1000 resultados para Dentin depth


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper an electrically controllable radial birefringent pupil filter is proposed. It consists of two polarizers and an improved electrically controllable optical azimuth rotator which has two lambda/4 retarders, one electro-optical crystal and one radial birefringent crystal. The evolution and distribution of polarization states of this pupil filter are discussed. The most interesting and useful advantage of such a structure is that the characteristic of transverse superresolution and axial extended focal depth or focal shift can be obtained merely by controlling the applied voltage on the electro-optical crystal. The radial birefringent crystal azimuth angle cooperating with different electrical inductive phase differences will determine the transverse and axial intensity distribution. It is shown that for particular ranges of electrical inductive phase difference it is possible to obtain transverse superresolution along with extended focal depth or with a focal shift.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nuclear resonant reaction 19F(ρ,αγ)16O has been used to perform depth-sensitive analyses of fluorine in lunar samples and carbonaceous chondrites. The resonance at 0.83 MeV (center-of-mass) in this reaction is utilized to study fluorine surface films, with particular interest paid to the outer micron of Apollo 15 green glass, Apollo 17 orange glass, and lunar vesicular basalts. These results are distinguished from terrestrial contamination, and are discussed in terms of a volcanic origin for the samples of interest. Measurements of fluorine in carbonaceous chondrites are used to better define the solar system fluorine abundance. A technique for measurement of carbon on solid surfaces with applications to direct quantitative analysis of implanted solar wind carbon in lunar samples is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A review article detailing the background, development and functionality of the Windermere Profiler, a multi parameter environmental monitoring instrument for use in lakes, reservoirs and rivers. The article explains the requirement for regular data collection by the Freshwater Biological Association at Windermere. The article covers the requirements of a profiling instrument, the design considerations, the electronic circuitry, the computer program, the operation of the computer software, the profiler in use and further developments to the design. A number of figures and images accompany the article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The resonant nuclear reaction 19F(p,αy)16O has been used to perform depth-sensitive analyses for both fluorine and hydrogen in solid samples. The resonance at 0.83 MeV (center-of-mass) in this reaction has been applied to the measurement of the distribution of trapped solar protons in lunar samples to depths of ~1/2µm. These results are interpreted in terms of a redistribution of the implanted H which has been influenced by heavy radiation damage in the surface region. Fluorine determinations have been performed in a 1-µm surface layer on lunar and meteoritic samples using the same 19F(p,αy)16O resonance. The measurement of H depth distributions has also been used to study the hydration of terrestrial obsidian, a phenomenon of considerable archaeological interest as a means of dating obsidian artifacts. Additional applications of this type of technique are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sampling was concentrated on the North Moor region and the series of ditches which drained this area to the Bristol Channel. Although most ditches were not deep the mud substratum precluded sampling from within the habitat. All samples were taken with a pond net from the banks. Efforts were made to sample each part of the habitat although in some ditches the macrophyte growth was so intense as to make sampling difficult particularly of the sediments. Organisms were identified on the 10 sampling sites.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-density optical data storage requires high-numerical-aperture (NA) lenses and short wavelengths, But, with increasing NA and decreasing wavelength, the depth of focus (DOF) decreases rapidly. We propose to use pure-phase superresolution apodizers to optimize the axial intensity distribution and extend the DOF of an optical pickup. With this kind of apodizer, the expected DOF can be 2-4.88 times greater than that of the original system, and the spot size will be smaller than that of the original system. (C) 2001 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose the use of a phase-shifting apodizers to increase focal depth, and we study the axial and radial behavior of this kind of apodizer under the condition that the axial intensity distribution is optimized for high focal depth. (C) 2002 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The axial intensity distribution and focal depth of an apoclized focusing optical system are theoretically investigated with two kinds of incident light fields: a uniform-intensity-distribution beam and a Gaussian beam. Both a low-numerical-aperture and a high-numerical-aperture optical system are considered. Numerical results show that the depth of focus can be adjusted by changing the geometrical parameters and transmissivity of the apodizer in the focusing optical system. When a Gaussian beam is employed as the incident beam, the waist width also affects the depth of focus. The tunable range of the focal depth is very considerable. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The axial intensity distribution and focal depth of an apoclized focusing optical system are theoretically investigated with two kinds of incident light fields: a uniform-intensity-distribution beam and a Gaussian beam. Both a low-numerical-aperture and a high-numerical-aperture optical system are considered. Numerical results show that the depth of focus can be adjusted by changing the geometrical parameters and transmissivity of the apodizer in the focusing optical system. When a Gaussian beam is employed as the incident beam, the waist width also affects the depth of focus. The tunable range of the focal depth is very considerable. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work I present recent scientific papers related to the concept of tree-depth: different characterizations, a game theoretic approach to it and recently discovered applications. The focus in this work is presenting all the ideas in a self-contained way, such that they can be easily understood with little previous knowledge. Apart from that all the ideas are presented in a homogeneous way with clear examples and all the lemmas, some of which didn’t have proofs in the papers, are presented with rigorous proofs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo visa avaliar a influência da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro em diferentes regiões do conduto radicular (cervical, médio e apical), cimentados com cimento resinoso autoadesivo, com e sem a adição de Rodamina B, por meio do teste de push-out. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Após sete dias, os condutos foram desobstruídos e aleatoriamente divididos em 4 grupos (n=10), de acordo com as brocas do sistema de pinos de fibra WhitePost DC (FGM) usadas: (G1) broca #2; (G2) broca #3; (G3) broca #4; (G4) broca #2. O preparo foi realizado a uma profundidade de 10 mm. A cimentação foi realizada com o cimento resinoso autoadesivo RelyX U100 (3M ESPE), e apenas nos grupos G1, G2 e G3 uma pequena quantidade de Rodamina B em pó foi usada como corante no cimento. Após uma semana, cada raiz foi seccionada em máquina de corte, obtendo-se 6 fatias de 1 0,1 mm de espessura. Antes do ensaio de push-out, imagens digitais foram obtidas, por meio de um estereomicroscópio, de ambas as faces de cada fatia, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram obtidas para determinação do modo de falha. Para determinar a espessura de cimento, foi desenvolvida uma rotina (macro) no software KS 400. Os dados foram estatisticamente analisados com análise de variância (ANOVA) 2 fatores (influência do diâmetro da broca e influência dos terços) e Kruskal-Wallis (influência da espessura do filme de cimento). Comparações múltiplas foram realizadas com o teste Duncan. Todos os testes foram aplicados com α=0,05. Houve diferenças significantes entre os grupos em relação ao diâmetro da broca (p<0,0001), sendo G2 (14,62 5,15 MPa) > G1 (10,04 5,13 MPa) > G3 (7,68 6,14 MPa). O terço do conduto exerceu influência significativa sobre a resistência adesiva (p<0,0001), sendo os maiores valores obtidos no terço apical. As espessuras do filme de cimento foram estatisticamente diferentes nos grupos. Os maiores valores de espessura de cimento foram obtidos no G3 (248,78 μm), seguido de G2 (185,91 μm) e G1 (110,16 μm), sendo o último estatisticamente semelhante ao G4 (119,99 μm). Os resultados de G1(10,04 5,13 MPa) e G4 (8,89 + 5,18 MPa) foram estatisticamente semelhantes, indicando que a presença da Rodamina B não influencia significativamente na resistência de união. O tipo de falha predominante no G1 foi mista, no G2, adesiva entre pino e cimento, e no G3 e G4, adesiva entre cimento e dentina. O diâmetro da broca influenciou significativamente nos resultados de resistência de união ao teste de push-out. O ligeiro aumento na espessura do filme de cimento promoveu um aumento nos valores de resistência, quando comparado com filmes de cimento muito finos ou muito espessos.