960 resultados para Diagnostic, methods comparison


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The enormous amount of information generated through sequencing of the human genome has increased demands for more economical and flexible alternatives in genomics, proteomics and drug discovery. Many companies and institutions have recognised the potential of increasing the size and complexity of chemical libraries by producing large chemical libraries on colloidal support beads. Since colloid-based compounds in a suspension are randomly located, an encoding system such as optical barcoding is required to permit rapid elucidation of the compound structures. We describe in this article innovative methods for optical barcoding of colloids for use as support beads in both combinatorial and non-combinatorial libraries. We focus in particular on the difficult problem of barcoding extremely large libraries, which if solved, will transform the manner in which genomics, proteomics and drug discovery research is currently performed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy The recent publication of a randomised controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO(2)) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery FSpO(2) monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of maternal epidural analgesia in labor may be associated with nonreassuring fetal heart rate (FHR) patterns. Fetal oxygen saturation (FSpO(2)) monitoring may improve assessment of fetal well-being during this time. Mean FSpO(2) values were compared over seven 5-minute epochs: 5 minutes prior to an epidural event (combined insertion of epidural/top-up epidural analgesia and infusion pump bolus), to 30 minutes following the event, including possible effects of maternal position and FHR pattern on FSpO(2) values. Mean FSpO(2) values were significantly different between the 5 minutes prior (49.5%) versus 16-20 minutes (44.3%, p

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective : To establish the CO2 dispersion and retention properties of some mattresses and bed coverings commercially available in Australia. Methods : Five mattresses were studied in (i) an in vivo model in which an infant's head was covered by a headbox, rebreathing was allowed to occur, and the final steady state CO2 concentration was measured; and (ii) an in vitro model in which 5% CO2 in a headbox was allowed to disperse, and the time taken for the concentration to reach 1% was measured. Five types of bedcover were studied in (i) an in vivo model in which an infant's head was covered by a bedcover and the final steady state CO2 concentration was measured; and (ii) an in vitro model in which 5% CO2 under a bedcover was allowed to disperse, and the time taken for the concentration to reach 1% was measured. Results : The steady state CO2 concentrations ranged from 0.6% to 3.0% for the mattresses (P < 0.05). The time for CO2 to disperse ranged from 5.5 min to 30.4 min (P < 0.05). Steady state CO2 concentrations ranged from 2.5% to 3.6% for the bedcoverings (P > 0.05). The time for CO2 to disperse ranged from 5.4 min to 7.7 min (P > 0.05). Conclusions : Some commercial cot mattresses and bedcoverings allow high concentrations of CO2 to accumulate in rebreathing environments. Some mattress types studied were more diffusive to CO2 , whereas there was no difference between the bedcovers studied. This may have implications for vulnerable infants at risk of sudden infant death syndrome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High-throughput screening (HTS) using high-density microplates is the primary method for the discovery of novel lead candidate molecules. However, new strategies that eschew 2D microplate technology, including technologies that enable mass screening of targets against large combinatorial libraries, have the potential to greatly increase throughput and decrease unit cost. This review presents an overview of state-of-the-art microplate-based HTS technology and includes a discussion of emerging miniaturized systems for HTS. We focus on new methods of encoding combinatorial libraries that promise throughputs of as many as 100 000 compounds per second.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report here a validated method for the quantification of a new immunosuppressant drug, everolimus (SDZ RAD), using HPLC-tandem mass spectrometry. Whole blood samples (500 mul) were prepared by protein precipitation, followed by C-18 solid-phase extraction. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface operating in positive ionization mode. The assay was linear from 0.5 to 100 mug/l (r(2) > 0.996, n = 9). The analytical recovery and inter-day imprecision, determined using whole blood quality control samples (n = 5) at 0.5, 1.2, 20.0, and 75.0 mug/l, was 100.3-105.4% and less than or equal to7.6%, respectively. The assay had a mean relative recovery of 94.8 +/- 3.8%. Extracted samples were stable for up to 24 h. Fortified everolimus blood samples were stable at -80 degreesC for at least 8 months and everolimus was found to be stable in blood when taken through at least three freeze-thaw cycles. The reported method provides accurate, precise and specific measurement of everolimus in blood over a wide analytical range and is currently supporting phase 11 and III clinical trials. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Inherited copper toxicosis was diagnosed in a Bedlington Terrier using conventional diagnostic methods such as plasma biochemistry, hepatic copper assay, histology and electron microscopy and a recently developed DNA microsatellite marker test. The dog was successfully managed using D-penicillamine and a low copper diet.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A detailed analysis procedure is described for evaluating rates of volumetric change in brain structures based on structural magnetic resonance (MR) images. In this procedure, a series of image processing tools have been employed to address the problems encountered in measuring rates of change based on structural MR images. These tools include an algorithm for intensity non-uniforniity correction, a robust algorithm for three-dimensional image registration with sub-voxel precision and an algorithm for brain tissue segmentation. However, a unique feature in the procedure is the use of a fractional volume model that has been developed to provide a quantitative measure for the partial volume effect. With this model, the fractional constituent tissue volumes are evaluated for voxels at the tissue boundary that manifest partial volume effect, thus allowing tissue boundaries be defined at a sub-voxel level and in an automated fashion. Validation studies are presented on key algorithms including segmentation and registration. An overall assessment of the method is provided through the evaluation of the rates of brain atrophy in a group of normal elderly subjects for which the rate of brain atrophy due to normal aging is predictably small. An application of the method is given in Part 11 where the rates of brain atrophy in various brain regions are studied in relation to normal aging and Alzheimer's disease. (C) 2002 Elsevier Science Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present global and regional rates of brain atrophy measured on serially acquired T1-weighted brain MR images for a group of Alzheimer's disease (AD) patients and age-matched normal control (NC) subjects using the analysis procedure described in Part I. Three rates of brain atrophy: the rate of atrophy in the cerebrum, the rate of lateral ventricular enlargement and the rate of atrophy in the region of temporal lobes, were evaluated for 14 AD patients and 14 age-matched NC subjects. All three rates showed significant differences between the two groups, However, the greatest separation of the two groups was obtained when the regional rates were combined. This application has demonstrated that rates of brain atrophy, especially in specific regions of the brain, based on MR images can provide sensitive measures for evaluating the progression of AD. These measures will be useful for the evaluation of therapeutic effects of novel therapies for AD. (C) 2002 Elsevier Science Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: The aims of this study were to investigate the population pharmacokinetics of tacrolimus in adult kidney transplant recipients and to identify factors that explain variability. Methods: Population analysis was performed on retrospective data from 70 patients who received oral tacrolimus twice daily. Morning blood trough concentrations were measured by liquid chromatography-tandem mass spectrometry. Maximum likelihood estimates were sought for apparent clearance (CL/F) and apparent volume of distribution (V/F), with the use of NONMEM (GloboMax LLC, Hanover, Md). Factors screened for influence on these parameters were weight, age, gender, postoperative day, days of tacrolimus therapy, liver function tests, creatinine clearance, hematocrit fraction, corticosteroid dose, and potential interacting drugs. Results. CL/F was greater in patients with abnormally low hematocrit fraction (data from 21 patients only), and it decreased with increasing days of therapy and AST concentrations (P

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective To develop and validate specific, sensitive and rapid diagnostic tests using RT-PCR for the detection of Ross River virus (RRV), Kunjin virus (KV) and Murray Valley encephalitis virus (MVEV) infections in horses. Methods Primer sets based on nucleotide sequence encoding the envelope glycoprotein E2 of RRV and on the nonstructural protein 5 (NS5) of KV and MVEV were designed and used in single round PCRs to test for the respective viruses in infected cell cultures and, in the case of RRV, in samples of horse blood and synovial fluid. Results The primer pairs designed for each of the three viruses amplified a product of expected size from prototype viruses that were grown in cell culture. The identity of each of the products was confirmed by nucleotide sequencing indicating that in the context used the RT-PCRs were specific. RRV was detected in serums from 8 horses for which there were clinical signs consistent with RRV infection such that an acute-phase serum sample was taken and submitted for RRV serology testing. The RRV RT-PCR was analytically sensitive in that it was estimated to detect as little as 50 TCID50 of RRV per mL of serum and was specific in that the primer pairs did not amplify other products from the 8 serum samples. The RRV primers also detected virus in three independent mosquito pools known to contain RRV by virus isolation in cell culture. Samples from horses suspected to be infected with KV and MVEV were not available. Conclusion Despite much anecdotal and serological evidence for infection of horses with RRV actual infection and associated clinical disease are infrequently confirmed. The availability of a specific and analytically sensitive RT-PCR for the detection of RRV provides additional opportunities to confirm the presence of this virus in clinical samples. The RTPCR primers for the diagnosis of KV and MVEV infections were shown to be specific for cell culture grown viruses but the further validation of these tests requires the availability of appropriate clinical samples from infected horses.