795 resultados para ESMALTE DENTÁRIO


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of adding calcium ions and fluoride in the formulation of a whitening gel 35% hydrogen peroxide in its penetration through the dental structure, whitening efficacy and surface hardness of dental enamel. 80 teeth bovine incisors were used, which were obtained enamel and dentin disks of the buccal surface with 6mm diameter and 2mm thick (1 mm of enamel and dentin 1mm). The samples were divided into four groups stratified according to the protective substance / remineralizing added to the gel of hydrogen peroxide 35%: Group Ca - Calcium gluconate 0.5%; Group F - Sodium fluoride 0.2%; Group Ca + F - Calcium gluconate 0.5% and Sodium Fluoride 0.2%; Control group - no substance was added. The initial color of the samples and the hardness of the enamel were measured before the bleaching procedures. The specimens from each group were placed on a metallic support on which there was a simulated pulp chamber, which was filled with acetate buffer to collect and stabilize the penetrated peroxide. The respective bleaching treatments were applied 3 times, total of 30 minutes of application. The amount of peroxide which passed through the samples was determined by absorbance spectrophotometry. The hardness of the samples was measured immediately after bleaching. Next, the samples were immersed in artificial saliva for 7 days, after which the final color was evaluated. Data were statistically analyzed adopting a 5% significance level

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of adding calcium ions and fluoride in the formulation of a whitening gel 35% hydrogen peroxide in its penetration through the dental structure, whitening efficacy and surface hardness of dental enamel. 80 teeth bovine incisors were used, which were obtained enamel and dentin disks of the buccal surface with 6mm diameter and 2mm thick (1 mm of enamel and dentin 1mm). The samples were divided into four groups stratified according to the protective substance / remineralizing added to the gel of hydrogen peroxide 35%: Group Ca - Calcium gluconate 0.5%; Group F - Sodium fluoride 0.2%; Group Ca + F - Calcium gluconate 0.5% and Sodium Fluoride 0.2%; Control group - no substance was added. The initial color of the samples and the hardness of the enamel were measured before the bleaching procedures. The specimens from each group were placed on a metallic support on which there was a simulated pulp chamber, which was filled with acetate buffer to collect and stabilize the penetrated peroxide. The respective bleaching treatments were applied 3 times, total of 30 minutes of application. The amount of peroxide which passed through the samples was determined by absorbance spectrophotometry. The hardness of the samples was measured immediately after bleaching. Next, the samples were immersed in artificial saliva for 7 days, after which the final color was evaluated. Data were statistically analyzed adopting a 5% significance level

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the capacity of fluoride acidic dentifrices (pH 4.5) to promote enamel remineralization using a pH cycling model, comparing them with a standard dentifrice (1,100 µgF/g). Enamel blocks had their surface polished and surface hardness determined (SH). Next, they were submitted to subsurface enamel demineralization and to post-demineralization surface hardness analysis. The blocks were divided into 6 experimental groups (n=10): placebo (without F, pH 4.5, negative control), 275, 412, 550, 1,100 µgF/g and a standard dentifrice (positive control). The blocks were submitted to pH cycling for 6 days and treatment with dentifrice slurries twice a day. After pH cycling, surface and cross-sectional hardness were assessed to obtain the percentage of surface hardness recovery (%SHR) and the integrated loss of subsurface hardness (ΔKHN). The results showed that %SHR was similar among acidic dentifrices with 412, 550, 1,100 µgF/g and to the positive control (Tukey's test; p>0.05). For ΔKHN, the acidic dentifrice with 550 µg F/g showed a better performance when compared with the positive control. It can be concluded that acidic dentifrice 550 µgF/g had similar remineralization capacity to that of positive control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: This in vitro study analysed the effect of different fluoride concentrations in acidic or neutral liquid dentifrices in protecting enamel and dentine from erosive and abrasive wear. Methods: Bovine enamel and dentine specimens (n = 132) were randomly allocated to 11 groups (each n = 12): experimental liquid dentifrices with 550 ppm F, 1100 ppm F, 5000 ppm F or 0 ppm F/placebo (each at pH 4.5 and pH 7.0); and commercial dentifrices with 550 ppm F (Colgate Baby, pH 7.0), 1100 ppm F (Crest, pH 7.0) and 5000 ppm F (Duraphat, pH 7.0). The specimens were subjected to erosion for 90 seconds, 4 times/day, over 7 days. Immediately after the first and last erosion, the specimens were brushed for 15 seconds using one of the dentifrices. Tooth wear was measured profilometrically (lm) and analysed by ANOVA (p < 0.05). Results: All fluoridated liquid dentifrices significantly reduced enamel wear compared to the placebo and commercial dentifrices. Only liquid dentifrices with 1100 and 5000 ppm F significantly reduced dentine wear compared to placebo dentifrice. The pH had no effect, but the consistency had a significant impact on the effect of dentifrices. Conclusions: Liquid dentifrices with high F concentration appear to be a good option to prevent tooth wear

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Stimulation of salivary flow is considered a preventive strategy for dental erosion. Alternatively, products containing calcium phosphate, such as a complex of casein phosphopeptide–amorphous calcium phosphate (CPP–ACP), have also been tested against dental erosion. Therefore, this in situ study analyzed the effect of chewing gum containing CPP–ACP on the mineral precipitation of initial bovine enamel erosion lesions. Methods: Twelve healthy adult subjects wore palatal appliances with two eroded bovine enamel samples. The erosion lesions were produced by immersion in 0.1% citric acid (pH 2.5) for 7 min. During three experimental crossover in situ phases (1 day each), the subjects chewed a type of gum, 3 times for 30 min, in each phase: with CPP–ACP (trident total), without CPP–ACP (trident), and no chewing gum (control). The Knoop surface microhardness was measured at baseline, after erosion in vitro and the mineral precipitation in situ. The differences in the degree of mineral precipitation were analyzed using repeated measures (RM-) ANOVA and post hoc Tukey’s test ( p < 0.05). Results: Significant differences were found among the remineralizing treatments ( p < 0.0001). Chewing gum (19% of microhardness recovery) improved the mineral precipitation compared to control (10%) and the addition of CPP–ACP into the gum promoted the best mineral precipitation effect (30%). Conclusions: Under this protocol, CPP–ACP chewing gum improved the mineral precipitation of eroded enamel. Clinical significance: Since the prevalence of dental erosion is steadily increasing, CPP–ACP chewing gum might be an important strategy to reduce th eprogression of initial erosion lesions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the in vitro changes on the enamel surface after a micro-abrasion treatment promoted by different products. Material and Methods: Fifty (50) fragments of bovine enamel (15 mm × 5 mm) were randomly assigned to five groups (n=10) according to the product utilized: G1 (control)= silicone polisher (TDV), G2= 37% phosphoric acid (3M/ESPE) + pumice stone (SS White), G3= Micropol (DMC Equipment), G4= Opalustre (Ultradent) and G5= Whiteness RM (FGM Dental Products). Roughness and wear were the responsible variables used to analyze these surfaces in four stages: baseline, 60 s and 120 s after the micro-abrasion and after polishing, using a Hommel Tester T1000 device. After the tests, a normal distribution of data was verified, with repeated ANOVA analyses (p?0.05) which were used to compare each product in different stages. One-way ANOVA and Tukey tests were applied for individual comparisons between the products in each stage (p?0.05). Results: Means and standard deviations of roughness and wear (µm) after all the promoted stages were: G1=7.26(1.81)/13.16(2.67), G2=2.02(0.62)/37.44(3.33), G3=1.81(0.91)/34.93(6.92), G4=1.92(0.29)/38.42(0.65) and G5=1.98(0.53)/33.45(2.66). At 60 seconds, all products tended to produce less surface roughness with a variable gradual decrease over time. After polishing, there were no statistically significant differences between the groups, except for G1. Independent of the product utilized, the enamel wear occurred after the micro-abrasion. Conclusions: In this in vitro study, enamel micro-abrasion presented itself as a conservative approach, regardless of the type of the paste compound utilized. These products promoted minor roughness alterations and minimal wear. The use of phosphoric acid and pumice stone showed similar results to commercial products for the micro-abrasion with regard to the surface roughness and wear.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the prevalence, types, location, and characteristics of enamel defects in anterior permanent teeth of patients with complete unilateral and bilateral cleft lip and palate, as well as the relation with the cleft. Setting: Hospital for Rehabilitation of Craniofacial Anomalies, Bauru, São Paulo, Brazil. Participants: Eighty patients of both genders, 12 years and older, with unilateral or bilateral cleft lip and palate. Methods: A single examiner carried out clinical examination under artificial light with a dental probe and mirror after drying teeth according to the modified DDE index. Results: Seventy-four of 80 patients presented with at least one tooth affected by enamel defects: 165 of 325 evaluated teeth (50.8%) presented enamel defects, with hypoplasia being the most prevalent (50.7%), followed by diffuse opacity (23.1%) and demarcated opacity (18.4%). The most affected tooth was 21 (36.5%), followed by 11 (34%), located at the middle (40%) and incisal (33%) thirds. Most defects occur at the buccal surface (47.7%), followed by the distal (22.7%), the mesial (19%), and the palatal (10.6%) surfaces. A significant relationship was found between the cleft side and enamel defects. Conclusion: Upper anterior teeth of patients with complete cleft lip and palate present a high prevalence of enamel defects; the highest percentage on the cleft side suggests that the cleft does influence the occurrence of enamel defects in permanent teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O trabalho descrito nesta tese mostra de forma detalhada a fabricação e caracterização de diferentes microssensores eletroquímicos os quais têm sido recentemente utilizados como sondas em grupo de técnicas conhecida como Scanning Electrochemical Probe Microscopy (SEPM). Desta forma, a caracterização de superfícies pode ser feita explorando diferentes fenômenos interfaciais relevantes à Ciência. Neste sentido, as interfaces de materiais cristalinos como hidroxiapatita (materiais dentários) e calcita foram o foco de estudo neste trabalho. Assim, diferentes técnicas SEPM foram exploradas no sentido de se obter informações relevantes relacionadas aos processos dentários, como a erosão ácida e hipersensibilidade. Inicialmente, microeletrodos de platina foram desenvolvidos empregando uma metodologia convencional na qual são utilizados microfibras encapsuladas em capilares de vidro. Scanning Electrochemical Microscopy (SECM) no modo amperométrico foi utilizada para obtenção de informações com relação às alterações de topografia do esmalte dentário causadas pelo contato com substâncias ácidas. Adicionalmente, SECM foi empregada no estudo do transporte de espécies eletroativas em amostras de dentina e investigações relacionadas ao bloqueio dos túbulos empregando-se cremes dentais comerciais foram realizadas. A permeação de peróxido de hidrogênio pela dentina também foi estudada. Os resultados de SECM foram comparados com imagens SEM obtidas nas mesmas condições experimentais. Microeletrodos de membrana ionófora íon-seletiva (Ion Selective Microelectrodes-ISMEs) sensíveis a íons cálcio também foram desenvolvidos e caracterizados, com subsequente aplicação em SECM no modo potenciométrico. A dissolução ácida de esmalte bovino (erosão dentária) foi investigada em diferentes valores de pH (2,5; 4,5; 6,8). Além disso, o transporte de íons cálcio através de membranas porosas sintéticas foi avaliado a uma distância tip/substrato de 300µm. Alterações no fluxo de íons cálcio foram correlacionadas em experimentos realizados na presença e ausência de campos magnéticos gerados por nanopartículas de magnetita incorporadas à membrana porosa. Microcristais de calcita facilmente sintetizados pelo método de precipitação foram utilizados como superfície modelo para investigações interfaciais, cujos resultados podem ser correlacionados aos materiais dentários. Desta forma, nanopipetas de vidro preenchidas com eletrólito suporte foram fabricadas e utilizadas como sonda em Scanning Ion Conductance Microscopy (SICM). O mapeamento topográfico de alta resolução espacial da superfície de um microcristal de calcita foi obtido utilizando o modo de varredura hopping mode. Adicionalmente, sondas multifuncionais ISME-SICM também foram desenvolvidas e caracterizadas para investigações simultâneas com relação às alterações topográficas e quantificação de íons cálcio sobre a superfície de um microcristal de calcita. A adição de reagentes ácidos no canal SICM promoveu a dissolução da superfície do microcristal, sendo obtidos dados cinéticos de dissolução. Investigações em meio neutro também foram realizadas utilizando a sonda ISME-SICM. Os resultados experimentais obtidos também foram comparados com aqueles oriundos de simulação computacional.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chalcolithic diet at Perdigões (Reguengos de Monsaraz) was investigated using stable carbon and nitrogen isotope analysis of human bone collagen. Strontium isotopes of faunal dental enamel were used to establish the site local range and to distinguish the presence of non-local individuals. ATR-FTIR and EA analysis were used to determine the degree of bone diagenesis and to evaluate the reliability of the stable isotopic composition for paleodietary reconstruction. The individuals from which paleodietary results were obtained had a diet based on C3 terrestrial resources and some animal protein. Data from Perdigões site, was compared with the published data from other Iberian Chalcolithic populations. Site comparison revealed that diet through Iberian Peninsula have mainly maintained terrestrial dietary focus consistent with animal husbandry and farming on C3 plants with occasional intake of freshwater or marine resources. Strontium isotopic composition of enamel revealed that some of the individuals from Perdigões site were non-local; Resumo: A dieta de indivíduos do período Calcolítico dos Perdigões (Reguengos de Monsaraz) foi investigada através de análise de isótopos estáveis de carbono e azoto no colagénio ósseo. Isótopos de estrôncio do esmalte dentário de fauna foram utilizados para estabelecer o sinal local dos Perdigões, permitindo distinguir a presença de alguns indivíduos e fauna não-locais. A avaliação da diagénese óssea foi efectuada através de análises realizadas com analisador elementar e com ATR-FTIR, de forma a validar dos resultados isotópicos obtidos. Os indivíduos para os quais foi possivel obter resultados isotópicos de carbono e azoto apresentam uma dieta baseada em recursos terrestres, plantas C3, e alguma proteína animal. A comparação efectuada com outros sitios arqueológicos da Peninsula Ibérica revelaram que a dieta das populações é sobretudo feita à base de plantas C3, com ingestão de alguma proteina animal e ingestão ocasional de produtos marinhos ou provenientes de água doce.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)