952 resultados para Dynamic simulation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The city of Natal has a significant daylight availability, although it use isn’t systematically explored in schools architecture. In this context, this research aims to determine procedures for the analysis of the daylight performance in school design in Natal-RN. The method of analysis is divided in Visible Sky Factor (VSF), simulating and analyzing the results. The annual variation of the daylight behavior requires the adoption of dynamic simulation as data procedure. The classrooms were modelled in SketchUp, simulated in Daysim program and the results were assessed by means of spreadsheets in Microsoft Excel. The classrooms dimensions are 7.20mx 7.20m, with windows-to-wall-ratio (WWR) of 20%, 40% and 50%, and with different shading devices, such as standard horizontal overhang, sloped overhang, standard horizontal overhang with side view protection, standard horizontal overhang with a dropped edge, standard horizontal overhang with three horizontal louvers, double standard horizontal overhang, double standard horizontal overhang with three horizontal louvers, plus the use of shelf light in half the models with WWR of 40% and 50%. The data was organized in spreadsheets, with two intervals of UDI: between 300lux and 2000 lux and between 300lux and 3000lux. The simulation was performed with the weather file of 2009 to the city of NatalRN. The graphical outputs are illuminance curves, isolines of UDI among 300lux and 2000 lux and tables with index of occurrences of glare and to an UDI among 300lux 3000lux. The best UDI300-2000lux performance was evidenced to: Phase 1 (models with WWR of 20%), Phase 2 (models with WWR of 40% and 50% with light shelf). The best UDI300-3000lux performance was evidenced to: Phase 1 (models with WWR of 20% and 40% with light shelf) and Phase 2 (models with WWR of 40% and 50% with light shelf). The outputs prove that the daylight quality mainly depends on the shading system efficacy to avoid the glare occurrence, which determines the daylight discomfort. The bioclimatic recommendations of big openings with partial shading (with an opening with direct sunlight) resulted in illuminances level higher than the acceptable upper threshold. The improvement of the shading system percentage (from 73% to 91%) in medium-size of openings (WWR 40% and 50%) reduced or eliminate the glare occurrence without compromising the daylight zone depth (7.20m). The passive zone was determined for classrooms with satisfactory daylight performance, it was calculated the daylight zone depth rule-of-thumb with the ratio between daylight zone depth and the height of the window for different size of openings. The ratio ranged from 1.54 to 2.57 for WWR of 20%, 40% and 50% respectively. There was a reduction or elimination of glare in the passive area with light shelf, or with awning window shading.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main focus of this research is to design and develop a high performance linear actuator based on a four bar mechanism. The present work includes the detailed analysis (kinematics and dynamics), design, implementation and experimental validation of the newly designed actuator. High performance is characterized by the acceleration of the actuator end effector. The principle of the newly designed actuator is to network the four bar rhombus configuration (where some bars are extended to form an X shape) to attain high acceleration. Firstly, a detailed kinematic analysis of the actuator is presented and kinematic performance is evaluated through MATLAB simulations. A dynamic equation of the actuator is achieved by using the Lagrangian dynamic formulation. A SIMULINK control model of the actuator is developed using the dynamic equation. In addition, Bond Graph methodology is presented for the dynamic simulation. The Bond Graph model comprises individual component modeling of the actuator along with control. Required torque was simulated using the Bond Graph model. Results indicate that, high acceleration (around 20g) can be achieved with modest (3 N-m or less) torque input. A practical prototype of the actuator is designed using SOLIDWORKS and then produced to verify the proof of concept. The design goal was to achieve the peak acceleration of more than 10g at the middle point of the travel length, when the end effector travels the stroke length (around 1 m). The actuator is primarily designed to operate in standalone condition and later to use it in the 3RPR parallel robot. A DC motor is used to operate the actuator. A quadrature encoder is attached with the DC motor to control the end effector. The associated control scheme of the actuator is analyzed and integrated with the physical prototype. From standalone experimentation of the actuator, around 17g acceleration was achieved by the end effector (stroke length was 0.2m to 0.78m). Results indicate that the developed dynamic model results are in good agreement. Finally, a Design of Experiment (DOE) based statistical approach is also introduced to identify the parametric combination that yields the greatest performance. Data are collected by using the Bond Graph model. This approach is helpful in designing the actuator without much complexity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El artículo plantea una contribución al debate académico sobre el surgimiento del Gobierno Abierto y los requerimientos de transformación de las Administraciones Públicas para afrontar a los retos que plantea. El texto, en base a la aportación de reflexiones y evidencias, se centra en el ámbito de los profesionales del sector público y la generación de competencias digitales. El marco analítico se combina con la presentación de evidencias basadas en dos estudios de caso de innovación en gestión de recursos humanos. Los resultados obtenidos permiten ilustrar las sinergias que se dan entre el Gobierno Abierto y el desarrollo de las competencias digitales, y cómo con ello se puede orientar la mejora las capacidades institucionales de las Administraciones públicas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Face-to-face interviews are a fundamental research tool in qualitative research. Whilst this form of data collection can provide many valuable insights, it can often fall short of providing a complete picture of a research subject's experiences. Point of view (PoV) interviewing is an elicitation technique used in the social sciences as a means of enriching data obtained from research interviews. Recording research subjects' first person perspectives, for example by wearing digital video glasses, can afford deeper insights into their experiences. PoV interviewing can promote making visible the unverbalizable and does not rely as much on memory as the traditional interview. The use of such relatively inexpensive technology is gaining interest in health profession educational research and pedagogy, such as dynamic simulation-based learning and research activities. In this interview, Dr Gerry Gormley (a medical education researcher) talks to Dr Jonathan Skinner (an anthropologist with an interest in PoV interviewing), exploring some of the many crossover implications with PoV interviewing for medical education research and practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Energy auditing can be an important contribution for identification and assessment of energy conservation measures (ECMs) in buildings. Numerous tools and software have been developed, with varying degree of precision and complexity and different areas of use.   This paper evaluates PHPP as a versatile, easy-to-use energy auditing tool and gives examples of how it has been compared to a dynamic simulation tool, within the EU-project iNSPiRe. PHPP is a monthly balance energy calculation tool based on EN13790. It is intended for assisting the design of Passive Houses and energy renovation projects and as guidance in the choice of appropriate ECMs.   PHPP was compared against the transient simulation software TRNSYS for a single family house and a multi-family house. It should be mentioned that dynamic building simulations might strongly depend on the model assumptions and simplifications compared to reality, such as ideal heating or real heat emission system. Setting common boundary conditions for both PHPP and TRNSYS, the ideal heating and cooling loads and demands were compared on monthly and annual basis for seven European locations and buildings with different floor area, S/V ratio, U-values and glazed area of the external walls.   The results show that PHPP can be used to assess the heating demand of single-zone buildings and the reduction of heating demand with ECMs with good precision. The estimation of cooling demand is also acceptable if an appropriate shading factor is applied in PHPP. In general, PHPP intentionally overestimates heating and cooling loads, to be on the safe side for system sizing. Overall, the agreement with TRNSYS is better in cases with higher quality of the envelope as in cold climates and for good energy standards. As an energy auditing tool intended for pre-design it is a good, versatile and easy-to-use alternative to more complex simulation tools.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente relatório de projeto explicita as etapas da elaboração e os resultados obtidos através da realização de um projeto de reabilitação energética de um complexo de piscinas interiores. Esta reabilitação energética tem por objetivo a redução dos custos energéticos através da subtração de consumos supérfluos de energia ou da melhoria da eficiência energética dos equipamentos. Para alcançar estes objetivos recorreu-se à simulação dinâmica do edifício de modo a estimar múltiplas variáveis energéticas e identificar quais os setores e equipamentos que maior influência têm no consumo energético do complexo em estudo. Para a realização da simulação, recorreu-se a um software desenvolvido pelo DOE dos Estados Unidos da América, o Energy Plus, com o auxílio do Design Builder, que permite a criação e edição do modelo de forma mais fácil e acessível. Os valores retirados da simulação foram posteriormente comparados com valores reais. Com o complexo caraterizado e os principais consumidores identificados foi possível iniciar o estudo das medidas de melhoria da eficiência energética. As principais medidas estudadas incidiram na instalação de coberturas isotérmicas nas piscinas para reduzir a perda de energia através da evaporação e da radiação, a introdução de fontes de energia renovável como alternativa energética, substituição de elementos do sistema de iluminação e o aproveitamento de energia dissipada em equipamentos. Com este estudo, a entidade gestora do complexo encontra-se mais informada e pronta a tomar decisões que influenciem de forma significativa o consumo de energia no complexo, podendo optar pela instalação de alguma das medidas propostas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The protein Ezrin, is a member of the ERM family (Ezrin, Radixin and Moesin) that links the F-actin to the plasma membrane. The protein is made of three domains namely the FERM domain, a central α-helical domain and the CERMAD domain. The residues in Ezrin such as Ser66, Tyr145, Tyr353 and Tyr477 regulate the function of the protein through phosphorylation. The protein is found in two distinct conformations of active and dormant (inactive) state. The initial step during the conformation change is the breakage of intramolecular interaction in dormant Ezrin by phosphorylation of residue Thr567. The dormant structure of human Ezrin was predicted computationally since only partial active form structure was available. The validation analysis showed that 99.7% residues were positioned in favored, allowed and generously allowed regions of the Ramachandran plot. The Z-score of Ezrin was −7.36, G-factor was 0.1, and the QMEAN score of the model was 0.61 indicating a good model for human Ezrin. The comparison of the conformations of the activated and dormant Ezrin showed a major shift in the F2 lobe (residues 142-149 and 161-177) while changes in the conformation induced mobility shifts in lobe F3 (residues 261 to 267). The 3D positions of the phosphorylation sites Tyr145, Tyr353, Tyr477, Tyr482 and Thr567 were also located. Using targeted molecular dynamic simulation, the molecular movements during conformational change from active to dormant were visualized. The dormant Ezrin auto-inhibits itself by a head-to-tail interaction of the N-terminal and C-terminal residues. The trajectory shows the breakage of the interactions and mobility of the CERMAD domain away from the FERM domain. Protein docking and clustering analysis were used to predict the residues involved in the interaction between dormant Ezrin and mTOR. Residues Tyr477 and Tyr482 were found to be involved in interaction with mTOR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2015.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Com o aumento constante de procura de recursos naturais por parte dos vários setores da sociedade é urgente encontrar soluções para reduzir o seu consumo sem se travar a expansão demográfica que se tem vindo a sentir nos grandes centros urbanos. É através da implementação de medidas de sustentabilidade e pelo aumento da eficiência de utilização desses recursos que se tem vindo a combater esta tendência cada vez maior de consumismo global, sendo isto apenas possível com a implementação de ferramentas tecnológicas avançadas que permitem estabelecer limites ao considerado eficiente e premiando, em termos financeiros e de imagem de marketing, as entidades que o alcancem. O LEED é um sistema de certificação de sustentabilidade voluntário de edifícios residenciais e comerciais que estabelece métricas de comparação de parâmetros indicadores de consumos energéticos, hídricos e de materiais em todo o ciclo de vida do edifício e que tem vindo a ganhar destaque em crescendo a nível mundial. Esta dissertação teve como objetivo comparar a performance de consumo energético no âmbito do sistema LEED com a do sistema de certificação energética de edifícios nacional (SCE) de um grande edifício de serviços, estabelecendo um paralelismo de semelhanças e diferenças entre os dois e de avaliar os efeitos de potenciais medidas de eficiência energética e seus efeitos nas classificações de mérito obtidas em cada sistema. Os resultados obtidos na simulação que permitiu avaliar a performance foi muito satisfatório, tendo sido aproveitado pela empresa para efeitos de certificação LEED do edifício em estudo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work focuses on the creation and applications of a dynamic simulation software in order to study the hard metal structure (WC-Co). The technological ground used to increase the GPU hardware capacity was Geforce 9600 GT along with the PhysX chip created to make games more realistic. The software simulates the three-dimensional carbide structure to the shape of a cubic box where tungsten carbide (WC) are modeled as triangular prisms and truncated triangular prisms. The program was proven effective regarding checking testes, ranging from calculations of parameter measures such as the capacity to increase the number of particles simulated dynamically. It was possible to make an investigation of both the mean parameters and distributions stereological parameters used to characterize the carbide structure through cutting plans. Grounded on the cutting plans concerning the analyzed structures, we have investigated the linear intercepts, the intercepts to the area, and the perimeter section of the intercepted grains as well as the binder phase to the structure by calculating the mean value and distribution of the free path. As literature shows almost consensually that the distribution of the linear intercepts is lognormal, this suggests that the grain distribution is also lognormal. Thus, a routine was developed regarding the program which made possible a more detailed research on this issue. We have observed that it is possible, under certain values for the parameters which define the shape and size of the Prismatic grain to find out the distribution to the linear intercepts that approach the lognormal shape. Regarding a number of developed simulations, we have observed that the distribution curves of the linear and area intercepts as well as the perimeter section are consistent with studies on static computer simulation to these parameters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Accounting for around 40% of the total final energy consumption, the building stock is an important area of focus on the way to reaching the energy goals set for the European Union. The relatively small share of new buildings makes renovation of existing buildings possibly the most feasible way of improving the overall energy performance of the building stock. This of course involves improvements on the climate shell, for example by additional insulation or change of window glazing, but also installation of new heating systems, to increase the energy efficiency and to fit the new heat load after renovation. In the choice of systems for heating, ventilation and air conditioning (HVAC), it is important to consider their performance for space heating as well as for domestic hot water (DHW), especially for a renovated house where the DHW share of the total heating consumption is larger. The present study treats the retrofitting of a generic single family house, which was defined as a reference building in a European energy renovation project. Three HVAC retrofitting options were compared from a techno-economic point of view: A) Air-to-water heat pump (AWHP) and mechanical ventilation with heat recovery (MVHR), B) Exhaust air heat pump (EAHP) with low-temperature ventilation radiators, and C) Gas boiler and ventilation with MVHR. The systems were simulated for houses with two levels of heating demand and four different locations: Stockholm, Gdansk, Stuttgart and London. They were then evaluated by means of life cycle cost (LCC) and primary energy consumption. Dynamic simulations were done in TRNSYS 17. In most cases, system C with gas boiler and MVHR was found to be the cheapest retrofitting option from a life cycle perspective. The advantage over the heat pump systems was particularly clear for a house in Germany, due to the large discrepancy between national prices of natural gas and electricity. In Sweden, where the price difference is much smaller, the heat pump systems had almost as low or even lower life cycle costs than the gas boiler system. Considering the limited availability of natural gas in Sweden, systems A and B would be the better options. From a primary energy point of view system A was the best option throughout, while system B often had the highest primary energy consumption. The limited capacity of the EAHP forced it to use more auxiliary heating than the other systems did, which lowered its COP. The AWHP managed the DHW load better due to a higher capacity, but had a lower COP than the EAHP in space heating mode. Systems A and C were notably favoured by the air heat recovery, which significantly reduced the heating demand. It was also seen that the DHW share of the total heating consumption was, as expected, larger for the house with the lower space heating demand. This confirms the supposition that it is important to include DHW in the study of HVAC systems for retrofitting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Distributed energy resources will provide a significant amount of the electricity generation and will be a normal profitable business. In the new decentralized grid, customers will be among the many decentralized players and may even help to co-produce the required energy services such as demand-side management and load shedding. So, they will gain the opportunity to be more active market players. The aggregation of DG plants gives place to a new concept: the Virtual Power Producer (VPP). VPPs can reinforce the importance of these generation technologies making them valuable in electricity markets. In this paper we propose the improvement of MASCEM, a multi-agent simulation tool to study negotiations in electricity spot markets based on different market mechanisms and behavior strategies, in order to take account of decentralized players such as VPP.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Smart Grid environment allows the integration of resources of small and medium players through the use of Demand Response programs. Despite the clear advantages for the grid, the integration of consumers must be carefully done. This paper proposes a system which simulates small and medium players. The system is essential to produce tests and studies about the active participation of small and medium players in the Smart Grid environment. When comparing to similar systems, the advantages comprise the capability to deal with three types of loads – virtual, contextual and real. It can have several loads optimization modules and it can run in real time. The use of modules and the dynamic configuration of the player results in a system which can represent different players in an easy and independent way. This paper describes the system and all its capabilities.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Limestone, calcination, normal shaft kiln, process simulation, temperature profiles

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The dynamic properties of helix 12 in the ligand binding domain of nuclear receptors are a major determinant of AF-2 domain activity. We investigated the molecular and structural basis of helix 12 mobility, as well as the involvement of individual residues with regard to peroxisome proliferator-activated receptor alpha (PPARalpha) constitutive and ligand-dependent transcriptional activity. Functional assays of the activity of PPARalpha helix 12 mutants were combined with free energy molecular dynamics simulations. The agreement between the results from these approaches allows us to make robust claims concerning the mechanisms that govern helix 12 functions. Our data support a model in which PPARalpha helix 12 transiently adopts a relatively stable active conformation even in the absence of a ligand. This conformation provides the interface for the recruitment of a coactivator and results in constitutive activity. The receptor agonists stabilize this conformation and increase PPARalpha transcription activation potential. Finally, we disclose important functions of residues in PPARalpha AF-2, which determine the positioning of helix 12 in the active conformation in the absence of a ligand. Substitution of these residues suppresses PPARalpha constitutive activity, without changing PPARalpha ligand-dependent activation potential.