975 resultados para Dynamic-response
Resumo:
There are many the requirements that modern power converters should fulfill. Most of the applications where these converters are used, demand smaller converters with high efficiency, improved power density and a fast dynamic response. For instance, loads like microprocessors demand aggressive current steps with very high slew rates (100A/mus and higher); besides, during these load steps, the supply voltage of the microprocessor should be kept within tight limits in order to ensure its correct performance. The accomplishment of these requirements is not an easy task; complex solutions like advanced topologies - such as multiphase converters- as well as advanced control strategies are often needed. Besides, it is also necessary to operate the converter at high switching frequencies and to use capacitors with high capacitance and low ESR. Improving the dynamic response of power converters does not rely only on the control strategy but also the power topology should be suited to enable a fast dynamic response. Moreover, in later years, a fast dynamic response does not only mean accomplishing fast load steps but output voltage steps are gaining importance as well. At least, two applications that require fast voltage changes can be named: Low power microprocessors. In these devices, the voltage supply is changed according to the workload and the operating frequency of the microprocessor is changed at the same time. An important reduction in voltage dependent losses can be achieved with such changes. This technique is known as Dynamic Voltage Scaling (DVS). Another application where important energy savings can be achieved by means of changing the supply voltage are Radio Frequency Power Amplifiers. For example, RF architectures based on ‘Envelope Tracking’ and ‘Envelope Elimination and Restoration’ techniques can take advantage of voltage supply modulation and accomplish important energy savings in the power amplifier. However, in order to achieve these efficiency improvements, a power converter with high efficiency and high enough bandwidth (hundreds of kHz or even tens of MHz) is necessary in order to ensure an adequate supply voltage. The main objective of this Thesis is to improve the dynamic response of DC-DC converters from the point of view of the power topology. And the term dynamic response refers both to the load steps and the voltage steps; it is also interesting to modulate the output voltage of the converter with a specific bandwidth. In order to accomplish this, the question of what is it that limits the dynamic response of power converters should be answered. Analyzing this question leads to the conclusion that the dynamic response is limited by the power topology and specifically, by the filter inductance of the converter which is found in series between the input and the output of the converter. The series inductance is the one that determines the gain of the converter and provides the regulation capability. Although the energy stored in the filter inductance enables the regulation and the capability of filtering the output voltage, it imposes a limitation which is the concern of this Thesis. The series inductance stores energy and prevents the current from changing in a fast way, limiting the slew rate of the current through this inductor. Different solutions are proposed in the literature in order to reduce the limit imposed by the filter inductor. Many publications proposing new topologies and improvements to known topologies can be found in the literature. Also, complex control strategies are proposed with the objective of improving the dynamic response in power converters. In the proposed topologies, the energy stored in the series inductor is reduced; examples of these topologies are Multiphase converters, Buck converter operating at very high frequency or adding a low impedance path in parallel with the series inductance. Control techniques proposed in the literature, focus on adjusting the output voltage as fast as allowed by the power stage; examples of these control techniques are: hysteresis control, V 2 control, and minimum time control. In some of the proposed topologies, a reduction in the value of the series inductance is achieved and with this, the energy stored in this magnetic element is reduced; less stored energy means a faster dynamic response. However, in some cases (as in the high frequency Buck converter), the dynamic response is improved at the cost of worsening the efficiency. In this Thesis, a drastic solution is proposed: to completely eliminate the series inductance of the converter. This is a more radical solution when compared to those proposed in the literature. If the series inductance is eliminated, the regulation capability of the converter is limited which can make it difficult to use the topology in one-converter solutions; however, this topology is suitable for power architectures where the energy conversion is done by more than one converter. When the series inductor is eliminated from the converter, the current slew rate is no longer limited and it can be said that the dynamic response of the converter is independent from the switching frequency. This is the main advantage of eliminating the series inductor. The main objective, is to propose an energy conversion strategy that is done without series inductance. Without series inductance, no energy is stored between the input and the output of the converter and the dynamic response would be instantaneous if all the devices were ideal. If the energy transfer from the input to the output of the converter is done instantaneously when a load step occurs, conceptually it would not be necessary to store energy at the output of the converter (no output capacitor COUT would be needed) and if the input source is ideal, the input capacitor CIN would not be necessary. This last feature (no CIN with ideal VIN) is common to all power converters. However, when the concept is actually implemented, parasitic inductances such as leakage inductance of the transformer and the parasitic inductance of the PCB, cannot be avoided because they are inherent to the implementation of the converter. These parasitic elements do not affect significantly to the proposed concept. In this Thesis, it is proposed to operate the converter without series inductance in order to improve the dynamic response of the converter; however, on the other side, the continuous regulation capability of the converter is lost. It is said continuous because, as it will be explained throughout the Thesis, it is indeed possible to achieve discrete regulation; a converter without filter inductance and without energy stored in the magnetic element, is capable to achieve a limited number of output voltages. The changes between these output voltage levels are achieved in a fast way. The proposed energy conversion strategy is implemented by means of a multiphase converter where the coupling of the phases is done by discrete two-winding transformers instead of coupledinductors since transformers are, ideally, no energy storing elements. This idea is the main contribution of this Thesis. The feasibility of this energy conversion strategy is first analyzed and then verified by simulation and by the implementation of experimental prototypes. Once the strategy is proved valid, different options to implement the magnetic structure are analyzed. Three different discrete transformer arrangements are studied and implemented. A converter based on this energy conversion strategy would be designed with a different approach than the one used to design classic converters since an additional design degree of freedom is available. The switching frequency can be chosen according to the design specifications without penalizing the dynamic response or the efficiency. Low operating frequencies can be chosen in order to favor the efficiency; on the other hand, high operating frequencies (MHz) can be chosen in order to favor the size of the converter. For this reason, a particular design procedure is proposed for the ‘inductorless’ conversion strategy. Finally, applications where the features of the proposed conversion strategy (high efficiency with fast dynamic response) are advantageus, are proposed. For example, in two-stage power architectures where a high efficiency converter is needed as the first stage and there is a second stage that provides the fine regulation. Another example are RF power amplifiers where the voltage is modulated following an envelope reference in order to save power; in this application, a high efficiency converter, capable of achieving fast voltage steps is required. The main contributions of this Thesis are the following: The proposal of a conversion strategy that is done, ideally, without storing energy in the magnetic element. The validation and the implementation of the proposed energy conversion strategy. The study of different magnetic structures based on discrete transformers for the implementation of the proposed energy conversion strategy. To elaborate and validate a design procedure. To identify and validate applications for the proposed energy conversion strategy. It is important to remark that this work is done in collaboration with Intel. The particular features of the proposed conversion strategy enable the possibility of solving the problems related to microprocessor powering in a different way. For example, the high efficiency achieved with the proposed conversion strategy enables it as a good candidate to be used for power conditioning, as a first stage in a two-stage power architecture for powering microprocessors.
Resumo:
The objective of this paper is to analyse the influence of the variation of some parameters used in the analysis of the dynamic response of offshore structures under the action of wind generated waves. The structural response has been obtained by stochastic methods using two discretization models. One with lumped parameters, using translational degrees of freedom (d.o.f.) and the other with one-dimensional finite elements. Using each of these methods the problem has been solved with several d.o.f., analysing the influence of the number of d.o.f. on the results.
Resumo:
La vía tradicional sobre balasto sigue siendo una selección para las líneas de alta velocidad a pesar de los problemas técnicos y la prestación del funcionamiento. El problema de la vía sobre balasto es el proceso continuo del deterioro de éste debido a las cargas asociadas al tráfico ferroviario. En consecuencia es imprescindible un mantenimiento continuado para mantener un alineamiento adecuado de la vía. Por eso se surge la necesidad de comprender mejor el mecanismo involucrado en el deterioro de la vía y los factores claves que rigen su progresión a lo largo de ciclos de carga con el fin de reducir los costos del mantenimiento de la vía y mejorar el diseño de las nuevas vías. La presente tesis intenta por un lado desarrollar los modelos más adecuados y eficientes del vehículo y de la vía para los cálculos de los efectos dinámicos debido al tráfico de ferrocarril sobre la infraestructura de la vía sobre balasto, y por otro evaluar estos efectos dinámicos sobre el deterioro de la vía sobre balasto a largo plazo, empleando un adecuado modelo de predicción del deterioro de la misma. Se incluye en el trabajo una recopilación del estado del arte en lo referente a la dinámica de la vía, a la modelización del vehículo, de la vía y de la interacción entre ambos. También se hace un repaso al deterioro de la vía y los factores que influyen en su proceso. Para la primera línea de investigación de esta tesis, se han desarrollado los diferentes modelos del vehículo y de la vía y la modelización de la interacción entre ambos para los cálculos dinámicos en dos y tres dimensiones. En la interacción vehículo-vía, se ha empleado la formulación de contacto nodo-superficie para establecer la identificación de las superficies en contacto y el método de los multiplicadores de Lagrange para imponer las restricciones de contacto. El modelo de interacción se ha contrastado con los casos reportados en la literatura. Teniendo en cuenta el contacto no lineal entre rueda-carril y los perfiles de irregularidades distribuidas de la vía, se han evaluado y comparado los efectos dinámicos sobre el sistema vehículo-vía en la interacción de ambos, para distintas velocidades de circulación del vehículo, en los aspectos como la vibración del vehículo, fuerza de contacto, fuerza transmitida en los railpads, la vibración del carril. También se hace un estudio de la influencia de las propiedades de los componentes de la vía en la respuesta dinámica del sistema vehículo-vía. Se ha desarrollado el modelo del asiento de la vía que consiste en la implementación del modelo de acumulación de Bochum y del modelo de hipoplasticidad en la subrutina del usuario \UMAT" del programa ABAQUS. La implementación numérica ha sido comprobado al comparar los resultados de las simulaciones numéricas con los reportados en la literatura. Se ha evaluado la calidad geométrica de la vía sobre balasto de los tramos de estudio con datos reales de la auscultación proporcionados por ADIF (2012). Se ha propuesto una metodología de simulación, empleando el modelo de asiento, para reproducir el deterioro de la geometría de la vía. Se usan los perfiles de la nivelación longitudinal de la auscultación como perfiles de irregularidades iniciales de la vía en las simulaciones numéricas. También se evalúa la influencia de la velocidad de circulación sobre el deterioro de la vía. The traditional ballast track structures are still being used in high speed railways lines with success, however technical problems or performance features have led to ballast track solution in some cases. The considerable maintenance work is needed for ballasted tracks due to the track deterioration. Therefore it is very important to understand the mechanism of track deterioration and to predict the track settlement or track irregularity growth rate in order to reduce track maintenance costs and enable new track structures to be designed. This thesis attempts to develop the most adequate and efficient models for calculation of dynamic track load effects on railways track infrastructure, and to evaluate these dynamic effects on the track settlement, using a track settlement prediction model, which consists of the vehicle/track dynamic model previously selected and a track settlement law. A revision of the state of the knowledge regarding the track dynamics, the modelling of the vehicle, the track and the interaction between them is included. An overview related to the track deterioration and the factors influencing the track settlement is also done. For the first research of this thesis, the different models of vehicle, track and the modelling of the interaction between both have been developed. In the vehicle-track interaction, the node-surface contact formulation to establish the identification of the surfaces in contact and the Lagrange multipliers method to enforce contact constraint are used. The interaction model has been verified by contrast with some benchmarks reported in the literature. Considering the nonlinear contact between wheel-rail and the track irregularities, the dynamic effects on the vehicle-track system have been evaluated and compared, for different speeds of the vehicle, in aspects as vehicle vibration, contact force, force transmitted in railpads, rail vibration. A study of the influence of the properties of the track components on the the dynamic response of the vehicle-track system has been done. The track settlement model is developed that consist of the Bochum accumulation model and the hipoplasticity model in the user subroutine \UMAT" of the program ABAQUS. The numerical implementation has been verified by comparing the numerical results with those reported in the literature. The geometric quality of the ballast track has been evaluated with real data of auscultation provided by ADIF (2012). The simulation methodology has been proposed, using the settlement model for the ballast material, to reproduce the deterioration of the track geometry. The profiles of the longitudinal level of the auscultation is used as initial profiles of the track irregularities in the numerical simulation. The influence of the running speed on the track deterioration is also investigated.
Resumo:
This paper presents a time-domain stochastic system identification method based on maximum likelihood estimation (MLE) with the expectation maximization (EM) algorithm. The effectiveness of this structural identification method is evaluated through numerical simulation in the context of the ASCE benchmark problem on structural health monitoring. The benchmark structure is a four-story, two-bay by two-bay steel-frame scale model structure built in the Earthquake Engineering Research Laboratory at the University of British Columbia, Canada. This paper focuses on Phase I of the analytical benchmark studies. A MATLAB-based finite element analysis code obtained from the IASC-ASCE SHM Task Group web site is used to calculate the dynamic response of the prototype structure. A number of 100 simulations have been made using this MATLAB-based finite element analysis code in order to evaluate the proposed identification method. There are several techniques to realize system identification. In this work, stochastic subspace identification (SSI)method has been used for comparison. SSI identification method is a well known method and computes accurate estimates of the modal parameters. The principles of the SSI identification method has been introduced in the paper and next the proposed MLE with EM algorithm has been explained in detail. The advantages of the proposed structural identification method can be summarized as follows: (i) the method is based on maximum likelihood, that implies minimum variance estimates; (ii) EM is a computational simpler estimation procedure than other optimization algorithms; (iii) estimate more parameters than SSI, and these estimates are accurate. On the contrary, the main disadvantages of the method are: (i) EM algorithm is an iterative procedure and it consumes time until convergence is reached; and (ii) this method needs starting values for the parameters. Modal parameters (eigenfrequencies, damping ratios and mode shapes) of the benchmark structure have been estimated using both the SSI method and the proposed MLE + EM method. The numerical results show that the proposed method identifies eigenfrequencies, damping ratios and mode shapes reasonably well even in the presence of 10% measurement noises. These modal parameters are more accurate than the SSI estimated modal parameters.
Resumo:
A large number of reinforced concrete (RC) frame structures built in earthquake-prone areas such as Haiti are vulnerable to strong ground motions. Structures in developing countries need low-cost seismic retrofit solutions to reduce their vulnerability. This paper investigates the feasibility of using masonry infill walls to reduce deformations and damage caused by strong ground motions in brittle and weak RC frames designed only for gravity loads. A numerical experiment was conducted in which several idealized prototypes representing RC frame structures of school buildings damaged during the Port-au-Prince earthquake (Haiti, 2010) were strengthened by adding elements representing masonry infill walls arranged in different configurations. Each configuration was characterized by the ratio Rm of the area of walls in the direction of the ground motion (in plan) installed in each story to the total floor area. The numerical representations of these idealized RC frame structures with different values of Rm were (hypothetically) subjected to three major earthquakes with peak ground accelerations of approximately 0.5g. The results of the non-linear dynamic response analyses were summarized in tentative relationships between Rm and four parameters commonly used to characterize the seismic response of structures: interstory drift, Park and Ang indexes of damage, and total amount of energy dissipated by the main frame. It was found that Rm=4% is a reasonable minimum design value for seismic retrofitting purposes in cases in which available resources are not sufficient to afford conventional retrofit measures.
Resumo:
This paper addresses the seismic analysis of a deeply embedded non-slender structure hosting the pumping unit of a reservoir. The dynamic response in this type of problems is usually studied under the assumption of a perfectly rigid structure using a sub-structuring procedure (three-step solution) proposed specifically for this hypothesis. Such an approach enables a relatively simple assessment of the importance of some key factors influencing the structural response. In this work, the problem is also solved in a single step using a direct approach in which the structure and surrounding soil are modelled as a coupled system with its actual geometry and flexibility. Results indicate that, quite surprisingly, there are significant differences among prediction using both methods. Furthermore, neglecting the flexibility of the structure leads to a significant underestimation of the spectral accelerations at certain points of the structure.
Resumo:
The city of Lorca (Spain) was hit on May 11th 2011 by two consecutive earthquakes with 4.6 and 5.2 Mw respectively, causing casualties and important damage in buildings. Lorca is located in the south-east region of Spain and settled on the trace of the Murcia-Totana-Lorca fault. Although the magnitudes of these ground motions were not severe, the damage observed was considerable over a great amount of buildings. More than 300 of them have been demolished and many others are being retrofitted. This paper reports a field study on the damage caused by these earthquakes. The observed damage is related with the structural typology. Further, prototypes of the damaged buildings are idealized with nonlinear numerical models and their seismic behavior and proneness to damage concentration is further investigated through dynamic response analyses.
Resumo:
En este proyecto se van a aplicar las técnicas de análisis de ruido para caracterizar la respuesta dinámica de varios sensores de temperatura, tanto termorresistencias de platino como de termopares. Estos sensores son imprescindibles para él correcto funcionamiento de las centrales nucleares y requieren vigilancia para garantizar la exactitud de las medidas. Las técnicas de análisis de ruido son técnicas pasivas, es decir, no afectan a la operación de la planta y permiten realizar una vigilancia in situ de los sensores. Para el caso de los sensores de temperatura, dado que se pueden asimilar a sistemas de primer orden, el parámetro fundamental a vigilar es el tiempo de respuesta. Éste puede obtenerse para cada una de las sondas por medio de técnicas en el dominio de la frecuencia (análisis espectral) o por medio de técnicas en el dominio del tiempo (modelos autorregresivos). Además de la estimación del tiempo de respuesta, se realizará una caracterización estadística de las sondas. El objetivo es conocer el comportamiento de los sensores y vigilarlos de manera que se puedan diagnosticar las averías aunque éstas estén en una etapa incipiente. ABSTRACT In this project we use noise analysis technique to study the dynamic response of RTDs (Resistant temperature detectors) and thermocouples. These sensors are essential for the proper functioning of nuclear power plants and therefore need to be monitored to guarantee accurate measurements. The noise analysis techniques do not affect plant operation and allow in situ monitoring of the sensors. Temperature sensors are equivalent to first order systems. In these systems the main parameter to monitor is the response time which can be obtained by means of techniques in the frequency domain (spectral analysis) as well as time domain (autoregressive models). Besides response time estimation the project will also include a statistical study of the probes. The goal is to understand the behavior of the sensors and monitor them in order to detect any anomalies or malfunctions even if they occur in an early stage.
Resumo:
In this work, a methodology is proposed to find the dynamics poles of a capacitive pressure transmitter in order to enhance and extend the on line surveillance of this type of sensors based on the response time measurement by applying noise analysis techniques and the Dynamic Data System. Several measurements have been analyzed taken from a Pressurized Water Reactor. The methodology proposes an autoregressive fit whose order is determined by the sensor dynamics poles. Nevertheless, the signals that have been analyzed, could not be filtered properly in order to remove the plant noise, thus, this was considered as an additional pair of complex conjugate poles. With this methodology we have come up with the numerical value of the sensor second real pole in spite of its low influence on the sensor dynamic response. This opens up a more accurate on line sensor surveillance since the previous methods were achieved by considering one real pole only.
Resumo:
The combination of minimum time control and multiphase converter is a favorable option for dc-dc converters in applications where output voltage variation is required, such as RF amplifiers and dynamic voltage scaling in microprocessors, due to their advantage of fast dynamic response. In this paper, an improved minimum time control approach for multiphase buck converter that is based on charge balance technique, aiming at fast output voltage transition is presented. Compared with the traditional method, the proposed control takes into account the phase delay and current ripple in each phase. Therefore, by investigating the behavior of multiphase converter during voltage transition, it resolves the problem of current unbalance after the transient, which can lead to long settling time of the output voltage. The restriction of this control is that the output voltage that the converter can provide is related to the number of the phases, because only the duty cycles at which the multiphase converter has total ripple cancellation are used in this approach. The model of the proposed control is introduced, and the design constraints of the buck converters filter for this control are discussed. In order to prove the concept, a four-phase buck converter is implemented and the experimental results that validate the proposed control method are presented. The application of this control to RF envelope tracking is also presented in this paper.
Resumo:
The bandwidth achievable by using voltage mode control or current mode control in switch-mode power supply is limited by the switching frequency. Fast transient response requires high switching frequency, although lower switching frequencies could be more suitable for higher efficiency. This paper proposes the use of hysteretic control of the output capacitor $(C_{out})$ current to improve the dynamic response of the buck converter. An external voltage loop is required to accurately regulate the output voltage. The design of the hysteretic loop and the voltage loop are presented. Besides, it is presented a non-invasive current sensor that allows measuring the current in the capacitor. This strategy has been applied for DVS (dynamic voltage scaling) on a 5 MHz buck converter. Experimental results validate the proposed control technique and show fast transient response from 1.5 V to 2.5 V in 2 $mu{rm s}$.
Resumo:
Several boost-derived topologies are analyzed and compared for an aerospace application that uses a 100 V voltage bus. All these topologies have been designed and optimized considering the electrical requirements and the reduced number of space-qualified components. The comparison evaluates the power losses, mass, and dynamic response. Special attention has been paid to those topologies that may cancel the inherent right half plane zero (RHP) zero of the boost topology. Experimental results of the less common topologies are presented.
Resumo:
Ripple-based controls can strongly reduce the required output capacitance in PowerSoC converter thanks to a very fast dynamic response. Unfortunately, these controls are prone to sub-harmonic oscillations and several parameters affect the stability of these systems. This paper derives and validates a simulation-based modeling and stability analysis of a closed-loop V 2Ic control applied to a 5 MHz Buck converter using discrete modeling and Floquet theory to predict stability. This allows the derivation of sensitivity analysis to design robust systems. The work is extended to different V 2 architectures using the same methodology.
Resumo:
El presente proyecto desarrolla el diseño de un sistema de pitch pasivo para aerogeneradores en entornos urbanos en el marco del proyecto SWIP (Soluciones, componentes y herramientas novedosos e innovadores para la integración de la energía eólica en áreas urbanas y suburbanas) En primer lugar se describe el marco de trabajo así como una introducción teórica de energía eólica y de sistemas de pitch o de control de paso de pala. Aquí son presentados los fundamentos del accionamiento del pitch pasivo diseñado. A continuación se presenta el mecanismo diseñado y los cálculos sobre él efectuados para el ajuste de sus parámetros de funcionamiento. Posteriormente se plantea el análisis estructural de los distintos casos de carga a los que estará sometido y el estudio de su respuesta dinámica a perturbaciones reales con las que trabajará durante su funcionamiento normal. Por último, se aclaran otra serie de factores como la seguridad y el sobredimensionamiento del generador y se hace un análisis económico del diseño junto con una comparativa con las tecnologías alternativas existentes. ABSTRACT The present project develops the design of a passive pitch system for wind turbines for urban and sub-urban areas for the SWIP European Project (New innovative solutions, components and tools for the integration of wind energy in urban and peri-urban áreas) Firstly, the framework is described, as well as a theoretical introduction to wind energy and pitch systems. Here, the principles of the designed passive pitch mechanism are presented. Subsequently, the designed mechanism is presented together with the calculations on it for the adjustment of its working parameters. After that, the structural analyses for the different load cases that will affect the design are studied. Afterwards, the dynamic response of the system to real perturbations during its operation is studied. Finally, some concepts concerning security issues or oversizing of the electric generator are considered and an economic analysis is performed for the design and also to compare it with the alternative existing technologies.
Resumo:
El principal objetivo de este trabajo es aportar conocimiento para contestar la pregunta: ¿hasta que punto los ensayos en túnel aerodinámico pueden contribuir a determinar las características que afectan la respuesta dinámica de los aerogeneradores operando en terreno complejo?. Esta pregunta no es nueva, de hecho, el debate en la comunidad científica comenzó en el primer tercio del siglo pasado y aún está intensamente vivo. El método generalmente aceptado para enfrentar el mencionado problema consiste en analizar un caso de estudio determinado en el cual se aplican tanto ensayos a escala real como análisis computacionales y ensayos en túnel aerodinámico. Esto no es ni fácil ni barato. Esta es la razón por la cual desde el experimento de Askervein en 1988, los modelizadores del flujo atmosférico tuvieron que esperar hasta 2007 a que el experimento de Bolund fuese puesto en marcha con un despliegue de medios técnicos equivalentes (teniendo en cuenta la evolución de las tecnologías de sensores y computación). El problema contempla tantos aspectos que ambas experiencias fueron restringidas a condiciones de atmósfera neutra con efectos de Coriolis despreciables con objeto de reducir la complejidad. Este es el contexto en el que se ha desarrollado la presente tesis doctoral. La topología del flujo sobre la isla de Bolund ha sido estudiada mediante la reproducción del experimento de Bolund en los túneles aerodinámicos A9 y ACLA16 del IDR. Dos modelos de la isla de Bolund fueron fabricados a dos escalas, 1:230 y 1:115. El flujo de entrada en el túnel aerodinámico simulando la capa límite sin perturbar correspondía a régimen de transición (transitionally rough regime) y fue usado como situación de referencia. El modelo a escala 1:230 fue ensayado en el túnel A9 para determinar la presión sobre su superficie. La distribución del coeficiente de presión sobre la isla proporcionó una visualización y estimación de una región de desprendimiento sobre el pequeño acantilado situado al frente de la misma. Las medidas de presión instantánea con suficiente grado de resolución temporal pusieron de manifiesto la no estacionariedad en la región de desprendimiento. El modelo a escala 1:115 fue ensayado utilizando hilo caliente de tres componentes y un sistema de velocimetría por imágenes de partículas de dos componentes. El flujo fue caracterizado por el ratio de aceleración, el incremento normalizado de energía cinética turbulenta y los ángulos de inclinación y desviación horizontal. Los resultados a lo largo de la dirección 270°y alturas de 2 m y 5 m presentaron una gran similitud con los resultados a escala real del experimento de Bolund. Los perfiles verticales en las localizaciones de las torres meteorológicas mostraron un acuerdo significativo con los resultados a escala real. El análisis de los esfuerzos de Reynolds y el análisis espectral en las localizaciones de los mástiles meteorológicos presentaron niveles de acuerdo variados en ciertas posiciones, mientras que en otras presentaron claras diferencias. El mapeo horizontal del flujo, para una dirección de viento de 270°, permitió caracterizar el comportamiento de la burbuja intermitente de recirculación sobre el pequeño acantilado existente al frente de la isla así como de la región de relajación y de la capa de cortadura en la región corriente abajo de Bolund. Se realizaron medidas de velocidad con alta resolución espacial en planos perpendiculares a la dirección del flujo sin perturbar. Estas medidas permitieron detectar y caracterizar una estructura de flujo similar a un torbellino longitudinal con regiones con altos gradientes de velocidad y alta intensidad de turbulencia. Esta estructura de flujo es, sin duda, un reto para los modelos computacionales y puede considerarse un factor de riesgo para la operación de los aerogeneradores. Se obtuvieron y analizaron distribuciones espaciales de los esfuerzos de Reynolds mediante 3CHW y PIV. Este tipo de parámetros no constituyen parte de los resultados habituales en los ensayos en túnel sobre topografías y son muy útiles para los modelizadores que utilizan simulación de grades torbellinos (LES). Se proporciona una interpretación de los resultados obtenidos en el túnel aerodinámico en términos de utilidad para los diseñadores de parques eólicos. La evolución y variación de los parámetros del flujo a lo largo de líneas, planos y superficies han permitido identificar como estas propiedades del flujo podrían afectar la localización de los aerogeneradores y a la clasificación de emplazamientos. Los resultados presentados sugieren, bajo ciertas condiciones, la robustez de los ensayos en túnel para estudiar la topología sobre terreno complejo y su comparabilidad con otras técnicas de simulación, especialmente considerando el nivel de acuerdo del conjunto de resultados presentados con los resultados a escala real. De forma adicional, algunos de los parámetros del flujo obtenidos de las medidas en túnel son difícilmente determinables en ensayos a escala real o por medios computacionales, considerado el estado del arte. Este trabajo fue realizado como parte de las actividades subvencionadas por la Comisión Europea como dentro del proyecto FP7-PEOPLE-ITN-2008WAUDIT (Wind Resource Assessment Audit and Standardization) dentro de la FP7 Marie-Curie Initial Training Network y por el Ministerio Español de Economía y Competitividad dentro del proyecto ENE2012-36473, TURCO (Determinación en túnel aerodinámico de la distribución espacial de parámetros estadísticos de la turbulencia atmosférica sobre topografías complejas) del Plan Nacional de Investigación (Subprograma de investigación fundamental no orientada 2012). El informe se ha organizado en siete capítulos y un conjunto de anexos. En el primer capítulo se introduce el problema. En el capítulo dos se describen los medios experimentales utilizados. Seguidamente, en el capítulo tres, se analizan en detalle las condiciones de referencia del principal túnel aerodinámico utilizado en esta investigación. En el capítulo tres se presentan resultados de ensayos de presión superficial sobre un modelo de la isla. Los principales resultados del experimento de Bolund se reproducen en el capítulo cinco. En el capítulo seis se identifican diferentes estructuras del flujo sobre la isla y, finalmente, en el capitulo siete, se recogen las conclusiones y una propuesta de lineas de trabajo futuras. ABSTRACT The main objective of this work is to contribute to answer the question: to which extend can the wind tunnel testing contribute to determine the flow characteristics that affect the dynamic response of wind turbines operating in highly complex terrains?. This question is not new, indeed, the debate in the scientific community was opened in the first third of the past century and it is still intensely alive. The accepted approach to face this problem consists in analysing a given case study where full-scale tests, computational modelling and wind tunnel testing are applied to the same topography. This is neither easy nor cheap. This is is the reason why since the Askervein experience in 1988, the atmospheric flow modellers community had to wait till 2007 when the Bolund experiment was setup with a deployment of technical means equivalent (considering the evolution of the sensor and computing techniques). The problem is so manifold that both experiences were restricted to neutral conditions without Coriolis effects in order to reduce the complexity. This is the framework in which this PhD has been carried out. The flow topology over the Bolund Island has been studied by replicating the Bolund experiment in the IDR A9 and ACLA16 wind tunnels. Two mock-ups of the Bolund island were manufactured at two scales of 1:230 and 1:115. The in-flow in the empty wind tunnel simulating the incoming atmospheric boundary layer was in the transitionally rough regime and used as a reference case. The 1:230 model was tested in the A9 wind tunnel to measure surface pressure. The mapping of the pressure coefficient across the island gave a visualisation and estimation of a detachment region on the top of the escarpment in front of the island. Time resolved instantaneous pressure measurements illustrated the non-steadiness in the detachment region. The 1:115 model was tested using 3C hot-wires(HW) and 2C Particle Image Velocimetry(PIV). Measurements at met masts M3, M6, M7 and M8 and along Line 270°were taken to replicate the result of the Bolund experiment. The flow was characterised by the speed-up ratio, normalised increment of the turbulent kinetic energy, inclination angle and turning angle. Results along line 270°at heights of 2 m and 5 m compared very well with the full-scale results of the Bolund experiment. Vertical profiles at the met masts showed a significant agreement with the full-scale results. The analysis of the Reynolds stresses and the spectral analysis at the met mast locations gave a varied level of agreement at some locations while clear mismatch at others. The horizontal mapping of the flow field, for a 270°wind direction, allowed to characterise the behaviour of the intermittent recirculation bubble on top of the front escarpment followed by a relaxation region and the presence of a shear layer in the lee side of the island. Further detailed velocity measurements were taken at cross-flow planes over the island to study the flow structures on the island. A longitudinal vortex-like structure with high mean velocity gradients and high turbulent kinetic energy was characterised on the escarpment and evolving downstream. This flow structure is a challenge to the numerical models while posing a threat to wind farm designers when siting wind turbines. Spatial distribution of Reynold stresses were presented from 3C HW and PIV measurements. These values are not common results from usual wind tunnel measurements and very useful for modellers using large eddy simulation (LES). An interpretation of the wind tunnel results in terms of usefulness to wind farm designers is given. Evolution and variation of the flow parameters along measurement lines, planes and surfaces indicated how the flow field could affect wind turbine siting. Different flow properties were presented so compare the level of agreement to full-scale results and how this affected when characterising the site wind classes. The results presented suggest, under certain conditions, the robustness of the wind tunnel testing for studying flow topology over complex terrain and its capability to compare to other modelling techniques especially from the level of agreement between the different data sets presented. Additionally, some flow parameters obtained from wind tunnel measurements would have been quite difficult to be measured at full-scale or by computational means considering the state of the art. This work was carried out as a part of the activities supported by the EC as part of the FP7- PEOPLE-ITN-2008 WAUDIT project (Wind Resource Assessment Audit and Standardization) within the FP7 Marie-Curie Initial Training Network and by the Spanish Ministerio de Economía y Competitividad, within the framework of the ENE2012-36473, TURCO project (Determination of the Spatial Distribution of Statistic Parameters of Flow Turbulence over Complex Topographies in Wind Tunnel) belonging to the Spanish National Program of Research (Subprograma de investigación fundamental no orientada 2012). The report is organised in seven chapters and a collection of annexes. In chapter one, the problem is introduced. In chapter two the experimental setup is described. Following, in chapter three, the inflow conditions of the main wind tunnel used in this piece of research are analysed in detail. In chapter three, preliminary pressure tests results on a model of the island are presented. The main results from the Bolund experiment are replicated in chapter five. In chapter six, an identification of specific flow strutures over the island is presented and, finally, in chapter seven, conclusions and lines for future works related to the presented one are included.