408 resultados para Dentures
Resumo:
An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Objective: The purpose of this in vitro study was to evaluate the antimicrobial activity of acrylic resins containing different percentages of silver and zinc zeolite, and to assess whether the addition of zeolite alters the flexural and impact strength of the resins. Background: The characteristics of acrylic resins support microorganism development that can threaten the health of the dentures user. Material and methods: A microwave-polymerised (Onda-Cryl) and two heat-polymerised (QC20 and Lucitone 550) acrylic resins were used. The materials were handled according to the manufacturers` instructions. Fifty rectangular-shaped specimens (8 x 10 x 4mm) were fabricated from each resin and assigned to 5 groups (n = 10) according to their percentage of Irgaguard B5000 silver-zinc zeolite (0%- control, 2.5%, 5.0%, 7.5% and 10%). Flexural strength and Izod impact strength were evaluated. The antimicrobial activity against two strains of Candida albicans and two strains of Streptococcus mutans was assessed by agar diffusion method. Data were analysed statistically by one-way ANOVA and Tukey`s test at 5% significance level. Results: The addition of 2.5% of Irgaguard B5000 to the materials resulted in antimicrobial activity against all strains. Flexural strength decreased significantly with the addition of 2.5% (QC20 and Lucitone 550) and 5.0% (Onda-Cryl) of Irgaguard B5000. The impact strength decreased significantly with the addition of 2.5% (Lucitone 550) and 5.0% (QC20 and Onda-Cryl) of zeolite. Conclusion: The addition of silver-zinc zeolite to acrylic resins yields antimicrobial activity, but may affect negatively the mechanical properties, depending on the percentage of zeolite.
Resumo:
P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.
Resumo:
To study the physical properties of two experimental dentifrices for complete denture hygiene, their effect on denture biofilm removal and antimicrobial properties by means of a clinical trial. The experimental dentifrices comprised two compositions. One was based on the addition of 1% chloramine T (D1) and the other on the presence of 0.01% fluorosurfactant (D2). Measurements of density, pH, consistency, rheological features and abrasiveness were conducted. Sixty complete denture wearers were randomly assigned to three groups and were instructed to brush their dentures with a specific toothbrush: (1) Water (control); (2) D1; or (3) D2. Each method was used for 21 days. Denture biofilm was disclosed by a 1% neutral red solution and quantified by means of digital photos taken from the internal surface. Microbiological assessment was conducted to quantify Candida sp. and mutans streptococci. Data were evaluated by one-way anova and Tukey HSD, or Kruskal-Wallis (alpha = 0.05). Both dentifrices decreased biofilm coverage when compared with the control group. D1 was the most efficacious treatment to reduce mutans streptococci, whereas D2 showed an intermediate outcome (anova, p < 0.040). No treatment influenced Candida albicans or non-albicans species (Kruskal-Wallis, p = 0.163 and 0.746, respectively). It can be concluded that brushing complete dentures with the experimental dentifrices tested could be effective for the removal of denture biofilm.
Resumo:
P>The use of seven domains for the Oral Health Impact Profile (OHIP)-EDENT was not supported for its Brazilian version, making data interpretation in clinical settings difficult. Thus, the aim of this study was to assess patients` responses for the translated OHIP-EDENT in a group of edentulous subjects and to develop factor scales for application in future studies. Data from 103 conventional and implant-retained complete denture wearers (36 men, mean age of 69 center dot 1 +/- 10 center dot 3 years) were assessed using the Brazilian version of the OHIP-EDENT. Oral health-related quality of life domains were identified by factor analysis using principal component analysis as the extraction method, followed by varimax rotation. Factor analysis identified four factors that accounted for 63% of the 19 items total variance, named masticatory discomfort and disability (four items), psychological discomfort and disability (five items), social disability (five items) and oral pain and discomfort (five items). Four factors/domains of the Brazilian OHIP-EDENT version represent patient-important aspects of oral health-related quality of life.
Resumo:
The aim of this study was to investigate oral yeast colonization, antifungal susceptibility and strain diversity in insulin-dependent diabetes mellitus patients (175), as well as to evaluate the influence of dental prostheses. Oral rinse samples were cultured on selective media, in order to isolate, count and identify the yeasts recovered. More than half of the diabetic subjects (53%) carried significant amounts of Candida cells in the buccal cavity and these organisms were recovered at higher densities in diabetics wearing dentures. A total of 93 yeast strains were isolated from these patients, including: Candida spp. (n = 89); Pichia (n = 02); Trichosporon (n = 1), and Geotrichum (n = 1). C. albicans represented 56% of these strains, non-albicans Candida 39.8%, and other genera of yeast 4.3%. C. albicans was prevalent, followed by C. parapsilosis, C. tropicalis, C. glabrata, C. krusei, C. rugosa and C. guilliermondii. Agar disk-diffusion tests of the susceptibility of non-albicans Candida and other genera of yeast to fluconazole showed resistance in 21.9%, mainly in C. rugosa (100%), C. glabrata (57%) and C. krusei (50%). Local oral factors, such as the presence of dentures, in association with diabetes, seemed to have the effect of increasing the amount and variety of Candida species in the oral cavities, mainly those with lower drug susceptibilities.
Resumo:
The maintenance of masticatory function is especially important for patients who wear complete dentures due to the limitations of this type of prosthesis. Thus, the bilateral balanced occlusion (BBO) is used to achieve, besides other advantages, greater masticatory efficiency. However, analyzing critically the literature, it is observed that there is not enough scientific evidence that support the BBO as the most appropriate occlusal concept in complete dentures. This way, the purpose of the present study was to verify if complete dentures wearers with BBO present better masticatory efficiency and capacity than those with canine guidance (CG). A double-blind controlled crossover clinical trial was conducted. The sample was made of 24 completely edentulous patients. The subjects wore sets of complete dentures with both occlusal concepts for equal periods of 3 months. Objective data were collected through the masticatory efficiency test, performed by the colorimetric method, in which capsules of a synthetic material enclosing fuchsine- containing granules were used. Subjective data were recorded by patient´s ratings of their chewing function, which is the masticatory ability. No significant statistical difference was found for masticatory efficiency (p=0,0952) and masticatory ability (x2=0,5711/ p=0,4498) between the two occlusal concepts studied, as well as there was no correlation between these two variables (p=0,2985). Based on these results, it seems reasonable to use CG for the setup of complete dentures, since it is an easier and quicker technical procedure, until that future researches can come to complement this question
Resumo:
Aim: To evaluate user satisfaction and quality of prosthetic treatments performed in specialized dental clinics (CEOs) of Natal Metropolitan Region - RN. Methods: Cross-sectional study with subjects who underwent prosthetic CEOs in the cities of Natal, Macaíba, Parnamirim and Sao Goncalo do Amarante in the period 2007 to 2009. Data collection was performed by questionnaire, clinical examination of the oral cavity and examination of fabricated denture. This analysis involved the following aspects: retention, stability, aesthetics and prosthesis fixation. The variables are presented by means of absolute numbers and proportions. The determination of the association between the independent and dependent variables was conducted by the association of Chi-square test and Fisher exact test. Results: A total of 149 users, totaling 233 conventional dentures (148 upper and 85 lower). Most patients (56.4%) were rehabilitated with conventional complete dentures. The technical quality of the denture was regarded as satisfactory in the majority (52.7%), whereas the inferior dentures were rated as unsatisfactory in 90.5% of cases. Satisfaction with the prosthesis was 69.1% (N = 103). The average time to begin treatment was 3 months to receive while the prosthesis was 4 months old. The presence of injury from the upper prosthesis occurred in 21.5% of cases (N = 32), candidiasis being the most frequent (N = 18). The technical quality of the upper prosthesis (p=0,041), as well as retention (p=0,002) and stability (p<0,001) were significantly associated with user satisfaction. Conclusions: The specialized Dental clinics has been fulfilling its role of providing treatment of intermediate complexity for low-income population with the majority of satisfield patients, even when their dentures have problems of technical quality
Resumo:
This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study
Resumo:
Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures
Falhas e complicações com o uso de prótese parcial removível inferior de extremidade livre bilateral
Resumo:
Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls
Resumo:
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and Methods:Two models were made of photoelastic resin PL-2, with an internal hexagon implant of 4.00 x 13 mm and another with an external hexagon implant of 4.00 x 13 mm. Three denture designs were fabricated for each implant model, incorporating one type of connection in each one to connect implants and teeth: 1) welded rigid connection; 2) semirigid connection; and 3) rigid connection with occlusal screw. The models were placed in the polariscope, and 100-N axial forces were applied on fixed points on the occlusal surface of the dentures.Results:There was a trend toward less intensity in the stresses on the semirigid connection and solid rigid connection in the model with the external hexagon; among the three types of connections in the model with the internal hexagon implant, the semirigid connection was the most unfavorable one; in the tooth-implant association, it is preferable to use the external hexagon implant.Conclusions:The internal hexagon implant establishes a greater depth of hexagon retention and an increase in the level of denture stability in comparison with the implant with the external hexagon. However, this greater stability of the internal hexagon generated greater stresses in the abutment structures. Therefore, when this association is necessary, it is preferable to use the external hexagon implant.
Resumo:
The peripheral ossifying fibroma (POF) is a common gingival growth usually arising from the interdental papilla. The anterior maxilla is the most common location of involvement. The etiology and pathogenesis of POF remains unknown. Some investigators consider it a neoplastic process, whereas others argue that it is a reactive process; in either case, the lesion is thought to arise from cells in the periodontal ligament. Trauma or local irritants, such as dental plaque, calculus, microorganisms, masticatory force, ill-fitting dentures, and poor quality restorations, have been implicated in the etiology of POF. The recommended treatment is the excisional biopsy; however, it can leave a defect if the procedure is not followed by a subepithelial connective tissue graft. The main objective of this article was to present a clinical case of excisional biopsy of a POF followed by a subepithelial connective tissue graft to correct the defect caused by the biopsy. The biopsy defect was satisfactorily repaired, and the lesion has not recurred after 6 years of follow-up.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Classico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acrylic (Jet) resins were used. Five groups were established, according to polymerization cycles: A, B and C (Onda-Cryl, short cycle - 500W/3 min, long - 90W/13 min + 500W/90 see, and manufacturing microwave cycle - 320W/3 min + OW/3 min + 720W/3 min); T(Classico, water bath cycle - 74 degrees C/9h) and Q (Jet, press chamber cycle - 50 degrees C/15 min at 2 bar). Ten specimens (65 x 10 x 3.3 mm) were prepared for each cycle. The flexural strength of the five groups was measured using a three-point bending test at a cross-head speed of 5 mm/min. Flexural strength values were analyzed by one-way ANOVA and the Tukey's test was performed to identify the groups that were significantly different at 5% level. The microwave-polymerized groups showed the highest means (p<0.05) for flexural strength (MPa) (A = 106.97 +/- 5.31; B = 107.57 +/- 3.99; C = 109.63 +/- 5.19), and there were no significant differences among them. The heat-polymerized group (T) showed the lowest flexural strength means (84.40 +/- 1.68), and differ significantly from all groups. The specimens of a microwavable denture base resin could be polymerized by different microwave cycles without risk of decreasing the flexural strength.