937 resultados para Cochlear Capsule


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The morphology and the deposition periods of egg capsules by the bruised nassa Nassarius vibex were investigated on two beaches located on the southeast coast of Brazil. The nassariids were associated with the charru mussel Mytella charruana, which forms beds on soft mud-bottoms. A total of 1558 capsules were collected, only from the fronds of the green alga Ulva lactuca, 859 for Camaroeiro Beach and 699 for Cidade Beach. The mean sizes of the egg capsules and numbers of eggs or larvae per capsule were similar on the two beaches, as were the periods of capsule deposition. At Camaroeiro Beach, capsules first appeared in May 2006, reached a peak in August 2006, and disappeared in December 2006. At Cidade Beach, the first capsules were recorded in July 2006, with a peak in August 2006. A second peak was also observed at this beach between January 2007 and April 2007. The two periods of deposition recorded at the latter beach may indicate two periods of recruitment in the same year for N. vibex. Regarding the influence of intertidal level on capsule deposition, there was a significant difference in the number of capsules between the levels at Camaroeiro Beach (F= 7.445, p<0.05), and for the second capsule-deposition peak at Cidade Beach (F= 6.382, p<0.05). This study revealed a selective pattern of capsule deposition, with individuals of N. vibex using only fronds of U. lactuca. This process was influenced by the morphodynamics of the two beaches, with the nassariids maximizing the survival of embryos by depositing more capsules and more eggs per capsule in better-protected parts of the mytilid beds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To report the audiological outcomes of cochlear implantation in two patients with severe to profound sensorineural hearing loss secondary to superficial siderosis of the CNS and discuss some programming peculiarities that were found in these cases. Retrospective review. Data concerning clinical presentation, diagnosis and audiological assessment pre- and post-implantation were collected of two patients with superficial siderosis of the CNS. Both patients showed good hearing thresholds but variable speech perception outcomes. One patient did not achieve open-set speech recognition, but the other achieved 70% speech recognition in quiet. Electrical compound action potentials could not be elicited in either patient. Map parameters showed the need for increased charge. Electrode impedances showed high longitudinal variability. The implants were fairly beneficial in restoring hearing and improving communication abilities although many reprogramming sessions have been required. The hurdle in programming was the need of frequent adjustments due to the physiologic variations in electrical discharges and neural conduction, besides the changes in the impedances. Patients diagnosed with superficial siderosis may achieve limited results in speech perception scores due to both cochlear and retrocochlear reasons. Careful counseling about the results must be given to the patients and their families before the cochlear implantation indication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leao RM, Li S, Doiron B, Tzounopoulos T. Diverse levels of an inwardly rectifying potassium conductance generate heterogeneous neuronal behavior in a population of dorsal cochlear nucleus pyramidal neurons. J Neurophysiol 107: 3008-3019, 2012. First published February 29, 2012; doi:10.1152/jn.00660.2011.-Homeostatic mechanisms maintain homogeneous neuronal behavior among neurons that exhibit substantial variability in the expression levels of their ionic conductances. In contrast, the mechanisms, which generate heterogeneous neuronal behavior across a neuronal population, remain poorly understood. We addressed this problem in the dorsal cochlear nucleus, where principal neurons exist in two qualitatively distinct states: spontaneously active or not spontaneously active. Our studies reveal that distinct activity states are generated by the differential levels of a Ba2+-sensitive, inwardly rectifying potassium conductance (K-ir). Variability in K-ir maximal conductance causes variations in the resting membrane potential (RMP). Low K-ir conductance depolarizes RMP to voltages above the threshold for activating subthreshold-persistent sodium channels (Na-p). Once Na-p channels are activated, the RMP becomes unstable, and spontaneous firing is triggered. Our results provide a biophysical mechanism for generating neural heterogeneity, which may play a role in the encoding of sensory information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Although Enterococcus faecalis is a member of the normal microbiota, it is also a major cause of nosocomial infections. Some strains of E. faecalis produce capsule, which contributes to pathogenesis through evasion of host defenses, and its production is dependent on the capsule (cps) operon polymorphism. This study investigated cps locus polymorphism in distinct lineages of E. faecalis isolated from canals of root-filled teeth with periapical lesions. Methods: Twenty-two E. faecalis isolates were evaluated regarding the cps operon polymorphism and genetic diversity. The 3 known CPS types were determined by polymerase chain reaction. This information was correlated with multilocus sequence typing data, which were used to define genetic lineages. Results: cpsA and cpsB were the only detected genes within the cps operon in 62.5% of E. faecalis strains (14/22), indicative of genotype CPS 1, which lacks capsule expression. The essential genes in the cps operon for capsule production were detected in the remaining strains, whereas 3 belonged to genotype CPS 5 and 5 strains to genotype CPS 2. A total of 14 sequence types (STs) were resolved in 22 E. faecalis isolates. Comparison with the E. faecalis international multilocus sequence typing database revealed that 9 STs were previously found, and that the 5 STs were novel. Conclusions: Certain E. faecalis genotypes from canals of root-filled teeth with periapical lesions belong to lineages associated with capsule expression and production of multiple virulence factors, which might account for their increased pathogenic potential. (J Endod 2012;38:58-61)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of cochlear implants (CI) for communication skills are obtained over the years. There are but a few studies regarding the long-term outcomes in postlingual deaf children who grew up using the electronic device. Aim: To assess the functional results in a group of postlingual children, 10 years after using a CI. Methods: Ten postlingual deaf children, implanted before 18 years of age, participated in this study. We assessed: sentence recognition and speech intelligibility. We documented: device use and function and the patient's academic/occupational status. Study design: series. Results: The mean scores were 73% for sentence recognition in silence and 40% in noise. The average write-down intelligibility score was 92% and the average rating-scale intelligibility score was 4.15. There were no cases of device failure. Regarding educational/vocational status, three subjects graduated from the University. Five quit education after completing high school. Eight subjects had a professional activity. Conclusion: This study showed that cochlear implantation is a safe and reliable procedure. The postlingual profoundly hearing-impaired children after 10 years of CI use developed satisfactory levels regarding speech perception and intelligibility, and completed at least high school and were inserted in the labor market. Clinical Trials Registry: NCT01400178.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cochlear implants are the best treatment for congenital profound deafness. Pediatric candidates to implantation are seen as vulnerable citizens, and the decision of implanting cochlear devices is ultimately in the hands of their parents/guardians. The Brazilian Penal Code dictates that deaf people may enjoy diminished criminal capacity. Many are the bioethical controversies around cochlear implants, as representatives from the deaf community have seen in them a means of decimating their culture and intrinsic values. Objective: This paper aims to discuss, in bioethical terms, the validity of implanting cochlear hearing aids in children by analyzing their vulnerability and the social/cultural implications of the procedure itself, aside from looking into the medical/legal aspects connected to their criminal capacity. Materials and Methods: The topic was searched on databases Medline and Lilacs; ethical analysis was done based on principialist bioethics. Results: Cochlear implants are the best therapeutic option for people with profound deafness and are morally justified. The level of criminal capacity attributed to deaf people requires careful analysis of the subject's degree of understanding and determination when carrying out the acts for which he/she has been charged. Conclusion: Cochlear implants are morally valid. Implantations must be analyzed on an each case basis. ENT physicians bear the ethical responsibility for indicating cochlear implants and must properly inform the child's parents/guardians and get their written consent before performing the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To report the results of cochlear implantation via the middle fossa approach in 4 patients, discuss the complications, and present a detailed description of the programming specifications in these cases. Study Design: Retrospective case review. Setting: Tertiary-care referral center with a well-established cochlear implant program. Patients: Four patients with bilateral canal wall down mastoid cavities who underwent the middle fossa approach for cochlear implantation. Interventions: Cochlear implantation and subsequent rehabilitation. A middle fossa approach with cochleostomy was successfully performed on the most superficial part of the apical turn in 4 patients. A Nucleus 24 cochlear implant system was used in 3 patients and a MED-EL Sonata Medium device in 1 patient. The single electrode array was inserted through a cochleostomy from the cochlear apex and occupied the apical, middle, and basal turns. Telemetry and intraoperative impedance recordings were performed at the end of surgery. A CT scan of the temporal bones was performed to document electrode insertion for all of the patients. Main Outcome Measures: Complications, hearing thresholds, and speech perception outcomes were evaluated. Results: Neural response telemetry showed present responses in all but 1 patient, who demonstrated facial nerve stimulation during the test. Open-set speech perception varied from 30% to 100%, despite the frequency allocation order of the MAP. Conclusion: Cochlear implantation via the middle cranial fossa is a safe approach, although it is a challenging procedure, even for experienced surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cochlear implantation is a safe and reliable method for auditory restoration in patients with severe to profound hearing loss. Objective: To describe the surgical complications of cochlear implantation. Materials and Methods: Information from 591 consecutive multichannel cochlear implant surgeries were retrospectively analyzed. All patients were followed-up for at least one year. Forty-one patients were excluded because of missing data, follow-up loss or middle fossa approach. Results: Of 550 cochlear implantation analyzed, 341 were performed in children or adolescents, and 209 in adults. The mean hearing loss time was 6.3 +/- 6.7 years for prelingual loss and 12.1 +/- 11.6 years for postlingual. Mean follow-up was 3.9 +/- 2.8 years. Major complications occurred in 8.9% and minor in 7.8%. Problems during electrode insertion (3.8%) were the most frequent major complication followed by flap dehiscence (1.4%). Temporary facial palsy (2.2%), canal-wall lesion (2.2%) and tympanic membrane lesion (1.8%) were the more frequent minor complications. No death occurred. Conclusion: There was a low rate of surgical complications, most of them been successfully managed. These results confirm that cochlear implant is a safe surgery and most surgical complications can be managed with conservative measures or minimal intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To characterize the PI component of long latency auditory evoked potentials (LLAEPs) in cochlear implant users with auditory neuropathy spectrum disorder (ANSD) and determine firstly whether they correlate with speech perception performance and secondly whether they correlate with other variables related to cochlear implant use. Methods: This study was conducted at the Center for Audiological Research at the University of Sao Paulo. The sample included 14 pediatric (4-11 years of age) cochlear implant users with ANSD, of both sexes, with profound prelingual hearing loss. Patients with hypoplasia or agenesis of the auditory nerve were excluded from the study. LLAEPs produced in response to speech stimuli were recorded using a Smart EP USB Jr. system. The subjects' speech perception was evaluated using tests 5 and 6 of the Glendonald Auditory Screening Procedure (GASP). Results: The P-1 component was detected in 12/14 (85.7%) children with ANSD. Latency of the P-1 component correlated with duration of sensorial hearing deprivation (*p = 0.007, r = 0.7278), but not with duration of cochlear implant use. An analysis of groups assigned according to GASP performance (k-means clustering) revealed that aspects of prior central auditory system development reflected in the P-1 component are related to behavioral auditory skills. Conclusions: In children with ANSD using cochlear implants, the P-1 component can serve as a marker of central auditory cortical development and a predictor of the implanted child's speech perception performance. (c) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to compare acoustic and perceptual parameters regarding the voice of cochlear implanted children, with normal hearing children. Method: this is a cross-sectional, quantitative and qualitative study. Methods: Thirty six cochlear implanted children aged between 3y and 3 m to 5y and 9 m and 25 children with normal hearing, aged between 3y and 11 m and 6y and 6 m, participated in this study. The recordings and the acoustics analysis of the sustained vowel/a/and spontaneous speech were performed using the PRAAT program. The parameters analyzed for the sustained vowel were the mean of the fundamental frequency, jitter, shimmer and harmonic-to-noise ratio (HNR). For the spontaneous speech, the minimum and maximum frequencies and the number of semitones were extracted. The perceptual analysis of the speech material was analyzed using visual-analogical scales of 100 points, composing the aspects related to the overall severity of the vocal deviation, roughness, breathiness, strain, pitch, loudness and resonance deviation, and instability. This last parameter was only analyzed for the sustained vowel. Results: The results demonstrated that the majority of the vocal parameters analyzed in the samples of the implanted children disclosed values similar to those obtained by the group of children with normal hearing. Conclusion: implanted children who participate in a (re) habilitation and follow-up program, can present vocal characteristics similar to those vocal characteristics of children with normal hearing. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of cochlear implant (CI) in children enables the development of listening and communication skills, allowing the child's progress in school and to be able to obtain, maintain and carry out an occupation. However, the progress after the CI has different results in some children, because many children are able to interact and participate in society, while others develop limited ability to communicate verbally. The need for a better understanding of CI outcomes, besides hearing and language benefits, has spurred the inclusion of quality of life measurements (QOL) to assess the impact of this technology. OBJECTIVE: Identify the key aspects of quality of life assessed in children with cochlear implant. METHOD: Through a systematic literature review, we considered publications from the period of 2000 to 2011. CONCLUSION: We concluded that QOL measurements in children include several concepts and methodologies. When referring to children using CI, results showed the challenges in broadly conceptualizing which quality of life domains are important to the child and how these areas can evolve during development, considering the wide variety of instruments and aspects evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In recent years, the benefits associated with the use of cochlear implants (CIs), especially with regard to speech perception, have proven to surpass those produced by the use of hearing aids, making CIs a highly efficient resource for patients with severe/profound hearing loss. However, few studies so far have assessed the satisfaction of adult users of CIs. Objective: To analyze the relationship between the level of speech perception and degree of satisfaction of adult users of CI. Method: This was a prospective cross-sectional study conducted in the Audiological Research Center (CPA) of the Hospital of Craniofacial Anomalies, University of São Paulo (HRAC/USP), in Bauru, São Paulo, Brazil. A total of 12 users of CIs with pre-lingual or post-lingual hearing loss participated in this study. The following tools were used in the assessment: a questionnaire, "Satisfaction with Amplification in Daily Life" (SADL), culturally adapted to Brazilian Portuguese, as well as its relationship with the speech perception results; a speech perception test under quiet conditions; and the Hearing in Noise Test (HINT)Brazil under free field conditions. Results: The participants in the study were on the whole satisfied with their devices, and the degree of satisfaction correlated positively with the ability to perceive monosyllabic words under quiet conditions. The satisfaction did not correlate with the level of speech perception in noisy environments. Conclusion: Assessments of satisfaction may help professionals to predict what other factors, in addition to speech perception, may contribute to the satisfaction of CI users in order to reorganize the intervention process to improve the users' quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since its approval by FDA in 2001, capsule endoscopy revolutionized the study of small bowel. One of the main limitations of its diffusion has been the high cost. More recently, a new videocapsule system (OMOM CE) has been developed in China and obtained the CE mark. Its cost is approximately half that of other capsule systems. However, there are few studies regarding the clinical experience with this new videocapsule system and none of them has been performed in the western world. Among the limitations of capsule endoscopy, there is also one linked to the diagnostic yield. The rapid transit of the device in the proximal segments implies a high risk of false negatives; an indirect confirmation of this limit is offered by the poor ability to identify the papilla of Vater. In addition, recent studies show that in patients with obscure gastrointestinal bleeding, the negative outcome of capsule endoscopy is correlated to a significant risk of recurrence of anemia in the short term, as well as the presence of small bowel lesions documented by a second capsule endoscopy. It was recently approved the use of a new device called "CapsoCam" (CapsoVision, Inc. Saratoga) characterized by four side cameras that offer a panoramic view of 360 degrees, instead of the front to 160°. Two recent pilot studies showed comparable safety profiles and diagnostic yield with the more standardized capsule. Namely, side vision has made possible a clear visualization of the papilla in 70% of cases. The aim of our study is to evaluate the feasibility and diagnostic yield of these two new devices, which first may allow a reduction in costs. Moreover, their complementary use could lead to a recovery diagnostic in patients with false negative results in an initial investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.