614 resultados para Disposable Kits


Relevância:

10.00% 10.00%

Publicador:

Resumo:

6th Graduate Student Symposium on Molecular Imprinting

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports the design of a new remotely operated underwater vehicle (ROV), which has been developed at the Underwater Systems and Technology Laboratory (USTL) - University of Porto. This design is contextualized on the KOS project (Kits for underwater operations). The main issues addressed here concern directional drag minimization, symmetry, optimized thruster positioning, stability and layout of ROV components. This design is aimed at optimizing ROV performance for a set of different operational scenarios. This is achieved through modular configurations which are optimized for each different scenario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Grau de Mestre por Licenciados Pré-Bolonha, em Biotecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Information about HIV phenotypes of resistant to available ART and the influence of different risk factors on virological failures (VF) in Costa Rican HIV positive patients prior or during HAART is unknown. MATERIALS AND METHODS: Eighty nine samples, 72 VF and 17 basal (before treatment) were analyzed by examining resistant mutants in reverse transcriptase (RT) and protease (PT) regions using Trugene or LIPA genotyping kits. Sixty eight control patients were selected and relevant information was collected in a questionnaire. RESULTS: Poor adherence, presence of resistant mutations and number of treatment's changes were the only significant factors found (p = 0.006, 0.04 and 0.01 respectively). From 66 sequenced samples, 78%, 50% and 50% showed resistance to NRTI (nucleoside reverse transcriptase inhibitors), NNRT (non-nucleoside reverse transcriptase inhibitors) and PI (protease inhibitors), respectively. The most frequent mutations were M41L, M184V, and T215FY in RT and L62PI, L10FIRV and M36I in PT. DISCUSSION: The most important factor related to treatment response in this study was adherence to treatment. Mutations in RT were related to the treatment failure while the ones found in PT were secondary mutations which have been previously described to influence the selection of primary resistance mutations in these regions. The study reveals the urgency to detect resistant mutations in VF to be considered by physicians for selection of treatment schedule, to analyze basal HIV patients for monitoring of the spread of resistant mutations and the importance to reinforce the adherence in the patients for overall treatment outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leishmanias can be produced by inoculation in conditioned McCoy cell culture growth medium (CGM). Leishmania (Leishmania) infantum chagasi (100 parasites) grown in NNN medium was inoculated in 2.5 mL CGM, kept in plates (24 wells) and its multiplication was observed for five days (120 hours). After day 5, the medium was saturated with the flagellate forms of the parasite (promastigotes). The reproduction of the leishmanias was observed every 24 hours and the number of parasites was calculated by counting the parasites in a drop of 10 µ L and photomicrographied. So the number of Leishmanias was adjusted to 1 mL volume. The advantage of the technique by isolation of Leishmania in CGM demonstrated in this study is its low cost and high efficacy even with a small quantity of parasites (10² promastigotes) used as inoculum. Additionally, isolation of the leishmania can be obtained together with an increase in their density (180 times) as observed by growth kinetics, within a shorter time. These results justify the use of this low-cost technique for the isolation and investigation of the behavior and multiplication of Leishmania both in vertebrates and invertebrates, besides offering means of obtaining antigens, whether whole antigens (leishmanias) or the soluble antigens produced by the parasites which may be useful for the production of new diagnostic kits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current diagnosis of human T-lymphotropic virus type-2 (HTLV-2) infection is based on the search of specific antibodies; nevertheless, several studies conducted in Brazil pointed deficiencies of the commercially available kits in detecting HTLV-2, mostly in HIV/AIDS patients. This study searched for the presence of HTLV-1 and -2 in 758 HIV/AIDS patients from Londrina, Paraná, Brazil. Serum samples were screened for HTLV-1/2 antibodies using two EIA kits (Vironostika and Murex), and confirmed by WB (HTLV Blot 2.4, Genelabs). The results obtained by EIA disclosed 49 (6.5%) reactive sera: 43 positive by both EIA kits, and six with discordant results. WB confirmed HTLV-1 infection in seven samples (0.9%) and HTLV-2 in 21 sera (2.8%). Negative and indeterminate results were detected in four (0.5%) and 16 (2.1%) sera, respectively. Blood from 47 out of 49 HTLV seroreactive patients were collected and analyzed for the presence of env, LTR and tax genomic segments of HTLVs by PCR. PCR confirmed six cases of HTLV-1 and 37 cases of HTLV-2 infection (14 out of 16 that were found to be WB indeterminate). Restriction analysis of the env PCR products of HTLV-2 disclosed 36 isolates of HTLV-2a/c subtype, and one of HTLV-2b subtype. These results emphasize the need of improving serologic tests for detecting truly HTLV-2 infected patients from Brazil, and confirm the presence of HTLV-2b subtype in the South of this country.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Testing problems in diagnosing human T-lymphotropic virus (HTLV) infection, mostly HTLV-II, have been documented in HIV/AIDS patients. Since December 1998, the Immunology Department of Instituto Adolfo Lutz (IAL) offers HTLV-I/II serology to Public Health Units that attend HTLV high-risk individuals. Two thousand, three hundred and twelve serum samples: 1,393 from AIDS Reference Centers (Group I), and 919 from HTLV out-patient clinics (Group II) were sent to IAL for HTLV-I/II antibodies detection. The majority of them were screened by two enzyme immunoassays (EIAs), and confirmed by Western Blot (WB 2.4, Genelabs). Seven different EIA kits were employed during the period, and according to WB results, the best performance was obtained by EIAs that contain HTLV-I and HTLV-II viral lysates and rgp21 as antigens. Neither 1st and 2nd, nor 3rd generation EIA kits were 100% sensitive in detecting truly HTLV-I/II reactive samples. HTLV-I and HTLV-II prevalence rates of 3.3% and 2.5% were detected in Group I, and of 9.6% and 3.6% in Group II, respectively. High percentages of HTLV-seroindeterminate WB sera were detected in both Groups. The algorithm testing to be employed in HTLV high-risk population from São Paulo, Brazil, needs the use of two EIA kits of different formats and compounds as screening, and because of high seroindeterminate WB, may be another confirmatory assay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Molecular characterization of Cryptosporidium spp.oocysts in clinical samples is useful for public health since it allows the study of sources of contamination as well as the transmission in different geographical regions. Although widely used in developed countries, in Brazil it is restricted to academic studies, mostly using commercial kits for the extraction of genomic DNA, or in collaboration with external reference centers, rendering the method expensive and limited. The study proposes the application of the modifications recently introduced in the method improving feasibility with lower cost. This method was efficient for clinical samples preserved at -20 °C for up to six years and the low number of oocysts may be overcomed by repetitions of extraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over a two year period, the incidence of hepatitis C virus (HCV) infection was evaluated in 29 hemodialysis patients, aged between 15 and 75 years (mean ± SD: 45 ± 39.5 years), from the University Hospital Hemodyalisis Unit, Maracaibo, Zulia State, Venezuela. Anti-HCV antibodies were determined using a fourth generation ELISA (Innotest HCV Ab IV) kit and positive blood samples were tested using a recombinant assay kit (Inno-LIA HCV Ab III), both kits from Innogenetics N.V., Belgium. The findings indicate a lack of HCV seroconversion in the hemodialysis patients over the study period, confirmed by the recombinant assay. Risk factors for HCV infection were 0.3270 (95% confidence interval: 0.01323-8.080) in patients undergoing hemodialysis. The findings suggest a lack of significant sources for HCV infection due to the preventive measures to avoid its transmission in the hemodialysis unit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The symptoms of Brazilian borreliosis resemble the clinical manifestations of Lyme disease (LD). However, there are differences between the two in terms of epidemiological and laboratory findings. Primers usually employed to diagnose LD have failed to detect Borrelia strains in Brazil. OBJECTIVE: We aimed to identify the Brazilian Borrelia using a conserved gene that synthesizes the flagellar hook (flgE) of Borrelia burgdorferi sensu lato. METHOD: Three patients presenting with erythema migrans and positive epidemiological histories were recruited for the study. Blood samples were collected, and the DNA was extracted by commercial kits. RESULTS: The gene flgE was amplified from DNA of all selected patients. Upon sequencing, these positive samples revealed 99% homology to B. burgdorferi flgE. CONCLUSION: These results support the existence of borreliosis in Brazil. However, it is unclear whether this borreliosis is caused by a genetically modified B. burgdorferi sensu stricto or by a new species of Borrelia spp.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação foi realizada em colaboração com o grupo empresarial Monteiro, Ribas e teve como principais objetivos efetuar uma avaliação das melhores técnicas disponíveis relativas à refrigeração industrial e às emissões resultantes da armazenagem. O primeiro objetivo teve como alvo todas as instalações da Monteiro, Ribas enquanto que o segundo objetivo se debruçou sobre Monteiro, Ribas, Embalagens Flexíveis, S.A.. Para cumprir estes objetivos, inicialmente efetuou-se um levantamento das melhores técnicas disponíveis apresentadas nos respetivos documentos de referência. Em seguida selecionaram-se as técnicas que se adequavam às condições e às instalações em estudo e procedeu-se a uma avaliação de forma a verificar o grau de implementação das medidas sugeridas no BREF (Best Available Techniques Reference Document). Relativamente aos sistemas de refrigeração industrial verificou-se que estão implementadas quase todas as medidas referenciadas no respetivo documento de referência. Isto prende-se com o facto dos sistemas de refrigeração existentes no complexo industrial Monteiro, Ribas serem relativamente recentes. Foram implementados no ano de 2012, e são caracterizados por apresentarem uma conceção moderna com elevada eficiência. No que diz respeito à armazenagem de produtos químicos perigosos, a instalação em estudo, apresenta algumas inconformidades, uma vez que a maioria das técnicas mencionadas no BREF não se encontram implementadas, pelo que foi necessário efetuar uma avaliação de riscos ambientais, com recurso à metodologia proposta pela Norma Espanhola UNE 150008:2008 – Análise e Avaliação do Risco Ambiental. Para isso procedeu-se então à formulação de vários cenários de riscos e à quantificação de riscos para à Monteiro, Ribas Embalagens Flexíveis S.A., tendo-se apurado que os riscos estavam avaliados como moderados a altos. Por fim foram sugeridas algumas medidas de prevenção e de minimização do risco que a instalação deve aplicar, como por exemplo, o parque de resíduos perigosos deve ser equipado com kits de contenção de derrames (material absorvente), procedimentos a realizar em caso de emergência, fichas de dados de segurança e o extintor deve ser colocado num local de fácil visualização. No transporte de resíduos perigosos, para o respetivo parque, é aconselhável utilizar bacias de contenção de derrames portáteis e kits de contenção de derrames. Relativamente ao armazém de produtos químicos perigosos é recomendado que se proceda a sua reformulação tendo em conta as MTD apresentadas no subcapítulo 5.2.3 desta dissertação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently there are several methods to extract bacterial DNA based on different principles. However, the amount and the quality of the DNA obtained by each one of those methods is highly variable and microorganism dependent, as illustrated by coagulase-negative staphylococci (CoNS) which have a thick cell wall that is difficult to lyse. This study was designed to compare the quality and the amount of CoNS DNA, extracted by four different techniques: two in-house protocols and two commercial kits. DNA amount and quality determination was performed through spectrophotometry. The extracted DNA was also analyzed using agarose gel electrophoresis and by PCR. 267 isolates of CoNS were used in this study. The column method and thermal lyses showed better results with regard to DNA quality (mean ratio of A260/280 = 1.95) and average concentration of DNA (), respectively. All four methods tested provided appropriate DNA for PCR amplification, but with different yields. DNA quality is important since it allows the application of a large number of molecular biology techniques, and also it's storage for a longer period of time. In this sense the extraction method based on an extraction column presented the best results for CoNS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated epidemiological factors for HCV infection associated with sharing perforating and cutting instruments among candidates for blood donation (CBD) in the city of Belém, Pará, Brazilian Amazon. Two definitions of HCV infection cases were used: anti-HCV positivity shown by EIA, and HCV-RNA detection by PCR. Infected and uninfected CBD completed a questionnaire about possible risk factors associated with sharing perforating and cutting instruments. The information was evaluated using simple and multiple logistic regressions. Between May and November 2010, 146 (1.1%) persons with anti-HCV antibodies and 106 (0.8%) with HCV-RNA were detected among 13,772 CBD in Belém. Risk factors associated with HCV infection based on the EIA (model 1) and PCR (model 2) results were: use of needles and syringes sterilized at home; shared use of razors at home, sharing of disposable razors in barbershops, beauty salons etc.; and sharing manicure and pedicure material. The models of HCV infection associated with sharing perforating and cutting instruments should be taken into account by local and regional health authorities and by those of other countries with similar cultural practices, in order to provide useful information to guide political and public strategies to control HCV transmission.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SUMMARY The role of trace elements in dengue virulence is not yet known. The present study assessed the serum levels of two micronutrients, copper and iron, in cases of dengue fever. The study involved 96 patients of whom 48 had either severe or non-severe forms of dengue (with and without warning signs), and the remaining 48 were patients with other febrile illnesses (OFI), used as controls. Serum levels of copper and iron were evaluated at admission and by the time of defervescence using commercially available kits. At admission, no difference in the level of serum copper was observed between cases and controls. In the group of dengue cases, the copper level was found to be significantly decreased in severe and non-severe cases with warning signs, compared to non-severe cases without warning signs. In contrast, by the time of defervescence the copper level was found to be increased in all dengue cases compared to OFI controls, but no difference was observed among dengue cases. Unlike OFI controls, dengue cases showed an increasing pattern of copper levels from admission until defervescence. On the other hand, no such significant differences were observed in the serum level of iron in the clinical groups, except for a decreased iron level found in severe cases, compared to non-severe dengue without warning signs. The results show that copper is associated with dengue severity and this finding emphasizes the need to investigate the involvement of trace elements in disease severity so as to improve the prognosis of dengue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina