936 resultados para Demand control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Anti-islanding protection is becoming increasingly important due to the rapid installation of distributed generation from renewable resources like wind, tidal and wave, solar PV, bio-fuels, as well as from other resources like diesel. Unintentional islanding presents a potential risk for damaging utility plants and equipment connected from the demand side, as well as to public and personnel in utility plants. This paper investigates automatic islanding detection. This is achieved by deploying a statistical process control approach for fault detection with the real-time data acquired through a wide area measurement system, which is based on Phasor Measurement Unit (PMU) technology. In particular, the principal component analysis (PCA) is used to project the data into principal component subspace and residual space, and two statistics are used to detect the occurrence of fault. Then a fault reconstruction method is used to identify the fault and its development over time. The proposed scheme has been used in a real system and the results have confirmed that the proposed method can correctly identify the fault and islanding site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The need for fast response demand side participation (DSP) has never been greater due to increased wind power penetration. White domestic goods suppliers are currently developing a `smart' chip for a range of domestic appliances (e.g. refrigeration units, tumble dryers and storage heaters) to support the home as a DSP unit in future power systems. This paper presents an aggregated population-based model of a single compressor fridge-freezer. Two scenarios (i.e. energy efficiency class and size) for valley filling and peak shaving are examined to quantify and value DSP savings in 2020. The analysis shows potential peak reductions of 40 MW to 55 MW are achievable in the Single wholesale Electricity Market of Ireland (i.e. the test system), and valley demand increases of up to 30 MW. The study also shows the importance of the control strategy start time and the staggering of the devices to obtain the desired filling or shaving effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The expectations of citizens from the Information Technologies (ITs) are increasing as the ITs have become integral part of our society, serving all kinds of activities whether professional, leisure, safety-critical applications or business. Hence, the limitations of the traditional network designs to provide innovative and enhanced services and applications motivated a consensus to integrate all services over packet switching infrastructures, using the Internet Protocol, so as to leverage flexible control and economical benefits in the Next Generation Networks (NGNs). However, the Internet is not capable of treating services differently while each service has its own requirements (e.g., Quality of Service - QoS). Therefore, the need for more evolved forms of communications has driven to radical changes of architectural and layering designs which demand appropriate solutions for service admission and network resources control. This Thesis addresses QoS and network control issues, aiming to improve overall control performance in current and future networks which classify services into classes. The Thesis is divided into three parts. In the first part, we propose two resource over-reservation algorithms, a Class-based bandwidth Over-Reservation (COR) and an Enhanced COR (ECOR). The over-reservation means reserving more bandwidth than a Class of Service (CoS) needs, so the QoS reservation signalling rate is reduced. COR and ECOR allow for dynamically defining over-reservation parameters for CoSs based on network interfaces resource conditions; they aim to reduce QoS signalling and related overhead without incurring CoS starvation or waste of bandwidth. ECOR differs from COR by allowing for optimizing control overhead minimization. Further, we propose a centralized control mechanism called Advanced Centralization Architecture (ACA), that uses a single state-full Control Decision Point (CDP) which maintains a good view of its underlying network topology and the related links resource statistics on real-time basis to control the overall network. It is very important to mention that, in this Thesis, we use multicast trees as the basis for session transport, not only for group communication purposes, but mainly to pin packets of a session mapped to a tree to follow the desired tree. Our simulation results prove a drastic reduction of QoS control signalling and the related overhead without QoS violation or waste of resources. Besides, we provide a generic-purpose analytical model to assess the impact of various parameters (e.g., link capacity, session dynamics, etc.) that generally challenge resource overprovisioning control. In the second part of this Thesis, we propose a decentralization control mechanism called Advanced Class-based resource OverpRovisioning (ACOR), that aims to achieve better scalability than the ACA approach. ACOR enables multiple CDPs, distributed at network edge, to cooperate and exchange appropriate control data (e.g., trees and bandwidth usage information) such that each CDP is able to maintain a good knowledge of the network topology and the related links resource statistics on real-time basis. From scalability perspective, ACOR cooperation is selective, meaning that control information is exchanged dynamically among only the CDPs which are concerned (correlated). Moreover, the synchronization is carried out through our proposed concept of Virtual Over-Provisioned Resource (VOPR), which is a share of over-reservations of each interface to each tree that uses the interface. Thus, each CDP can process several session requests over a tree without requiring synchronization between the correlated CDPs as long as the VOPR of the tree is not exhausted. Analytical and simulation results demonstrate that aggregate over-reservation control in decentralized scenarios keep low signalling without QoS violations or waste of resources. We also introduced a control signalling protocol called ACOR Protocol (ACOR-P) to support the centralization and decentralization designs in this Thesis. Further, we propose an Extended ACOR (E-ACOR) which aggregates the VOPR of all trees that originate at the same CDP, and more session requests can be processed without synchronization when compared with ACOR. In addition, E-ACOR introduces a mechanism to efficiently track network congestion information to prevent unnecessary synchronization during congestion time when VOPRs would exhaust upon every session request. The performance evaluation through analytical and simulation results proves the superiority of E-ACOR in minimizing overall control signalling overhead while keeping all advantages of ACOR, that is, without incurring QoS violations or waste of resources. The last part of this Thesis includes the Survivable ACOR (SACOR) proposal to support stable operations of the QoS and network control mechanisms in case of failures and recoveries (e.g., of links and nodes). The performance results show flexible survivability characterized by fast convergence time and differentiation of traffic re-routing under efficient resource utilization i.e. without wasting bandwidth. In summary, the QoS and architectural control mechanisms proposed in this Thesis provide efficient and scalable support for network control key sub-systems (e.g., QoS and resource control, traffic engineering, multicasting, etc.), and thus allow for optimizing network overall control performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fast increase in the energy’s price has brought a growing concern about the highly expensive task of transporting water. By creating an hydraulic model of the Water Supply System’s (WSS) network and predicting its behaviour, it is possible to take advantage of the energy’s tariffs, reducing the total cost on pumping activities. This thesis was developed, in association with a technology transfer project called the E-Pumping. It focuses on finding a flexible supervision and control strategy, adaptable to any existent Water Supply System (WSS), as well as forecasting the water demand on a time period chosen by the end user, so that the pumping actions could be planned to an optimum schedule, that minimizes the total operational cost. The OPC protocol, associated to a MySQL database were used to develop a flexible tool of supervision and control, due to their adaptability to function with equipments from various manufacturers, being another integrated modular part of the E-Pumping project. Furthermore, in this thesis, through the study and performance tests of several statistical models based on time series, specifically applied to this problem, a forecasting tool adaptable to any station, and whose model parameters are automatically refreshed at runtime, was developed and added to the project as another module. Both the aforementioned modules were later integrated with an Graphical User Interface (GUI) and installed in a pilot application at the ADDP’s network. The implementation of this software on WSSs across the country will reduce the water supply companies’ running costs, improving their market competition and, ultimately, lowering the water price to the end costumer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years the use of several new resources in power systems, such as distributed generation, demand response and more recently electric vehicles, has significantly increased. Power systems aim at lowering operational costs, requiring an adequate energy resources management. In this context, load consumption management plays an important role, being necessary to use optimization strategies to adjust the consumption to the supply profile. These optimization strategies can be integrated in demand response programs. The control of the energy consumption of an intelligent house has the objective of optimizing the load consumption. This paper presents a genetic algorithm approach to manage the consumption of a residential house making use of a SCADA system developed by the authors. Consumption management is done reducing or curtailing loads to keep the power consumption in, or below, a specified energy consumption limit. This limit is determined according to the consumer strategy and taking into account the renewable based micro generation, energy price, supplier solicitations, and consumers’ preferences. The proposed approach is compared with a mixed integer non-linear approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A supervisory control and data acquisition (SCADA) system is an integrated platform that incorporates several components and it has been applied in the field of power systems and several engineering applications to monitor, operate and control a lot of processes. In the future electrical networks, SCADA systems are essential for an intelligent management of resources like distributed generation and demand response, implemented in the smart grid context. This paper presents a SCADA system for a typical residential house. The application is implemented on MOVICON™11 software. The main objective is to manage the residential consumption, reducing or curtailing loads to keep the power consumption in or below a specified setpoint, imposed by the costumer and the generation availability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Environmental concerns and the shortage in the fossil fuel reserves have been potentiating the growth and globalization of distributed generation. Another resource that has been increasing its importance is the demand response, which is used to change consumers’ consumption profile, helping to reduce peak demand. Aiming to support small players’ participation in demand response events, the Curtailment Service Provider emerged. This player works as an aggregator for demand response events. The control of small and medium players which act in smart grid and micro grid environments is enhanced with a multi-agent system with artificial intelligence techniques – the MASGriP (Multi-Agent Smart Grid Platform). Using strategic behaviours in each player, this system simulates the profile of real players by using software agents. This paper shows the importance of modeling these behaviours for studying this type of scenarios. A case study with three examples shows the differences between each player and the best behaviour in order to achieve the higher profit in each situation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent changes of paradigm in power systems opened the opportunity to the active participation of new players. The small and medium players gain new opportunities while participating in demand response programs. This paper explores the optimal resources scheduling in two distinct levels. First, the network operator facing large wind power variations makes use of real time pricing to induce consumers to meet wind power variations. Then, at the consumer level, each load is managed according to the consumer preferences. The two-level resources schedule has been implemented in a real-time simulation platform, which uses hardware for consumer’ loads control. The illustrative example includes a situation of large lack of wind power and focuses on a consumer with 18 loads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Through this paper. we have attempted to model the demand for different classes of antibiotics used for respiratory infections in outpatient care in Switzerland using a spatial version of the linear approximate Almost Ideal Demand System (AIDS) model. This model takes spatial dependency into account by means of spatial lags of antibiotic budget shares. We control for the health status of patients and the potential harmful effects of antibiotic use in terms of bacterial resistance. Elasticities to socioeconomic determinants of consumption and own- and cross-price elasticities between different groups of antibiotic have also been computed in this paper. Significant cross-price elasticities are found between newer or more expensive generations and older or less expensive generations of antibiotics. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study the quality and process control factors during the production and storage of salted dried fish products. The study reveals that quantity of dry fish production in the state is decreasing and dry fish processing industry should be encouraged by central and state governments. The dry and wet salting may be carried out to a period of 4 to 8 hours respectively and time may depend on temperature, size, and concentration of medium. Demand is an unavoidable factor for sale of fish. The packed dry salted lots kept at room temperature are useful only for 20 days. The refrigerator- stored lots had more storage life and nutritional content are good up to 3 months. The cold storage stored dry salted lot had more storage life than the wet salted lot. The use of preservatives in salting is encouraged to reduce pH. The low temperature preservation maintains the nutritional value and quality for long period. It further encourages the labeling of nutritional value of dry fish as in tinned products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A high demand exists to increase the efficiency of present airport ground facilities and the co-ordination of traffic and services. The Traffic Office plays a crucial role in managing the airport. The main tasks of the Traffic Office is management of equipment, services, and ressources based on the flight schedule and resolving conflicts arising from deviations from the schedule. A new tool will support information exchange between Traffic Office and other facilities on the airport.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Urban air pollution and climate are closely connected due to shared generating processes (e.g., combustion) for emissions of the driving gases and aerosols. They are also connected because the atmospheric lifecycles of common air pollutants such as CO, NOx and VOCs, and of the climatically important methane gas (CH4) and sulfate aerosols, both involve the fast photochemistry of the hydroxyl free radical (OH). Thus policies designed to address air pollution may impact climate and vice versa. We present calculations using a model coupling economics, atmospheric chemistry, climate and ecosystems to illustrate some effects of air pollution policy alone on global warming. We consider caps on emissions of NOx, CO, volatile organic carbon, and SOx both individually and combined in two ways. These caps can lower ozone causing less warming, lower sulfate aerosols yielding more warming, lower OH and thus increase CH4 giving more warming, and finally, allow more carbon uptake by ecosystems leading to less warming. Overall, these effects significantly offset each other suggesting that air pollution policy has a relatively small net effect on the global mean surface temperature and sea level rise. However, our study does not account for the effects of air pollution policies on overall demand for fossil fuels and on the choice of fuels (coal, oil, gas), nor have we considered the effects of caps on black carbon or organic carbon aerosols on climate. These effects, if included, could lead to more substantial impacts of capping pollutant emissions on global temperature and sea level than concluded here. Caps on aerosols in general could also yield impacts on other important aspects of climate beyond those addressed here, such as the regional patterns of cloudiness and precipitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Distribution Network Operators (DNOs) role is becoming more difficult as electric vehicles and electric heating penetrate the network, increasing the demand. As a result it becomes harder for the distribution networks infrastructure to remain within its operating constraints. Energy storage is a potential alternative to conventional network reinforcement such as upgrading cables and transformers. The research presented here in this paper shows that due to the volatile nature of the LV network, the control approach used for energy storage has a significant impact on performance. This paper presents and compares control methodologies for energy storage where the objective is to get the greatest possible peak demand reduction across the day from a pre-specified storage device. The results presented show the benefits and detriments of specific types of control on a storage device connected to a single phase of an LV network, using aggregated demand profiles based on real smart meter data from individual homes. The research demonstrates an important relationship between how predictable an aggregation is and the best control methodology required to achieve the objective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main idea of this research to solve the problem of inventory management for the paper industry SPM PVT limited. The aim of this research was to find a methodology by which the inventory of raw material could be kept at minimum level by means of buffer stock level.The main objective then lies in finding the minimum level of buffer stock according to daily consumption of raw material, finding the Economic Order Quantity (EOQ) reorders point and how much order will be placed in a year to control the shortage of raw material.In this project, we discuss continuous review model (Deterministic EOQ models) that includes the probabilistic demand directly in the formulation. According to the formula, we see the reorder point and the order up to model. The problem was tackled mathematically as well as simulation modeling was used where mathematically tractable solution was not possible.The simulation modeling was done by Awesim software for developing the simulation network. This simulation network has the ability to predict the buffer stock level based on variable consumption of raw material and lead-time. The data collection for this simulation network is taken from the industrial engineering personnel and the departmental studies of the concerned factory. At the end, we find the optimum level of order quantity, reorder point and order days.