994 resultados para Conventional coronary stent


Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIM: To compare the long-term relative efficacy and safety of SES and PES in patients undergoing percutaneous coronary intervention (PCI) for unprotected left main coronary artery (ULMCA) disease and to evaluate the role of lesion location and stenting technique in determining outcomes. METHODS AND RESULTS: From April 2002 to April 2004, 288 consecutive patients who underwent elective PCI with DES implantation for de novo lesions on ULMCA have been retrospectively selected and analyzed in seven European and US tertiary care centers. All patients had a minimum follow-up of 3 years. SES was used in 152 patients while 136 received PES. Isolated ostial-shaft disease was present in 27% of patients. Distal LM disease (73%) was treated with single and double stent approach in 29.5% and 43.4% of patients respectively. After 3 years, rates of survival free from any of the events investigated, were independent from lesion location and stenting approach and did not differ significantly between SES and PES groups. Freedom from MACE (SES vs. PES) was 76.3% vs. 83.1% in the ostial/shaft group, 80.3% vs. 72.8% in the distal-single stent group and 67.1% vs. 66.2% in the distal-double stent group. Definite stent thrombosis occurred only in 1(0.3%) patient at 439 days. CONCLUSIONS: In elective patients who underwent PCI for de novo lesions in the ostium, shaft or distal ULMCA, long-term clinical outcomes with SES and PES use were similar independently of lesion location and stenting technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to investigate the long-term safety and efficacy of percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation for unprotected left main coronary artery (ULMCA) disease. BACKGROUND: Long-term clinical outcomes after DES implantation for ULMCA disease have not yet been ascertained. METHODS: From April 2002 to April 2004, 358 consecutive patients who underwent PCI with DES implantation for de novo lesions on ULMCA were retrospectively selected and analyzed in 7 European and U.S. tertiary care centers. No patients were excluded from the analysis, and all patients had a minimum follow-up of 3 years. RESULTS: Technical success rate was 100%. Procedural success rate was 89.6%. After 3 years, major adverse cardiovascular events (MACE)-free survival in the whole population was 73.5%. According to the Academic Research Consortium definitions, cardiac death occurred in 9.2% of patients, and reinfarction, target lesion revascularization (TLR), and target vessel revascularization (TVR) occurred in 8.6%, 5.8%, and 14.2% of patients, respectively. Definite stent thrombosis occurred in 2 patients (specifically at 0 and 439 days). In elective patients, the 3-year MACE-free survival was 74.2%, with mortality, reinfarction, TLR, and TVR rates of 6.2%, 8.3%, 6.6%, and 16%, respectively. In the emergent group the 3-year MACE-free survival was 68.2%, with mortality, reinfarction, TLR, and TVR rates of 21.4%, 10%, 2.8%, and 7.1%, respectively. CONCLUSIONS: Routine DES implantation in ULMCA disease seems encouraging, with favorable long-term clinical results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING: Biosensors Europe SA, Switzerland.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Rotational atherectomy has been regaining interest over the last couple of years after it almost has disappeared from most interventional catheterization laboratories for several years due to failure to prove its original concept of improving long term results of percutaneous coronary interventions (PCI) as was repeatedly shown in studies in the 1990s. Its revival coupled the introduction of drug-eluting stents (DES); these devices have led to treating much more complex lesions and high-risk patients by PCI. However, real-world experience suggested that off-label use of DES is associated with a higher rate of early and late stent thrombosis. Therefore, more attention is now being paid to the initial implantation technique of DES including aggressive lesion preparation to facilitate stent delivery and expansion. The limited studies with rot-ablation and DES showed promising results with no long term safety concerns. In these studies, a subtle observation was made suggesting that rot-ablation prior to DES implantation in such lesions may have an add-on effect on long term outcome compared to DES alone. An ongoing multicenter study is investigating such effect among complex calcified coronary lesions. Even if this additive benefit does not prove true, rot-ablation remains an efficient tool for preparing certain lesions to facilitate effective and safe DES implantation. Therefore, interventional training programs should focus on this difficult technique to bridge the gap of experience which resulted from neglecting it for several years. In this regard, dedicated courses at experienced sites as well as medical simulation may be appropriate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIMS: Diabetes mellitus (DM) plays an important role in the development of coronary artery disease. Although previous studies have associated drug-eluting stent (DES) implantation in diabetic patients with favourable clinical and angiographic outcomes, the very long-term efficacy of these devices in diabetic patients undergoing PCI for significant unprotected left main coronary artery (ULMCA) disease has not been established yet. METHODS AND RESULTS: Consecutive diabetic patients (n=100), who underwent elective PCI with DES for de novo lesions in an ULMCA between April 2002 and April 2004 in seven tertiary health care centres, were identified retrospectively and analysed. Consecutive non-diabetic patients (n=193), who underwent elective DES implantation for unprotected ULMCA disease, were selected as a control group. All patients were followed for at least 36 months. At 3-years follow-up, freedom from cardiac death ; myocardial infarction (CDMI), target lesion revascularisation (TLR) and target vessel revascularisation (TVR) did not differ significantly between groups. The adjusted freedom from major adverse cardiac events (MACE, defined as the occurrence of CD, MI or TVR) was 63.4% in the DM group and 77.6% in the controls (p<0.001). When divided into IDDM and NIDDM sub-groups, insulin-dependent DM (IDDM) but not non IDDM (NIDDM) patients had significantly lower freedom from CDMI, TLR, TVR and MACE compared to controls. CONCLUSIONS: These results suggest that major improvements in DES technology and pharmacotherapy are still required to improve clinical outcome and that the decision to perform percutaneous revascularisation in this subset of patients should be taken cautiously and on a case by case basis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims: Angiographic ectasias and aneurysms in stented segments have been associated with late stent thrombosis. Using optical coherence tomography (OCT), some stented segments show coronary evaginations reminiscent of ectasias. The purpose of this study was to explore, using computational fluid-dynamic (CFD) simulations, whether OCT-detected coronary evaginations can induce local changes in blood flow. Methods and results: OCT-detected evaginations are defined as outward bulges in the luminal vessel contour between struts, with the depth of the bulge exceeding the actual strut thickness. Evaginations can be characterised cross ectionally by depth and along the stented segment by total length. Assuming an ellipsoid shape, we modelled 3-D evaginations with different sizes by varying the depth from 0.2-1.0 mm, and the length from 1-9 mm. For the flow simulation we used average flow velocity data from non-diseased coronary arteries. The change in flow with varying evagination sizes was assessed using a particle tracing test where the particle transit time within the segment with evagination was compared with that of a control vessel. The presence of the evagination caused a delayed particle transit time which increased with the evagination size. The change in flow consisted locally of recirculation within the evagination, as well as flow deceleration due to a larger lumen - seen as a deflection of flow towards the evagination. Conclusions: CFD simulation of 3-D evaginations and blood flow suggests that evaginations affect flow locally, with a flow disturbance that increases with increasing evagination size.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE We investigated clinical outcomes after treatment of coronary bifurcation lesions with second generation drug eluting stents (DES). DESIGN Post hoc analysis of a randomised, multicentre, non-inferiority trial. SETTING Multicentre study. PATIENTS All comers study with minimal exclusion criteria. INTERVENTIONS Patients were treated with either zotarolimus or everolimus eluting stents. The patient population was divided according to treatment of bifurcation or non-bifurcation lesions and clinical outcomes were compared between groups. MAIN OUTCOMES MEASURES Clinical outcomes within 2-year follow-up. RESULTS A total of 2265 patients were included in the present analysis. Two-year follow-up data were available in 2223 patients: 1838 patients in the non-bifurcation group and 385 patients in the bifurcation group. At 2-year follow-up the bifurcation and the non-bifurcation lesion groups showed no significant differences in terms of cardiac death (2.3 vs 2.1, p=0.273), target lesion failure (9.7% vs 13.8%, p=0.255), major adverse cardiac events (11.5% vs 15.1%, p=0.305), target lesion revascularisation (4.7% vs 6.0%, p=0.569), and definite or probable stent thrombosis (1.6% vs 1.8%, p=0.419). CONCLUSIONS The use of second generation DES for the treatment of coronary bifurcation lesions was associated with similar long term mortality and clinical outcomes compared with non-bifurcation lesions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND We aimed to describe the effects of ticagrelor versus clopidogrel on stent thrombosis in the Platelet Inhibition and Patient Outcomes (PLATO) trial. METHODS AND RESULTS Of 18 624 patients hospitalized for acute coronary syndromes, 11 289 (61%) had at least 1 intracoronary stent. Ticagrelor reduced stent thrombosis compared with clopidogrel across all definitions: definite, 1.37% (n=71) versus 1.93% (n=105; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.50-0.90; P=0.0091); definite or probable, 2.21% (n=118) versus 2.87% (n=157; HR, 0.75; 95% CI, 0.59-0.95; P=0.017); and definite, probable, and possible, 2.94% (n=154) versus 3.77 (n=201; HR, 0.77; 95% CI, 0.62-0.95). The reduction in definite stent thrombosis was consistent regardless of acute coronary syndrome type, presence of diabetes mellitus, stent type (drug-eluting or bare metal stent), CYP2C19 genetic status, loading dose of aspirin, dose of clopidogrel before randomization, and use of glycoprotein IIb/IIIa inhibitors at randomization. The reduction in stent thrombosis with ticagrelor was numerically greater for late (>30 days; HR, 0.48; 95% CI, 0.24-0.96) and subacute (4 hours-30 days; HR, 0.60; 95% CI, 0.39-0.93) compared with acute (<24 hours; HR, 0.94; 95% CI, 0.43-2.05) stent thrombosis or for patients compliant to therapy (ie, taking blinded study treatment ≥80% of the time) compared with less compliant patients. Randomization to ticagrelor was a strong independent inverse predictor of definite stent thrombosis (HR, 0.65; 95% CI, 0.48-0.88). CONCLUSION Ticagrelor compared with clopidogrel reduces the incidence of stent thrombosis in patients with acute coronary syndromes, with consistent benefit across a broad range of patient, stent, and treatment characteristics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES This study sought to determine the effect of rotational atherectomy (RA) on drug-eluting stent (DES) effectiveness. BACKGROUND DES are frequently used in complex lesions, including calcified stenoses, which may challenge DES delivery, expansion, and effectiveness. RA can adequately modify calcified plaques and facilitate stent delivery and expansion. Its impact on DES effectiveness is widely unknown. METHODS The ROTAXUS (Rotational Atherectomy Prior to TAXUS Stent Treatment for Complex Native Coronary Artery Disease) study randomly assigned 240 patients with complex calcified native coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120, standard therapy group). Stenting was performed using a polymer-based slow-release paclitaxel-eluting stent. The primary endpoint was in-stent late lumen loss at 9 months. Secondary endpoints included angiographic and strategy success, binary restenosis, definite stent thrombosis, and major adverse cardiac events at 9 months. RESULTS Despite similar baseline characteristics, significantly more patients in the standard therapy group were crossed over (12.5% vs. 4.2%, p = 0.02), resulting in higher strategy success in the rotablation group (92.5% vs. 83.3%, p = 0.03). At 9 months, in-stent late lumen loss was higher in the rotablation group (0.44 ± 0.58 vs. 0.31 ± 0.52, p = 0.04), despite an initially higher acute lumen gain (1.56 ± 0.43 vs. 1.44 ± 0.49 mm, p = 0.01). In-stent binary restenosis (11.4% vs. 10.6%, p = 0.71), target lesion revascularization (11.7% vs. 12.5%, p = 0.84), definite stent thrombosis (0.8% vs. 0%, p = 1.0), and major adverse cardiac events (24.2% vs. 28.3%, p = 0.46) were similar in both groups. CONCLUSIONS Routine lesion preparation using RA did not reduce late lumen loss of DES at 9 months. Balloon dilation with only provisional rotablation remains the default strategy for complex calcified lesions before DES implantation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and results: Patients were divided into three groups: chronic TO (CTO; n=256), non-chronic TO (n=292), and no occlusion (n=2,941). Clinical and safety outcomes assessed through two years included target lesion failure (TLF: cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1% in the group with no occlusion, p=0.027). There were 10 late and six very late stent thrombosis events. Conclusions: Apart from a higher rate of stent thrombosis in patients with TO, patients with totally occluded coronary arteries who receive revascularisation with an R-ZES have clinical outcomes comparable to those who receive a similar stent in non-occluded lesions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims: The reported rate of stent thrombosis (ST) after drug-eluting stent (DES) implantation varies among registries. To investigate differences in baseline characteristics and clinical outcome in European and Japanese all-comers registries, we performed a pooled analysis of patient-level data. Methods and results: The j-Cypher registry (JC) is a multicentre observational study conducted in Japan, including 12,824 patients undergoing SES implantation. From the Bern-Rotterdam registry (BR) enrolled at two academic hospitals in Switzerland and the Netherlands, 3,823 patients with SES were included in the current analysis. Patients in BR were younger, more frequently smokers and presented more frequently with ST-elevation myocardial infarction (MI). Conversely, JC patients more frequently had diabetes and hypertension. At five years, the definite ST rate was significantly lower in JC than BR (JC 1.6% vs. BR 3.3%, p<0.001), while the unadjusted mortality tended to be lower in BR than in JC (BR 13.2% vs. JC 14.4%, log-rank p=0.052). After adjustment, the j-Cypher registry was associated with a significantly lower risk of all-cause mortality (HR 0.56, 95% CI: 0.49-0.64) as well as definite stent thrombosis (HR 0.46, 95% CI: 0.35-0.61). Conclusions: The baseline characteristics of the two large registries were different. After statistical adjustment, JC was associated with lower mortality and ST.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES This study aimed to update the Logistic Clinical SYNTAX score to predict 3-year survival after percutaneous coronary intervention (PCI) and compare the performance with the SYNTAX score alone. BACKGROUND The SYNTAX score is a well-established angiographic tool to predict long-term outcomes after PCI. The Logistic Clinical SYNTAX score, developed by combining clinical variables with the anatomic SYNTAX score, has been shown to perform better than the SYNTAX score alone in predicting 1-year outcomes after PCI. However, the ability of this score to predict long-term survival is unknown. METHODS Patient-level data (N = 6,304, 399 deaths within 3 years) from 7 contemporary PCI trials were analyzed. We revised the overall risk and the predictor effects in the core model (SYNTAX score, age, creatinine clearance, and left ventricular ejection fraction) using Cox regression analysis to predict mortality at 3 years. We also updated the extended model by combining the core model with additional independent predictors of 3-year mortality (i.e., diabetes mellitus, peripheral vascular disease, and body mass index). RESULTS The revised Logistic Clinical SYNTAX models showed better discriminative ability than the anatomic SYNTAX score for the prediction of 3-year mortality after PCI (c-index: SYNTAX score, 0.61; core model, 0.71; and extended model, 0.73 in a cross-validation procedure). The extended model in particular performed better in differentiating low- and intermediate-risk groups. CONCLUSIONS Risk scores combining clinical characteristics with the anatomic SYNTAX score substantially better predict 3-year mortality than the SYNTAX score alone and should be used for long-term risk stratification of patients undergoing PCI.