916 resultados para Digital processing image


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Topex/Poseidon sea surface height anomalies during 1993-2002 are decomposed using 2-D finite impulse response filters which showed biannual Rossby waves (BRWs) in the equatorial Indian Ocean (peak at 1.5 degrees S) and in the southern tropical Indian Ocean (peak at 10.5 degrees S) during Indian Ocean Dipole (IOD) years. Anomalous downwelling BRWs in the equatorial Indian Ocean triggered by the wind stress curl-induced Ekman pumping near the eastern boundary started propagating westward from the eastern boundary in July/August 1993 and 1996, i.e., more than one year prior to the formation of the IOD events of 1994 and 1997 respectively. These strong downwelling signals reach the western equatorial Indian Ocean during the peak dipole time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ultrasonography has an inherent noise pattern, called speckle, which is known to hamper object recognition for both humans and computers. Speckle noise is produced by the mutual interference of a set of scattered wavefronts. Depending on the phase of the wavefronts, the interference may be constructive or destructive, which results in brighter or darker pixels, respectively. We propose a filter that minimizes noise fluctuation while simultaneously preserving local gray level information. It is based on steps to attenuate the destructive and constructive interference present in ultrasound images. This filter, called interference-based speckle filter followed by anisotropic diffusion (ISFAD), was developed to remove speckle texture from B-mode ultrasound images, while preserving the edges and the gray level of the region. The ISFAD performance was compared with 10 other filters. The evaluation was based on their application to images simulated by Field II (developed by Jensen et al.) and the proposed filter presented the greatest structural similarity, 0.95. Functional improvement of the segmentation task was also measured, comparing rates of true positive, false positive and accuracy. Using three different segmentation techniques, ISFAD also presented the best accuracy rate (greater than 90% for structures with well-defined borders). (E-mail: fernando.okara@gmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In industrial countries, cardiovascular diseases remain the primary cause of death. This review summarizes the role of percutaneous coronary interventions (PCI) in the treatment of coronary heart disease. Interventional therapy of coronary artery disease was initiated in 1977 with the introduction of balloon angioplasty by Andreas Grüntzig in Zurich. Technical progress since has been related to construction and materials of catheters, but also to digital processing of x-ray imaging. Additional methods - rotablation, atherectomy, laser, intravascular ultrasound, and most importantly stent implantation were developed. Only stents significantly changed the procedure. They are today an integral part of PCI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ZooScan with ZooProcess and Plankton Identifier (PkID) software is an integrated analysis system for acquisition and classification of digital zooplankton images from preserved zooplankton samples. Zooplankton samples are digitized by the ZooScan and processed by ZooProcess and PkID in order to detect, enumerate, measure and classify the digitized objects. Here we present a semi-automatic approach that entails automated classification of images followed by manual validation, which allows rapid and accurate classification of zooplankton and abiotic objects. We demonstrate this approach with a biweekly zooplankton time series from the Bay of Villefranche-sur-mer, France. The classification approach proposed here provides a practical compromise between a fully automatic method with varying degrees of bias and a manual but accurate classification of zooplankton. We also evaluate the appropriate number of images to include in digital learning sets and compare the accuracy of six classification algorithms. We evaluate the accuracy of the ZooScan for automated measurements of body size and present relationships between machine measures of size and C and N content of selected zooplankton taxa. We demonstrate that the ZooScan system can produce useful measures of zooplankton abundance, biomass and size spectra, for a variety of ecological studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Se ha desarrollado un sistema electrónico computerizado, portátil y de bajo consumo, denominado Medidor de Velocidad de Vehículos por Ultrasonidos de Alta Exactitud, VUAE. La alta exactitud de la medida conseguida en el VUAE hace que pueda servir de medida de referencia de la velocidad de un vehículo circulando en carretera. Por tanto el VUAE puede usarse como medida de referencia que permita estimar el error de los cinemómetros comerciales. El VUAE está compuesto por n (n≥2) parejas de emisores y receptores piezoeléctricos de ultrasonidos, denominados E-Rult. Los emisores de las n parejas E-Rult generan n barreras de ultrasonidos, y los receptores piezoeléctricos captan la señal de los ecos cuando el vehículo atraviesa las barreras. Estos ecos se procesan digitalmente para conseguir señales representativas. Posteriormente, utilizando la técnica de la correlación cruzada de señales, se ha podido estimar con alta exactitud la diferencia de tiempos entre los ecos captados en cada barrera. Con los tiempos entre ecos y con la distancia entre cada una de las n barreras de ultrasonidos se puede realizar una estimación de la velocidad del vehículo con alta exactitud. El VUAE se ha contrastado con un sistema de velocidad de referencia, basado en cables piezoeléctricos. ABSTRACT We have developed a portable computerized and low consumption, our system is called High Accuracy Piezoelectric Kinemometer measurement, herein VUAE. By the high accuracy obtained by VUAE it make able to use the VUAE to obtain references measurements of system for measuring Speeds in Vehicles. Therefore VUAE could be used how reference equipment to estimate the error of installed kinemometers. The VUAE was created with n (n≥2) pairs of ultrasonic transmitter-receiver, herein E-Rult. The transmitters used in the n couples E-Rult generate n ultrasonic barriers and receivers receive the echoes when the vehicle crosses the barriers. Digital processing of the echoes signals let us to obtain acceptable signals. Later, by mean of cross correlation technics is possible make a highly exact estimation of speed of the vehicle. The log of the moments of interception and the distance between each of the n ultrasounds allows for a highly exact estimation of speed of the vehicle. VUAE speed measurements were compared to a speed reference system based on piezoelectric cables.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este proyecto fin de carrera tiene como finalidad el diseño e implementación de un sistema multicanal de medida de temperaturas con termopares con procesado digital. Se ha realizado un prototipo de cuatro canales con conexión de termopar, que es el tipo de sensor utilizado para realizar dichas medidas. La tensión generada por el termopar es procesada mediante un conversor de termopar a digital con salida en interfaz modo serie o SPI (Serial Peripheral Interface). El control de dicha comunicación se realiza por medio de un Array de Puertas Lógicas Programables o FPGA (Field Programmable Gate Array), en concreto se ha utilizado una plataforma de desarrollo modelo Virtex-5 de la empresa Xilinx. Esta tarjeta se ha programado también para el procesado software y la posterior comunicación serie con el PC, el cual consta de una interfaz de usuario donde se muestran los resultados de las medidas en tiempo real. El proyecto ha sido desarrollado en colaboración con una empresa privada dedicada principalmente al diseño electrónico. La finalidad de este prototipo es el estudio de una actualización del bloque de medida para el control de las curvas de temperatura de un equipo de reparación aeronáutica. En esta memoria se describe el proceso realizado para el desarrollo del prototipo, incluye la presentación de los estudios realizados y la información necesaria para llevar a cabo el diseño, la fabricación y la programación de los diferentes bloques que componen el sistema. ABSTRACT. The aim of this project is to implement a multichannel temperature measurement system with digital processing, using thermocouples. A four-channel prototype with thermocouple connection has been built. The thermocouple voltage is converted to digital line using a Thermocouple-to-Digital Converter with a Serial Perpheral Interface (SPI) output. The master which controls this communication is embedded in a Field Programmable Gate Array (FPGA), specifically the Xilinx Virtex-5 model. This FPGA also has the code for software temperature processing and the prototype to PC serial communication embedded. The PC user interface displays the measurement results in real time. This project has been developed at a private electronics design company. The company wants to study an update to change the analogue temperature controller equipment to a digital one. So this prototype studies a digital version of the temperature measurement block. The processes accomplished for the prototype development are detailed in the next pages of this document. It includes the studies and information needed to develop the design, manufacturing process and programming of the blocks which integrate with the global system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este proyecto se basa en la integración de funciones optimizadas de OpenHEVC en el códec Reconfigurable Video Coding (RVC) - High Efficiency Video Coding (HEVC). RVC es un framework capaz de generar automáticamente el código que implementa cualquier estándar de video mediante el uso de librerías. Estas librerías contienen la definición de bloques funcionales de los que se componen los distintos estándares de video a implementar. Sin embargo, como desventaja a la facilidad de creación de estándares utilizando este framework, las librerías que utiliza no se encuentran optimizadas. Por ello se pretende que el códec RVC-HEVC sea capaz de realizar llamadas a funciones optimizadas, que para el estudio éstas se encontrarán en la librería OpenHEVC. Por otro lado, estos codificadores de video se pueden encontrar implementados tanto en PCs como en sistemas embebidos. Los Digital Signal Processors (DSPs) son unas plataformas especializadas en el procesamiento digital, teniendo una alta velocidad en el cómputo de operaciones matemáticas. Por ello, para este proyecto se integrará RVC-HEVC con las llamadas a OpenHEVC en una plataforma DSP como la TMS320C6678. Una vez completa la integración se efectuan medidas de eficiencia para ver cómo las llamadas a funciones optimizadas mejoran la velocidad en la decodificación de imágenes. ABSTRACT. This project is based in the integration of optimized functions from OpenHEVC in the RVC-HEVC (Reconfigurable Video Coding- High Efficiency Video Coding) codec. RVC is a framework capable of generating automatically any type of video standard with the use of libraries. Inside these libraries there are the definitions of the functional blocks which make up the different standards, in which for the case of study will be the HEVC standard. Nevertheless, as a downside for the simplicity in producing standards with the RVC tool, these libraries are not optimized. Thus, one of the goals for the project will be to make the RVC-HEVC call optimized functions, in which in this case they will be inside the OpenHEVC library. On the other hand, these video encoders can be implemented both in PCs and embedded systems. The DSPs (Digital Signal Processors) are platforms specialized in digital processing, being able to compute mathematical operations in a short period of time. Consequently, for this project the integration of the RVC-HEVC with calls to the OpenHEVC library will be done in a DSP platform such as a TMS320C6678. Once completed the integration, performance measures will be carried out to evaluate the improvement in the decoding speed obtained when optimized functions are used by the RVC-HEVC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este proyecto versa sobre un modelo de evaluación de calidad de imagen aplicado a la optimización del ancho de banda del multiplex de televisión, mediante la realización de ensayos con distintas configuraciones de cabecera. Dicho modelo se basa en las medidas PQR y DMOS de Tektronix, destinadas a medir la percepción de las diferencias entre una secuencia antes y después de sufrir un procesado digital. Dado que actualmente, el modo de trabajo de una cabecera de televisión digital, es la multiplexación estadística (consistente en la codificación de diferentes servicios de vídeo con anchos de banda variables en función de la complejidad de las señales), las medidas estarán enfocadas a sacar conclusiones acerca de la cantidad de canales, complejidad de contenidos, y organización de los mismos en el ancho de banda disponible para emitir, manteniendo niveles de calidad Broadcast. Las medidas serán aplicadas en el proyecto para comparar el rendimiento de dos modelos de cabecera. En primer lugar serán configuradas en régimen binario constante, comparando el rendimiento de los codificadores en el área de trabajo habitual. Posteriormente se configuraran en régimen binario variable probando múltiples configuraciones, con el objetivo dar con el modelo y configuración óptima para su posterior implementación. ABSTRACT. This project concerns a picture quality assessment model applied to television multiplex bandwidth optimization by conducting test with different headend settings. This model is based on the PQR and DMOS Tektronix measures, designed to measure the differences between a sequence before and after a digital processing. Given that nowadays the working way of television headend is by statistical multiplexing (based on coding the different video services with variable bitrate depending on the complexity of the signals) measures will be focused to reach conclusions about the number of channels, complexity of content, and the way to organize them through the available bandwidth, keeping broadcast quality ratios. The measures will be applied comparing the performance of two headend models. First of all encoders will be set on constant bitrate, comparing the performance through the working bandwidth. Later on, both models will be set on variable bitrate testing multiple configurations, in order to find the optimal model/configuration for later implementation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El trabajo fin de master “Análisis de la precisión en la medida del tiempo de reverberación y de los parámetros asociados” tiene como objetivo primordial la evaluación de los parámetros y métodos utilizados para la obtención de estos, a través del tiempo de reverberación, tanto de forma global, conjunto de todos los métodos, como cada uno de ellos por separado. Un objetivo secundario es la evaluación de la incertidumbre en función del método de medición usado. Para realizarlo, se van a aprovechar las mediciones realizadas para llevar a cabo el proyecto fin de carrera [1], donde se medía el tiempo de reverberación en dos recintos diferentes usando el método del ruido interrumpido y el método de la respuesta impulsiva integrada con señales distintas. Las señales que han sido utilizadas han sido señales impulsivas de explosión de globos, disparo de pistola, claquetas y, a través de procesado digital, señales periódicas pseudoaleatorias MLS y barridos de tonos puros. La evaluación que se realizará a cada parámetro ha sido extraída de la norma UNE 89002 [2], [3]y [4]. Se determinará si existen valores aberrantes tanto por el método de Grubbs como el de Cochran, e interesará conocer la veracidad, precisión, repetibilidad y reproducibilidad de los resultados obtenidos. Los parámetros que han sido estudiados y evaluados son el tiempo de reverberación con caída de 10 dB, (T10), con caída de 15 dB (T15), con caída de 20 dB (T20), con caída de 30 dB (T30), el tiempo de la caída temprana (EDT), el tiempo final (Ts), claridad (C20, C30, C50 y C80) y definición (D50 y D80). Dependiendo de si el parámetro hace referencia al recinto o si varía en función de la relación entre la posición de fuente y micrófono, su estudio estará sujeto a un procedimiento diferente de evaluación. ABSTRACT. The master thesis called “Analysis of the accuracy in measuring the reverberation time and the associated parameters” has as the main aim the assessment of parameters and methods used to obtain these through reverberation time, both working overall, set of all methods, as each of them separately. A secondary objective is to evaluate the uncertainty depending on the measurement method used. To do this, measurements of [1] will be used, where they were carried on in two different spaces using the interrupted noise method and the method of impulse response integrated with several signals. The signals that have been used are impulsive signals such as balloon burst, gunshot, slates and, through digital processing, periodic pseudorandom signal MLS and swept pure tone. The assessment that will be made to each parameter has been extracted from the UNE 89002 [2], [3] and [4]. It will determine whether there are aberrant values both through Grubbs method and Cochran method, to say so, if a value is inconsistent with the rest of the set. In addition, it is interesting to know the truthfulness, accuracy, repeatability and reproducibility of results obtained from the first part of this rule. The parameters that are going to be evaluated are reverberation time with 10 dB decay, (T10), with 15 dB decay (T15), with 20 dB decay (T20), with 30 dB decay (T30), the Early Decay Time (EDT), the final time (Ts), clarity (C20, C30, C50 y C80) and definition (D50 y D80). Depending on whether the parameter refers to the space or if it varies depending on the relationship between source and microphone positions, the study will be related to a different evaluation procedure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The usage of HTTP adaptive streaming (HAS) has become widely spread in multimedia services. Because it allows the service providers to improve the network resource utilization and user׳s Quality of Experience (QoE). Using this technology, the video playback interruption is reduced since the network and server status in addition to capability of user device, all are taken into account by HAS client to adapt the quality to the current condition. Adaptation can be done using different strategies. In order to provide optimal QoE, the perceptual impact of adaptation strategies from point of view of the user should be studied. However, the time-varying video quality due to the adaptation which usually takes place in a long interval introduces a new type of impairment making the subjective evaluation of adaptive streaming system challenging. The contribution of this paper is two-fold: first, it investigates the testing methodology to evaluate HAS QoE by comparing the subjective experimental outcomes obtained from ACR standardized method and a semi-continuous method developed to evaluate the long sequences. In addition, influence of using audiovisual stimuli to evaluate the video-related impairment is inquired. Second, impact of some of the adaptation technical factors including the quality switching amplitude and chunk size in combination with high range of commercial content type is investigated. The results of this study provide a good insight toward achieving appropriate testing method to evaluate HAS QoE, in addition to designing switching strategies with optimal visual quality.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)