909 resultados para Coletor solar : Análise experimental


Relevância:

50.00% 50.00%

Publicador:

Resumo:

The technical and economic viability of solar heating for swimming pools is unquestionable, besides there it replaces the high costs and environmental impacts of conventional supply of energy, and it improves an optimization in the pool heating uses. This work applies the principles of the greenhouse effect: advanced thermodynamics, heat retention and equalization of temperature, to optimize the solar heating equipment, reducing the area required by collectors as much as 40% (still estimated value) for commercial collectors, with minor architectural and aesthetic impacts on the environment. It features a solar heating alternative in pools, whose main characteristics: low cost, simplicity in manufacturing and assembly and a faster heating. The system consists of two collectors spiral hoses made of polyethylene with a hundred meters each, and working on a forced flow, with only one pass of the working fluid inside the coils, and is used to pump itself treatment of pool water to obtain the desired flow. One of the collectors will be exposed to direct solar radiation, and the other will be covered by a glass slide and closed laterally, so providing the greenhouse effect. The equipment will be installed in parallel and simultaneously exposed to the sun in order to obtain comparative data on their effectiveness. Will be presented results of thermal tests for this the two cases, with and without transparent cover. Will be demonstrated, by comparison, the thermal, economic and material feasibility of these systems for heating swimming pools.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This work is about a development of a vacuum solar water heater. To accomplish this, some measurements were made, such as flow, water temperature and room temperature, relative humidity, solar power density and wind speed. It first presents a brief explanation about the global situation in relation to the accelerated use of exhaustible energy sources which can result in a breakdown of these for future generations. From this, is proposed to analyze this solar water heater with vacuum tubes during the winter season in Brazil southeastern region, under different environmental conditions. From such ideas became possible to prove through the experimental part, calculations and graphical results that technology and the performance of this device are technical and economically viable, according to the life cycle of this. It was also found that the average monthly production in a maximum heat stroke situation was 193,33kWh and minimum isolation was 57,76kWh. This reveals that this instrument should start to be examined more closely by all, as a way to reduce the use of electricity, which will protect the environment without reducing the comfort of people

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Monitoring gases for environmental, industrial and agricultural fields is a demanding task that requires long periods of observation, large quantity of sensors, data management, high temporal and spatial resolution, long term stability, recalibration procedures, computational resources, and energy availability. Wireless Sensor Networks (WSNs) and Unmanned Aerial Vehicles (UAVs) are currently representing the best alternative to monitor large, remote, and difficult access areas, as these technologies have the possibility of carrying specialised gas sensing systems, and offer the possibility of geo-located and time stamp samples. However, these technologies are not fully functional for scientific and commercial applications as their development and availability is limited by a number of factors: the cost of sensors required to cover large areas, their stability over long periods, their power consumption, and the weight of the system to be used on small UAVs. Energy availability is a serious challenge when WSN are deployed in remote areas with difficult access to the grid, while small UAVs are limited by the energy in their reservoir tank or batteries. Another important challenge is the management of data produced by the sensor nodes, requiring large amount of resources to be stored, analysed and displayed after long periods of operation. In response to these challenges, this research proposes the following solutions aiming to improve the availability and development of these technologies for gas sensing monitoring: first, the integration of WSNs and UAVs for environmental gas sensing in order to monitor large volumes at ground and aerial levels with a minimum of sensor nodes for an effective 3D monitoring; second, the use of solar energy as a main power source to allow continuous monitoring; and lastly, the creation of a data management platform to store, analyse and share the information with operators and external users. The principal outcomes of this research are the creation of a gas sensing system suitable for monitoring any kind of gas, which has been installed and tested on CH4 and CO2 in a sensor network (WSN) and on a UAV. The use of the same gas sensing system in a WSN and a UAV reduces significantly the complexity and cost of the application as it allows: a) the standardisation of the signal acquisition and data processing, thereby reducing the required computational resources; b) the standardisation of calibration and operational procedures, reducing systematic errors and complexity; c) the reduction of the weight and energy consumption, leading to an improved power management and weight balance in the case of UAVs; d) the simplification of the sensor node architecture, which is easily replicated in all the nodes. I evaluated two different sensor modules by laboratory, bench, and field tests: a non-dispersive infrared module (NDIR) and a metal-oxide resistive nano-sensor module (MOX nano-sensor). The tests revealed advantages and disadvantages of the two modules when used for static nodes at the ground level and mobile nodes on-board a UAV. Commercial NDIR modules for CO2 have been successfully tested and evaluated in the WSN and on board of the UAV. Their advantage is the precision and stability, but their application is limited to a few gases. The advantages of the MOX nano-sensors are the small size, low weight, low power consumption and their sensitivity to a broad range of gases. However, selectivity is still a concern that needs to be addressed with further studies. An electronic board to interface sensors in a large range of resistivity was successfully designed, created and adapted to operate on ground nodes and on-board UAV. The WSN and UAV created were powered with solar energy in order to facilitate outdoor deployment, data collection and continuous monitoring over large and remote volumes. The gas sensing, solar power, transmission and data management systems of the WSN and UAV were fully evaluated by laboratory, bench and field testing. The methodology created to design, developed, integrate and test these systems was extensively described and experimentally validated. The sampling and transmission capabilities of the WSN and UAV were successfully tested in an emulated mission involving the detection and measurement of CO2 concentrations in a field coming from a contaminant source; the data collected during the mission was transmitted in real time to a central node for data analysis and 3D mapping of the target gas. The major outcome of this research is the accomplishment of the first flight mission, never reported before in the literature, of a solar powered UAV equipped with a CO2 sensing system in conjunction with a network of ground sensor nodes for an effective 3D monitoring of the target gas. A data management platform was created using an external internet server, which manages, stores, and shares the data collected in two web pages, showing statistics and static graph images for internal and external users as requested. The system was bench tested with real data produced by the sensor nodes and the architecture of the platform was widely described and illustrated in order to provide guidance and support on how to replicate the system. In conclusion, the overall results of the project provide guidance on how to create a gas sensing system integrating WSNs and UAVs, how to power the system with solar energy and manage the data produced by the sensor nodes. This system can be used in a wide range of outdoor applications, especially in agriculture, bushfires, mining studies, zoology, and botanical studies opening the way to an ubiquitous low cost environmental monitoring, which may help to decrease our carbon footprint and to improve the health of the planet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Singapore is located at the equator, with abundant supply of solar radiation, relatively high ambient temperature and relative humidity throughout the year. The meteorological conditions of Singapore are favourable for efficient operation of solar energy based systems. Solar assisted heat pump systems are built on the roof-top of National University of Singapore’s Faculty of Engineering. The objectives of this study include the design and performance evaluation of a solar assisted heat-pump system for water desalination, water heating and drying of clothes. Using MATLAB programming language, a 2-dimensional simulation model has been developed to conduct parametric studies on the system. The system shows good prospect to be implemented in both industrial and residential applications and would give new opportunities in replacing conventional energy sources with green renewable energy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A differential temperature controller is incorporated in a solar water heating system to study the influence of its set points on system performance. The effectiveness of the controller set points DeltaT ON and DeltaT OFF on the pump cycling and energy collection has been studied experimentally and the results are presented in this paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present here, an experimental set-up developed for the first time in India for the determination of mixing ratio and carbon isotopic ratio of air-CO2. The set-up includes traps for collection and extraction of CO2 from air samples using cryogenic procedures, followed by the measurement of CO2 mixing ratio using an MKS Baratron gauge and analysis of isotopic ratios using the dual inlet peripheral of a high sensitivity isotope ratio mass spectrometer (IRMS) MAT 253. The internal reproducibility (precision) for the PC measurement is established based on repeat analyses of CO2 +/- 0.03 parts per thousand. The set-up is calibrated with international carbonate and air-CO2 standards. An in-house air-CO2 mixture, `OASIS AIRMIX' is prepared mixing CO2 from a high purity cylinder with O-2 and N-2 and an aliquot of this mixture is routinely analyzed together with the air samples. The external reproducibility for the measurement of the CO2 mixing ratio and carbon isotopic ratios are +/- 7 (n = 169) mu mol.mol(-1) and +/- 0.05 (n = 169) parts per thousand based on the mean of the difference between two aliquots of reference air mixture analyzed during daily operation carried out during November 2009-December 2011. The correction due to the isobaric interference of N2O on air-CO2 samples is determined separately by analyzing mixture of CO2 (of known isotopic composition) and N2O in varying proportions. A +0.2 parts per thousand correction in the delta C-13 value for a N2O concentration of 329 ppb is determined. As an application, we present results from an experiment conducted during solar eclipse of 2010. The isotopic ratio in CO2 and the carbon dioxide mixing ratio in the air samples collected during the event are different from neighbouring samples, suggesting the role of atmospheric inversion in trapping the emitted CO2 from the urban atmosphere during the eclipse.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho de pesquisa apresenta como objetivo principal o desenvolvimento de investigação experimental dinâmica sobre estrutura real de uma passarela tubular mista aço-concreto. O sistema estrutural objeto deste trabalho corresponde a uma passarela composta por três vãos (32,5m, 17,5m e 20,0m, respectivamente) e dois balanços (7,50m e 5,0m, respectivamente), com comprimento total de 82,5m. A passarela com estrutura contínua de aço com as ligações soldadas se apoia em quatro pórticos também de aço. Estruturalmente está constituída por duas treliças planas que se interligam através de contraventamentos horizontais fixados na corda superior e inferior da treliça e lajes de concreto, formando um sistema misto com interação completa. A estrutura está submetida correntemente à travessia de pedestres e ciclistas. Testes experimentais foram realizados sobre o sistema estrutural e confrontados com resultados numéricos. Para a modelagem numérica do sistema são empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Os resultados experimentais são analisados de acordo com a metodologia desenvolvida, sendo realizada análise modal experimental para a determinação das propriedades dinâmicas: freqüências, modos e taxa de amortecimento, enquanto que os resultados da estrutura, em termos de aceleração de pico, são comparados com os valores limites propostos por diversos autores, normas e recomendações de projeto, para uma avaliação do desempenho da estrutura em relação a vibração quando solicitada pelo caminhar dos pedestres no que diz respeito a critério para conforto humano.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Esta dissertação apresenta a avaliação térmica, econômica e ambiental de um sistema de aquecimento solar (SHS) que é usado em uma usina de asfalto, através de simulação computacional com TRNSYS. O processo escolhido é o aquecimento do betume a partir da temperatura de armazenamento até a temperatura de mistura, usando óleo mineral como fluido de transferência de calor (HTF). Os componentes do sistema são o trocador de calor HTF-betume, o coletor concentrador solar parabólico composto (CPC), o aquecedor auxiliar e a bomba de circulação. A simulação no TRNSYS calcula os balanços de massa e energia no circuito fechado do HTF a cada hora. Dados horários do Ano Meteorológico Típico (TMY) do Rio de Janeiro foram utilizados para executar este trabalho. Em muitos casos, a temperatura do HTF ultrapassou 238C, mostrando que o CPC é apropriado para esta aplicação. Economia de combustível e emissões evitadas foram consideradas para as análises economica e ambiental. Este trabalho descreve as fontes renováveis de energia, os tipos de usinas de asfalto e de aquecedores de betume. Ele também mostra a fração brasileira de algumas destas fontes. Os resultados, portanto, mostram ser possível encorajar políticas públicas ambientalmente corretas para incentivar o uso de energia solar na indústria de asfalto. Além disso, este trabalho pode ajudar na redução da elevada emissão dos gases de efeito estufa a partir da utilização dos combustíveis fósseis nesta indústria.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

EXTRACT (SEE PDF FOR FULL ABSTRACT): Potential (clear-sky) radiation receipt is modeled for the slopes of the H.J. Andrews Experimental Forest Long-Term Ecological Research site in the foothills of the southern Cascade mountains of central Oregon. The modeling method developed by Williams is selected and applied to the forest area for the times of the solstices and equinox as well as mid-month times in January, February, April, and May in order to completely characterize the seasonal change of potential radiation at the location. ... It seems that Lookout Creek approximately divides the Andrews Forest into an area of relatively high potential radiation to the north of the creek and relatively lower potential radiation values to the south of the creek. Potential radiation values seem to be associated with the Andrews GIS data layers of debris flows and predominant tree species zones.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This Thesis project is a part of the research conducted in Solar industry. ABSOLICON Solar Concentrator AB has invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate distribution of density of solar radiation in the focal line of the concentrated parabolic reflectors and to measure radiation from the artificial source of light being a calibration-testing tool.On the basis of the requirements of the company’s administration and needs of designing the concentrated reflectors the operation conditions for the Sun-Walker were formulated. As the first step, the complex design of the whole system was made and division on the parts was specified. After the preliminary conducted simulation of the functions and operation conditions of the all parts were formulated.As the next steps, the detailed design of all the parts was made. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Sun-Walker were assembled and tested. The software part, which controls the Sun-Walker work and conducts measurements of solar irradiation, was created on the LabVIEW basis. To tune and test the software part, the special simulator was designed and assembled.When all parts were assembled in the complete system, the Sun-Walker was tested, calibrated and tuned.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O presente trabalho tem como objetivo estudar o comportamento de camadas superficiais de solo melhorado como base de fundações superficiais. Nesta pesquisa foram realizados ensaios de placa de 30 cm de diâmetro sobre camadas de solo residual compactado e de solo tratado com cimento (teor de 5% de cimento), ambas com 60 cm de espessura. O programa experimental também incluiu a retirada de amostras de campo das camadas de solo melhorado para a execução de ensaios triaxiais drenados (CID) com medida interna de deformações, a fim de obter parâmetros constitutivos para a realização de simulações numéricas. Uma comparação entre os resultados dos ensaios triaxiais com amostras retiradas em campo e moldadas em laboratório (Rohlfes Junior, 1996) é apresentada. A diferença entre os resultados dos ensaios triaxiais com amostras de campo e laboratório foi significativa para o caso das amostras de solo melhorado com cimento, tal fato é atribuído principalmente a dificuldade de mistura em campo. O Método dos Elementos Finitos foi utilizado para simular o comportamento carga x recalque das placas assentes sobre camadas de solo melhorado. O modelo Pseudo-Elástico Não Linear (Hiperbólico) foi empregado na análise numérica para modelar o comportamento dos novos materiais. Os resultados dos ensaios de placa sobre camadas de solo melhorado demonstraram que houve um aumento significativo da capacidade de suporte, além de uma redução considerável dos recalques, quando comparados ao comportamento carga x recalque do solo natural (Cudmani, 1994). A analise do comportamento de fundações superficiais assentes em solos estratificados, através de simulações numéricas, demonstrou ser eficiente para a previsão do comportamento carga x recalque das mesmas.