883 resultados para Diffuse adherence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been much progress in recent years in the analysis of complex random vibro-acoustic systems, and general analysis methods have been developed which are based on the properties of diffuse wave fields. It is shown in the present paper that such methods can also be applied to high frequency EMC problems, avoiding the need for costly full wave solutions to Maxwell's equations in complex cavities. The theory behind the approach is outlined and then applied to the relatively simple case of a wiring system which is subject to reverberant electromagnetic wave excitation. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interface diffusion, reaction, and adherence of rapid thermal annealed Ti/ALN were investigated by RES, AES, SIMS, XRD and a scratch test. The experimental results show that diffusion and reaction occurs at the interface of Ti/AlN when the sample is rapidly annealed. During annealing, both the O adsorbed on the surface and doped in the AlN substrate diffuse into the Ti film. At low temperature TiO2 is produced. At higher temperature O reacts with the diffused Al in the Ti film and produces an Al2O3 layer in the middle of the film. N diffuses into the Ti film and produces TiN with an interface reaction. Ti oxide is produced at the interface between the film and the substrate. Scratch test results show that interface adherence is distinctly improved by rapid annealing at low temperature and decreases at higher temperature. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution X-ray diffraction has been employed to investigate the diffuse scattering in a (0001) oriented GaN epitaxial film grown on sapphire substrate. The analysis reveals that defect clusters are present in GaN films and their concentration increases as the density of threading dislocations increases. Meanwhile, the mean radius of these defect clusters shows a reverse tendency. This result is explained by the effect of clusters preferentially forming around dislocations, which act as effective sinks for the segregation of point defects. The electric mobility is found to decrease as the cluster concentration increases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acousto-optic imaging (AOI) in optically diffuse media is a hybrid imaging modality in which a focused ultrasound beam is used to locally phase modulate light inside of turbid media. The modulated optical field carries with it information about the optical properties in the region where the light and sound interact. The motivation for the development of AOI systems is to measure optical properties at large depths within biological tissue with high spatial resolution. A photorefractive crystal (PRC) based interferometry system is developed for the detection of phase modulated light in AOI applications. Two-wave mixing in the PRC creates a reference beam that is wavefront matched to the modulated optical field collected from the specimen. The phase modulation is converted to an intensity modulation at the optical detector when these two fields interfere. The interferometer has a high optical etendue, making it well suited for AOI where the scattered light levels are typically low. A theoretical model for the detection of acoustically induced phase modulation in turbid media using PRC based interferometry is detailed. An AOI system, using a single element focused ultrasound transducer to pump the AO interaction and the PRC based detection system, is fabricated and tested on tissue mimicking phantoms. It is found that the system has sufficient sensitivity to detect broadband AO signals generated using pulsed ultrasound, allowing for AOI at low time averaged ultrasound output levels. The spatial resolution of the AO imaging system is studied as a function of the ultrasound pulse parameters. A theoretical model of light propagation in turbid media is used to explore the dependence of the AO response on the experimental geometry, light collection aperture, and target optical properties. Finally, a multimodal imaging system combining pulsed AOI and conventional B- mode ultrasound imaging is developed. B-mode ultrasound and AO images of targets embedded in both highly diffuse phantoms and biological tissue ex vivo are obtained, and millimeter resolution is demonstrated in three dimensions. The AO images are intrinsically co-registered with the B-mode ultrasound images. The results suggest that AOI can be used to supplement conventional B-mode ultrasound imaging with optical information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Copayments for prescriptions are associated with decreased adherence to medicines resulting in increased health service utilisation, morbidity and mortality. In October 2010 a 50c copayment per prescription item was introduced on the General Medical Services (GMS) scheme in Ireland, the national public health insurance programme for low-income and older people. The copayment was increased to €1.50 per prescription item in January 2013. To date, the impact of these copayments on adherence to prescription medicines on the GMS scheme has not been assessed. Given that the GMS population comprises more than 40% of the Irish population, this presents an important public health problem. The aim of this thesis was to assess the impact of two prescription copayments, 50c and €1.50, on adherence to medicines.Methods: In Chapter 2 the published literature was systematically reviewed with meta-analysis to a) develop evidence on cost-sharing for prescriptions and adherence to medicines and b) develop evidence for an alternative policy option; removal of copayments. The core research question of this thesis was addressed by a large before and after longitudinal study, with comparator group, using the national pharmacy claims database. New users of essential and less-essential medicines were included in the study with sample sizes ranging from 7,007 to 136,111 individuals in different medication groups. Segmented regression was used with generalised estimating equations to allow for correlations between repeated monthly measurements of adherence. A qualitative study involving 24 individuals was conducted to assess patient attitudes towards the 50c copayment policy. The qualitative and quantitative findings were integrated in the discussion chapter of the thesis. The vast majority of the literature on this topic area is generated in North America, therefore a test of generalisability was carried out in Chapter 5 by comparing the impact of two similar copayment interventions on adherence, one in the U.S. and one in Ireland. The method used to measure adherence in Chapters 3 and 5 was validated in Chapter 6. Results: The systematic review with meta-analysis demonstrated an 11% (95% CI 1.09 to 1.14) increased odds of non-adherence when publicly insured populations were exposed to copayments. The second systematic review found moderate but variable improvements in adherence after removal/reduction of copayments in a general population. The core paper of this thesis found that both the 50c and €1.50 copayments on the GMS scheme were associated with larger reductions in adherence to less-essential medicines than essential medicines directly after the implementation of policies. An important exception to this pattern was observed; adherence to anti-depressant medications declined by a larger extent than adherence to other essential medicines after both copayments. The cross country comparison indicated that North American evidence on cost-sharing for prescriptions is not automatically generalisable to the Irish setting. Irish patients had greater immediate decreases of -5.3% (95% CI -6.9 to -3.7) and -2.8% (95% CI -4.9 to -0.7) in adherence to anti-hypertensives and anti-hyperlipidaemic medicines, respectively, directly after the policy changes, relative to their U.S. counterparts. In the long term, however, the U.S. and Irish populations had similar behaviours. The concordance study highlighted the possibility of a measurement bias occurring for the measurement of adherence to non-steroidal anti-inflammatory drugs in Chapter 3. Conclusions: This thesis has presented two reviews of international cost-sharing policies, an assessment of the generalisability of international evidence and both qualitative and quantitative examinations of cost-sharing policies for prescription medicines on the GMS scheme in Ireland. It was found that the introduction of a 50c copayment and its subsequent increase to €1.50 on the GMS scheme had a larger impact on adherence to less-essential medicines relative to essential medicines, with the exception of anti-depressant medications. This is in line with policy objectives to reduce moral hazard and is therefore demonstrative of the value of such policies. There are however some caveats. The copayment now stands at €2.50 per prescription item. The impact of this increase in copayment has yet to be assessed which is an obvious point for future research. Careful monitoring for adverse effects in socio-economically disadvantaged groups within the GMS population is also warranted. International evidence can be applied to the Irish setting to aid in future decision making in this area, but not without placing it in the local context first. Patients accepted the introduction of the 50c charge, however did voice concerns over a rising price. The challenge for policymakers is to find the ‘optimal copayment’ – whereby moral hazard is decreased, but access to essential chronic disease medicines that provide advantages at the population level is not deterred. This evidence presented in this thesis will be utilisable for future policy-making in Ireland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose an estimation-theoretic approach to the inference of an incoherent 3D scattering density from 2D scattered speckle field measurements. The object density is derived from the covariance of the speckle field. The inference is performed by a constrained optimization technique inspired by compressive sensing theory. Experimental results demonstrate and verify the performance of our estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We conducted a pilot study on 10 patients undergoing general surgery to test the feasibility of diffuse reflectance spectroscopy in the visible wavelength range as a noninvasive monitoring tool for blood loss during surgery. Ratios of raw diffuse reflectance at wavelength pairs were tested as a first-pass for estimating hemoglobin concentration. Ratios can be calculated easily and rapidly with limited post-processing, and so this can be considered a near real-time monitoring device. We found the best hemoglobin correlations were when ratios at isosbestic points of oxy- and deoxyhemoglobin were used, specifically 529/500 nm. Baseline subtraction improved correlations, specifically at 520/509 nm. These results demonstrate proof-of-concept for the ability of this noninvasive device to monitor hemoglobin concentration changes due to surgical blood loss. The 529/500 nm ratio also appears to account for variations in probe pressure, as determined from measurements on two volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations which were used to extract hemoglobin concentration from experimental phantom measurements. Linear regression coefficients from the simulated data were directly applied to the phantom data, by calibrating for instrument throughput using a single phantom. Phantoms with variable scattering and hemoglobin saturation were tested with two different instruments, and the average percent errors between the expected and ratiometrically-extracted hemoglobin concentration were as low as 6.3%. A correlation of r = 0.88 between hemoglobin concentration extracted using the 529/390 nm isosbestic ratio and a scalable inverse Monte Carlo model was achieved for in vivo dysplastic cervical measurements (hemoglobin concentrations have been shown to be diagnostic for the detection of cervical pre-cancer by our group). These results indicate that use of such a simple ratiometric method has the potential to be used in clinical applications where tissue hemoglobin concentrations need to be rapidly quantified in vivo.