516 resultados para ENTERAL STENTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The differential safety and efficacy profiles of sirolimus-eluting stents when implanted in patients with multivessel coronary artery disease who have increased body mass indexes (BMIs) compared with those with normal BMIs are largely unknown. This study evaluated the impact of BMI on 1-year outcomes in patients with multivessel coronary artery disease treated with sirolimus-eluting stents as part of the Arterial Revascularization Therapies Study Part II (ARTS II). From February to November 2003, 607 patients were included at 45 centers; 176 patients had normal BMIs (<25 kg/m(2)), 289 were overweight (> or =25 and < or =30 kg/m(2)), and 142 were obese (>30 kg/m(2)). At 30 days, the cumulative incidence of the primary combined end point of death, myocardial infarction, cerebrovascular accident, and repeat revascularization (major adverse cardiac and cerebrovascular events) was 3.4% in the group with normal BMIs, 3.1% in overweight patients, and 2.8% in obese patients (p = 0.76). At 1 year, the cumulative incidence of major adverse cardiac and cerebrovascular events was 10.8%, 11.8%, and 7.0% in the normal BMI, overweight, and obese groups, respectively (p = 0.31). In conclusion, BMI had no impact on 1-year clinical outcomes in patients with multivessel coronary artery disease treated with sirolimus-eluting stents in ARTS II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point. Results 35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes. Conclusion In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Diabetes mellitus (DM) plays an important role in the development of coronary artery disease. Although previous studies have associated drug-eluting stent (DES) implantation in diabetic patients with favourable clinical and angiographic outcomes, the very long-term efficacy of these devices in diabetic patients undergoing PCI for significant unprotected left main coronary artery (ULMCA) disease has not been established yet. METHODS AND RESULTS: Consecutive diabetic patients (n=100), who underwent elective PCI with DES for de novo lesions in an ULMCA between April 2002 and April 2004 in seven tertiary health care centres, were identified retrospectively and analysed. Consecutive non-diabetic patients (n=193), who underwent elective DES implantation for unprotected ULMCA disease, were selected as a control group. All patients were followed for at least 36 months. At 3-years follow-up, freedom from cardiac death ; myocardial infarction (CDMI), target lesion revascularisation (TLR) and target vessel revascularisation (TVR) did not differ significantly between groups. The adjusted freedom from major adverse cardiac events (MACE, defined as the occurrence of CD, MI or TVR) was 63.4% in the DM group and 77.6% in the controls (p<0.001). When divided into IDDM and NIDDM sub-groups, insulin-dependent DM (IDDM) but not non IDDM (NIDDM) patients had significantly lower freedom from CDMI, TLR, TVR and MACE compared to controls. CONCLUSIONS: These results suggest that major improvements in DES technology and pharmacotherapy are still required to improve clinical outcome and that the decision to perform percutaneous revascularisation in this subset of patients should be taken cautiously and on a case by case basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug-eluting stents (DESs) effectively reduce angiographic restenosis and the clinical need for repeat revascularization procedures as compared with bare-metal stents. Widely publicized concerns arose recently about the incidence of late and very late stent thrombosis with the use of first-generation DESs. Recent systematic reviews and large-scale registry studies demonstrated similar rates of overall mortality and myocardial infarction for patients treated with either DESs or bare-metal stents during long-term follow-up. Careful selection of stent type according to patient and lesion characteristics as well as monitoring of adherence to dual antiplatelet therapy could maximize the therapeutic potential of these devices. The purpose of the present Review is to provide the reader with an overview of the benefits and risks of first-generation DESs that could help physicians select the most appropriate stent type for each patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Polymer as carrier substance for drugeluting stents (DES) has been accused of inducing inflammation and hypersensitivity reactions leading to restenosis and stent thrombosis. Thus, a new paclitaxel-eluting stent (PES) with aminoparylene as a carrier substance is tested in the present study. METHODS: In 10 pigs, stents were implanted in the epicardial coronary arteries: 1) bare-metal stents (BMS, control stent); 2) cobalt-chromium stents (CCS); and 3) PES. Stent length was 15 mm, and diameter was 3 mm. The animals were restudied after 6 weeks. Quantitative coronary angiography was performed at baseline and follow up. Minimum luminal diameter (MLD) and late loss were calculated in all animals. Histologic vessel lumen, intimal proliferation and restenosis were determined by morphometry. Disruption of the lamina elastica interna (LEI) and inflammatory reactions were assessed by histology. RESULTS: The MLD at baseline was 2.83 +/- 0.28 mm, and at follow up it was 2.29 +/- 0.44 (p < 0.05; n = 30). Late loss and angiographic restenosis were smallest in the CCS and largest in the PES (ns). Neointimal proliferation was similar for all 3 stents, ranging between 1.38 and 1.64 mm(2) (ns). There was a significant correlation between disruption of the LEI and inflammatory reactions. CONCLUSIONS: PTs with aminoparylene as a carrier substance show similar late loss and angiographic restenosis to that of BM and CCS. The incidence of inflammatory reactions (35% of all histologic sections) is similar in all stents, but highest in PES. The mechanism of this reaction is unclear, but may be either due to the drug itself, the disruption of the LEI or to a hypersensitivity reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis. RESULTS Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio=0.95, 95% CI=0.74-1.21, P=0.67). Target lesion revascularization was also comparable between the groups (hazard ratio=0.89, 95% CI=0.65-1.22, P=0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio=0.52, 95% CI=0.28-0.96, P=0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4years (hazard ratio=0.15, 95% CI=0.03-0.70, P=0.02). CONCLUSIONS In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4years. Rates of stent thrombosis were significantly lower with BP-DES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Newer generation everolimus-eluting stents (EES) improve clinical outcome compared to early generation sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES). We investigated whether the advantage in safety and efficacy also holds among the high-risk population of diabetic patients during long-term follow-up. METHODS Between 2002 and 2009, a total of 1963 consecutive diabetic patients treated with the unrestricted use of EES (n=804), SES (n=612) and PES (n=547) were followed throughout three years for the occurrence of cardiac events at two academic institutions. The primary end point was the occurrence of definite stent thrombosis. RESULTS The primary outcome occurred in 1.0% of EES, 3.7% of SES and 3.8% of PES treated patients ([EES vs. SES] adjusted HR=0.58, 95% CI 0.39-0.88; [EES vs. PES] adjusted HR=0.29, 95% CI 0.13-0.67). Similarly, patients treated with EES had a lower risk of target-lesion revascularization (TLR) compared to patients treated with SES and PES ([EES vs. SES], 5.6% vs. 11.5%, adjusted HR=0.68, 95% CI: 0.55-0.83; [EES vs. PES], 5.6% vs. 11.3%, adjusted HR=0.51, 95% CI: 0.33-0.77). There were no differences in other safety end points, such as all-cause mortality, cardiac mortality, myocardial infarction (MI) and MACE. CONCLUSION In diabetic patients, the unrestricted use of EES appears to be associated with improved outcomes, specifically a significant decrease in the need for TLR and ST compared to early generation SES and PES throughout 3-year follow-up.