951 resultados para Emergency Medicine
Resumo:
OBJECTIVES: The aim of this study was to evaluate the rate and reason for refusal of telephone-based cardiopulmonary resuscitation (CPR) instruction by bystanders after the implementation of the dispatch center's systematic telephone CPR protocol. METHODS: Over a 15-month period the authors prospectively collected all case records from the emergency medical services (EMS) dispatch center when CPR had been proposed to the bystander calling in and recorded the reason for declining or not performing that the bystander spontaneously mentioned. All pediatric and adult traumatic and nontraumatic cases were included. Situations when resuscitation had been spontaneously initiated by bystanders were excluded. RESULTS: During the study period, dispatchers proposed CPR on 264 occasions: 232 adult nontraumatic cases, 17 adult traumatic cases, and 15 pediatric (traumatic and nontraumatic) cases. The proposal was accepted in 163 cases (61.7%, 95% confidence interval [CI] = 54.6% to 66.5%), and CPR was eventually performed in 134 cases (51%, 95% CI = 43.2% to 55.3%). In 35 of the cases where resuscitation was not carried out, the condition of the patient or conditions at the scene made this decision medically appropriate. Of the remaining 95 cases, 55 were due to physical limitations of the caller, and 33 were due to emotional distress. CONCLUSIONS: The telephone CPR acceptance rate of 62% in this study is comparable to those of other similar studies. Because bystanders' physical condition is one of the keys to success, the rate may not improve as the population ages.
Resumo:
The aim of this study was to investigate influence of traditional cardiovascular risk factors (CVRF) and subclinical atherosclerosis (ATS) burden on early stages of abdominal aortic diameter (AAD) widening among adults. 2,052 consecutive patients (P) (39 % women), mean age 52 ± 13 years, were prospectively screened for CVRF, ATS, and AAD. B-mode ultrasound was used to evaluate the largest AAD and to detect carotid and femoral atherosclerotic plaques. Mean AAD was 15.2 ± 2.8 mm. Atherosclerotic plaques were detected in 71 % of patients. Significant univariate correlation between AAD, traditional CVRF, and ABS was found. However, multiple regression analysis showed that only seven of them were significantly and weakly correlated with AAD (R² = 0.27, p < 0.001). On the other hand, a multivariate logistic analysis was used to evaluate CVRF impact on enlarged AAD ≥25 mm (EAAD) as compared to those with AAD <25 mm. These factors did not account for more than 30 % of interaction (R² = 0.30, p = 0.001). Furthermore, despite a large proportion of patients with high number of CVRF, and subclinical ATS, rate of patients with AAD ≥25 mm was low (1 %) and scattered regardless their CHD risk score or ATS burden. In conclusion, these results suggest that although some traditional CVRF and presence of ATS are associated with early stages of EAAD, other determinants still need to be identified for a better understanding of abdominal aortic aneurysm pathogenesis.
Resumo:
OBJECTIVE: The objective of this study was to analyse the use of lights and siren (L&S) during transport to the hospital by the prehospital severity status of the patient and the time saved by the time of day of the mission. METHODS: We searched the Public Health Services data of a Swiss state from 1 January 2010 to 31 December 2010. All primary patient transports within the state were included (24 718). The data collected were on the use of L&S, patient demographics, the time and duration of transport, the type of mission (trauma vs. nontrauma) and the severity of the condition according to the National Advisory Committee for Aeronautics (NACA) score assigned by the paramedics and/or emergency physician. We excluded 212 transports because of missing data. RESULTS: A total of 24 506 ambulance transports met the inclusion criteria. L&S were used 4066 times, or in 16.6% of all missions. Of these, 40% were graded NACA less than 4. Overall, the mean total transport time to return to the hospital was 11.09 min (confidence interval 10.84-11.34) with L&S and 12.84 min (confidence interval 12.72-12.96) without. The difference was 1.75 min (105 s; P<0.001). For night-time runs alone, the mean time saved using L&S was 0.17 min (10.2 s; P=0.27). CONCLUSION: At present, the use of L&S seems questionable given the severity status or NACA score of transported patients. Our results should prompt the implementation of more specific regulations for L&S use during transport to the hospital, taking into consideration certain physiological criteria of the victim as well as time of day of transport.
Resumo:
Introduction ICM+ software encapsulates our 20 years' experience in brain monitoring. It collects data from a variety of bedside monitors and produces time trends of parameters defi ned using confi gurable mathematical formulae. To date it is being used in nearly 40 clinical research centres worldwide. We present its application for continuous monitoring of cerebral autoregulation using near-infrared spectroscopy (NIRS). Methods Data from multiple bedside monitors are processed by ICM+ in real time using a large selection of signal processing methods. These include various time and frequency domain analysis functions as well as fully customisable digital fi lters. The fi nal results are displayed in a variety of ways including simple time trends, as well as time window based histograms, cross histograms, correlations, and so forth. All this allows complex information from bedside monitors to be summarized in a concise fashion and presented to medical and nursing staff in a simple way that alerts them to the development of various pathological processes. Results One hundred and fi fty patients monitored continuously with NIRS, arterial blood pressure (ABP) and intracranial pressure (ICP), where available, were included in this study. There were 40 severely headinjured adult patients, 27 SAH patients (NCCU, Cambridge); 60 patients undergoing cardiopulmonary bypass (John Hopkins Hospital, Baltimore) and 23 patients with sepsis (University Hospital, Basel). In addition, MCA fl ow velocity (FV) was monitored intermittently using transcranial Doppler. FV-derived and ICP-derived pressure reactivity indices (PRx, Mx), as well as NIRS-derived reactivity indices (Cox, Tox, Thx) were calculated and showed signifi cant correlation with each other in all cohorts. Errorbar charts showing reactivity index PRx versus CPP (optimal CPP chart) as well as similar curves for NIRS indices versus CPP and ABP were also demonstrated. Conclusions ICM+ software is proving to be a very useful tool for enhancing the battery of available means for monitoring cerebral vasoreactivity and potentially facilitating autoregulation guided therapy. Complexity of data analysis is also hidden inside loadable profi les, thus allowing investigators to take full advantage of validated protocols including advanced processing formulas.
Resumo:
OBJECTIVE: To assess the impact of introducing clinical practice guidelines on acute coronary syndrome without persistent ST segment elevation (ACS) on patient initial assessment. DESIGN: Prospective before-after evaluation over a 3-month period. SETTING: The emergency ward of a tertiary teaching hospital. PATIENTS: All consecutive patients with ACS evaluated in the emergency ward over the two 3-month periods. INTERVENTION: Implementation of the practice guidelines, and the addition of a cardiology consultant to the emergency team. MAIN OUTCOME MEASURES: Diagnosis, electrocardiogram interpretation, and risk stratification after the initial evaluation. RESULTS: The clinical characteristics of the 328 and 364 patients evaluated in the emergency ward for suspicion of ACS before and after guideline implementation were similar. Significantly more patients were classified as suffering from atypical chest pain (39.6% versus 47.0%; P = 0.006) after guideline implementation. Guidelines availability was associated with significantly more formal diagnoses (79.9% versus 92.9%; P < 0.0001) and risk stratification (53.7% versus 65.4%, P < 0.0001) at the end of initial assessment. CONCLUSION: Guidelines implementation, along with availability of a cardiology consultant in the emergency room had a positive impact on initial assessment of patients evaluated for suspicion of ACS. It led to increased confidence in diagnosis and stratification by risk, which are the first steps in initiating effective treatment for this common condition.
Resumo:
OBJECTIVES: To measure the proportion of adult non-traumatic cardiac or respiratory arrest among calls for seizure to an emergency medical dispatch centre and to record whether known epileptic patients present cardiac or respiratory arrest together with seizure. METHODS: This 2-year prospective observational investigation involved the collection of tape recordings of all incoming calls to the emergency medical dispatch centre, in which an out-of-hospital non-traumatic seizure was the chief complaint in patients >18 years, in addition to the paramedics' records of all patients who presented with respiratory or cardiac arrest. The authors also recorded whether the bystander spontaneously mentioned to the dispatcher that the victim was known to have epilepsy. RESULTS: During the 24-month period, the call centre received 561 incoming calls for an out-of-hospital non-traumatic seizure in an adult. Twelve cases were classified as cardiac or respiratory arrest by paramedics. In one case, the caller spontaneously mentioned that the victim had a history of epilepsy. The proportion of cardiac or respiratory arrest among calls for seizure was 2.1%. CONCLUSION: Although these cases are rare, dispatchers should closely monitor seizure patients with the help of bystanders to exclude an out-of-hospital cardiac or respiratory arrest, in which case the dispatcher can offer telephone cardiopulmonary resuscitation advice until the paramedics arrive. Whenever the activity of the centre allows it and no new incoming call is on hold, this can be achieved by staying on the line with the caller or by calling back. A history of epilepsy should not modify the type of monitoring performed by the dispatcher as those patients may also have an arrest together with seizure.
Resumo:
Spinal epidural hematoma (SEH) is a rare neurosurgical emergency. SEH is characterized by an archetypal clinical presentation including abrupt spinal pain followed more or less rapidly by various degrees of neurological deficit. The diagnosis of SEH, often based on a clinical presumption, represents a clinical challenge. Several reports have outlined missed or delayed diagnosis due to unusual and confusing onsets or unawareness of this diagnosis by physicians. Therefore, physicians should keep in mind the possibility of SEH in their differential diagnosis when confronted with patients complaining of sudden onset of acute spinal pain with or without neurological sign, because the impact of a delayed diagnosis can be disabling catastrophic neurological sequelae. We suggest that SEH is a dynamic disease, which occurs in patients with an abnormal vasculature structural degenerative change. The bleeding is probably of multifactorial origin incriminating veins as well as arteries. Therefore, we proposed a classification of SEH, according to the most probable etiology whatever the associated factors, in six groups: spontaneous, secondary, iatrogenic, traumatic, recurrent, and idiopathic SEH.
Resumo:
The use of electronic control devices has expanded worldwide during the last few years, the most widely used model being the Taser. However, the scientific knowledge about electronic control devices remains limited. We reviewed the medical literature to examine the potential implications of electronic devices in terms of morbidity and mortality, and to identify and evaluate all the existing experimental human studies. A single exposure of an electronic control device on healthy individuals can be assumed to be generally safe, according to 23 prospective human experimental studies and numerous volunteer exposures. In case series, however, electronic control devices could have deleterious effects when used in the field, in particular if persons receive multiple exposures, are intoxicated, show signs of "excited delirium," or present with medical comorbidities. As the use of electronic control devices continues to increase, the controversy about its safety, notably in potentially high-risk individuals, is still a matter of debate. The complications of electronic control device exposure are numerous but often recognizable, usually resulting from barbed dart injuries or from falls. Persons exposed to electronic control devices should therefore be fully examined, and traumatic lesions must be ruled out.
Resumo:
Less-lethal weapons are used in law enforcement to neutralize combative individuals and to disperse riot crowds. Local police recently used such an impact weapon, the Flash-Ball, in two different situations. This gun fires large rubber bullets with kinetic energies around 200 J. Although it is designed to avoid skin penetration, impacts at such energies may still create major trauma with associated severe injuries to internal organs. This is a report of 2 patients shot with the Flash-Ball who required medical attention. One could be discharged quickly, but the other required hospitalization for heart and lung contusion. Both patients required advanced investigations including computed tomography (CT) scan. The medical literature on injuries induced by less-lethal impact weapons is reviewed. Impacts from the Flash-Ball can cause significant injury to internal organs, even without penetration. Investigations as for other high-energy blunt traumas are called for in these cases.