809 resultados para Electrochemical immunoassay
Resumo:
INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.
Resumo:
Nowadays, antibacterial properties are becoming a viable feature to be introduced in biomaterials due to the possibility of modifying the materials' surface used in medical devices in a micro/nano metric scale. As a result, it is mandatory to understand the mechanisms of the antimicrobial agents currently used and their possible failures. In this work, the antibacterial activity of ZrCNAg films is studied, taking into consideration the ability of silver nanoparticles to be dissolved when embedded into a ceramic matrix. The study focuses on the silver release evaluated by glow discharge optical emission spectroscopy and the effect of the fluid composition on this release. The results revealed a very low silver release of the films, leading to non-antibacterial activity of such materials. The silver release was found to be dependent on the electrolyte composition. NaCl (8.9 g L? 1) showed the lowest spontaneously silver ionization, while introducing the sulfates in Hanks' balanced salt solution (HBSS) such ionization is increased; finally, the proteins incorporated to the (HBSS) showed a reduction of the silver release, which also explains the low ionization in the culture medium (tryptic soy broth) that contains high quantities of proteins.
Resumo:
Radical cyclization continues to be a central methodology for the preparation of natural products containing heterocyclic rings. Hence, some electrochemical results obtained by cyclic voltammetry and controlled-potential electrolysis in the study of electroreductive intramolecular cyclization of ethyl (2S, 3R)-2-bromo-3-propargyloxy-3-(2’,3’,4’,6’-tetra-O-acetyl-beta-D-glucopyranosyloxy) propanoate (1a), 2-bromo-3-allyloxy-3-(2’,3’,4’,6’-tetra-O-acetyl-beta-D-glucopyranosyloxy)propanoate (1b), 2-bromo-[1-(prop-2-yn-1-yloxy)propyl]benzene (1c) and [1-bromo-2-methoxy-2-(prop-2’-yn-1-yloxy)ethyl]benzene (1d) promoted by (1,4,8,11-tetramethyl-1,4,8,11-tetraazacyclotetradecane)nickel(I), [Ni(tmc)]+, electrogenerated at glassy carbon cathodes in ethanol and ethanol:water mixtures containing tetraalkylammonium salts, are presented. During controlled-potential electrolyses of solutions containing [Ni(tmc)]2+ and bromoalkoxylated compounds (1) catalytic reduction of the latter proceeds via one-electron cleavage of the carbon–bromine bond to form a radical intermediate that undergoes cyclization to afford the substituted tetrahydrofurans.
Resumo:
Los requerimientos de métodos analíticos que permitan realizar determinaciones más eficientes en diversas ramas de la Química, así como el gran desarrollo logrado por la Nanobiotecnología, impulsaron la investigación de nuevas alternativas de análisis. Hoy, el campo de los Biosensores concita gran atención en el primer mundo, sin embargo, en nuestro país es todavía un área de vacancia, como lo es también la de la Nanotecnología. El objetivo de este proyecto es diseñar y caracterizar nuevos electrodos especialmente basados en el uso de nanoestructuras y estudiar aspectos básicos de la inmovilización de enzimas, ADN, aptámeros, polisacáridos y otros polímeros sobre dichos electrodos a fin de crear nuevas plataformas de biorreconocimiento para la construcción de (bio)sensores electroquímicos dirigidos a la cuantificación de analitos de interés clínico, farmaco-toxicológico y ambiental.Se estudiarán las propiedades de electrodos de C vítreo, Au, "screen printed" y compósitos de C modificados con nanotubos de C (CNT) y/o nanopartículas (NP) de oro y/o nanoalambres empleando diversas estrategias. Se investigarán nuevas alternativas de inmovilización de las biomoléculas antes mencionadas sobre dichos electrodos, se caracterizarán las plataformas resultantes y se evaluarán sus posibles aplicaciones analíticas al desarrollo de biosensores con enzimas y ADNs como elementos de biorreconocimiento. Se funcionalizarán CNT con polímeros comerciales y sintetizados en nuestro laboratorio modificados con moléculas bioactivas. Se diseñarán y caracterizarán nuevas arquitecturas supramoleculares basadas en el autoensamblado de policationes, enzimas y ADNs sobre Au. Se evaluarán las propiedades catalíticas de NP de magnetita y de perovskitas de Mn y su aplicación al desarrollo de biosensores enzimáticos. Se diseñarán biosensores que permitan la detección altamente sensible y selectiva de secuencias específicas de ADNs de interés clínico. Se estudiará la interacción de genotóxicos con ADN (en solución e inmovilizado) y se desarrollarán biosensores que permitan su cuantificación. Se construirán biosensores enzimáticos para la cuantificación de bioanalitos, especialmente glucosa, fenoles y catecoles, y sensores electroquímicos para la determinación de neurotransmisores, ácido úrico y ácido ascórbico. Se diseñarán nuevos aptasensores electroquímicos para la cuantificación de biomarcadores, comenzando por lisozima y trombina y continuando con otros de interés regional/nacional.Se emplearán las siguientes técnicas: voltamperometrías cíclica (CV), de pulso diferencial (DPV) y de onda cuadrada (SWV); "stripping" potenciométrico a corriente constante (PSA); elipsometría; microbalanza de cristal de cuarzo con cálculo de pérdida de energía por disipación (QCM-D); resonancia de plasmón superficial con detección dual (E-SPR); espectroscopía de impedancia electroquímica (EIE); microscopías de barrido electroquímico (SECM), de barrido electrónico (SEM), de transmisión (TEM) y de fuerzas atómicas (AFM); espectrofotometría UV-visible; espectroscopías IR, Raman, de masas, RMN.Se espera que la inclusión de los CNT y/o de las NP metálicas y/o de los nanoalambres en los diferentes electrodos permita una mejor transferencia de carga de diversos analitos y por ende una detección más sensible y selectiva de bioanalitos empleando enzimas, ADN y aptámeros como elementos de biorreconocimiento. Se espera una mayor eficiencia en los aptasensores respecto de los inmunosensores, lo que permitirá la determinacion selectiva de diversos biomarcadores. La modificación de electrodos con nanoestructuras posibilitará la detección altamente sensible y selectiva del evento de hibridación. La respuesta obtenida luego de la interacción de genotóxicos con ADN permitirá un mejor conocimiento de la asociación establecida, de la cinética y de las constantes termodinámicas. Los neurotransmisores podrán ser determinados a niveles nanomolares aún en muestras complejas.
Resumo:
Se estudiarán los mecanismos de reacción electroquímica de las micotoxinas (metabolitos tóxicos generados por hongos) citrinina (CIT), patulina (PAT) y moniliformina (MON), de los antioxidantes naturales alfa, beta, gama y delta tocoferoles, de los flavonoides fisetina (FIS), morina (MOR), luteolina (LUT), rutina (RUT), buteina (BUT), naringenina (NAR) y miricetina (MIR) y de las hormonas esteroides estradiol (EDIOL), estrona (EONA) y estriol (ETRIOL). Por otra parte, se implementarán técnicas electroanalíticas para la detección y cuantificación de estos sustratos en muestras de matrices naturales que los contengan. Se realizará el diseño y caracterización de biosensores enzimáticos a partir de peroxidasas y/o fosfatasa alcalina para la determinación de la micotoxina CIT y de los flavonoides y, por otro, de inmunosensores para las micotoxinas ocratoxina A (OTA) y PAT y hormonas. Para el anclaje de enzimas y/o anticuerpos, se estudiarán las propiedades de electrodos modificados por monocapas autoensambladas, nanotubos de carbono y partículas magnéticas. Se usarán las técnicas de voltamperometría cíclica, de onda cuadrada y de redisolución con acumulación adsortiva, espectroscopías de impedancia electroquímica, electrólisis a potencial controlado, uv-vis e IR, microbalanza de cristal de cuarzo y microscopías de alta resolución (SEM, TEM, AFM). La importancia de este proyecto apunta a la obtención de nuevos datos electroquímicos de los sustratos indicados y conocimientos relacionados con la aplicación de electrodos modificados en la preparación de biosensores y en el desarrollo de técnicas alternativas para la determinación de los analitos mencionados precedentemente. Electrochemical reaction mechanisms of mycotoxins (toxic metabolites generated by fungi) citrinin (CIT), Patulin (PAT) and moniliformin (MON), natural antioxidants alpha, beta, gamma and delta tocopherols, flavonoids fisetin (FIS), morin (MOR), luteolin (LUT), rutin (RUT), butein (BUT), naringenin (NAR), miricetin (MIR) and steroid hormones estradiol (EDIOL), estrone (EONA) and estriole (ETRIOL) will be explored. On the other hand, electroanalytical techniques for the detection and quantification of these substrates in samples of natural matrices will be implemented. The design and characterization of enzymatic biosensors from peroxidases and/or from alkaline phosphatase for the determination of CIT and flavonoids, and also of inmunosensors for ochratoxin A (OTA) and PAT and hormones will be performed. For the anchor of enzymes and/or antibody, properties of electrodes modified by self assembled monolayers, carbon nanotubes and magnetic particles will be explored. Cyclic, square wave and adsorptive stripping voltammetries, electrochemical impedance spectroscopy, controlled potential electrolysis, uv-vis and IR, quartz crystal microbalance and high-resolution microcopies (SEM, TEM, AFM) will be used. The importance of this project is aimed at obtaining new electrochemical data for the indicated substrates and knowledge on the application of modified electrodes in preparation of biosensors and in the development of alternative techniques for the determination of the above-mentioned analytes.
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2013
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2014
Resumo:
Detection of rotavirus RNA by polyacrylamide gel electrophoresis (PAGE) proved to be a highly sensitive and rapid diagnostic test. A comparison of this assay with immuno-electron microscopy (IEM) and enzyme immunoassay (EIA) in 245 faeces from children with gastroenteritis revealed complete agreement between the three assays in 238 (97.14%) samples. Among 75 samples positive in at least one of the three assays, negative results were observed in 5 (6.48%) by PAGE, in 6 (6.76%) by EIA and in none by IEM. Silver staining greatly increased the sensitivity of the PAGE assay. We conclude that although IEM remains the most sensitive and rapid rotavirus diagnostic assay, the PAGE technique has many advantages in its favour, including the non-requirement of expensive equipment, the use of only chemically defined reagents and the capacity to distinguish virus subgroup and variants and to detect non-crossreactive rotaviruses which are missed in serological assays.
Resumo:
Two techniques for rapid diagnosis, immunofluorescence (IFAT) and enzyme immunoassay (EIA), have been compared with virus isolaion in tissue culture for the detection of respiratory syncytial virus (RSV) in specimens of nasopharyngeal secretions. The specimens were obtained from children under five years of age suffering from acute respiratory iliness, during a period of six months from January to June 1982. Of 471 specimens examined 54 (11.5%) were positive by virus isolation and 180 (38.2%) were positive by immunofluorescence. The bacterial contamination of inoculated tissue cultures unfortunately prevented the isolation of virus from many samples. Specimens from 216 children were tested to compare enzyme immunoassay and immunofluorescence. Of these 60 (27%) were positive by EIA and 121 (56%) were positive by IFAT. Our results suggest that the EIA technique although highly specific is rather insensitive. This may be because by the time these tests were done the originl nasopharyngeal secretions were considerably diluted and contained more mucus fragments than the call suspension used for IFAT. Of the three techniques, IFAT gives the best results although EIA may be useful where IFAT is not possible.
Resumo:
A new serological assay dot-dye-immunoassay (dot-DIA) was evaluated for the diagnosis of schistosomiasis mansoni. This method consist of four steps: (a) biding of antigens to a nitrocellulose membrane (NC); (b) blocking of free sites of the NC; (c) incubation in specific primary antibody; (d) detection of primary antibody reactivity by color development using second antibody coupled to textile dyes. Sera from 82 individuals, 61 with Schistosoma mansoni eggs in the stool and 21 stool negative were tested by ELISA, dot-ELISA, and dotDIA. A high level of agreement between the methods tested was observed for all sera tested: ELISA x dot-ELISA: 95.1%, ELISA x dot-DIA: 92.7% and dot-ELISA x dot-DIA: 97.6%. In this study, dot-DIA proved to be a feasible, sensitive, rapid and practical test for the diagnosis of shcistosomiasis.
Resumo:
Blood sampling on filter paper is a current practice seroepidemiological studies by indirect fluorescent antibody test (IFAT). There is, however, scant comparative information about the use of bloodspot eluates for detection of malarial IgG antibodies simultaneously by IFAT and enzyme immunoassay (ELISA). Here we report data obtained by both serological methods done on 219 bloodspot eluate samples collected in a rural community in Brazilian Amazon Basin (Alto Paraíso, Ariquemes municipality) where malaria is endemic. Plasmodium falciparum and P. vivax thick smear antigens were used in the IFAT; a detergent-soluble P. falciparum antigen was prepared for ELISA. Substantial agreement of results (Kappa coefficient k = 0.686) was observed when P. falciparum antigen was used in both tests, and IFAT titers were found to be strongly correlated ELISA antibody units (Spearman correlation coeficient rs = 0.818, p < 0.0001). Only moderate agreement (k = 0.467) between IFAT with P. vivax antigen and ELISA with P. falciparum antigen was observed. Spearman correlation coefficient value between quantitative results (IFAT titers and ELISA antibody units) in this case was numerically lowe (rs = 0.540, p < 0.0001). Our results suggest that, with P. falciparum antigen, both IFAT and ELISA performed on bloodspot eluates are equivalent for seropidemiological purposes.
Resumo:
The ID-Chagas test is a particle gel immunoassay (PaGIA). Red coloured particles are sensitised with three different synthetic peptides representing antigen sequences of Trypanosoma cruzi: Ag2, TcD and TcE. When these particles are mixed with serum containing specific antibodies, they agglutinate. The reaction mixture is centrifuged through a gel filtration matrix allowing free agglutinated particles to remain trapped on the top or distributed within the gel. The result can be read visually. In order to investigate the ability of the ID-PaGIA to discriminate negative and positive sera, 111 negative and 119 positive, collected in four different Brazilian institutions, were tested by each of the participants. All sera were previously classified as positive or negative according to results obtained with three conventional tests (indirect immunofluorescence, indirect hemaglutination, and enzime linked immunosorbent assay). Sensitivity rates of ID-PaGIA varied from 95.7% to 97.4% with mean sensitivity of 96.8% and specificity rates varied from 93.8 to 98.8% with mean specificity of 94.6%. The overall Kappa test was 0.94. The assay presents as advantages the simplicity of operation and the reaction time of 20 min. In this study, ID-PaGIA showed to be highly sensitive and specific.
Resumo:
This study was undertaken to evaluate an enzyme immunoassay (EIA) for hepatitis C virus antibody detection (anti-HCV), using just one antigen. Anti-HCV EIA was designed to detect anti-HCV IgG using on the solid-phase a recombinant C22 antigen localized at the N-terminal end of the core region of HCV genome, produced by BioMérieux. The serum samples diluted in phosphate buffer saline were added to wells coated with the C22, and incubated. After washings, the wells were loaded with conjugated anti-IgG, and read in a microtiter plate reader (492 nm). Serum samples of 145 patients were divided in two groups: a control group of 39 patients with non-C hepatitis (10 acute hepatitis A, 10 acute hepatitis B, 9 chronic hepatitis B, and 10 autoimmune hepatitis) and a study group consisting of 106 patients with chronic HCV hepatitis. In the study group all patients had anti-HCV detected by a commercially available EIA (Abbott®), specific for HCV structural and nonstructural polypeptides, alanine aminotransferase elevation or positive serum HCV-RNA detected by nested-PCR. They also had a liver biopsy compatible with chronic hepatitis. The test was positive in 101 of the 106 (95%) sera from patients in the study group and negative in 38 of the 39 (97%) sera from those in the control group, showing an accuracy of 96%. According to these results, our EIA could be used to detect anti-HCV in the serum of patients infected with hepatitis C virus.