994 resultados para Excisional Biopsy
Resumo:
PURPOSE: Prostate cancer (PCa) diagnosis relies on clinical suspicion leading to systematic transrectal ultrasound-guided biopsy (TRUSGB). Multiparametric magnetic resonance imaging (mpMRI) allows for targeted biopsy of suspicious areas of the prostate instead of random 12-core biopsy. This method has been shown to be more accurate in detecting significant PCa. However, the precise spatial accuracy of cognitive targeting is unknown. METHODS: Consecutive patients undergoing mpMRI-targeted TRUSGB with cognitive registration (MRTB-COG) followed by robot-assisted radical prostatectomy were included in the present analysis. The regions of interest (ROIs) involved by the index lesion reported on mpMRI were subsequently targeted by two experienced urologists using the cognitive approach. The 27 ROIs were used as spatial reference. Mapping on radical prostatectomy specimen was used as reference to determine true-positive mpMRI findings. Per core correlation analysis was performed. RESULTS: Forty patients were included. Overall, 40 index lesions involving 137 ROIs (mean ROIs per index lesion 3.43) were identified on MRI. After correlating these findings with final pathology, 117 ROIs (85 %) were considered as true-positive lesions. A total of 102 biopsy cores directed toward such true-positive ROIs were available for final analysis. Cognitive targeted biopsy hit the target in 82 % of the cases (84/102). The only identified risk factor for missing the target was an anterior situated ROI (p = 0.01). CONCLUSION: In experienced hands, cognitive MRTB-COG allows for an accuracy of 82 % in hitting the correct target, given that it is a true-positive lesion. Anterior tumors are less likely to be successfully targeted.
Resumo:
Renal biopsy is being increasingly proposed as a diagnostic tool to characterize small renal masses (SRM). Indeed, the wide adoption of imaging in the diagnostic workup of many diseases had led to a substantial increased incidence of SRM (diameter ≤4 cm). While modern ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) techniques have high sensitivity for detecting SRM, none is able to accurately and reliably characterize them in terms of histological features. This is currently of key importance in guiding clinical decision-making in some situations, and in these cases renal biopsy should be considered. In this review, we aim to summarize the technique, diagnostic performance, and predicting factors of nondiagnostic biopsy, as well as the future perspectives.
Resumo:
Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.
Resumo:
Objective To evaluate the BI-RADS as a predictive factor of suspicion for malignancy in breast lesions by correlating radiological with histological results and calculating the positive predictive value for categories 3, 4 and 5 in a breast cancer reference center in the city of São Paulo. Materials and Methods Retrospective, analytical and cross-sectional study including 725 patients with mammographic and/or sonographic findings classified as BI-RADS categories 3, 4 and 5 who were referred to the authors' institution to undergo percutaneous biopsy. The tests results were reviewed and the positive predictive value was calculated by means of a specific mathematical equation. Results Positive predictive values found for categories 3, 4 and 5 were respectively the following: 0.74%, 33.08% and 92.95%, for cases submitted to ultrasound-guided biopsy, and 0.00%, 14.90% and 100% for cases submitted to stereotactic biopsy. Conclusion The present study demonstrated high suspicion for malignancy in lesions classified as category 5 and low risk for category 3. As regards category 4, the need for systematic biopsies was observed.
Resumo:
Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.
Resumo:
L'adoption de l'IRM dans le parcours diagnostique a déterminé la transition des biopsies aléatoires aux biopsies ciblées vers les lésions visibles à l'imagerie. L'utilisation de logiciels rendant possible la fusion d'images IRM et échographiques permet d'améliorer significativement la précision diagnostique de ces biopsies. De plus, pour déterminer l'éligibilité d'un patient à une thérapie focale, davantage de précision diagnostique est requise au niveau de toute la glande ; par conséquent, des biopsies avec une densité d'échantillonnage plus élevée par voie transpérinéale peuvent être proposées.Les nouvelles techniques de biopsie de la prostate permettent une prise en charge personnalisée grâce à une meilleure caractérisation de l'agressivité et de l'extension locale du cancer de la prostate. The adoption of multiparametric MRI within the diagnostic pathway has allowed urologists to move from random biopsy to targeted biopsy directed towards MR-visible lesions. The use of software for MR to TRUS fusion may enhance the diagnostic accuracy of targeted biopsy. To determine the eligibility for tissue-preserving approaches, further precision is required, and template prostate mapping biopsy may be offered. The employment of novel biopsy techniques provide better characterisation of the disease, and allows a tailored approach to a single subject.
Resumo:
Objective: The aim of this study was to investigate the use of sentinel lymph node biopsy (SLNB) and whole body positron emission tomography (PET), with emphasis on surgical treatment and prognosis, in the detection of clinically occult metastases in patients with clinically localized cutaneous melanoma. Patients and methods: The study population consisted of 1255 patients with clinical stage I–II cutaneous melanoma, operated at Turku University Hospital between 1983 and 2007. 334 patients underwent SLNB and they were compared to 921 retrospective patients. A subgroup of 30 symptom-free patients with high risk melanoma underwent prospectively whole body PET 6–24 months postoperatively. Results: Overall, the disease-specific survival rate was 84.4 % at five years. Sex, Breslow thickness, age and nodal status were independent prognostic factors for survival. SLNB revealed occult nodal metastases in 17 % of the patients. There was no significant difference in disease-specific overall survival between SLNB patients and controls, but the nodal disease-free time was significantly longer suggesting better local control after SLNB and subsequent completion lymph node dissection. The followup time was different between the study cohorts and initial surgery was performed during different time periods. SLNB detected micrometastases in seven of 155 patients (4.5 %) with thin T1 primary melanoma and in four of 25 patients (16 %) with head and neck melanoma. In six of 30 asymptomatic patients with high risk melanoma (20 %), whole body PET detected occult distant metastases. Conclusion: Both SLNB and whole body PET were reliable methods to detect clinically occult metastases in patients with cutaneous melanoma. This upstaging altered the treatment in each case.
Resumo:
OBJETIVO: O objetivo deste estudo foi desenvolver um padrão de avaliação diagnóstica pela Core biopsy com agulha de 16G em lesões mamárias. Utilizando critérios ecográficos padronizados e relacionando os resultados ao tamanho das lesões investigadas e avaliando o número ideal de fragmentos a serem colhidos. MÉTODOS: Estudo prospectivo de maio de 2004 a setembro de 2005 em 79 pacientes com lesões incluídas nas categorias 2, 3, 4 e 5, segundo Bi-RADS® US, realizando Core Biopsy com agulha de 16G, retirando-se cinco fragmentos numerados e colocados individualmente em frascos com formol a 10%. RESULTADOS: De 84 biópsias realizadas houve 81 diagnósticos conclusivos (96%), com 43 malignos (51%) e 38 benignos (45%). A eficácia da Core biopsy aumenta com o número de amostras colhidas: com uma amostra é de 95,24%,duas amostras 96,93%; três amostras 98,8%; quatro amostras 98,81%; cinco amostras 100%. CONCLUSÃO: A retirada de três fragmentos foi suficiente para um resultado satisfatório.
Resumo:
OBJECTIVE: to evaluate the accuracy of frozen section histopathology from fragments of tissue obtained by percutaneous core needle biopsy of palpable tumors in the diagnosis of breast cancer. METHODS: a cohort study was performed on 57 patients with palpable tumors and suspected breast cancer undergoing percutaneous thick needle core biopsy. The fragments were analyzed by the same pathologist. RESULTS: frozen section diagnosed 16 benign cases (28.6%) and 40 malignant (71.4%), whereas paraffin showed that 15 were benign (26.8%) and 41 malignant (73.2%). Histopathological examinations were concordant in 55 cases and there was one false-negative (6.2%). Statistics rates were: negative predictive value of 93.8%, positive predictive value of 100%, no false-positive (0%), one false negative (6.2%), specificity of 100%, sensitivity of 97 6%; observed agreement = 98.2%; expected agreement = 59.9%, Kappa = 0.955 [ 95% CI = 0.925-0.974, p < 0.01 ]. CONCLUSIONS: frozen section histopathological findings showed excellent correlation with the findings by the technique in paraffin in the fragments of palpable breast tumors obtained by thick needle percutaneous core biopsy (98.2% accuracy). Therefore, in these patients, it was possible to anticipate the diagnosis, staging and the breast cancer treatment planning.
Resumo:
OBJETIVO: o objetivo deste estudo foi analisar os achados histológicos de lesões não palpáveis da mama localizadas por agulhamento. MÉTODOS: no estudo, 48 mulheres foram submetidas a 51 biópsias por agulhamento de lesão não palpável da mama, detectada mamograficamente, durante o período de agosto de 2001 a abril de 2005. As indicações para biópsia foram microcalcificações agrupadas, nódulos sólidos, distorção da arquitetura do parênquima e assimetria focal. As lesões foram localizadas no pré-operatório usando o método de agulhamento e todos os procedimentos foram realizados sob anestesia local e sedação endovenosa. RESULTADOS: o estudo anatomopatológico revelou se tratar de carcinoma 16 (31,4%) casos, sendo que oito (50%) casos se tratavam de carcinoma in situ e oito (50%) de carcinoma invasivo. O procedimento amostrou satisfatoriamente todas as lesões. Nas lesões malignas, em apenas 18,7% das lesões as margens cirúrgicas estavam comprometidas e novo procedimento foi realizado. Poucas pacientes apresentam complicações pós-operatórias. Quatro (7,8%) apresentaram deiscência de sutura sendo que, destas, duas (3,9%) evoluíram com infecção local. CONCLUSÕES: a localização de lesões não palpáveis da mama por agulhamento é um procedimento simples, com boa acurácia e seguro na detecção precoce do câncer de mama. O tratamento cirúrgico apropriado em procedimento único faz da técnica um excelente método no diagnóstico e tratamento deste tipo de lesão.
Resumo:
OBJETIVO: Determinar o grau de subestimação de core biopsy, guiada por imagem, de lesões impalpáveis da mama subsequentemente submetidas à exérese cirúrgica. MÉTODOS: Foram revisados retrospectivamente 352 casos com biópsias de fragmento que foram submetidos à cirurgia entre fevereiro de 2000 e dezembro de 2005, cujo laudo histopatológico estava registrado no sistema interno de informação. Os resultados foram comparados com os da cirurgia e a taxa de subestimação foi calculada dividindo-se o número de carcinoma in situ e/ou invasivo à cirurgia pelo número de lesões de alto risco ou carcinoma in situ que foram submetidas à cirurgia. O grau de concordância entre os resultados foi obtido pelo percentual de concordância e pelo coeficiente kappa de Cohen. A associação das variáveis estudadas com a subestimação do diagnóstico foi verificada pelos testes do c2 exato de Fisher, ANOVA e Mann-Whitney U. O risco de subestimação foi medido por meio do risco relativo acompanhado dos respectivos intervalos com 95% de confiança (IC95%). RESULTADOS: Core biopsy foi inconclusiva em 15,6%. O laudo histopatológico foi benigno em 26,4%, sugestivo de lesão de alto risco em 12,8% e maligno em 45,2%. A concordância entre a core biopsy e a cirurgia foi de 82,1% (kappa=0,75). A taxa de falso negativo foi de 5,4% e a lesão foi completamente removida em 3,4%. A taxa de subestimação foi de 9,1% e esteve associada com BI-RADS® categoria 5 (p=0,01), microcalcificações (p < 0,001) e estereotaxia (p= 0,002). Todos os casos subestimados apresentavam diâmetro menor que 20 mm e em todos foram retirados pelo menos cinco fragmentos. A taxa de subestimação para lesões de alto risco foi de 31,1%, 41,2%, para hiperplasia ductal atípica, 31,2% para lesões papilíferas, 16,7% para tumor filóides e 41,9% para carcinoma ductal in situ. CONCLUSÕES: Core biopsy guiada por imagem é um procedimento confiável, contudo permanece a recomendação de ressecção cirúrgica de lesões de alto risco detectadas à biópsia de fragmento já que não foi possível estabelecer características clínicas, imaginológicas, do procedimento e patológicas que pudessem predizer subestimação e evitar a cirurgia. Amostras representativas da lesão são mais importantes que o número de fragmentos.
Resumo:
With the great development of the gestational studies in all of the species, we noticed the necessity of adaptations of these techniques for prenatal diagnosis in dogs. Based on this, we studied the feasibility of chorion biopsy guided by ultrasound. Our results demonstrated accuracy on the sex determination being 2 males and 12 females, as well as it would be possible to identify chromosome alteration due to the quality of samplings. Sex determination was accomplished with the identification of Y gene chromosomes in PCR technique. After the collection, fragments were prepared for light microscopy studies and revealed fetal chorion tissue, blood colloid and erythrocyte. In the whole material we found hemosiderin impregnations due to the hemolysis and to the residue of blood of the placental marginal hematomes. The submitted female dogs to this technique demonstrated normal puppy births without death.