970 resultados para Cooking losses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the influence of the form of motor excitation on the performance of a small (< 1 kW) induction motor drive is studied. Two forms of excitation, namely sine waves generated by pulse width modulation and simple square wave are explored. Sine wave excitation gives lower motor losses but increases inverter losses. Conversely, square wave excitation increases motor losses but decreases inverter losses. Losses have been measured directly by calorimetric means or, in the case of the inverter, predicted by a Pspice model that has been verified by calorimetric methods. The work shows that overall, the use of square wave excitation leads to a more efficient drive. © 2004 The Institution of Electrical Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of experimental and simulation investigations of the breakdown of losses in a small inverter fed induction motor. Factors that are considered include the impact of skew, excitation voltage waveform shape and PWM switching frequency. Detailed finite element simulations of the motor performance are carried out for the various conditions, with simulation results compared to calorimetric test results. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

this paper quantifies effects of using three different pulse width modulation (PWM) schemes on the losses in the inverter and induction motor of a 1 kW drive. Direct measurements of losses have been made with a calorimeter. Results show that for the inverter, discontinuous PWM excitation reduces losses by up to 15% compared to sine and symmetrical space vector PWM methods. However, at a low modulation index the greater harmonic content with discontinuous PWM increased motor losses by nearly 20%. This study demonstrates the importance of careful choice of modulation scheme to achieve high overall drive efficiency. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of an investigation into the impact of pulse width modulation (PWM) switching schemes on power losses in induction motors and their inverter drives. The PWM schemes considered include sinusoidal PWM, spacevector PWM and discontinuous PWM. Both experimental results and simulated predictions are presented for fractional horsepower and small integral horsepower motors. Direct loss measurements have been carried out using a calorimetric test rig; detailed simulations of the skewed motors have been carried out using multi-slice time-stepped 2D FEA. The simulated and measured losses under the different modulation schemes are compared and discussed. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compact Fluorescent Lamps (CFL) incorporating electronic ballasts are widely used in lighting. In many cases the ability to dim the lamp is a requirement Dimming can be achieved by varying the voltage supplied to the inverter or by changing the switching frequency of the inverter. The effect of dimming by both approaches on the power losses in the inverter is studied in this work. The lamp and associated inverter has been modeled in PSPICE, using a behavioral model for the CFL. Predicted losses are in good agreement with experimental data obtained from calorimetry. The model was then used to determine the distribution of losses within the inverter, enabling a comparison of the effects of the two dimming methods to be made. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the report of a research study aimed at providing an understanding of the fishing communities and institutions about the water hyacinth problem and how it impacts on their activities. Its also provides strategies for sustainable control of the weed. The research reports are intended to disseminate the findings of the studies carried out under the Socio-economics Sub-component of LVEMP to a wide spectrum of users, including policy makers, stakeholders and researchers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study an inductor-less piezoelectric transformer (PT) based ballast for a 5 W CFL has been designed and simulated. The predictions of circuit currents and losses closely match experimentally measured values. The total simulated loss figure was confirmed against practically determined losses using a precision mini-calorimeter. Using simulation to disaggregate the total loss figure, it is seen that the PT makes the largest contribution to the total losses in such ballast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-temperature superconductors have created the opportunity for a step change in the technology of power applications. Racetrack superconducting coils made from YBCO coated conductors have been used in several engineering applications including SMES, rotor or stator windings of electric machines. AC loss is one of the most important factors that determine the design and performance of superconducting devices. In this paper, a numerical model is developed to calculate the AC losses in superconducting racetrack coils in different magnetic conditions. This paper first discusses the AC losses of the coils in self-field or external field only. It then goes to investigate the AC losses of the coils being exposed to AC ripple field and a DC background field. Finally, the AC losses of the coils carrying DC current and being exposed to AC field are calculated. These two scenarios correspond to using superconducting coils as the rotor field winding of an electric machine. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commercially available integrated compact fluorescent lamps (CFLs) use self-resonant ballasts on grounds of simplicity and cost. To understand how to improve ballast efficiency, it is necessary to quantify the losses. The losses occurring in these ballasts have been directly measured using a precision mini-calorimeter. In addition, a Pspice model has been used to simulate the performance of an 18 W integrated CFL. The lamp has been represented by a behavioural model and Jiles-Atherton equations were used to model the current transformer core. The total loss is in close agreement with measurements from the mini-calorimeter, confirming the accuracy of the model. The total loss was then disaggregated into component losses by simulation, showing that the output inductor is the primary source of loss, followed by the inverter switches. © 2011 The Institution of Engineering and Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prawn meat which was never in contact with ice or water prior to freezing was frozen at -30°C and was studied up to six months of storage at -23°C for thawing losses and cooked characteristics of the thawed material. Thawing loss was nil in unwashed samples after three days of storage and it gradually increased to 6.6% after 6 months compared to 6.0 and 18.2% in the washed samples during the same periods. It is inferred that the high thawing losses observed in commercial frozen prawn meat immediately after freezing may be mainly an after effect of the water imbibed during the pre-freezing stages. During frozen storage, the changes in texture observed by sensory methods on the cooked product were more in the washed sample indicating that the imbibed water or constituents washed out of the tissue play an important role in textural changes in prawn meat during frozen storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in the total as well as major individual carbonyls of oil sardine during steam cooking, oven drying, sun drying and freeze drying are presented. Carbonyls extracted with hexane were converted to their 2:4 dinitro phenyl hydrazone (DNPH) derivatives and were separated into major classes by column chromatography on celite/magnesia. Individual carbonyls were then identified by capillary gas chromatography of the DNPH derivatives. Dehydration and heating increase the carbonyl production from highly unsaturated fish lipids. The carbonyls produced react with other muscle constituents leading to complex changes. The influence of the mode of dehydration on these different aspects and their net effect on flavour are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the authors investigate the electromagnetic properties of stacks of high temperature superconductor (HTS) coated conductors with a particular focus on calculating the total transport AC loss. The cross-section of superconducting cables and coils is often modeled as a two-dimensional stack of coated conductors, and these stacks can be used to estimate the AC loss of a practical device. This paper uses a symmetric two dimensional (2D) finite element model based on the H formulation, and a detailed investigation into the effects of a magnetic substrate on the transport AC loss of a stack is presented. The number of coated conductors in each stack is varied from 1 to 150, and three types of substrate are compared: non-magnetic weakly magnetic and strongly magnetic. The non-magnetic substrate model is comparable with results from existing models for the limiting cases of a single tape (Norris) and an infinite stack (Clem). The presence of a magnetic substrate increases the total AC loss of the stack, due to an increased localized magnetic flux density, and the stronger the magnetic material, the further the flux penetrates into the stack overall. The AC loss is calculated for certain tapes within the stack, and the differences and similarities between the losses throughout the stack are explained using the magnetic flux penetration and current density distributions in those tapes. The ferromagnetic loss of the substrate itself is found to be negligible in most cases, except for small magnitudes of current. Applying these findings to practical applications, where AC transport current is involved, superconducting coils should be wound where possible using coated conductors with a non-magnetic substrate to reduce the total AC loss in the coil. © 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compact fluorescent lamps (CFLs) incorporating electronic ballasts are widely used in lighting. In many cases, the ability to dim the lamp is a requirement. Dimming can be achieved by varying the switching frequency of the inverter or by changing the voltage supplied to the inverter. The effect of dimming by both approaches on the power losses in the inverter is studied in this work. The lamp and associated inverter has been modeled in Pspice, using a behavioral model for the CFL. Predicted losses are in good agreement with experimental data obtained from calorimetry. After verification, the model was then used to determine the distribution of losses within the inverter, enabling a comparison of the effects of the two dimming methods to be made. © 2011 IEEE.