853 resultados para Cleaning validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: An accurate percutaneous puncture is essential for disintegration and removal of renal stones. Although this procedure has proven to be safe, some organs surrounding the renal target might be accidentally perforated. This work describes a new intraoperative framework where tracked surgical tools are superimposed within 4D ultrasound imaging for security assessment of the percutaneous puncture trajectory (PPT). Methods: A PPT is first generated from the skin puncture site towards an anatomical target, using the information retrieved by electromagnetic motion tracking sensors coupled to surgical tools. Then, 2D ultrasound images acquired with a tracked probe are used to reconstruct a 4D ultrasound around the PPT under GPU processing. Volume hole-filling was performed in different processing time intervals by a tri-linear interpolation method. At spaced time intervals, the volume of the anatomical structures was segmented to ascertain if any vital structure is in between PPT and might compromise the surgical success. To enhance the volume visualization of the reconstructed structures, different render transfer functions were used. Results: Real-time US volume reconstruction and rendering with more than 25 frames/s was only possible when rendering only three orthogonal slice views. When using the whole reconstructed volume one achieved 8-15 frames/s. 3 frames/s were reached when one introduce the segmentation and detection if some structure intersected the PPT. Conclusions: The proposed framework creates a virtual and intuitive platform that can be used to identify and validate a PPT to safely and accurately perform the puncture in percutaneous nephrolithotomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative analysis of cine cardiac magnetic resonance (CMR) images for the assessment of global left ventricular morphology and function remains a routine task in clinical cardiology practice. To date, this process requires user interaction and therefore prolongs the examination (i.e. cost) and introduces observer variability. In this study, we sought to validate the feasibility, accuracy, and time efficiency of a novel framework for automatic quantification of left ventricular global function in a clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The field of eating disorders among athletes has recently been Preliminary Validation of the Portuguese Version of the Eating Inventory for Athletes Palmeira, A.L.(1); Veloso, S.(1); Falcão, M.J.(1); and Dosil, J.(2) Table 2. Exploratory Factor Analysis and Cronbach’s Alpha the focus of several publications, reflecting a growing field of interest and research (Dosil, 2008). Some sports demand a strict compliance to restrictive diets at different times of the competitive season, while others like, some types of gymnastics emphasize the thinness of the athletes. Hence there is a need to develop sound measures to evaluate the athletes eating habits and possible eating disorders. The Cuestionario de Hábitos Alimentarios del Deportista (CHAD), is one of these measures. It comprises 5 dimensions: i) Weight Gain Anxiety (e.g. If I eat too much I regret it afterwards; 12 items); ii) Body Image Worries (e.g., I’m always thinking about my body; 6 items,); iii) Irritability (e.g., If the coach speaks about weight matters, I feel anxious; 7 items); iv) Satisfaction/Dissatisfaction with Body Image (e.g., I’m satisfied with my appearance; 5 items); and v) Dieting (e.g., When the season ends, I keep practicing so that I don’t gain weight, 4 items).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perchloroethylene (also known as tetrachloroethylene) is a solvent that has been a mainstay of the dry cleaning industry for decades. Since 1995 the International Agency for Research on Cancer considers that dry cleaning entails exposures that are possibly carcinogenic to humans (Group 2B). Meanwhile, the same institution classified perchloroethylene as probably carcinogenic to humans (Group 2A). Some industries have begun using alternative cleaning methods that do not require the use of perchloroethylene. However, in Portugal this solvent is still the most common dry-cleaning agent. An exploratory study was developed that aimed to find the occupational exposure to perchloroethylene in four Portuguese dry-cleaning stores. Activities involving higher exposure and variables that promote exposure were also investigated. Real-time measurements of volatile organic compounds concentrations were performed using portable equipment (MultiRAE, RAE Systems model – calibrated by isobutylene).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of Social Responsibility (SR) is higher if this business variable is related with other ones of strategic nature in business activity (competitive success that the company achieved, performance that the firms develop and innovations that they carries out). The hypothesis is that organizations that focus on SR are those who get higher outputs and innovate more, achieving greater competitive success. A scale for measuring the orientation to SR has defined in order to determine the degree of relationship between above elements. This instrument is original because previous scales do not exist in the literature which could measure, on the one hand, the three classics sub-constructs theoretically accepted that SR is made up and, on the other hand, the relationship between SR and the other variables. As a result of causal relationships analysis we conclude with a scale of 21 indicators, validated scale with a sample of firms belonging to the Autonomous Community of Extremadura and it is the first empirical validation of these dimensions we know so far, in this context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening programs, particularly the inclusion of specific orthoptic tests to detect visual abnormalities, varies among countries. This study aims to: 1) describes expert perception of issues related with children visual screening; 2) identify specific orthoptic tests to detect visual abnormalities in children visual screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the SmartClean tool. The purpose of this tool is to detect and correct the data quality problems (DQPs). Compared with existing tools, SmartClean has the following main advantage: the user does not need to specify the execution sequence of the data cleaning operations. For that, an execution sequence was developed. The problems are manipulated (i.e., detected and corrected) following that sequence. The sequence also supports the incremental execution of the operations. In this paper, the underlying architecture of the tool is presented and its components are described in detail. The tool's validity and, consequently, of the architecture is demonstrated through the presentation of a case study. Although SmartClean has cleaning capabilities in all other levels, in this paper are only described those related with the attribute value level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The emergence of new business models, namely, the establishment of partnerships between organizations, the chance that companies have of adding existing data on the web, especially in the semantic web, to their information, led to the emphasis on some problems existing in databases, particularly related to data quality. Poor data can result in loss of competitiveness of the organizations holding these data, and may even lead to their disappearance, since many of their decision-making processes are based on these data. For this reason, data cleaning is essential. Current approaches to solve these problems are closely linked to database schemas and specific domains. In order that data cleaning can be used in different repositories, it is necessary for computer systems to understand these data, i.e., an associated semantic is needed. The solution presented in this paper includes the use of ontologies: (i) for the specification of data cleaning operations and, (ii) as a way of solving the semantic heterogeneity problems of data stored in different sources. With data cleaning operations defined at a conceptual level and existing mappings between domain ontologies and an ontology that results from a database, they may be instantiated and proposed to the expert/specialist to be executed over that database, thus enabling their interoperability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The increasing proportion of older adults in the general population and the specific characteristics of this age group show the need for the development of specific instruments to measure quality of life in older adults. The study aimed at describing the development and validation of the Portuguese version of the World Health Organization Quality of Life for Older Persons (WHOQOL-OLD) module. METHODS: The WHOQOL-OLD instrument was administered in a sample of 424 older adults in the city of Porto Alegre, Southern Brazil, in 2005. The questionnaire comprises 24 items divided into six facets: sensory abilities; autonomy; past, present and future activities; social participation; death and dying; and intimacy. Besides the WHOQOL-OLD module, the WHOQOL-BREF, BDI and BHS instruments were also applied. The instrument's internal consistency was assessed using Cronbach's alpha coefficient. RESULTS: The instrument showed adequate internal consistency (Cronbach's coefficients ranging from 0.71 to 0.88), discriminant validity (p<0.01), concurrent validity (correlation coefficients ranging from -0.61 to -0.50) and test-retest reliability (correlation coefficients ranging from 0.58 to 0.82). Findings concerning criterion validity need further studies. CONCLUSIONS: The WHOQOL-Old module is a useful alternative with good psychometric performance in the investigation of quality of life in older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate and sensitive method for determination of 18 polycyclic aromatic hydrocarbons (PAHs) (16 PAHs considered by USEPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) in fish samples was validated. Analysis was performed by microwave-assisted extraction and liquid chromatography with photodiode array and fluorescence detection. Response surface methodology was used to find the optimal extraction parameters. Validation of the overall methodology was performed by spiking assays at four levels and using SRM 2977. Quantification limits ranging from 0.15–27.16 ng/g wet weight were obtained. The established method was applied in edible tissues of three commonly consumed and commercially valuable fish species (sardine, chub mackerel and horse mackerel) originated from Atlantic Ocean. Variable levels of naphthalene (1.03–2.95 ng/g wet weight), fluorene (0.34–1.09 ng/g wet weight) and phenanthrene (0.34–3.54 ng/g wet weight) were detected in the analysed samples. None of the samples contained detectable amounts of benzo[a]pyrene, the marker used for evaluating the occurrence and carcinogenic effects of PAHs in food.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scientific evidence has shown an association between organochlorine compounds (OCC) exposure and human health hazards. Concerning this, OCC detection in human adipose samples has to be considered a public health priority. This study evaluated the efficacy of various solid-phase extraction (SPE) and cleanup methods for OCC determination in human adipose tissue. Octadecylsilyl endcapped (C18-E), benzenesulfonic acid modified silica cation exchanger (SA), poly (styrene-divinylbenzene (EN) and EN/RP18 SPE sorbents were evaluated. The relative sample cleanup provided by these SPE columns was evaluated using gas chromatography with electron capture detection (GC–ECD). The C18-E columns with strong homogenization were found to provide the most effective cleanup, removing the greatest amount of interfering substance, and simultaneously ensuring good analyte recoveries higher than 70%. Recoveries>70% with standard deviations (SD)<15% were obtained for all compounds under the selected conditions. Method detection limits were in the 0.003–0.009 mg/kg range. The positive samples were confirmed by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). The highest percentage found of the OCC in real samples corresponded to HCB, o,p′-DDT and methoxychlor, which were detected in 80 and 95% of samples analyzed respectively. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

GimC/Prefoldin is a hetero-oligomeric complex involved in cytoskeleton biogenesis. In order to identify by two-hybrid system targets that directly interact with Gims and support the stress phenotypes, this work aimed the functional validation of all Gims in saccharomyces cerevisiae.