the base oil film thickness measurements, which validates the selected experimental methodology. The grease and bleed oil film thickness under fully flooded lubrication conditions presented quite similar behaviour and levels. Therefore, the grease film thickness under full film conditions might be predicted using their bleed oil properties, namely the viscosity and pressure-viscosity coefficient. The base and bleed oil lubricant parameter LP are proportional to the measured film thickness. A relationship between grease and the corresponding bleed oil film thickness was evidenced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Invariant integrals are derived for nematic liquid crystals and applied to materials with small Ericksen number and topological defects. The nematic material is confined between two infinite plates located at y = -h and y = h (h is an element of R+) with a semi-infinite plate at y = 0 and x < 0. Planar and homeotropic strong anchoring boundary conditions to the director field are assumed at these two infinite and semi-infinite plates, respectively. Thus, a line disclination appears in the system which coincides with the z-axis. Analytical solutions to the director field in the neighbourhood of the singularity are obtained. However, these solutions depend on an arbitrary parameter. The nematic elastic force is thus evaluated from an invariant integral of the energy-momentum tensor around a closed surface which does not contain the singularity. This allows one to determine this parameter which is a function of the nematic cell thickness and the strength of the disclination. Analytical solutions are also deduced for the director field in the whole region using the conformal mapping method. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bioactive glass nanoparticles (BGNPs) promote an apatite surface layer in physiologic conditions that lead to a good interfacial bonding with bone.1 A strategy to induce bioactivity in non-bioactive polymeric biomaterials is to incorporate BGNPs in the polymer matrix. This combination creates a nanocomposite material with increased osteoconductive properties. Chitosan (CHT) is a polymer obtained by deacetylation of chitin and is biodegradable, non-toxic and biocompatible. The combination of CHT and the BGNPs aims at designing biocompatible spheres promoting the formation of a calcium phosphate layer at the nanocomposite surface, thus enhancing the osteoconductivity behaviour of the biomaterial. Shape memory polymers (SMP) are stimuli-responsive materials that offer mechanical and geometrical action triggered by an external stimulus.2 They can be deformed and fixed into a temporary shape which remains stable unless exposed to a proper stimulus that triggers recovery of their original shape. This advanced functionality makes such SMPs suitable to be implanted using minimally invasive surgery procedures. Regarding that, the inclusion of therapeutic molecules becomes attractive.  We propose the synthesis of shape memory bioactive nanocomposite spheres with drug release capability.3   1.  L. L. Hench, Am. Ceram. Soc. Bull., 1993, 72, 93-98. 2.  A. Lendlein and S. Kelch, Angew Chem Int Edit, 2002, 41, 2034-2057. 3.  Ã . J. Leite, S. G. Caridade and J. F. Mano, Journal of Non-Crystalline Solids (in Press)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Posterior chest wall defects are frequently encountered after excision of tumors as a result of trauma or in the setting of wound dehiscence after spine surgery. Various pedicled fasciocutaneous and musculocutaneous flaps have been described for the coverage of these wounds. The advent of perforator flaps has allowed the preservation of muscle function but their bulk is limited. Musculocutaneous flaps remain widely employed. The trapezius and the latissimus dorsi (LD) flaps have been used extensively for upper and middle posterior chest wounds, respectively. Their bulk allows for obliteration of the dead space in deep wounds. The average width of the LD skin paddle is limited to 10-12 cm if closure of the donor site is expected without skin grafting. In 2001 a modification of the skin paddle design was introduced in order to allow large flaps to be raised without requiring grafts or flaps for donor site closure. This V-Y pattern allows coverage of large anterior chest defects after mastectomy. We have modified this flap to allow its use for posterior chest wall defects. We describe the flap design, its indications, and its limitations with three clinical cases. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266 .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose:To describe the indications, the surgical procedure and the clinical outcome of MLAM in the treatment of non traumatic corneal perforations and descemetoceles . Methods:A prospective, non comparative, interventional case series of eight consecutive patients (mean age 59 years old, 6 men and 2 women) with non traumatic corneal perforations or descemetoceles.The surgery consisted in a MLAM transplantation of a cryopreservated human amniotic membrane. The series included: three active herpetic keratitis, one rosacea, one perforation of an hydrops, one cicatricial pemphigoid, one perforation after an abcess in a corneal graft and one perforation after protonbeamtherapy. The clinical outcome included: the follow-up, the integrity of the eye, corneal epithelialization, inflammation and neovascularization, and the integration of the MLAM. Stromal thickness was followed precisely with the slit lamp. A corneal graft was performed at one patient after the MLAM, allowing microscopic investigation of the removed MLAM integrated in the cornea. Results:The mean follow-up was 8.78 months (range 3.57 to 30.17). Amniotic membrane transplantation was successful and reduced inflammation in 7 patients out of 8 ,after one procedure.One patient who presented a large herpetic keratitis epithelial defect with corneal anaesthesia had his MLAM dissolved after two weeks with an aqueous leakage. Epithelium healed within 3 weeks above 7 MLAM and remained stable at 3 months in 7 out of 8 patients. MLAM opacification gradually disappeared over a few months, however, stromal layers filling in the corneal perforations or above the descemetoceles remained stable. Conclusions:MLAM transplantation is a safe, effective and useful technique to cure non traumatic corneal perforations and descemetoceles. It can be performed in emergency despite the presence of an active inflammation or infection. By facilitating epithelialization, reducing inflammation and neovascularization, it allows corneal surface reconstruction in patients with persistent epithelial defects and corneal melting that usually ends in a perforation. For full visual rehabilitation, a delayed penetrating keratoplasty is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate morbidity associated with the radial forearm free flap donor site and to compare functional and aesthetic outcomes of ulnar-based transposition flap (UBTF) vs split-thickness skin graft (STSG) closure of the donor site.¦DESIGN: Case-control study.¦SETTING: Tertiary care institution.¦PATIENTS: The inclusion criteria were flap size not exceeding 30 cm(2), patient availability for a single follow-up visit, and performance of surgery at least 6 months previously. Forty-four patients were included in the study and were reviewed. Twenty-two patients had UBTF closure, and 22 had STSG closure.¦MAIN OUTCOME MEASURES: Variables analyzed included wrist mobility, Michigan Hand Outcomes Questionnaire scores, pinch and grip strength (using a dynamometer), and hand sensitivity (using monofilament testing over the radial nerve distribution). In analyses of operated arms vs nonoperated arms, variables obtained only for the operated arms included Vancouver Scar Scale scores and visual analog scale scores for Aesthetics and Overall Arm Function.¦RESULTS: The mean (SD) wrist extension was significantly better in the UBTF group (56.0° [10.4°] for nonoperated arms and 62.0° [9.7°] for operated arms) than in the STSG group (59.0° [7.1°] for nonoperated arms and 58.4° [12.1°] for operated arms) (P = .02). The improvement in wrist range of motion for the UBTF group approached statistical significance (P = .07). All other variables (Michigan Hand Outcomes Questionnaire scores, pinch and grip strength, hand sensitivity, and visual analog scale scores) were significantly better for nonoperated arms vs operated arms, but no significant differences were observed between the UBTF and STSG groups.¦CONCLUSIONS: The radial forearm free flap donor site carries significant morbidity. Donor site UBTF closure was associated with improved wrist extension and represents an alternative method of closure for small donor site defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Point defects of opposite signs can alternately nucleate on the -1/2 disclination line that forms near the free surface of a confined nematic liquid crystal. We show the existence of metastable configurations consisting of periodic repetitions of such defects. These configurations are characterized by a minimal interdefect spacing that is seen to depend on sample thickness and on an applied electric field. The time evolution of the defect distribution suggests that the defects attract at small distances and repel at large distances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extensive defects of the pelvis and genitoperineal region are a reconstructive challenge. We discuss a consecutive series of 25 reconstructions with the pedicled anterolateral thigh (ALT) flap including muscle part of the vastus lateralis (VL) in 23 patients from October 1999 to September 2012.Only surface defects larger than 100 cm and reconstructions by composite ALT + VL were included in this retrospective analysis. Of the 23 patients, 19 underwent oncologic resection, whereas 4 cases presented Fournier gangrene. Three patients did not reach 6 months of follow-up and were excluded from further data analysis. Among the remaining 20 patients (22 reconstructions), average follow-up period was 14 months (range, 10-18 months). Patient's average age was 60 years. Average size of the defect was 182 cm.Postoperative complications included 1 (4.5%) flap necrosis out of 22 raised flaps, 1 partial flap necrosis after venous congestion, and 2 cases where a complementary reconstructive procedure was performed due to remaining defect or partial flap failure. In 6 cases, peripheral wound dehiscence (27%) was treated by debridement followed by split-thickness skin graft or advancement local flaps. Defect size was significantly related to postoperative complications and increased hospital stay, especially in those patients who underwent preoperative radiotherapy. At the end of the follow-up period, a long-term and satisfactory coverage was obtained in all patients without functional deficits.This consecutive series of composite ALT + VL flap shows that, in case of extended defects, the flap provides an excellent and adjustable muscle mass, is reliable with minimal donor-site morbidity, and can even be designed as a sensate flap.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Persistent luminescence materials can store energy from solar radiation or artificial lighting and release it over a period of several hours without a continuous excitation source. These materials are widely used to improve human safety in emergency and traffic signalization. They can also be utilized in novel applications including solar cells, medical diagnostics, radiation detectors and structural damage sensors. The development of these materials is currently based on methods based on trial and error. The tailoring of new materials is also hindered by the lack of knowledge on the role of their intrinsic and extrinsic lattice defects in the appropriate mechanisms. The goal of this work was to clarify the persistent luminescence mechanisms by combining ab initio density functional theory (DFT) calculations with selected experimental methods. The DFT approach enables a full control of both the nature of the defects and their locations in the host lattice. The materials studied in the present work, the distrontium magnesium disilicate (Sr2MgSi2O7) and strontium aluminate (SrAl2O4) are among the most efficient persistent luminescence hosts when doped with divalent europium Eu2+ and co-doped with trivalent rare earth ions R3+ (R: Y, La-Nd, Sm, Gd-Lu). The polycrystalline materials were prepared with the solid state method and their structural and phase purity was confirmed by X-ray powder diffraction. Their local crystal structure was studied by high-resolution transmission electron microscopy. The crystal and electronic structure of the nondoped as well as Eu2+, R2+/3+ and other defect containing materials were studied using DFT calculations. The experimental trap depths were obtained using thermoluminescence (TL) spectroscopy. The emission and excitation of Sr2MgSi2O7:Eu2+,Dy3+ were also studied. Significant modifications in the local crystal structure due to the Eu2+ ion and lattice defects were found by the experimental and DFT methods. The charge compensation effects induced by the R3+ co-doping further increased the number of defects and distortions in the host lattice. As for the electronic structure of Sr2MgSi2O7 and SrAl2O4, the experimental band gap energy of the host materials was well reproduced by the calculations. The DFT calculated Eu2+ and R2+/3+ 4fn as well as 4fn-15d1 ground states in the Sr2MgSi2O7 band structure provide an independent verification for an empirical model which is constructed using rather sparse experimental data for the R3+ and especially the R2+ ions. The intrinsic and defect induced electron traps were found to act together as energy storage sites contributing to the materials’ efficient persistent luminescence. The calculated trap energy range agreed with the trap structure of Sr2MgSi2O7 obtained using TL measurements. More experimental studies should be carried out for SrAl2O4 to compare with the DFT calculations. The calculated and experimental results show that the electron traps created by both the rare earth ions and vacancies are modified due to the defect aggregation and charge compensation effects. The relationships between this modification and the energy storage properties of the solid state materials are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rolling element bearings are essential components of rotating machinery. The spherical roller bearing (SRB) is one variant seeing increasing use, because it is self-aligning and can support high loads. It is becoming increasingly important to understand how the SRB responds dynamically under a variety of conditions. This doctoral dissertation introduces a computationally efficient, three-degree-of-freedom, SRB model that was developed to predict the transient dynamic behaviors of a rotor-SRB system. In the model, bearing forces and deflections were calculated as a function of contact deformation and bearing geometry parameters according to nonlinear Hertzian contact theory. The results reveal how some of the more important parameters; such as diametral clearance, the number of rollers, and osculation number; influence ultimate bearing performance. Distributed defects, such as the waviness of the inner and outer ring, and localized defects, such as inner and outer ring defects, are taken into consideration in the proposed model. Simulation results were verified with results obtained by applying the formula for the spherical roller bearing radial deflection and the commercial bearing analysis software. Following model verification, a numerical simulation was carried out successfully for a full rotor-bearing system to demonstrate the application of this newly developed SRB model in a typical real world analysis. Accuracy of the model was verified by comparing measured to predicted behaviors for equivalent systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to measure full epidermal thickness, stratum corneum thickness, rete length, dermal papilla widening and suprapapillary epidermal thickness in psoriasis patients using a light microscope and computer-supported image analysis. The data obtained were analyzed in terms of patient age, type of psoriasis, total body surface area involvement, scalp and nail involvement, duration of psoriasis, and family history of the disease. The study was conducted on 64 patients and 57 controls whose skin biopsies were examined by light microscopy. The acquired microscopic images were transferred to a computer and measurements were made using image analysis. The skin biopsies, taken from different body areas, were examined for different parameters such as epidermal, corneal and suprapapillary epidermal thickness. The most prominent increase in thickness was detected in the palmar region. Corneal thickness was more pronounced in patients with scalp involvement than in patients without scalp involvement (t = -2.651, P = 0.008). The most prominent increase in rete length was observed in the knees (median: 491 µm, t = 10.117, P = 0.000). The difference in rete length between patients with a positive and a negative family history was significant (t = -3.334, P = 0.03), being 27% greater in psoriasis patients without a family history. The differences in dermal papilla distances among patients were very small. We conclude that microscope-supported thickness measurements provide objective results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Full contour monolithic zirconia restorations have shown an increased popularity in the dental field over the recent years, owing to its mechanical and acceptable optical properties. However, many features of the restoration are yet to be researched and supported by clinical studies to confirm its place among the other indirect restorative materials This series of in vitro studies aimed at evaluating and comparing the optical and mechanical properties, light cure irradiance, and cement polymerization of multiple monolithic zirconia material at variable thicknesses, environments, treatments, and stabilization. Five different monolithic zirconia materials, four of which were partially stabilized and one fully stabilized were investigated. The optical properties in terms of surface gloss, translucency parameter, and contrast ratio were determined via a reflection spectrophotometer at variable thicknesses, coloring, sintering method, and after immersion in an acidic environment. Light cure irradiance and radiant exposure were quantified through the specimens at variable thicknesses and the degree of conversion of two dual-cure cements was determined via Fourier Transform Infrared spectroscopy. Bi-axial flexural strength was evaluated to compare between the partially and fully stabilized zirconia prepared using different coloring and sintering methods. Surface characterization was performed using a scanning electron microscope and a spinning disk confocal microscope. The surface gloss and translucency of the zirconia investigated were brand and thickness dependent with the translucency values decreasing as the thickness increased. Staining decreased the translucency of the zirconia and enhanced surface gloss as well as the flexural strength of the fully stabilized zirconia but had no effect on partially stabilized zirconia. Immersion in a corrosive acid increased surface gloss and decreased the translucency of some zirconia brands. Zirconia thickness was inversely related to the amount of light irradiance, radiant exposure, and degree of monomer conversion. Type of sintering furnace had no effect on the optical and mechanical properties of zirconia. Monolithic zirconia maybe classified as a semi-translucent material that is well influenced by the thickness, limiting its use in the esthetic zones. Conventional acid-base reaction, autopolymerizing and dual-cure cements are recommended for its cementation. Its desirable mechanical properties give it a high potential as a restoration for posterior teeth. However, close monitoring with controlled clinical studies must be determined before any definite clinical recommendations can be drawn.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[1] Decadal hindcast simulations of Arctic Ocean sea ice thickness made by a modern dynamic-thermodynamic sea ice model and forced independently by both the ERA-40 and NCEP/NCAR reanalysis data sets are compared for the first time. Using comprehensive data sets of observations made between 1979 and 2001 of sea ice thickness, draft, extent, and speeds, we find that it is possible to tune model parameters to give satisfactory agreement with observed data, thereby highlighting the skill of modern sea ice models, though the parameter values chosen differ according to the model forcing used. We find a consistent decreasing trend in Arctic Ocean sea ice thickness since 1979, and a steady decline in the Eastern Arctic Ocean over the full 40-year period of comparison that accelerated after 1980, but the predictions of Western Arctic Ocean sea ice thickness between 1962 and 1980 differ substantially. The origins of differing thickness trends and variability were isolated not to parameter differences but to differences in the forcing fields applied, and in how they are applied. It is argued that uncertainty, differences and errors in sea ice model forcing sets complicate the use of models to determine the exact causes of the recently reported decline in Arctic sea ice thickness, but help in the determination of robust features if the models are tuned appropriately against observations.