963 resultados para Conventional evaluation
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The hydrodynamic characterization and the performance evaluation of an aerobic three phase fluidized bed reactor in wastewater fish culture treatment are presented in this report. The objective of this study was to evaluate the organic matter, nitrogen and phosphorous removal efficiency in a physical and biological wastewater treatment system of an intensive Nile Tilapia laboratory production with recirculation. The treatment system comprised of a conventional sedimentation basin operated at a hydraulic detention time HDT of 2.94 h and an aerobic three phase airlift fluidized bed reactor AAFBR operated at an 11.9 min HDT. Granular activated carbon was used as support media with density of 1.64 g/cm(3) and effective size of 0.34 mm in an 80 g/L constant concentration. Mean removal efficiencies of BOD, COD, phosphorous, total ammonia nitrogen and total nitrogen were 47%, 77%, 38%, 27% and 24%, respectively. The evaluated system proved an effective alternative for water reuse in the recirculation system capable of maintaining water quality characteristics within the recommended values for fish farming and met the Brazilian standards for final effluent discharges with exception of phosphorous values. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The fig (Ficus carica L.), belonging to the Moraceas family, is one of the most important fruit crops, bringing Brazil to the condition of the tenth largest fig producer and exporter in the world. But the culture presents some problems with plant protection, and in Brazil, it is all implanted with an only cultivar, Roxo-de-Valinhos, which produces seedless fruit, not permitting the conventional improvement. In this sense, the genetic improvement by using mutagenic becomes a very important research line, that can greatly contribute to the culture development. Considering this, this study aimed to evaluate selections of fig originated from mutant plants formed by cuttings from buds irradiated with gamma ray and compare them with the main varieties of the culture in commercial plantation. By using plants originated from 5 traditional fig cultivars cuttings and 5 fig mutant selections (formed by cuttings from Roxo-de-Valinhos buds irradiated with gamma ray, in the dose of 30 Gy), spaced by 2.5 x 1.5 m. The experimental layout was a completely randomized block design, with 10 treatments, 3 repetitions and 5 plants per plot. The evaluations are made from the plants vegetative growth as well as the fruit characteristics. Through data analysis, it seems that there is variability between the mutant selections and with the traditional cultivars, and the treatment PI-189 was superior to the standard cultivar Roxo-de-Valinhos on great commercial characteristics importance, such as "number of fruit per plant", "average weight per fruit" and "productivity", having the same traits, showing itself with enormous potential for future studies.
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the application of PCR technique for the detection of BoHV-5 in routinely formalin-fixed, paraffin-embedded brain tissues in 20 naturally infected calves affected by fatal meningoencephalitis. Brains were divided into two halves, one kept fresh for virus isolation and PCR assay, targeting the glycoprotein C gene from BoHV-5 genome. The other half brain, corresponding to posterior cortex region, was submitted to formalin fixation and embedded into paraffin blocks for microscopic evaluation and total DNA isolation. Most of the slides showed severe multifocal non-supurative encephalitis with neuronal degeneration, neurophagia, and no acidophilic intranuclear inclusions could be found in neurons and glial. The 20 fresh samples were confirmed, by virus isolation and PCR assay, as having the BoHV-5 virus and, respective glicoprotein C sequence, while 15 of 20 formalin-fixed, paraffin-embedded samples were considered positive for the same analysis. The results revealed the first description of PCR efficiency, applied to formalin-fixed, paraffin-embedded brain collected from naturally infected calves, improving the detection of BoHV-5 from archival samples in South America. (c) 2007 Published by Elsevier B.V.
Resumo:
Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.
Resumo:
Background:It has been stated that mandibular overdentures are more satisfactory than conventional dentures, but problems relating to the use of retrospective ratings, lack of control group and sequential provision of treatment may compromise the findings.Objective:To establish a comparison between treatment with conventional complete dentures and implant-retained overdentures in elderly patients by conducting a literature review.Materials and methods:A search of English language peer-review literature was completed using Medline up to 2008 focusing on evidence-based research. Randomised clinical trials (RCTs) and longitudinal prospective studies were favoured in the review, using a general hierarchical classification. Articles that did not focus exclusively on the comparison of patient satisfaction between complete dentures and overdentures were excluded from further evaluation. The last search was conducted in February 2008. Key terms included quality of life, patient satisfaction, edentulism, complete denture and overdenture.Results:Among the 90 articles found in the initial search, 27 met the inclusion criteria. This included 18 RCTs and eight prospective and one cohort study. Most of the articles stated superiority of the mandibular implant-retained overdenture therapy over the conventional complete denture regarding patient satisfaction and quality of life.Conclusion:Even with implant treatment presenting higher patient satisfaction and improvement of quality of life, it was not possible to establish a direct comparison between the studies due to differences in adopted methodologies.
Resumo:
Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Nanostructures on implant surfaces have been shown to enhance osseointegration; however, commonly used evaluation techniques are probably not sufficiently sensitive to fully determine the effects of this process. This study aimed to observe the osseointegration properties of nanostructured calcium phosphate (CaP)-coated implants, by using a combination of three-dimensional imaging and conventional histology. Titanium implants were coated with stable CaP nanoparticles using an immersion technique followed by heat treatment. Uncoated implants were used as the control. After topographical and chemical characterizations, implants were inserted into the rabbit femur. After 2 and 4 weeks, the samples were retrieved for micro-computed tomography and histomorphometric evaluation. Scanning electron microscopy evaluation indicated that the implant surface was modified at the nanoscale by CaP to obtain surface textured with rod-shaped structures. Relative to the control, the bone-to-implant contact for the CaP-coated implant was significantly higher at 4 weeks after the implant surgery. Further, corresponding 3-D images showed active bone formation surrounding the implant. 3-D quantification and 2-D histology demonstrated statistical correlation; moreover, 3-D quantification indicated a statistical decrease in bone density in the non-coated control implant group between 2 and 4 weeks after the surgery. The application of 3-D evaluation further clarified the temporal characteristics and biological reaction of implants in bone. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: The aim of the present study was to evaluate histometric changes around dental implants inserted at different levels in relation to the crestal bone, under different loading conditions.Material and methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at the crestal bone level), Minus 1 (1 mm below the crestal bone) or Minus 2 group (2 mm below the crestal bone). Each hemimandible was submitted to a loading protocol: conventional or immediate restoration. After 90 days, the animals were killed. Specimens were processed, and measurements were performed concerning the length of soft and hard peri-implant tissues. Data were analyzed using ANOVA and Student's t test (alpha=5%).Results: Among conventionally restored sites, the distance from the most coronal position of soft tissue margin (PSTM) and first bone-implant contact (fBIC) was greater for Minus 2 than for Bone Level and Minus 1 sites (P=0.03), but significant differences were not observed among immediately restored sites. Differences among groups were not observed concerning the PSTM, and the distance from the implant-abutment junction to fBIC. Greater amounts of lateral bone loss were observed for conventionally than for immediately restored sites (P=0.006).Conclusions: These findings suggest that the apical positioning of the top of the implant may not jeopardize the position of soft peri-implant tissues, and that immediate restoration can be beneficial to minimize lateral bone loss. Further studies are suggested to evaluate the clinical significance of these results in longer healing periods.
Resumo:
Objective. The aim of this study was to detect the development of experimentally induced periapical lesions using conventional radiography and computed tomography.Study design. The root canals of dogs' teeth were exposed to the oral environment for 7 days for contamination and then sealed for 7 days (GI), 15 days (GII), 30 days (GIII), and 60 days (GIV). Immediately after each experimental period, radiographs and tomograms were taken in order to detect the occurrence of periapical bone resorption. The periapical radiographs were digitized and areas of bone resorption were measured using the VIXWIN 2000 software. Scores were assigned to the tomograms based on the progression of periapical bone resorption. The specimens were evaluated by calibrated examiners who were blinded to the groups. The radiographic results were analyzed by ANOVA and Tukey's test (P <.05) and the tomographic results were analyzed by Kruskal-Wallis and Dunn's tests (P <.05).Results. The radiographic evaluation did not reveal periapical lesions at the 7-day control. Lesions were radiographically visible at 15 and 30 days (47.4% and 77.8% of the cases, respectively) and presented similar dimensions (P <.05). At 60 days, lesions were detected in all specimens, presenting larger dimensions than those of the earlier evaluation periods (P <.05). The tomographic evaluation detected lesions at 7 and 15 days (32.5% and 83.3% of the cases, respectively). Lesions were detected in all specimens at the 30- and 60-day periods, when the greatest values of bone resorption were observed (P <.05).Conclusions. Tomography was able to detect periapical lesion development in its initial stages, even when the lesions were undetectable radiographically.