979 resultados para Condylar resorption (CR)
Resumo:
Selectivity studies for the determination of Cr(VI) using the catalytic oxidation of the o-dianisidine by hydrogen peroxide showed two distincts situations. In the first, when interferents were studied by a univariate procedure, Cr(III) and Cu(II) cause serious interferences even at the 2:1 proportion, relative to Cr(VI), while Fe(III) interfered at the 15:1 ratio and EDTA at the 10:1 ratio. On the other hand, when a multivariate investigation was performed, Cr(III) did not present any significant principal effects and its significant interaction effects were negative, in contrast to EDTA, that presented positive interaction effects although, like Cr(III), did not show significant interaction effects. In view of the interferent's action it become necessary to separate Cr(VI) by extraction with methylisobutylketone in a chloridric acid medium before its determination in vegetals and in wastewater from a cellulose industry samples. Using this procedure, the method precision is ±0,5% at the 10 ng/mL Cr(VI) concentration level. The detection and quantification limits, calculated by means of absorbance measurements of ten replicates of blank reagents were 1,1 and 3,2 ng/mL, respectively. The results obtained with real samples showed a relative standard deviation between 1,2% and 3,0% relative to their reference values.
Resumo:
The equilibria, the spectra and the identities of the species of Cr(VI) that are present in aqueous solution have long been an active subject of discussion in the literature. In this paper, three different chemometric methodologies are applied to sets of UV/Visible spectra of aqueous Cr(VI) solutions, in order to solve a chemical system where there is no available information concerning the composition of the samples nor spectral information about the pure species. Imbrie Q-mode factor analysis, followed by varimax rotation and Imbrie oblique projection, were used to estimate the composition of Cr(VI) equilibrium solutions and, by combining these results with the k-matrix method, to obtain the pure spectra of the species. Evolving factor analysis and self modeling curve resolution were used to confirm the number of the species and the resolution of the system, respectively. Sets of 3.3×10-4 and 3.3×10-5 mol L-1 Cr(VI) solutions, respectively, were analyzed in the pH range from 1 to 12. Two factors were identified, which were related to the chromate ion (CrO4(2-)) and bichromate ion (HCrO4-). The pK of the equilibrium was estimated as 5.8.
Resumo:
The present experiment describes an easy procedure for obtaining SiO2/ZrO2 by reacting ZrOCl2 with SiO2 with the following characteristics: S BET = 500 m² g-1 and an average pore diameter of 6 nm. The material obtained presented 1.3 wt% ZrO2 content corresponding to 140 mumol g-1. The average density of ZrO2 onto SiO2/ZrO2 matrix is 2.8x10-11 mol cm-2. The adsorption isotherm for Cr(VI) showed a maximum of adsorption value (200 mumol g-1) at pH 2. The adsorption can be described by the reaction: =Zr(OH)2 + 2HCrO4- + 2H+ [(=Zr(OH2+)2) (HCrO4-)2]. Above the zero point of charge, i.e. pH > 5.5 due to the surface charge inversion, desorption of Cr(VI) occurs according to the reaction: [(=Zr(OH2+)2) (HCrO4-)2] + 6OH-
(=ZrO2)2- + 6H2O + 2CrO4(2-).
Resumo:
In this study, the preparation of the xerogel anilinepropylsilica is reported. The ability of the xerogel for extracting Al(III), Cr(III) and Fe(III) from ethanol was investigated at 25 ºC. The xerogel adsorption capacities were obtained from the adsorption isotherms by using the batch method. Flame atomic absorption spectrometry (FAAS) was used to estimate the concentration of metal ions in solution. The adsorption affinity follows the series Cr(III) > Fe(III) > Al(III) and the maximum adsorption capacities of the metal ions were 0.61, 0.52 and 0.43 mmol g-1, respectively.
Resumo:
Two samples of residues from iron mining plants have been investigated for their retention capacity of As, Cu, Cr, and Pb. The sample with the higher content of iron oxides showed the highest capacity to retain metals. The adsorption affinity series changes from Pb>Cu>Cr~As to As>Pb>Cu>Cr or As>Cu>Cr>Pb, depending on the material and the concentration of the initial solution. In the competitive environment, the Pb adsorption decreases and the As, Cu and Cr adsorption increases. Sequential extraction procedures, carried out after adsorption batch experiments, showed that the most important adsorption process occurs in the oxide fraction and that the major part of the absorbed metal is remobilized from exchangeable and oxide fractions.
Resumo:
This study investigates the use of wild animal hair of C. brachyurus, C. thous and L. pardalis as biomonitors of trace metal at Parque Nacional das Emas, Brazil. Results reveal a strong correlation between Cd and Pb as well as Cu and Zn, which suggests a single source of emission. Most metals showed a lower or equal concentration than those obtained in previous studies. The research shows that monitoring may be performed only with Zn, Pb, Cd, and Cr because of statistical similarity and of a non-natural occurrence of large amounts of the material under analysis.
Resumo:
The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.
Resumo:
The synthesis and characterization of crosslinked chitosan microbeads and their application in the removal of Cr(VI) are described. New kinetic and thermodynamic parameters of Cr(VI) adsorptions processes were found using continuous isothermal calorimetry. All adsorption processes are exothermic in nature. However, a multivariate statistical analysis have pointed out that adsorption enthalpies were affected by important binary interactions of the initial Cr(VI) in solution and temperature. The adsorption energetic data were well fitted to a kinetic exponential model, which have indicated fractionary adsorption kinetic orders.
Resumo:
The clay mineral montmorillonite-K10 (MT), treated under acidic medium and saturated with potassium ions (MTK), was employed in sorption and desorption studies aiming the preconcentration of Cr(III) and the speciation analysis of chromium. The sorption process of Cr(III) was close to 100%, suggesting that MTK was a good material for Cr(III) preconcentration, although, the maximum recovery in HNO3 solution was near 89%. On the other hand, Cr(VI) practically was not retained in MTK, suggesting this material as an appropriate mineral phase to be used in speciation analysis of chromium in aqueous medium.
Resumo:
A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 ºC, respectively, using 15 µg de Mg(NO3)2 as chemical modifier. Characteristics mass of 14, 6 and 220 ρg and detection limits of the method of 0.07, 0.38 and 0.75 µg L-1 were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 µg L-1 was observed for Cr and V, respectively, and not detectable levels for Ni.
Resumo:
Trace metal content of three fish species harvested from a tank located in the City of Guarapuava-PR, Brazil were determined by digestion and voltametry. Trace metal content in fish samples were 0.10-1.30 µg/g (muscle) and 0.45-15.90 µg/g (liver) for chromium, 0.35-2.56 µg/g (muscle) and 2.32-34.30 µg/g (liver) for lead. The levels of lead and chromium in fish samples were higher than the recommended legal limits for human consumption. To assess the dietary intake of Cr and Pb by fish, weekly intake was calculated based on average metals contents and weekly consumption of fish and it compared with PTWI (Provisional Tolerable Weekly Intake). The Cr and Pb have achieved up to 25 and 45%, respectively, of PTWI recommended by WHO/FAO.
Indirect spectrophotometric method for determination of captopril using Cr(VI) and diphenylcarbazide
Resumo:
A spectrophotometric method for the indirect determination of captopril (CP) in pharmaceutical formulations is proposed. The proposed procedure is based on the oxidation of captopril by potassium dichromate and the determination excess oxidant on the basis of its reaction with diphenylcarbazide (DPC). Under the optimum conditions, a good linear relationship (r = 0.9997) was obtained in the range of 0.08-3.5 µg mL-1. The assay limits of detection and quantitation were 0.024 and 0.08 µg mL-1, respectively. The results obtained for captopril determination in pharmaceuticals using the proposed method and those obtained with the US Pharmacopoeia method were in good agreement at the 95% confidence level.
Resumo:
The adsorption of Cr(VI) in aqueous solution by magnetic particles of crosslinked chitosan-ethylenediamine-Fe(III) (MPCh-EDA-FeCL) was studied in a batch system. Fe3+ in the MPCh-EDA-FeCL permitted that adsorption of Cr(VI) occurred with maximum efficiency between pH 3 and 11. The maximum adsorption capacity at pH 7.0 was 81.04 mg g-1 at 25 ºC. The adsorption kinetic process was described by the pseudo-second-order model. Thermodynamic parameters indicated spontaneous, exothermic and chemical adsorption nature. The adsorbent was successively regenerated using a 0.1 mol L-1 NaOH solution. Results were satisfactory for treatment of wastewater from the electroplating industry.
Resumo:
The Mg-vacancy binding free enthalpy of Al-Cr solid solution alloys with Mg addition was calculated by electrical resistivity measurements. The obtained value is lower than that obtained for dilute Al-Mg alloys with almost the same Mg content and may be attributed to the diffusion of Mg.
Resumo:
Estudou-se a distribuição de Cr, Ni, Cu, Cd e Pb em frações de substâncias húmicas (SH) de diferentes tamanhos moleculares. As SH foram extraídas de amostras de água (SHA) e de sedimentos de superfície (SHSS), interface/água (SHSI) e fundo (SHSF) coletados no reservatório de captação de água superficial Anhumas, localizado no município de Araraquara-SP. Para a extração das SH utilizaram-se os procedimentos recomendados pela Sociedade Internacional de Substâncias Húmicas. Após purificação por diálise, as SH foram fracionadas com base no tamanho molecular utilizando-se sistema de fracionamento seqüencial por ultrafiltração e fluxo tangencial. O fracionamento das amostras de SHA permitiu caracterizar uma distribuição de massa relativamente uniforme dentre as frações de diferentes tamanhos moleculares, com valores maiores nas frações F2 (20,8%) e F4 (23,8%). Exceto para os íons Pb(II) e Cu(II) os quais apresentaram concentrações relativamente mais altas nas frações F2 e F4, respectivamente, de maneira geral, crômio, níquel, cádmio e chumbo têm distribuições similares nas cinco frações com tamanhos moleculares maiores e médios (F1 a F5). Quanto às distribuições de massa nas diferentes frações de substâncias húmicas extraídas de amostras de sedimento de superfície (SHSS), sedimento interface/água (SHSI) e sedimento de fundo (SHSF), as três amostras apresentaram 42-48% das SH nas frações com maiores tamanhos moleculares (F1 e F2), 29-31% nas frações intermediárias (F3 e F4) e 13-20% nas frações com menores tamanhos moleculares (F5 e F6). De modo geral, caracterizaram-se para os íons metálicos, distribuições similares dentre as respectivas frações F1 a F6. Exceções para Pb(II) e Ni(II) em sedimento de superfície com concentrações relativamente menores nas frações F2 e F4, respectivamente.