962 resultados para Continuous glucose monitoring


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: type 2 diabetes mellitus includes changes in lifestyle in its etiology of prevention, but the evidence is clear —even when people know what to do and what they want to do, they simply do not adopt adherence behaviors. Structured education will allow improving not only metabolic control, but also the adjustment process to a new situation of disease, as well as to develop the patient’s skills in order to make him the key manager of his illness. Objectives: To determine patients’ adherence to prescribed therapeutic regimens. Material and methods: Quantitative, cross-sectional, non-experimental, descriptive, correlational study, with a sample of 102 people with type 2 diabetes, aged between 40 and 85 years old, mostly male (51.96%). The evaluation protocol included social-demographic and clinical questionnaire, Diabetes Self-care Scale and a questionnaire on Diabetes’ knowledge. We also used HbA1c in order to directly assess adherence. Results: It appears that there is no statistically signiicant correlation between socio-demographic variables such as gender and age and adherence. Variables, such as blood glucose monitoring, speciic diet compliance and knowledge, reveal a statistically signiicant effect on adherence (P < .05). Conclusion: The evidence is clear on the urgent need to recognize the importance of measuring patient adherence to a diabetes treatment plan for the maintenance of glycaemic control. We suggest the reinforcement of educational programs in people with type 2 diabetes so as to improve adherence to self-care.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A comprehensive user model, built by monitoring a user's current use of applications, can be an excellent starting point for building adaptive user-centred applications. The BaranC framework monitors all user interaction with a digital device (e.g. smartphone), and also collects all available context data (such as from sensors in the digital device itself, in a smart watch, or in smart appliances) in order to build a full model of user application behaviour. The model built from the collected data, called the UDI (User Digital Imprint), is further augmented by analysis services, for example, a service to produce activity profiles from smartphone sensor data. The enhanced UDI model can then be the basis for building an appropriate adaptive application that is user-centred as it is based on an individual user model. As BaranC supports continuous user monitoring, an application can be dynamically adaptive in real-time to the current context (e.g. time, location or activity). Furthermore, since BaranC is continuously augmenting the user model with more monitored data, over time the user model changes, and the adaptive application can adapt gradually over time to changing user behaviour patterns. BaranC has been implemented as a service-oriented framework where the collection of data for the UDI and all sharing of the UDI data are kept strictly under the user's control. In addition, being service-oriented allows (with the user's permission) its monitoring and analysis services to be easily used by 3rd parties in order to provide 3rd party adaptive assistant services. An example 3rd party service demonstrator, built on top of BaranC, proactively assists a user by dynamic predication, based on the current context, what apps and contacts the user is likely to need. BaranC introduces an innovative user-controlled unified service model of monitoring and use of personal digital activity data in order to provide adaptive user-centred applications. This aims to improve on the current situation where the diversity of adaptive applications results in a proliferation of applications monitoring and using personal data, resulting in a lack of clarity, a dispersal of data, and a diminution of user control.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This article reports, in a systemized and analytical way, the experience of an Outreach Program in the period between 2010 and 2011. The study focused on health education interventions as strategies to improve the adherence of individuals with insulin- dependent diabetes mellitus (IDDM), clients of a blood glucose self-Monitoring program. In addition, we intended to contribute to the reorganization of the program's working processes in the unit. Health education strategies were used in both educational groups and home visits, thus permitting the provision of care that was more individualized. Data regarding the clients were organized on a spreadsheet and in files for the Family Health teams, which made it easier to identify the patients, including those who were absent, helping to decentralize the care. By using health education strategies, we intended to contribute to a more comprehensive and emancipatory care of the clients, aimed at a continuous reflection of the workers regarding their practices.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The uptake of ascorbate by neuroblastoma cells using a ruthenium oxide hexacyanoferrate (RuOHCF)-modified carbon fiber disc (CFD) microelectrode (r = 14.5 mu m) was investigated. By use of the proposed electrochemical sensor the amperometric determination of ascorbate was performed at 0.0 V in minimum essential medium (MEM, pH = 7.2) with a limit of detection of 25 mu mol L(-1). Under the optimum experimental conditions, no interference from MEM constituents and reduced glutathione (used to prevent the oxidation of ascorbate during the experiments) was noticed. The stability of the RuOHCF-modified electrode response was studied by measuring the sensitivity over an extended period of time (120 h), a decrease of around 10% being noticed at the end of the experiment. The rate of ascorbate uptake by control human neuroblastoma SH-SY5Y cells, and cells transfected with wild-type Cu,Zn-superoxide dismutase (SOD WT) or with a mutant typical of familial amyotrophic lateral sclerosis (SOD G93A), was in agreement with the level of oxidative stress in these cells. The usefulness of the RuOHCF-modified microelectrode for in vivo monitoring of ascorbate inside neuroblastoma cells was also demonstrated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To test the effect of liquid feeds on the responses to splanchnic ischaemia of a continuous rapid response PCO2 sensor inserted in the jejunum. Design: Prospective experimental animal study in a university research laboratory. Subjects: Adult male Wistar rats. Interventions: Adult male Wistar rats (285-425 g) were anaethetised with sodium pentobarbitone 60 mg/ kg i.p. and ventilated with 100 % oxygen and isoflurane via tracheostomy to a PaCO2 of 30-40 mmHg. A sensor was inserted into the mid-jejunum to record PCO2 every second. Distal aortic pressure was transduced. Four control rats received no feeds whilst in another four rats liquid feed was infused into the proximal jejunum at 3 ml/h. In each rat five episodes of splanchnic ischaemia were induced by 2-min elevations of an aortic sling to a mean distal aortic pressure of 30 mmHg. Measurements and main results: PCO2 elevations were always detectable, usually less than a minute from the onset of splanchnic ischaemia in both fed and unfed rats, with no difference in mean times to detectable response. In the fed rats there was a small but significant increase in the time to peak sensor response (196 +/- 16 vs. 180 +/- 12 s) and a trend towards an elevated mean baseline luminal PCO2 (67 +/- 9 vs. 55 +/- 4 mmHg). Conclusions: Brief episodes of splanchnic ischaemia were tracked successfully by a rapid response jejunal continuous PCO2 sensor during the infusion of a proprietary liquid feed preparation despite minor changes in PCO2 response characteristics and a possible elevation in baseline luminal PCO2.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The assessment of concrete mechanical properties during construction of concrete structures is of paramount importance for many intrinsic operations. However many of the available non-destructive methods for mechanical properties have limitations for use in construction sites. One of such methodologies is EMM-ARM, which is a variant of classic resonant frequency methods. This paper aims to demonstrate the efforts towards in-situ applicability of EMMARM, as to provide real-time information about concrete mechanical properties such as E-modulus and compressive strength. To achieve the aforementioned objective, a set of adaptations to the method have been successfully implemented and tested: (i) the reduction of the beam span; (ii) the use of a different mould material and (iii) a new support system for the beams. Based on these adaptations, a reusable mould was designed to enable easier systematic use of EMMARM. A pilot test was successfully performed under in-situ conditions during a bridge construction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The experimental evaluation of viscoelastic properties of concrete is traditionally made upon creep tests that consist in the application of sustained loads either in compression or in tension. This kind of testing demands for specially devised rigs and requires careful monitoring of the evolution of strains, whereas assuring proper load constancy. The characterization of creep behaviour at early ages offers additional challenges due to the strong variations in viscoelastic behaviour of concrete during such stages, demanding for several testing ages to be assessed. The present research work aims to assist in reducing efforts for continuous assessment of viscoelastic properties of concrete at early ages, by application of a dynamic testing technique inspired in methodologies used in polymer science: Dynamic Mechanical Analyses. This paper briefly explains the principles of the proposed methodology and exhibits the first results obtained in a pilot application. The results are promising enough to encourage further developments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: In critically ill patients, fractional hepatic de novo lipogenesis increases in proportion to carbohydrate administration during isoenergetic nutrition. In this study, we sought to determine whether this increase may be the consequence of continuous enteral nutrition and bed rest. We, therefore, measured fractional hepatic de novo lipogenesis in a group of 12 healthy subjects during near-continuous oral feeding (hourly isoenergetic meals with a liquid formula containing 55% carbohydrate). In eight subjects, near-continuous enteral nutrition and bed rest were applied over a 10 h period. In the other four subjects, it was extended to 34 h. Fractional hepatic de novo lipogenesis was measured by infusing(13) C-labeled acetate and monitoring VLDL-(13)C palmitate enrichment with mass isotopomer distribution analysis. Fractional hepatic de novo lipogenesis was 3.2% (range 1.5-7.5%) in the eight subjects after 10 h of near continuous nutrition and 1.6% (range 1.3-2.0%) in the four subjects after 34 h of near-continuous nutrition and bed rest. This indicates that continuous nutrition and physical inactivity do not increase hepatic de novo lipogenesis. Fractional hepatic de novo lipogenesis previously reported in critically ill patients under similar nutritional conditions (9.3%) (range 5.3-15.8%) was markedly higher than in healthy subjects (P&lt;0.001). These data from healthy subjects indicate that fractional hepatic de novo lipogenesis is increased in critically ill patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Near infrared spectroscopy (NIRS) is a non-invasive method of estimating the haemoglobin concentration changes in certain tissues. It is frequently used to monitor oxygenation of the brain in neonates. At present it is not clear whether near infrared spectroscopy of other organs (e.g. the liver as a corresponding site in the splanchnic region, which reacts very sensitively to haemodynamic instability) provides reliable values on their tissue oxygenation. The aim of the study was to test near infrared spectroscopy by measuring known physiologic changes in tissue oxygenation of the liver in newborn infants during and after feeding via a naso-gastric tube. The test-retest variability of such measurements was also determined. On 28 occasions in 25 infants we measured the tissue oxygenation index (TOI) of the liver and the brain continuously before, during and 30 minutes after feeding via a gastric tube. Simultaneously we measured arterial oxygen saturation (SaO2), heart rate (HR) and mean arterial blood pressure (MAP). In 10 other newborn infants we performed a test-retest analysis of the liver tissue oxygenation index to estimate the variability in repeated intra-individual measurements. The tissue oxygenation index of the liver increased significantly from 56.7 +/- 7.5% before to 60.3 +/- 5.6% after feeding (p < 0.005), and remained unchanged for the next 30 minutes. The tissue oxygenation index of the brain (62.1 +/- 9.7%), SaO2 (94.4 +/- 7.1%), heart rate (145 +/- 17.3 min-1) and mean arterial blood pressure (52.8 +/- 10.2 mm Hg) did not change significantly. The test-retest variability for intra-individual measurements was 2.7 +/- 2.1%. After bolus feeding the tissue oxygenation index of the liver increased as expected. This indicates that near infrared spectroscopy is suitable for monitoring changes in tissue oxygenation of the liver in newborn infants.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECT: Cerebrovascular pressure reactivity is the ability of cerebral vessels to respond to changes in transmural pressure. A cerebrovascular pressure reactivity index (PRx) can be determined as the moving correlation coefficient between mean intracranial pressure (ICP) and mean arterial blood pressure. METHODS: The authors analyzed a database consisting of 398 patients with head injuries who underwent continuous monitoring of cerebrovascular pressure reactivity. In 298 patients, the PRx was compared with a transcranial Doppler ultrasonography assessment of cerebrovascular autoregulation (the mean index [Mx]), in 17 patients with the PET-assessed static rate of autoregulation, and in 22 patients with the cerebral metabolic rate for O(2). Patient outcome was assessed 6 months after injury. RESULTS: There was a positive and significant association between the PRx and Mx (R(2) = 0.36, p < 0.001) and with the static rate of autoregulation (R(2) = 0.31, p = 0.02). A PRx > 0.35 was associated with a high mortality rate (> 50%). The PRx showed significant deterioration in refractory intracranial hypertension, was correlated with outcome, and was able to differentiate patients with good outcome, moderate disability, severe disability, and death. The graph of PRx compared with cerebral perfusion pressure (CPP) indicated a U-shaped curve, suggesting that too low and too high CPP was associated with a disturbance in pressure reactivity. Such an optimal CPP was confirmed in individual cases and a greater difference between current and optimal CPP was associated with worse outcome (for patients who, on average, were treated below optimal CPP [R(2) = 0.53, p < 0.001] and for patients whose mean CPP was above optimal CPP [R(2) = -0.40, p < 0.05]). Following decompressive craniectomy, pressure reactivity initially worsened (median -0.03 [interquartile range -0.13 to 0.06] to 0.14 [interquartile range 0.12-0.22]; p < 0.01) and improved in the later postoperative course. After therapeutic hypothermia, in 17 (70.8%) of 24 patients in whom rewarming exceeded the brain temperature threshold of 37 degrees C, ICP remained stable, but the average PRx increased to 0.32 (p < 0.0001), indicating significant derangement in cerebrovascular reactivity. CONCLUSIONS: The PRx is a secondary index derived from changes in ICP and arterial blood pressure and can be used as a surrogate marker of cerebrovascular impairment. In view of an autoregulation-guided CPP therapy, a continuous determination of a PRx is feasible, but its value has to be evaluated in a prospective controlled trial.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The DRG classification provides a useful tool for the evaluation of hospital care. Indicators such as readmissions and mortality rates adjusted for the hospital Casemix could be adopted in Switzerland at the price of minor additions to the hospital discharge record. The additional information required to build patients histories and to identify the deaths occurring after hospital discharge is detailed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The goal of this work was to move structural health monitoring (SHM) one step closer to being ready for mainstream use by the Iowa Department of Transportation (DOT) Office of Bridges and Structures. To meet this goal, the objective of this project was to implement a pilot multi-sensor continuous monitoring system on the Iowa Falls Arch Bridge such that autonomous data analysis, storage, and retrieval can be demonstrated. The challenge with this work was to develop the open channels for communication, coordination, and cooperation of various Iowa DOT offices that could make use of the data. In a way, the end product was to be something akin to a control system that would allow for real-time evaluation of the operational condition of a monitored bridge. Development and finalization of general hardware and software components for a bridge SHM system were investigated and completed. This development and finalization was framed around the demonstration installation on the Iowa Falls Arch Bridge. The hardware system focused on using off-the-shelf sensors that could be read in either “fast” or “slow” modes depending on the desired monitoring metric. As hoped, the installed system operated with very few problems. In terms of communications—in part due to the anticipated installation on the I-74 bridge over the Mississippi River—a hardline digital subscriber line (DSL) internet connection and grid power were used. During operation, this system would transmit data to a central server location where the data would be processed and then archived for future retrieval and use. The pilot monitoring system was developed for general performance evaluation purposes (construction, structural, environmental, etc.) such that it could be easily adapted to the Iowa DOT’s bridges and other monitoring needs. The system was developed allowing easy access to near real-time data in a format usable to Iowa DOT engineers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Multiple motor function and strength assessment tools exist for the evaluation of neuromuscular diseases, but most do not directly assess functional ability in the patients' daily physical activity in their home environment. In this study our aim was to assess: 1) the feasibility and accuracy of physical activity monitoring during two days in a home environment of five DMD patients using a non-commercialized monitor containing a 3D accelerometer and a gyroscope, 2) if a difference in the physical activity parameters could be measured before and one month after starting prednisolone. We reliably quantified the time spend sitting, standing, lying, walking, the number of steps taken, the cadence, the number of walking episodes and their duration as well as how these were distributed over the day. Parameters possibly reflecting endurance, such as the duration of the walking episodes or the succession of two or three walking episodes lasting more than 30 s were the most improved after prednisolone treatment. This degree of detailed determination of physical activity in a home environment has not been previously reported in neuromuscular disorders to our knowledge and some of the reported parameters are potential new outcome measures in clinical trials.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is a sustained controversy in the literature about the role and utility of self-monitoring of blood glucose (SMBG) in type 2 diabetes. The study results in this field do not provide really useful clues for the integration of SMBG in the follow-up of the individual patient, because they are based on a misconception of SMBG. It is studied as if it was a medical treatment whose effect on glycemic control is to be isolated. However, SMBG has no such intrinsic effect. It gains its purpose only as an inseparable component of a comprehensive and structured educational strategy. To be appropriate this strategy cannot be based on the health care professionals' view on diabetes only. It rather has to be tailored to the individual patient's needs through an ongoing process of shared reflection with him.