910 resultados para Energy performance rating


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dynamic interaction between building systems and external climate is extremely complex, involving a large number of difficult-to-predict variables. In order to study the impact of global warming on the built environment, the use of building simulation techniques together with forecast weather data are often necessary. Since all building simulation programs require hourly meteorological input data for their thermal comfort and energy evaluation, the provision of suitable weather data becomes critical. Based on a review of the existing weather data generation models, this paper presents an effective method to generate approximate future hourly weather data suitable for the study of the impact of global warming. Depending on the level of information available for the prediction of future weather condition, it is shown that either the method of retaining to current level, constant offset method or diurnal modelling method may be used to generate the future hourly variation of an individual weather parameter. An example of the application of this method to the different global warming scenarios in Australia is presented. Since there is no reliable projection of possible change in air humidity, solar radiation or wind characters, as a first approximation, these parameters have been assumed to remain at the current level. A sensitivity test of their impact on the building energy performance shows that there is generally a good linear relationship between building cooling load and the changes of weather variables of solar radiation, relative humidity or wind speed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Over the last few years more stringent environmental laws (e.g. the German “Energie¬ein-sparverordnung ENEV” - Energy Performance of Buildings Directive) and soaring energy prices has increased the need for the real estate industry to react and participate in overall energy reduction through efficient house construction and design, as well as upgrading the existing housing stock to be more energy efficient. Therefore the Property Economics Group at Queensland University of Technology in Australia and Nuertingen-Geislingen University in Germany are carrying out research in relation to sustainable housing construction and public awareness of “green” residential property. Part of this research is to gain an understanding of the level of knowledge and importance of these issues to the house buyer and to determine the importance of sustainable housing to the general public. The paper compares data from two different empirical studies; one of studies analyzes the situation in New Zealand, the other is focused on Germany.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Global warming can have a significant impact on the building thermal environment and energy performance. Because greenhouse gas concentrations are still continuing to increase, this warming process will continue and may accelerate. Adaptation to global warming is therefore emerging as one of the key requirements for buildings. This requires all the existing and new buildings not only to perform and operate satisfactorily in the new environment but also to satisfy the environmental performance criteria of sustainability. Through a parametric study using the building simulation technique, this paper investigates the adaptation potential of changing the building internal load densities to the future global warming. Case studies for office buildings in major Australian capital cities are presented. Based on the results of parametric study, possible adaptation strategies are also proposed and evaluated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As global warming entails new conditions for the built environment, the thermal and energy performance of existing buildings, which are designed based on current weather data, may become unclear and remain a great concern. Through building computer simulation and qualitative analysis of the weighted factor for the outdoor temperature impact on building energy and thermal performance, this paper investigates the sensitivity of different office building zoning to the potential global warming. A standard office building type is examined for all eight capital cities in Australia. Results show that comparing the middle and top floors, except for cool climate (i.e. Hobart), the ground floor appears to be the most sensitive to the effect of global warming and has the highest tendency for a overheating problem. From the analysis of the responses of different zone orientations to the outdoor air temperature increase, it is also found that there are widely varied responses between zone orientations, with South zone (in the southern hemisphere) being the most sensitive. With an increased external air temperature, the variation between different floors or zone orientations will become more significant, up to 53 percent increase of overheating hours in Darwin and 47 percent increase of cooling load in Hobart.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Global warming can have a significant impact on building energy performance and indoor thermal environment, as well as the health and productivity of people living and working inside them. Through the building simulation technique, this paper investigates the adaptation potential of different selections of building physical properties to increased outdoor temperature in Australia. It is found that overall, an office building with lower insulation level, smaller window to wall ratio and/or a glass type with lower shading coefficient, and lower internal load density will have the effect of lowering building cooling load and total energy use, and therefore have a better potential to adapt to the warming external climate. Compared with clear glass, it is shown that the use of reflective glass for the sample building with WWR being 0.5 reduces the building cooling load by more than 12%. A lower internal load can also have a significant impact on the reduction of building cooling load, as well as the building energy use. Through the comparison of results between current and future weather scenarios, it is found that the patterns found in the current weather scenario also exist in the future weather scenarios, but to a smaller extent.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Despite increasingly stringent energy performance regulations for new homes, southeast Queensland has a high and growing penetration of, and reliance on, air conditioners to provide thermal comfort to housing inhabitants. This reliance impacts on electricity infrastructure investment which is the key driving force behind rising electricity prices. This paper reports initial findings of a research project that seeks to better understand three key issues: (i) how families manage their thermal comfort in summer and how well their homes limit overheating; (ii) the extent to which the homes have been constructed according to the building approval documentation; and (iii) the impact that these issues have on urban design, especially in relation to electricity infrastructure in urban developments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Irradiance profile around the receiver tube (RT) of a parabolic trough collector (PTC) is a key effect of optical performance that affects the overall energy performance of the collector. Thermal performance evaluation of the RT relies on the appropriate determination of the irradiance profile. This article explains a technique in which empirical equations were developed to calculate the local irradiance as a function of angular location of the RT of a standard PTC using a vigorously verified Monte Carlo ray tracing model. A large range of test conditions including daily normal insolation, spectral selective coatings and glass envelop conditions were selected from the published data by Dudley et al. [1] for the job. The R2 values of the equations are excellent that vary in between 0.9857 and 0.9999. Therefore, these equations can be used confidently to produce realistic non-uniform boundary heat flux profile around the RT at normal incidence for conjugate heat transfer analyses of the collector. Required values in the equations are daily normal insolation, and the spectral selective properties of the collector components. Since the equations are polynomial functions, data processing software can be employed to calculate the flux profile very easily and quickly. The ultimate goal of this research is to make the concentrating solar power technology cost competitive with conventional energy technology facilitating its ongoing research.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Links between human health and wellbeing, and contact with nature are well understood in the fields of health and psychology, and more recently are gaining attention in the built environment industry. In 1984, E.O. Wilson coined the term ‘biophilia’ to describe the tendency for humans to have an innately emotional response to other living organisms. A growing number of researchers around the world are now exploring the impact of nature in urban environments (i.e. biophilic urbanism) on the human condition, including many indicators of human physical and mental health, recovery and performance. There is also an emergence of research on the potential for biophilic urbanism to address other challenges related to climate change mitigation and adaptation. This paper presents key findings from a review of key literature to date, discussing opportunities for biophilic urbanism to both improve occupant experience and performance, as well as addressing other sustainability objectives including climate change mitigation and adaptation. The paper presents an emerging framework for considering biophilic design opportunities and highlights implications for the built environment industry. This research draws on an Australian project considering biophilic urbanism in the response to climate change, within the Sustainable Built Environment National Research Centre. This includes findings from a literature review, a survey pilot study and two workshops undertaken in Perth and Brisbane with a variety of industry and government stakeholders.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

[ES]El documento que se presenta tiene como finalidad realizar la certificación energética de una vivienda perteneciente a un bloque residencial situado en Leioa. Además, se estudian diferentes medidas para obtener un mejor comportamiento térmico y se analiza la viabilidad económica de las mismas

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O potencial eólico do Brasil, de vento firme e com viabilidade econômica de aproveitamento, é de 143 GW. Isso equivale ao dobro de toda a capacidade da geração já instalada no país. No Brasil, a energia eólica tem uma sazonalidade complementar à energia hidrelétrica, porque os períodos de melhor condição de vento coincidem com os de menor capacidade dos reservatórios. O projeto desenvolvido neste trabalho nasceu de uma chamada pública do FINEP, e sob os auspícios do recém criado CEPER. Ao projeto foi incorporado um caráter investigativo, de contribuição científica original, resultando em um produto de tecnologia inovadora para aerogeradores de baixa potência. Dentre os objetivos do projeto, destacamos a avaliação experimental de turbinas eólicas de 5000 W de potência. Mais especificamente, dentro do objetivo geral deste projeto estão incluídas análise estrutural, análise aerodinâmica e análise de viabilidade de novos materiais a serem empregados. Para cada uma das diferentes áreas de conhecimento que compõem o projeto, será adotada a metodologia mais adequada. Para a Análise aerodinâmica foi realizada uma simulação numérica preliminar seguida de ensaios experimentais em túnel de vento. A descrição dos procedimentos adotados é apresentada no Capítulo 3. O Capítulo 4 é dedicado aos testes elétricos. Nesta etapa, foi desenvolvido um banco de testes para obtenção das características específicas das máquinas-base, como curvas de potência, rendimento elétrico, análise e perdas mecânicas e elétricas, e aquecimento. Este capítulo termina com a análise crítica dos valores obtidos. Foram realizados testes de campo de todo o conjunto montado. Atualmente, o aerogerador de 5kW encontra-se em operação, instrumentado e equipado com sistema de aquisição de dados para consolidação dos testes de confiabilidade. Os testes de campo estão ocorrendo na cidade de Campos, RJ, e abrangeram as seguintes dimensões de análise; testes de eficiência para determinação da curva de potência, níveis de ruído e atuação de dispositivos de segurança. Os resultados esperados pelo projeto foram atingidos, consolidando o projeto de um aerogerador de 5000W.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The decision making of customers has been a great concern in the field of customer research. Although China has entered the era of brand consumption and development, due to the different understanding of the regarded attributes between companies and customers, the phenomenon of “The awarded products don’t sell well, but the products which sell well can’t get the award.” appears. At the same time there is little research on the relationship between the brand and the customers has been conducted in China now. Traditional research on customer psychology employ questionnaires, depth interview and group discussions as the major methods. In cognitive psychology, the limitation of explicit memory has been revealed by implicit memory; moreover, unconscious cognition and implicit memory can also influence customers' remark of the brand. Therefore, the traditional methods are not accurate enough. Reaction time is an effective way to reveal testing equality, and it can also reveal implicit cognition. Based on the researches intends to investigate the validity of attention attributes in the method of reaction time by questionnaires and time reaction testing of 360 customers in 3 cities, which may, probably, overcomes the limitation of the traditional research methods. The 352 valid samples were analyzed by SPSS. The results showed there was no distinct corresponding relationship between the product attributes and reaction time. The different key attributes from questionnaire importance rating and the shortest reaction time standards were used to regressively analyze the results of customers’ overall rating (such as overall satisfaction,objective quality, recommend intention).The results indicated that the coefficiency of regression of the special attributes chosen from reaction time to overall rating was distinct, while the coefficiency of the special attributes chosen from importance rating to overall rating was not. The main conclusions are: 1. Regarded attributes can be obtained by the reaction time of brand performance rating. 2. Regarded attributes obtained by the reaction time of brand performance rating are more accurate than those by importance rating questionnaires. 3. The brand’s core attributes should includes regarded attributes during the decision making process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research aims to discuss it is the complexity of interpersonal association and job autonomy that influence the predictive validity of personality for job performance. In addition, for service profession, incumbents' personality can predict not only contextual performance, but also task performance. Salesclerks in shopping center and life insurance agents are selected as subjects. The job performance rating scale is produced by using Critical Incidents Technique. The research method is measuring NEO-PI and collecting direct supervisors' rating of salespeople's job performance. The research results are as follows: 1. The factor analysis result of job performance is different from the west. That is to say, the support for organizations which belongs to contextual performance in the west can not be distinguished from task performance. Therefore, in China, or to say in the shopping center selected, task performance includes both technical proficiency and the support for organizations, and contextual performance includes job dedication and interpersonal facilitation. 2. For salespeople, personality can be the antecedent of contextual performance and task performance as well. However, the predictive validity for task performance is very low. 3. The more complexity of interpersonal association, the stronger relationship between personality and job performance. 4a. The correlation between job performance and facets of Big Five is higher than the one between job performance and factors of Big Five, such as Agreeableness, whose facets have different impacts on job performance, some positive and others negative. 4b. The correlation between personality and the items of job performance rating scale is higher than the one between personality and the factors of job performance. 4. Working experience is the moderator of the relationship between personality and job performance. For salesclerks, only if the working experience of subjects is less than 3 years, achievement striving-one facet of conscientiousness-is significantly correlated with the ratio of finished sales volume at 0.01 level.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The coupled heat, air and moisture transfer between building envelopes and indoor air is complicated, and has a significant influence on the indoor environment and the energy performance of buildings. In the paper, a model for predicting coupled multi-zone hygrothermal-airflow transfer is presented. Both heat and moisture transfer in the building envelope and multi-zone indoor airflow are simultaneously considered; their interactions are modeled. The coupled system model is implemented into Matlab–Simulink, and is validated by using a series of testing tools and experiments. The new program is applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption in different climates (hot-humid, temperate and hot-dry climates). The results show that not accounting for hygrothermal effects in modeling will result in overestimation of energy costs for hot and humid climate situations and possible over sizing of plant leading to inefficient operation.