962 resultados para Direct digital detector images


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to compare the efficacy of a direct clinical evaluation method with an indirect digital photographic method in assessing the quality of dental restorations. Seven parameters (color, occlusal marginal adaptation, anatomy form, roughness, occlusal marginal stain, luster, and secondary caries) were assessed in 89 Class I and Class II restorations from 36 adults using the modified US Public Health Service/Ryge criteria. Standardized photographs of the same restorations were digitally processed by Adobe Photoshop software, separated into the following four groups and assessed by two calibrated examiners: Group A: The original photograph displayed at 100%, without modifications (IMG100); Group B: Formed by images enlarged at 150% (IMG150); Group C: Formed by digital photographs displayed at 100% (mIMG100), with digital modifications (levels adjustment, shadow and highlight correction, color balance, unsharp Mask); and Group D: Formed by enlarged photographs displayed at 150% with modifications (mIMG150), with the same adjustments made to Group C. Photographs were assessed on a calibrated screen (Macbook) by two calibrated clinicians, and the results were statistically analyzed using Wilcoxon tests (SSPS 11.5) at 95% CI. Results: The photographic method produced higher reliability levels than the direct clinical method in all parameters. The evaluation of digital images is more consistent with clinical assessment when restorations present some moderate defect (Bravo) and less consistent when restorations are clinically classified as either satisfactory (Alpha) or in cases of severe defects (Charlie). Conclusion: The digital photographic method is a useful tool for assessing the quality of dental restorations, providing information that goes unnoticed with the visual-tactile clinical examination method. Additionally, when analyzing restorations using the Ryge modified criteria, the digital photographic method reveals a significant increase of defects compared to those clinically observed with the naked eye. Photography by itself, without the need for enlargement or correction, provides more information than clinical examination and can lead to unnecessary overtreatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ziel des NA48 Experiments ist die Messung der direkten CPVerletzungim System der neutralen Kaonen. NA48 misst gleichzeitig dieZerfaellekurzlebiger und langlebiger Kaonen in zwei geladene undneutralePionen. Der Parameter der direkten CP Verletzung wird durchdasDoppelverhaeltnis der vier Zerfallsraten bestimmt. DasExperiment unddie Analyse sind so gestaltet, dass sich systematischeEffekte imDoppelverhaeltnis der Zerfallsraten prinzipiell aufheben.DieBestimmung unvermeidlicher systematischer Abweichungen nimmteinenHauptteil der Dissertation ein. Fuer diese Analyse wurdendie Datender ersten Strahlzeit 1997 verwendet. Das Ergebnis dieserAnalysefuer den Parameter der direkten CP Verletzung ist (18.3 +/-4.6 +/- 5.8) * 10E-4.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lo scopo di questo lavoro è la caratterizzazione fisica del flat panel PaxScan4030CB Varian, rivelatore di raggi X impiegato in un ampio spettro di applicazioni cliniche, dalla radiografia generale alla radiologia interventistica. Nell’ambito clinico, al fine di una diagnosi accurata, è necessario avere una buona qualità dell’immagine radiologica mantenendo il più basso livello di dose rilasciata al paziente. Elemento fondamentale per ottenere questo risultato è la scelta del rivelatore di radiazione X, che deve garantire prestazioni fisiche (contrasto, risoluzione spaziale e rumore) adeguati alla specifica procedura. Le metriche oggettive che misurano queste caratteristiche sono SNR (Signal-to-Noise Ratio), MTF (Modulation Transfer Function) ed NPS (Noise Power Spectrum), che insieme contribuiscono alla misura della DQE (Detective Quantum Efficiency), il parametro più completo e adatto a stabilire le performance di un sistema di imaging. L’oggettività di queste misure consente anche di mettere a confronto tra loro diversi sistemi di rivelazione. La misura di questi parametri deve essere effettuata seguendo precisi protocolli di fisica medica, che sono stati applicati al rivelatore PaxScan4030CB presente nel laboratorio del Centro di Coordinamento di Fisica Medica, Policlinico S.Orsola. I risultati ottenuti, conformi a quelli dichiarati dal costruttore, sono stati confrontati con successo con alcuni lavori presenti in letteratura e costituiscono la base necessaria per la verifica di procedure di ottimizzazione dell’immagine radiologica attraverso interventi sul processo di emissione dei raggi X e sul trattamento informatico dell’immagine (Digital Subtraction Angiography).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work we study a model for the breast image reconstruction in Digital Tomosynthesis, that is a non-invasive and non-destructive method for the three-dimensional visualization of the inner structures of an object, in which the data acquisition includes measuring a limited number of low-dose two-dimensional projections of an object by moving a detector and an X-ray tube around the object within a limited angular range. The problem of reconstructing 3D images from the projections provided in the Digital Tomosynthesis is an ill-posed inverse problem, that leads to a minimization problem with an object function that contains a data fitting term and a regularization term. The contribution of this thesis is to use the techniques of the compressed sensing, in particular replacing the standard least squares problem of data fitting with the problem of minimizing the 1-norm of the residuals, and using as regularization term the Total Variation (TV). We tested two different algorithms: a new alternating minimization algorithm (ADM), and a version of the more standard scaled projected gradient algorithm (SGP) that involves the 1-norm. We perform some experiments and analyse the performance of the two methods comparing relative errors, iterations number, times and the qualities of the reconstructed images. In conclusion we noticed that the use of the 1-norm and the Total Variation are valid tools in the formulation of the minimization problem for the image reconstruction resulting from Digital Tomosynthesis and the new algorithm ADM has reached a relative error comparable to a version of the classic algorithm SGP and proved best in speed and in the early appearance of the structures representing the masses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

STEPanizer is an easy-to-use computer-based software tool for the stereological assessment of digitally captured images from all kinds of microscopical (LM, TEM, LSM) and macroscopical (radiology, tomography) imaging modalities. The program design focuses on providing the user a defined workflow adapted to most basic stereological tasks. The software is compact, that is user friendly without being bulky. STEPanizer comprises the creation of test systems, the appropriate display of digital images with superimposed test systems, a scaling facility, a counting module and an export function for the transfer of results to spreadsheet programs. Here we describe the major workflow of the tool illustrating the application on two examples from transmission electron microscopy and light microscopy, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p = 0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This project proposes a module for teaching visual composition within the context of a written composition course. Drawing from process writing theory, critical pedagogy, and photo-elicitation, “Composing In Words And Images” gives composition teachers a module and direct instruction for the incorporation of critical visual composition studies in their writing classes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A search for direct chargino production in anomaly-mediated supersymmetry breaking scenarios is performed in p p collisions at root s = 7 TeV using 4.7 fb(-1) of data collected with the ATLAS experiment at the LHC. In these models, the lightest chargino is predicted to have a lifetime long enough to be detected in the tracking detectors of collider experiments. This analysis explores such models by searching for chargino decays that result in tracks with few associated hits in the outer region of the tracking system. The transverse-momentum spectrum of candidate tracks is found to be consistent with the expectation from the Standard Model background processes and constraints on chargino properties are obtained.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A search for the electroweak pair production of charged sleptons and weak gauginos decaying into final states with two leptons is performed using 4.7 fb(-1) of proton-proton collision data at root s = 7 TeV recorded with the ATLAS experiment at the Large Hadron Collider. No significant excesses are observed with respect to the prediction from Standard Model processes. In the scenario of direct slepton production, if the sleptons decay directly into the lightest neutralino, left-handed slepton masses between 85 and 195 GeV are excluded at 95% confidence level for a 20 GeV neutralino. Chargino masses between 110 and 340 GeV are excluded in the scenario of direct production of wino-like chargino pairs decaying into the lightest neutralino via an intermediate on-shell charged slepton for a 10 GeV neutralino. The results are also interpreted in the framework of the phenomenological minimal supersymmetric Standard Model.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The results of a search for pair production of supersymmetric partners of the Standard Model third-generation quarks are reported. This search uses 20.1 fb(-1) of pp collisions at root s = 8 TeV collected by the ATLAS experiment at the Large Hadron Collider. The lightest bottom and top squarks ((b) over tilde (1) and (t) over tilde (1) respectively) are searched for in a final state with large missing transverse momentum and two jets identified as originating from b-quarks. No excess of events above the expected level of Standard Model background is found. The results are used to set upper limits on the visible cross section for processes beyond the Standard Model. Exclusion limits at the 95% confidence level on the masses of the third-generation squarks are derived in phenomenological supersymmetric R-parity-conserving models in which either the bottom or the top squark is the lightest squark. The (b) over tilde (1) is assumed to decay via (b) over tilde (1) -> b (chi) over tilde (0)(1) and the (t) over tilde (1) via (t) over tilde (1) b (chi) over tilde (+/-)(1), with undetectable products of the subsequent decay of the (chi) over tilde (+/-)(1) due to the small mass splitting between the (chi) over tilde (+/-)(1) and the (chi) over tilde (0)(1)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The results of a search for direct pair production of the scalar partner to the top quark using an integrated luminosity of 20.1fb−1 of proton-proton collision data at s√=8 TeV recorded with the ATLAS detector at the LHC are reported. The top squark is assumed to decay via t~→tχ~01 or t~→bχ~±1→bW(∗)χ~01, where χ~01 (χ~±1) denotes the lightest neutralino (chargino) in supersymmetric models. The search targets a fully-hadronic final state in events with four or more jets and large missing transverse momentum. No significant excess over the Standard Model background prediction is observed, and exclusion limits are reported in terms of the top squark and neutralino masses and as a function of the branching fraction of t~→tχ~01. For a branching fraction of 100%, top squark masses in the range 270-645 GeV are excluded for χ~01 masses below 30 GeV. For a branching fraction of 50% to either t~→tχ~01 or t~→bχ~±1, and assuming the χ~±1 mass to be twice the χ~01 mass, top squark masses in the range 250-550 GeV are excluded for χ~01 masses below 60 GeV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Searches for the electroweak production of charginos, neutralinos and sleptons in final states characterized by the presence of two leptons (electrons and muons) and missing transverse momentum are performed using 20.3 fb−1 of proton-proton collision data at ps = 8TeV recorded with the ATLAS experiment at the Large Hadron Collider. No significant excess beyond Standard Model expectations is observed. Limits are set on the masses of the lightest chargino, next-to-lightest neutralino and sleptons for different lightest-neutralino mass hypotheses in simplified models. Results are also interpreted in various scenarios of the phenomenological Minimal Supersymmetric Standard Model.