949 resultados para Concentration-time response modelling


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new method and circuit for the conversion of binary phase-shift keying (BPSK) signals into amplitude shift keying signals. The basic principles of the conversion method are the superharmonic injection and locking of oscillator circuits, and interference phenomena. The first one is used to synchronize the oscillators, while the second is used to generate an amplitude interference pattern that reproduces the original phase modulation. When combined with an envelope detector, the proposed converter circuit allows the coherent demodulation of BPSK signals without need of any explicit carrier recovery system. The time response of the converter circuit to phase changes of the input signal, as well as the conversion limits, are discussed in detail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gas sensing systems based on low-cost chemical sensor arrays are gaining interest for the analysis of multicomponent gas mixtures. These sensors show different problems, e.g., nonlinearities and slow time-response, which can be partially solved by digital signal processing. Our approach is based on building a nonlinear inverse dynamic system. Results for different identification techniques, including artificial neural networks and Wiener series, are compared in terms of measurement accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'ectodysplasine Al (EDA1 ou EDA), un ligand de la famille du TNF, et son récepteur EDAR favorisent le développement des poils, des dents et de plusieurs types de glandes. Chez l'humain, une déficience en EDA cause une dysplasie ectodermique liée à l'X, caractérisée par la genèse défectueuse des phanères. Les souris Tabby, déficientes en Eda, présentent des symptômes similaires. Nous démontrons que les souris Tabby sont en moyenne 7% plus légères que les contrôles au moment du sevrage. Ce phénotype ne dépend pas du génotype des petits, mais exclusivement de celui de la mère, suggérant que l'absence d'EDA perturbe la fonction mammaire. La glande mammaire se développe en plusieurs étapes, principalement à la puberté et pendant la grossesse. Nous avons généré des anticorps pour activer ou inhiber la signalisation d'EDAR. Les anticorps agonistes corrigent le développement de souris ou de chiens déficients en EDA, alors que les antagonistes provoquent une dysplasie ectodermique chez les souris saines. L'exposition répétée de souris Tabby aux anticorps agonistes après le sevrage accroît la taille et la fonction des glandes sébacées, démonstration pharmacologique qu'EDA contrôle l'homéostasie de la glande sébacée adulte. Ces outils seront utiles pour étudier la fonction d'EDA aux diverses étapes du développement de la glande mammaire. Fc-EDAl, un stimulateur d'EDAR, est en phase d'évaluation clinique. Nous avons montré que les structures dépendantes d'EDA qui se forment à différentes étapes du développement répondent à l'action du Fc-EDAl dans des fenêtres temporelles étroites ou larges. De plus, certaines structures peuvent être induites plusieurs jours après le début naturel de leur formation. Alors que la plupart des structures se forment suite à un seul jour d'activation d'EDAR, d'autre demandent un temps de stimulation plus long. La formation des dents est régulée par des signaux activateurs et inhibiteurs. Une forte stimulation d'EDAR spécifiquement appliquée aux deux premières molaires induit des signaux négatifs qui avortent la formation de la troisième molaire, alors qu'une forte stimulation donnée à la troisième molaire la rend hypertrophique tout en induisant parfois une quatrième molaire jamais observée chez les souris de type sauvage ou Tabby. EDA est donc un activateur important de la formation dentaire. Pris dans leur ensemble, ces résultats ont des implications pour la thérapie des dysplasies ectodermiques. - The TNF family ligand Ectodysplasin Al (EDA1 or EDA) and its receptor ED AR regulate embryonic development of hair, teeth and several types of glands. In humans, EDA mutations cause X-linked hypohidrotic ectodermal dysplasia (XLHED), a condition characterized by defective development of skin appendages. £da-deficient (Tabby) mice suffer from similar defects. We observed that Tabby pups at weaning were on average 7% smaller than WT controls, a phenotype that was curiously not linked to the genotype of pups, but to that of mothers, suggesting decreased mammary gland function in the absence of EDA. Mammary glands develop in several steps, most of which are post-natal. We generated monoclonal antibodies to block or activate EDAR signaling. Agonist antibodies rescued developmental defects when administered timely in £cfo-deficient mice and dogs, whereas blocking antibodies induced ectodermal dysplasia in WT mice. Agonist antibodies administered after weaning in £da-deficient mice for several months markedly increased both size and function of sebaceous glands, providing the first demonstration that pharmacological activation of the EDAR pathway in adults can correct important aspects of the dry skin phenotype. This also highlights a role for EDA1 in the homeostasis of adult sebaceous glands. These tools will be useful to study the function of EDA 1 at different stages of mammary gland development. Another EDAR agonist, Fc-EDAl, is currently evaluated in clinical trials. We found that EDA 1-dependent structures forming at different time points during development can respond to Fc-EDAl during time response windows that are narrow or wide. Also, some structures can be triggered up to several days after their normal time of induction. While most structures could be rescued by a single day of EDAR signaling, others required longer exposure times to form. Tooth formation is regulated by activating and inhibitory signals that impact one on the other. When strong EDAR signals were specifically given to the first two molars, overwhelming inhibitory signals completely inhibited formation of the third molar. In contrast, strong signals specifically given to the third molar induced hypertrophy of the later with occasional appearance of a fourth molar never observed in WT or £da-deficient mice. This clearly positions EDA as an important activating signal in tooth formation. Taken together, these results have implications for the therapy of ectodermal dysplasias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over 70% of the total costs of an end product are consequences of decisions that are made during the design process. A search for optimal cross-sections will often have only a marginal effect on the amount of material used if the geometry of a structure is fixed and if the cross-sectional characteristics of its elements are property designed by conventional methods. In recent years, optimalgeometry has become a central area of research in the automated design of structures. It is generally accepted that no single optimisation algorithm is suitable for all engineering design problems. An appropriate algorithm, therefore, mustbe selected individually for each optimisation situation. Modelling is the mosttime consuming phase in the optimisation of steel and metal structures. In thisresearch, the goal was to develop a method and computer program, which reduces the modelling and optimisation time for structural design. The program needed anoptimisation algorithm that is suitable for various engineering design problems. Because Finite Element modelling is commonly used in the design of steel and metal structures, the interaction between a finite element tool and optimisation tool needed a practical solution. The developed method and computer programs were tested with standard optimisation tests and practical design optimisation cases. Three generations of computer programs are developed. The programs combine anoptimisation problem modelling tool and FE-modelling program using three alternate methdos. The modelling and optimisation was demonstrated in the design of a new boom construction and steel structures of flat and ridge roofs. This thesis demonstrates that the most time consuming modelling time is significantly reduced. Modelling errors are reduced and the results are more reliable. A new selection rule for the evolution algorithm, which eliminates the need for constraint weight factors is tested with optimisation cases of the steel structures that include hundreds of constraints. It is seen that the tested algorithm can be used nearly as a black box without parameter settings and penalty factors of the constraints.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrically driven Er3+ doped Si slot waveguides emitting at 1530 nm are demonstrated. Two different Er3+ doped active layers were fabricated in the slot region: a pure SiO2 and a Si-rich oxide. Pulsed polarization driving of the waveguides was used to characterize the time response of the electroluminescence (EL) and of the signal probe transmission in 1 mm long waveguides. Injected carrier absorption losses modulate the EL signal and, since the carrier lifetime is much smaller than that of Er3+ ions, a sharp EL peak was observed when the polarization was switched off. A time-resolved electrical pump & probe measurement in combination with lock-in amplifier techniques allowed to quantify the injected carrier absorption losses. We found an extinction ratio of 6 dB, passive propagation losses of about 4 dB/mm, and a spectral bandwidth > 25 nm at an effective d.c. power consumption of 120 μW. All these performances suggest the usage of these devices as electro-optical modulators.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study reports the parameters which influence on extraction of humic substances (HS) from peat. The yield, organic and inorganic contend, E4/E6 ratio and elemental composition (C,H,N) of the extracted HS have been determined. The functional groups were identified by Fourier-transform infrared espectroscopy. The results showed influence of the extractor type, concentration, time, temperature and granular texture of the sample in the extraction. This work contributes to better understanding of the extraction process showing the necessity of the standard method to extract humic substances from soil

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dynamic mechanical analysis (DMA) is widely used in materials characterization. In this work, we briefly introduce the main concepts related to this technique such as, linear and non-linear viscoelasticity, relaxation time, response of material when it is submitted to a sinusoidal or other periodic stress. Moreover, the main applications of this technique in polymers and polymer blends are also presented. The discussion includes: phase behavior, crystallization; spectrum of relaxation as a function of frequency or temperature; correlation between the material damping and its acoustic and mechanical properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Avalanche photodiodes operated in the Geiger mode present very high intrinsic gain and fast time response, which make the sensor an ideal option for those applications in which detectors with high sensitivity and velocity are required. Moreover, they are compatible with conventional CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. Despite these excellent qualities, the photodiode suffers from high intrinsic noise, which degrades the performance of the detector and increases the memory area to store the total amount of information generated. In this work, a new front-end circuit that allows low reverse bias overvoltage sensor operation to reduce the noise in Geiger mode avalanche photodiode pixel detectors is presented. The proposed front-end circuit also enables to operate the sensor in the gated acquisition mode to further reduce the noise. Experimental characterization of the fabricated pixel with the conventional HV-AMS 0.35µm technology is also presented in this article.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kalman filter is a recursive mathematical power tool that plays an increasingly vital role in innumerable fields of study. The filter has been put to service in a multitude of studies involving both time series modelling and financial time series modelling. Modelling time series data in Computational Market Dynamics (CMD) can be accomplished using the Jablonska-Capasso-Morale (JCM) model. Maximum likelihood approach has always been utilised to estimate the parameters of the JCM model. The purpose of this study is to discover if the Kalman filter can be effectively utilized in CMD. Ensemble Kalman filter (EnKF), with 50 ensemble members, applied to US sugar prices spanning the period of January, 1960 to February, 2012 was employed for this work. The real data and Kalman filter trajectories showed no significant discrepancies, hence indicating satisfactory performance of the technique. Since only US sugar prices were utilized, it would be interesting to discover the nature of results if other data sets are employed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous studies have shown that the vascular reactivity of the mouse aorta differs substantially from that of the rat aorta in response to several agonists such as angiotensin II, endothelin-1 and isoproterenol. However, no information is available about the agonists bradykinin (BK) and DesArg9BK (DBK). Our aim was to determine the potential expression of kinin B1 and B2 receptors in the abdominal mouse aorta isolated from C57BL/6 mice. Contraction and relaxation responses to BK and DBK were investigated using isometric recordings. The kinins were unable to induce relaxation but concentration-contraction response curves were obtained by applying increasing concentrations of the agonists BK and DBK. These effects were blocked by the antagonists Icatibant and R-715, respectively. The potency (pD2) calculated from the curves was 7.0 ± 0.1 for BK and 7.3 ± 0.2 for DBK. The efficacy was 51 ± 2% for BK and 30 ± 1% for DBK when compared to 1 µM norepinephrine. The concentration-dependent responses of BK and DBK were markedly inhibited by the arachidonic acid inhibitor indomethacin (1 µM), suggesting a mediation by the cyclooxygenase pathway. These contractile responses were not potentiated in the presence of the NOS inhibitor L-NAME (1 mM) or endothelium-denuded aorta, indicating that the NO pathway is not involved. We conclude that the mouse aorta constitutively contains B1 and B2 subtypes of kinin receptors and that stimulation with BK and DBK induces contractile effect mediated by endothelium-independent vasoconstrictor prostanoids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En salle d’opération, les tâches de l’anesthésiste sont nombreuses. Alors que l’utilisation de nouveaux outils technologiques l’informe plus fidèlement sur ce qui se passe pour son patient, ces outils font que ses tâches deviennent plus exigeantes. En vue de diminuer cette charge de travail, nous avons considérer l’administration automatique d’agents anesthésiques en se servant de contrôle en boucle fermée. À cette fin, nous avons développé un système d’administration d’un agent anesthésique (le propofol) visant à maintenir à un niveau optimal la perte de conscience du patient pendant toute la durée d’une chirurgie. Le système comprend un ordinateur, un moniteur d’anesthésie et une pompe de perfusion. L’ordinateur est doté d’un algorithme de contrôle qui, à partir d’un indice (Bispectral IndexTM ou BIS) fournit par le moniteur d’anesthésie détermine le taux d’infusion de l’agent anesthésiant. Au départ, l’anesthésiste choisit une valeur cible pour la variable de contrôle BIS et l’algorithme, basé sur système expert, calcule les doses de perfusion de propofol de sorte que la valeur mesurée de BIS se rapproche le plus possible de la valeur cible établie. Comme interface-utilisateur pour un nouveau moniteur d’anesthésie, quatre sortes d’affichage ont été considérés: purement numérique, purement graphique, un mélange entre graphique et numérique et un affichage graphique intégré (soit bidimensionnel). À partir de 20 scenarios différents où des paramètres normaux et anormaux en anesthésie étaient présentés à des anesthésistes et des résidents, l’étude des temps de réaction, de l’exactitude des réponses et de la convivialité (évaluée par le NASA-TLX) a montré qu’un affichage qui combine des éléments graphiques et numériques était le meilleur choix comme interface du système. Une étude clinique a été réalisée pour comparer le comportement du système d’administration de propofol en boucle fermée comparativement à une anesthésie contrôlée de façon manuelle et conventionnelle où le BIS était aussi utilisé. Suite à l’approbation du comité d’éthique et le consentement de personnes ayant à subir des chirurgies générales et orthopédiques, 40 patients ont été distribués également et aléatoirement soit dans le Groupe contrôle, soit dans le Groupe boucle fermée. Après l’induction manuelle de propofol (1.5 mg/kg), le contrôle en boucle fermée a été déclenché pour maintenir l’anesthésie à une cible de BIS fixée à 45. Dans l’autre groupe, le propofol a été administré à l’aide d’une pompe de perfusion et l’anesthésiste avait aussi à garder manuellement l’indice BIS le plus proche possible de 45. En fonction du BIS mesuré, la performance du contrôle exercé a été définie comme excellente pendant les moments où la valeur du BIS mesurée se situait à ±10% de la valeur cible, bonne si comprise de ±10% à ±20%, faible si comprise de ±20% à ±30% ou inadéquate lorsque >±30%. Dans le Groupe boucle fermée, le système a montré un contrôle excellent durant 55% du temps total de l’intervention, un bon contrôle durant 29% du temps et faible que pendant 9% du temps. Le temps depuis l’arrêt de la perfusion jusqu’à l’extubation est de 9 ± 3.7 min. Dans le Groupe contrôle, un contrôle excellent, bon, et faible a été enregistré durant 33%, 33% et 15% du temps respectivement et les doses ont été changées manuellement par l’anesthésiste en moyenne 9.5±4 fois par h. L’extubation a été accomplie après 11.9 ± 3.3 min de l’arrêt de la perfusion. Dans le Groupe boucle fermée, un contrôle excellent a été obtenu plus longtemps au cours des interventions (P<0.0001) et un contrôle inadéquat moins longtemps (P=0.001) que dans le Groupe contrôle. Le système en boucle fermée d’administration de propofol permet donc de maintenir plus facilement l’anesthésie au voisinage d’une cible choisie que l’administration manuelle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. It provides substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected Reaction Monitoring allows targeted assay development but data sets generated contain very limited information. Data mining and analysis of non-targeted high-resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study was to test method precision and accuracy, statistically compare bupivacaine drug concentration in real study samples and verify if high resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy was ranging from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods reveal a coefficient of determination (R2) of 0.9996 and a slope of 1.02 demonstrating a very strong correlation between both methods. Individual sample comparison showed differences from -4.5% to 1.6% well within the accepted analytical error. Moreover, post acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M-56) and m/z 305.2224 ± 5 ppm (M+16) revealed the presence of desbutyl-bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post acquisition analysis allowed us to produce semiquantitative evaluations of the concentration-time profiles for bupicavaine metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis Entitled Electrical switching studies on the thin flims of polyfuran and polyacrylonitrile prepared by plasma polymerisation and vacuum evaporated amorphous silicon.A general introduction to the switching and allied phenomena is presented. Subsequently, developments of switching in thin films are described. The Mott transition is qualitatively presented. The working of a switching transitor is outlined and compared to the switching observed in thin films. Characteristic parameters of switching such as threshold voltage, time response to a, voltage pulse, and delay time are described. The various switching configurations commonly used are discussed. The mechanisms used to explain the switching behaviour like thermal, electrothermal and purely electronic are reviewed. Finally the scope, feasibility and the importance of polymer thin films in switching are highlighted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Se presenta un programa desarrollado mediante GRASS 6.2 que permite calcular el tiempo de concentración en cuencas hidrográficas a partir del modelo digital de elevaciones. El hecho de que no haya ningún comando específico en GRASS que permita calcular el tiempo de concentración nos ha llevado a calcular éste a partir de aquellos comandos que aportan información hidrográfica, utilizando básicamente r.watershed. Además, se analizan los comandos GRASS que dan las direcciones de flujo, sus semejanzas, discrepancias y utilidades. Finalmente, se comparan los resultados obtenidos aplicando diferentes valores a la técnica de adaptación del modelo digital de elevaciones a partir de la información vectorial de la red hidrográfica existente