929 resultados para Discharge coefficients
Resumo:
Microwave treated water soluble and amide functionalized single walled carbon nanotubes have been investigated using femtosecond degenerate pump-probe and nonlinear transmission experiments. The time resolved differential transmission using 75 femtosecond pulse with the central wavelength of 790 nm shows a bi-exponential ultrafast photo-bleaching with time constants of 160 fs (130 fs) and 920 fs (300 fs) for water soluble (amide functionalized) nanotubes. Open and closed aperture z-scans show saturation absorption and positive (negative) nonlinear refraction for water soluble (amide functionalized) nanotubes. Two photon absorption coefficient, beta(0) similar to 250 cm/GW (650 cm/GW) and nonlinear index, gamma similar to 15 cm(2)/pW (-30 cm(2)/pW) are obtained from the theoretical fit in the saturation limit to the data for two types of nanotubes.
Resumo:
Purity of the glow-discharge plasma at atmospheric pressure for surface modification applications is always debatable, since it works at ambient atmosphere. We have demonstrated on the use of optical emission spectroscopy to test the purity of this kind of plasma. The effect of gas flow pattern, nature of gas, and its flow rate on the plasma chemistry was studied. The importance of proper system design in maintaining a uniform flow of heavy and inert gases as carrier gas in atmospheric glow-discharge plasma was confirmed. The surface of a plasma-treated PET sample was analyzed using X-ray photoelectron spectroscopy to verify the studies on plasma purity done using emission spectrum.
Resumo:
Experimental results on the effect of energy deposition using an electric arc discharge, upstream of a 60° half angle blunt cone configuration in a hypersonic flow is reported.Investigations involving drag measurements and high speed schlieren flow visualization have been carried out in hypersonic shock tunnel using air and argon as the test gases; and an unsteady drag reduction of about 50% (maximum reduction) has been observed in the energy deposition experiments done in argon environment. These studies also show that the effect of discharge on the flow field is more pronounced in argon environment as compared to air, which confirms that thermal effects are mainly responsible for flow alteration in presence of the discharge.
Resumo:
Precise measurements of the ultrasonic velocities and thermal expansivities of amorphous Se80Te20 and Se90Te10 alloys are reported near the glass transition. The samples are produced by liquid quenching. The longitudinal and transverse velocities are measured at 10 MHz frequency using the McSkimin pulse superposition technique. The thermal expansivities,agr, are measured using a three-terminal capacitance bridge. Theagr-values show a sharp maximum near the glass transition temperature,T g. The ultrasonic velocities also show a large temperature derivative, dV/dT nearT g. The data are discussed in terms of existing theories of the glass transition. The continuous change inagr shows that the glass transition is not a first-order transition, as suggested by some theories. The samples are found to be deformed by small loads nearT g. The ultrasonic velocities and dV/dT have contributions arising from this deformation.
Resumo:
Digital image
Resumo:
An investigation of power frequency (50 Hz) surface partial discharges in dry air, using 21r/3 Rogowski profile electrodes in the low pressure range of 0.067 to 91.333 kPa, shows that for the discharges occurring symmetrically around the electrodes and just outside the uniform field region, the breakdown voltages are 20 to 30% lower than those accounted for by the usual Paschen values. Emphasis, therefore, has been given to modified values of breakdown voltages for any useful calculations. The effect of reduced pressure on inception voltage has been discussed and an attempt has been made to explain the difference between the observed and calculated values on the basis of a pressure-dependent secondary ionization coefficient. It is shown that increasing the insulation thickness in a critical pressure range (0.067 to 0.400 kPa) does not allow any significant increase in the discharge free working stress of the insulation system. At higher pressures (>0.400 kPa) the increase in inception voltage with thickness and pressure follows an equation which is expected to hold for other insulating materials as well.
Resumo:
Invariant magneto-electric coefficients and invariant piezomagnetic coefficients are obtained for all the magnetic crystal classes.
Resumo:
Townsend's first ionization coefficients have been measured in corssed electric and magnetic fields for values of B/p ranging from 0.013 TESLA. TORR-1 to 0.064 TESLA.TORR-1 and for 103 x 102¿ E/p 331 x 102 V.M-1. TORR-1 in oxygen and for 122 x 102¿ E/pÂ488 x 102 V.M-1.TORR-1 for dry air. The values of effective collision frequencies determined from the equivalent pressure (pe) concept generally increase with E/p at constant B/p and decrease with increasing B/p at constant E/p. Effective collision frequencies determined from measured sparking potentials at high values of E/p increase with decreasing E/pe. The drift velocity and mean energy of electrons in oxygen in crossed electric and magnetic fields have been derived.
Resumo:
This research investigated the efficacy of a post-discharge nurse-led clinic, for patients who underwent a cardiovascular interventional procedure in Australia. A randomised controlled clinical trial measured the effects of the clinic on patient confidence to self-manage and minimise psychological distress given the strong link between anxiety, depression and coronary heart disease. Hospitalisation for the procedure is short and stressful, and patients may wait up to 7-64 days for post-discharge review. This study provides preliminary quantitative and qualitative evidence that nurse-led clinics undertaken within the first week post-percutaneous coronary intervention may fill a much-needed gap for patients during a potentially vulnerable period.
Resumo:
A quasi-geometric stability criterion for feedback systems with a linear time invariant forward block and a periodically time varying nonlinear gain in the feedback loop is developed.
Resumo:
Using the concept of energy-dependent effective field intensity, electron transport coefficients in nitrogen have been determined in E times B fields (E = electric field intensity, B = magnetic flux density) by the numerical solution of the Boltzmann transport equation for the energy distribution of electrons. It has been observed that as the value of B/p (p = gas pressure) is increased from zero, the perpendicular drift velocity increased linearly at first, reaches a maximum value, and then decreases with increasing B/p. In general, the electron mean energy is found to be a function of Eavet/p( Eavet = averaged effective electric field intensity) only, but the other transport coefficients, such as transverse drift velocity, perpendicular drift velocity, and the Townsend ionization coefficient, are functions of both E/p and B/p.
Resumo:
Corepresentations of a coalgebra over a quadratic operad are defined, and various characterizations of them are given. Cohomology of such an operadic coalgebra with coefficients in a corepresentation is then studied.
Resumo:
The main obstacle for the application of high quality diamond-like carbon (DLC) coatings has been the lack of adhesion to the substrate as the coating thickness is increased. The aim of this study was to improve the filtered pulsed arc discharge (FPAD) method. With this method it is possible to achieve high DLC coating thicknesses necessary for practical applications. The energy of the carbon ions was measured with an optoelectronic time-of-flight method. An in situ cathode polishing system used for stabilizing the process yield and the carbon ion energies is presented. Simultaneously the quality of the coatings can be controlled. To optimise the quality of the deposition process a simple, fast and inexpensive method using silicon wafers as test substrates was developed. This method was used for evaluating the suitability of a simplified arc-discharge set-up for the deposition of the adhesion layer of DLC coatings. A whole new group of materials discovered by our research group, the diamond-like carbon polymer hybrid (DLC-p-h) coatings, is also presented. The parent polymers used in these novel coatings were polydimethylsiloxane (PDMS) and polytetrafluoroethylene (PTFE). The energy of the plasma ions was found to increase when the anode-cathode distance and the arc voltage were increased. A constant deposition rate for continuous coating runs was obtained with an in situ cathode polishing system. The novel DLC-p-h coatings were found to be water and oil repellent and harder than any polymers. The lowest sliding angle ever measured from a solid surface, 0.15 ± 0.03°, was measured on a DLC-PDMS-h coating. In the FPAD system carbon ions can be accelerated to high energies (≈ 1 keV) necessary for the optimal adhesion (the substrate is broken in the adhesion and quality test) of ultra thick (up to 200 µm) DLC coatings by increasing the anode-cathode distance and using high voltages (up to 4 kV). An excellent adhesion can also be obtained with the simplified arc-discharge device. To maintain high process yield (5µm/h over a surface area of 150 cm2) and to stabilize the carbon ion energies and the high quality (sp3 fraction up to 85%) of the resulting coating, an in situ cathode polishing system must be used. DLC-PDMS-h coating is the superior candidate coating material for anti-soiling applications where also hardness is required.
Resumo:
Published research on discharge planning is written from the perspective of hospital wards and community services. Limited research focuses on discharge planning in the emergency department (ED). The objective of this study was to identify ED nurses’ perceptions of factors influencing the implementation of discharge planning. This qualitative study collected data from 25 ED nurses through in-depth interviews and a drawing task in which participants were asked to depict on paper the implementation of discharge planning in their practice. Factors influencing discharge planning were grouped into three categories: discharge planning as a neglected issue in the ED, heavy workload, and the negative attitudes of ED patients and their families. The study highlighted a need for effective discharge planning to be counted as an essential clinical competency for ED nurses and factored into their everyday workload. Nurses perceived that organizational culture, and parents’ and relatives’ attitudes were barriers to implementing discharge teaching in the ED.