923 resultados para Effect of pressure
Resumo:
The influence of the partial pressure of carbon dioxide (CO2) on the thermal decomposition process of a calcite (CI) and a dolomite (DP) is investigated in this paper using a thermogravimetric analyser. The tests were non-isothermal at five different heating rates in dynamic atmosphere of air with 0% and 15% carbon dioxide (CO2). In the atmosphere without CO2, the average activation energies (E-alpha) were 197.4 kJ mol(-1) and 188.1 kJ mol(-1) for CI and DP, respectively. For the DP with 15% CO2, two decomposition steps were observed, indicating a change of mechanism. The values of E-alpha for 15% CO2 were 378.7 kJ mol(-1) for the CI, and 299.8 kJ mol(-1) (first decomposition) and 453.4 kJ mol(-1) (second decomposition) for the DP, showing that the determination of E-alpha for DP should in this case be considered separately in those two distinct regions. The results obtained in this study are relevant to understanding the behaviour changes in the thermal decomposition of limestones with CO2 partial pressure when applied to technologies, such as carbon capture and storage (CCS), in which carbon dioxide is present in high concentrations.
Resumo:
Several studies have demonstrated that one exercise session (ES) on a cycloergometer or ergometric treadmill causes a reduction in blood pressure (BP). However, there are few similar studies on walking, which is the exercise modality most available to the elderly. We investigated the immediate and 24-h effects of walking on BP in independent, community-living elderly individuals. Volunteers participated in a single ES and resting control session (CS). Before and after each session, BP was measured by auscultatory and oscillometric methods. After each session, 24-h ambulatory blood pressure monitoring was conducted. An accelerometer was installed 48 h before the sessions and left in place for 5 days. The mean volunteer age was 67.7 +/- 3.5 years; 11 were hypertensive patients under treatment, and 12 were normotensive. In the total sample, there were immediate 14mm Hg and 12 mm Hg reductions in systolic BP (SBP) after the ES according to the auscultatory and oscillometric methods, respectively. Diastolic BP (DBP) was reduced by 4 mm Hg after the ES according to both methods. SBP during wakefulness and sleep and DBP during wakefulness were lower after the ES than after the CS (P<0.01), when wakefulness and sleep were determined individually (variable-time pattern) using data from the activity monitors and provided by the volunteers. The variable-time pattern was more effective in detecting reductions in BP than the fixed-time pattern. Hypertension Research (2012) 35, 457-462; doi: 10.1038/hr.2011.227; published online 9 February 2012
Resumo:
Tolerance to low temperature and high pressure may allow shallow-water species to extend bathymetric range in response to changing climate, but adaptation to contrasting shallow-water environments may affect tolerance to these factors. The brackish shallow-water shrimp Palaemon varians demonstrates remarkable tolerance to elevated hydrostatic pressure and low temperature, but inhabits a highly variable environment: environmental adaptation may therefore make P. varians tolerances unrepresentative of other shallow-water species. Critical thermal maximum (CTmax), critical hydrostatic pressure maximum (CPmax), and acute respiratory response to hydrostatic pressure were assessed in the shallow-water shrimp Palaemon serratus, which inhabits a more stable intertidal habitat. P. serratus’ CTmax was 22.3°C when acclimated at 10°C, and CPmax was 5.9, 10.1, and 14.1 MPa when acclimated at 5, 10, and 15°C respectively: these critical tolerances were consistently lower than P. varians. Respiratory responses to acute hyperbaric exposures similarly indicated lower tolerance to hydrostatic pressure in P. serratus than in P. varians. Contrasting tolerances likely reflect physiological adaptation to differing environments and reveal that the capacity for depth-range extension may vary among species from different habitats.
Resumo:
To demonstrate that abdominal pressure impacts venous flow and pressure characteristics.
Resumo:
The host's immune response to hepatitis C virus (HCV) can result in the selection of characteristic mutations (adaptations) that enable the virus to escape this response. The ability of the virus to mutate at these sites is dependent on the incoming virus, the fitness cost incurred by the mutation, and the benefit to the virus in escaping the response. Studies examining viral adaptation in chronic HCV infection have shown that these characteristic immune escape mutations can be observed at the population level as human leukocyte antigen (HLA)-specific viral polymorphisms. We examined 63 individuals with chronic HCV infection who were infected from a single HCV genotype 1b source. Our aim was to determine the extent to which the host's immune pressure affects HCV diversity and the ways in which the sequence of the incoming virus, including preexisting escape mutations, can influence subsequent mutations in recipients and infection outcomes. Conclusion: HCV sequences from these individuals revealed 29 significant associations between specific HLA types within the new hosts and variations within their viruses, which likely represent new viral adaptations. These associations did not overlap with previously reported adaptations for genotypes 1a and 3a and possibly reflected a combination of constraint due to the incoming virus and genetic distance between the strains. However, these sites accounted for only a portion of the sites in which viral diversity was observed in the new hosts. Furthermore, preexisting viral adaptations in the incoming (source) virus likely influenced the outcomes in the new hosts.
Resumo:
Vertebroplasty restores stiffness and strength of fractured vertebral bodies, but alters their stress transfer. This unwanted effect may be reduced by using more compliant cements. However, systematic experimental comparison of structural properties between standard and low-modulus augmentation needs to be done. This study investigated how standard and low-modulus cement augmentation affects apparent stiffness, strength, and endplate pressure distribution of vertebral body sections.
Resumo:
Obstructive sleep apnea (OSA) has been associated with an increased risk of atherothrombotic events. A prothrombotic state might partially explain this link. This study investigated OSA patients' day/night rhythm of several prothrombotic markers and their potential changes with therapeutic continuous positive airway pressure (CPAP).
Resumo:
Donepezil, a selective acetylcholinesterase (AChE) inhibitor, has been shown to reduce intraocular pressure (IOP) in ocular normotensive rabbit eyes. The aim of this investigation was to evaluate the effect of oral donepezil on IOP and pupil diameter after mid-term oral treatment in normotensive persons. Thirty-two newly diagnosed Alzheimer patients with normal IOP and no further antiglaucomatous treatment were included in the study. IOP and pupil diameter were evaluated before and 4 weeks after daily intake of 5 mg donepezil. IOP and pupil diameter were significantly lower/smaller after 4 weeks of treatment. The mean IOP of all 63 eyes was 14.1 mmHg before and 12.8 mmHg after treatment (8.8% reduction). Mean pupil diameter constricted from 3.9 to 3.6 mm (-7.4%). These findings show that donepezil, and, possibly, other selective AChE inhibitors, can potentially be used to treat glaucoma. They are also known to have neuroprotective effects in Alzheimer's, and, therefore, might have an additional therapeutic benefit.
Resumo:
BACKGROUND: Intradialytic exercise has been described to improve blood pressure stability and dialysis efficacy. However, comorbid conditions in the dialysis population often preclude the widespread use of active intradialytic exercise. Therefore, we investigated the effect of intradialytic transcutaneous muscle stimulation (TEMS) and passive cycling movements (PCMs) on blood pressure and dialysis efficacy in patients. STUDY DESIGN: Prospective, controlled, randomized, crossover investigation. SETTING ; PARTICIPANTS: Ten patients were randomly allocated to TEMS, PCMs, or no intervention (NI) for 9 consecutive dialysis sessions. INTERVENTION: Participants were studied with NI, PCMs using a motor-driven ergometer, and bilateral TEMS of the leg musculature. Individual dialysis prescriptions were unchanged during the investigation. OUTCOMES ; MEASUREMENTS: The effect of TEMS and PCMs on blood pressure and dialysis efficacy in patients was assessed. RESULTS: Mean blood pressure increased from 121/64 +/- 21/15 mm Hg with NI to 132/69 +/- 21/15 mm Hg (P < 0.001) during sessions with PCMs and 125/66 +/- 22/16 mm Hg (P < 0.05) during sessions with TEMS. Urea and phosphate removal during dialysis were significantly (P < 0.001) greater with TEMS (19.4 +/- 3.7 g/dialysis and 1,197 +/- 265 mg/dialysis) or PCMs (20.1 +/- 3.4 g/dialysis and 1,172 +/- 315 mg/dialysis) than with NI (15.1 +/- 3.9 g/dialysis and 895 +/- 202 mg/dialysis). Body weight, ultrafiltration, Kt/V, and increases in hemoglobin and albumin levels during dialysis did not differ among the NI, PCMs, and TEMS groups. LIMITATIONS: The study design does not allow extension of the findings to prolonged treatment. CONCLUSION: Future studies during longer observation periods will have to prove the persistence of these acute findings. Both TEMS and PCMs deserve future investigations in dialysis patients because they increase intradialytic blood pressure and facilitate urea and phosphate removal when applied short term.
Resumo:
Background Open-irrigated radiofrequency catheter ablation (oiRFA) of atrial fibrillation (AF) imposes a volume load and risk of pulmonary edema. We sought to assess the effect of volume administration during ablation on left atrial (LA) pressure and B-type natriuretic peptide (BNP). Methods LA pressure was measured via transseptal sheath at the beginning and end of 44 LA ablation procedures in 42 patients. BNP plasma levels were measured before and after 10 procedures. Results A median of 3,255 (interquartile range [IQR], 2,014)-mL saline was administered during the procedure. During LA ablation, the median fluid balance was +1,438 (IQR, 1,109) mL and LA pressure increased by median 3.7 (IQR, 5.9) mm Hg (P < 0.001). LA pressure did not change in the 19 procedures with furosemide administration (median ΔP = −0.3 [IQR, 7.1] mm Hg, P = 0.334). The correlation of LA pressure and fluid balance was weak (rs = 0.383, P = 0.021). BNP decreased in all four procedures starting in AF or atrial tachycardia and then converting to sinus rhythm (P = 0.068), and increased in all six procedures starting and finishing in sinus rhythm (P = 0.028). After ablation, symptomatic volume overload responding to diuresis occurred in three patients. Conclusions A substantial intravascular volume load during oiRFA can be absorbed with little change in LA pressure, such that LA pressure is not a reliable indicator of the fluid balance. Subsequent redistribution of the volume load imposes a risk after the procedure. Conversion to sinus rhythm may improve ability to acutely accommodate the volume load.
Resumo:
Recently, ocular vestibular evoked myogenic potentials (oVEMP) have emerged as a tool for assessment of utricular function. They are short-latency myogenic potentials which can be elicited in response to vestibular stimulation, e.g. by air-conducted sound (ACS) or bone-conducted vibration (BCV) (reviewed in (Kantner and Gurkov, 2012)). Otolithic afferent neurons trigger reflexive electromyographic activity of the extraocular muscles which can be recorded beneath the eye contralateral to the stimulated ear by use of surface electrodes.
Resumo:
OBJECTIVE Ocular vestibular-evoked myogenic potentials (oVEMPs) represent extraocular muscle activity in response to vestibular stimulation. The authors sought to investigate whether posture-induced increase of the intracranial pressure (ICP) modulated oVEMP frequency tuning, that is, the amplitude ratio between 500-Hz and 1000-Hz stimuli. DESIGN Ten healthy subjects were enrolled in this study. The subjects were positioned in the horizontal plane (0 degree) and in a 30-degree head-downwards position to elevate the ICP. In both positions, oVEMPs were recorded using 500-Hz and 1000-Hz air-conducted tone bursts. RESULTS When tilting the subject from the horizontal plane to the 30-degree head-down position, oVEMP amplitudes in response to 500-Hz tone bursts distinctly decreased (3.40 μV versus 2.06 μV; p < 0.001), whereas amplitudes to 1000 Hz were only slightly diminished (2.74 μV versus 2.48 μV; p = 0.251). Correspondingly, the 500/1000-Hz amplitude ratio significantly decreased when tilting the subjects from 0- to 30-degree inclination (1.59 versus 1.05; p = 0.029). Latencies were not modulated by head-down position. CONCLUSIONS Increasing ICP systematically alters oVEMPs in terms of absolute amplitudes and frequency tuning characteristics. oVEMPs are therefore in principle suited for noninvasive ICP monitoring.