1000 resultados para Difração por raios x


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: Os processos industriais geram grandes quantidades de resíduos, representando um grande desperdício de matéria prima e causando impactos negativos ao meio ambiente. No caso dos resíduos gerados pelas fábricas de pás eólicas para aerogeradores de Sorocaba-S.P., eles podem ser reaproveitados na incorporação em cimento Portland. O interesse é utilizá-los na construção civil como blocos sem fins estruturais para construção de muros, guias, calçadas, pisos, etc. Os corpos confeccionados devem obedecer às normas técnicas brasileiras e as suas propriedades relativas à resistência, compressão, absorção de água e distribuição espacial dos resíduos nestes corpos devem ser avaliadas. Objetivos: Devido à importância de se conhecer as propriedades dos corpos produzidos com a incorporação de resíduos de pás eólicas, este trabalho faz uma avaliação através de imagens de raios X de sua distribuição espacial para verificar a viabilidade do emprego desta técnica no estudo da incorporação de resíduos para, futuramente, em conjunto com outras pesquisas que estão sendo realizadas, verificar a relação desta distribuição com as propriedades mecânicas dos corpos produzidos. Métodos: Objetivando a incorporação desse resíduo como substituto parcial dos agregados miúdos em argamassa, foram fabricados corpos de prova (CPs) seguindo as normas da ABNT-NBR 5738. Todos os corpos foram desmoldados após 24 horas de sua confecção e imersos em água por 28 dias para a cura. Utilizou-se o traço 3:1, areia e cimento, em relação a massa dos componentes, ou seja, para cada 300 g de areia adicionou-se 100 g de cimento. Na confecção de argamassa com resíduo utilizou-se o mesmo traço, porém com a substituição de parte da areia pelo resíduo. Foram fabricados CPs com 5%, 15%, 50% e 0% de resíduo para que este sirva de referência. Como os corpos possuem um formato cilíndrico, foram obtidas imagens em duas projeções: frontal e superior utilizando um equipamento digital com os seguintes parâmetros: 83 kVp e 16 mAs e, 85 kVp e 30 mAs, respectivamente. Resultados: As imagens mostram que na projeção frontal é possível verificar que a distribuição do resíduo nos corpos é homogênea, o que pode proporcionar uniformidade nos resultados de testes de resistência à compressão que serão realizados futuramente. Porém, na projeção superior ainda será necessário um estudo dos parâmetros que deverão ser utilizados no equipamento de raios X para melhorar a sua qualidade. Além disso, métodos de processamento digital de imagens poderão ser aplicados nas imagens para auxiliar na visualização dos resíduos incorporados. Também pode ser visto nas imagens que a forma utilizada para a incorporação do resíduo resulta na sua distribuição uniforme, compatível com o que se deseja neste tipo de incorporação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the classification of 110 copper ore samples from Sossego Mine, based on X-ray diffraction and cluster analysis. The comparison based on the position and the intensity of the diffracted peaks allowed the distinction of seven ore types, whose differences refer to the proportion of major minerals: quartz, feldspar, actinolite, iron oxides, mica and chlorite. There was a strong correlation between the grouping and the location of the samples in Sequeirinho and Sossego orebodies. This relationship is due to different types and intensities of hydrothermal alteration prevailing in each body, which reflect the mineralogical composition and thus the X-ray diffractograms of samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O crescente interesse pelo uso de combustíveis renováveis nos últimos anos fez com que culturas oleaginosas, como a mamona, se tornassem importante objeto de estudo. No entanto, para a instalação de campos desta cultura, é imprescindível o uso de sementes de alta qualidade. O objetivo da pesquisa contida neste trabalho foi verificar a eficiência do teste de raios X na avaliação da qualidade de sementes de mamona após a colheita e armazenamento. Três lotes de sementes da cv. 'IAC-2028' (provenientes, respectivamente, dos racemos primário, secundário e terciário) e dois lotes da cv. 'Guarani' (lotes comerciais com sementes de todos os racemos misturados) foram avaliados de acordo com a morfologia interna pelo teste de raios X, na intensidade de 20 kV por 60 segundos de exposição. Posteriormente, as sementes radiografadas foram submetidas ao teste de germinação de modo a relacionar a morfologia interna das sementes com as respectivas plântulas normais, anormais ou sementes mortas. Após seis meses de armazenamento acondicionadas em sacos de papel Kraft, em condições não controladas de temperatura e umidade relativa do ar, amostras dessas sementes foram novamente avaliadas pelo teste de raios X. O teste de raios X é eficiente para avaliar a morfologia interna das sementes e seus reflexos no potencial fisiológico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reactive Sputter Magnetron (RSM) is a widely used technique to thin films growing of compounds both, in research laboratories and in industrial processes. The nature of the deposited compound will depend then on the nature of the magnetron target and the nature of the ions generated in the plasma. One important aspect of the problem is the knowledge of the evolution of the film during the process of growing itself. In this work, we present the design, construction of a chamber to be installed in the Huber goniometer in the XRD2 line of LNLS in Campinas, which allows in situ growing kinetic studies of thin films.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Selenophosphate synthetase (SPS) plays an indispensable role in selenium metabolism, being responsible for catalyzing the activation of selenide with adenosine 5'-triphosphate (ATP) to generate selenophosphate, the essential selenium donor for selenocysteine synthesis. Recombinant full-length Leishmania major SPS (LmSPS2) was recalcitrant to crystallization. Therefore, a limited proteolysis technique was used and a stable N-terminal truncated construct (ΔN-LmSPS2) yielded suitable crystals. The Trypanosoma brucei SPS orthologue (TbSPS2) was crystallized by the microbatch method using paraffin oil. X-ray diffraction data were collected to resolutions of 1.9 Å for ΔN-LmSPS2 and 3.4 Å for TbSPS2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ferroelectric ceramics with perovskite structure (ABO3) are widely used in solid state memories (FeRAM’s and DRAM's) as well as multilayered capacitors, especially as a thin films. When doped with zirconium ions, BaTiO3-based materials form a solid solution known as barium zirconate titanate (BaTi1-xZrxO3). Also called BZT, this material can undergo significant changes in their electrical properties for a small variation of zirconium content in the crystal lattice. The present work is the study of the effects of deposition parameters of BaTi0,75Zr0,25O3 thin films by spin-coating method on their morphology and physical properties, through an experimental design of the Box-Behnken type. The resin used in the process has been synthesized by the polymeric precursor method (Pechini) and subsequently split into three portions each of which has its viscosity adjusted to 10, 20 and 30 mPa∙s by means of a rotary viscometer. The resins were then deposited on Pt/Ti/SiO2/Si substrates by spin-coating method on 15 different combinations of viscosity, spin speed (3000, 5500 and 8000 rpm) and the number of deposited layers (5, 8 and 11 layers) and then calcined at 800 ° C for 1 h. The phase composition of the films was analyzed by X-ray diffraction (XRD) and indexed with the JCPDS 36-0019. Surface morphology and grain size were observed by atomic force microscopy (AFM) indicating uniform films and average grain size around 40 nm. Images of the cross section of the films were obtained by scanning electron microscopy field emission (SEM-FEG), indicating very uniform thicknesses ranging from 140-700 nm between samples. Capacitance measurements were performed at room temperature using an impedance analyzer. The films presented dielectric constant values of 55-305 at 100kHz and low dielectric loss. The design indicated no significant interaction effects between the deposition parameters on the thickness of the films. The response surface methodology enabled better observes the simultaneous effect of variables.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The micro-deformations caused by cyclic loading origins the variation of the distances between atoms of the crystal lattice producing the irreversible component. In order to study and understand the microstructural behavior of the material this paper investigated the influence suffered by residual stresses in thrust rolling bearing races fabricated in AISI 52100 steel, after tests by cyclic rolling contact in a tribometer at 1m/s under two contact pressures (500 MPa and 1400 MPa) in dry and boundary lubrication conditions. Procedures of tests thermo-acustically isolated were developed for monitoring the contact temperature and sound pressure level signals to establish a comparison between the residual stress measurements, micro-hardness Vickers and micrographic registers searching an indication of wear evolution. The sin²ψ method by X-ray diffraction technique was used to quantify the residual stresses. Three raceway zones were selected for the evaluation of wear and surface morphology after predetermined cycling, comparing with their new condition ("as received"). Micro-hardness and residual stress measurements showed significant changes after the tests and it was possible to observe the relationship between the increase of sound pressure level and the residual stress for dry and lubricated conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The micro-deformations caused by cyclic loading origins the variation of the distances between atoms of the crystal lattice producing the irreversible component. In order to study and understand the microstructural behavior of the material this paper investigated the influence suffered by residual stresses in thrust rolling bearing races fabricated in AISI 52100 steel, after tests by cyclic rolling contact in a tribometer at 1m/s under two contact pressures (500 MPa and 1400 MPa) in dry and boundary lubrication conditions. Procedures of tests thermo-acustically isolated were developed for monitoring the contact temperature and sound pressure level signals to establish a comparison between the residual stress measurements, micro-hardness Vickers and micrographic registers searching an indication of wear evolution. The sin²ψ method by X-ray diffraction technique was used to quantify the residual stresses. Three raceway zones were selected for the evaluation of wear and surface morphology after predetermined cycling, comparing with their new condition ("as received"). Micro-hardness and residual stress measurements showed significant changes after the tests and it was possible to observe the relationship between the increase of sound pressure level and the residual stress for dry and lubricated conditions.