997 resultados para Circumdenteonal And Interdenteonal Dentine


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the 5-year clinical performance of composite restorations of non-carious cervical lesions (NCCL) using a total-etch adhesive system with or without collagen removal with 10% sodium hypochlorite (NaOCl).Methods: In this study randomized controlled split-mouth clinical trial, one-hundred and thirty-eight NCCL were restored into 30 patients. Each patient received at least one pair of composite restorations (Filtek A110/3M ESPE), bonded either with 2 techniques: Conventional Technique - acid etching with 37% phosphoric acid + Prime & Bond NT (Denstply DeTrey); Deproteinization Technique - acid etching with 37% phosphoric acid + 10% NaOCl for 1 min + Prime & Bond NT. The two techniques were evaluated using the United States Public Health Service (USPHS) criteria at baseline, 18 months, 3 and 5 years. After five years, one-hundred and six restorations were evaluated in 24 patients. Data were analyzed using the Chi-Square test (p < 0.05).Results: There were no statistically significant differences between the two techniques regarding the evaluated parameters (p > 0.05).Conclusion: After 5 years, the application of 10% NaOCl deproteinization on etched dentine did not affect the clinical performance of composite restorations placed in NCCL when compared to the conventional total-etch technique.Clinical significance: Clinical studies evaluating the performance of the Deproteinization Technique are scarce. In this study, this technique showed similar clinical performance at the end of 5 years when compared to a conventional total-etch technique. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of salivary exposure time on the abrasive wear of acid-eroded dentine was evaluated in situ. One-hundred and twenty bovine root dentine slabs were randomly assigned into six groups (A-F) and placed in intraoral palatal devices, which were worn by 10 volunteers for 4 d. On the first day, no erosive/abrasive procedures were carried out. On the following 3 d, erosive challenges were performed extraorally, two times per day, by immersing the device for 90 s in a soft drink. Subsequently, the group A specimens were immediately brushed (40 strokes), and the others were brushed after the following times: B, 20 min; C, 40 min; and D, 60 min. Group E specimens were only acid-eroded and those of group F were only brushed. Dentine wear was measured with a profilometer. ANOVA and Dunnett's test showed that groups A-D did not differ statistically from the control group E but differed from the control group F. The lowest mean value was found for group F. Regression analysis was unable to show salivary effect on dentine wear reduction. The data suggest that the exposure time of saliva of up to 60 min has no effect on reducing the eroded dentine wear by toothbrushing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usefulness of fluoride-releasing restorations in secondary caries prevention may be questioned because of the presence of other common sources of fluoride and because of ageing of the restorations. This study tested the hypothesis that glass-ionomer cement restorations, either aged or unaged, do not prevent secondary root caries, when fluoride dentifrice is frequently used. Sixteen volunteers wore palatal appliances in two phases of 14 days, according to a 2 x 2 crossover design. In each phase the appliance was loaded with bovine root dentine slabs restored with either glass-ionomer or resin composite, either aged or unaged. Specimens were exposed to cariogenic challenge 4 times/day and to fluoridated dentifrice 3 times/day. The fluoride content in the biofilm (FB) formed on slabs and the mineral loss (Delta Z) around the restorations were analysed. No differences were found between restorative materials regarding the FB and the Delta Z, for either aged (p = 0.792 and p = 0.645, respectively) or unaged (p = 1.00 and p = 0.278, respectively) groups. Under the cariogenic and fluoride dentifrice exposure conditions of this study, the glass-ionomer restoration, either aged or unaged, did not provide additional protection against secondary root caries. Copyright (c) 2006 S. Karger AG, Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the effectiveness of isopropyl alcohol, saline or distilled water to prevent the precipitate formed between sodium hypochlorite (NaOCl) and chlorhexidine (CHX) and its effect on the bond strength of an epoxy-based sealer in radicular dentine. Methodology The root canals of 50 extracted human canines (n = 10) were instrumented. In G1, root canals were irrigated with 17% EDTA and 2.5% NaOCl; G2, as G1, except that 2% CHX was used as the final irrigant. In the other groups, intermediate flushes with isopropyl alcohol (G3), saline (G4) or distilled water (G5) were used between NaOCl and CHX. The specimens were submitted to SEM analysis to evaluate the presence of debris and smear layer, in the apical and cervical segments. In sequence, fifty extracted human canines were distributed into five groups (n = 10), similar to the SEM study. After root filling, the roots were sectioned transversally to obtain dentine slices, in the cervical, middle and apical thirds. The root filling was submitted to a push-out bond strength test using an electromechanical testing machine. Statistical analysis was performed using Kruskal–Wallis and Dunn's tests (α = 5%). Results All groups had similar amounts of residue precipitated on the canal walls (P > 0.05). The push-out bond strength values were similar for all groups, independently of the root third evaluated (P > 0.05). Conclusions Isopropyl alcohol, saline and distilled water failed to prevent the precipitation of residues on canal walls following the use of NaOCl and CHX. The residues did not interfere with the push-out bond strength of the root filling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the anti-erosive potential of solutions containing sodium fluoride (NaF, 225 ppm F) and different film-forming agents.Methods: In Phase 1, hydroxyapatite crystals were pre-treated with solutions containing NaF (F), linear sodium polyphosphate (LPP), sodium pyrophosphate tetrabasic (PP), sodium tripolyphosphate (STP), sodium caseinate (SC), bovine serum albumin (BSA), stannous chloride (Sn) and some combinations thereof. Deionized water was the control (C). The pH-stat method was used to evaluate hydroxyapatite dissolution. In Phase 2, the most effective solutions were tested in two independent experiments. Both consisted of an erosion-remineralization cycling model using enamel and dentine specimens with three solution treatments per day. In Phase 2a, the challenge was performed with 0.3% citric acid (pH = 3.8). In Phase 2b, 1% citric acid (pH = 2.4) was used. Hard tissue surface loss was determined profilometrically. Data were analyzed with two-way ANOVA and Tukey tests.Results: In Phase 1, F, LPP, Sn and some of their combinations caused the greatest reduction in hydroxyapatite dissolution. In Phase 2a, C showed the highest enamel loss, followed by LPP. There were no differences between all other groups. In Phase 2b: (F + LPP + Sn) < (F + LPP) = (F + Sn) < (F) = (LPP + Sn) < (LPP) < (Sn) < C. For dentine, in both experiments, only the fluoride-containing groups showed lower surface loss than C, except for LPP + Sn in 2a.Conclusions: F, Sn, LPP reduced enamel erosion, this effect was enhanced by their combination under highly erosive conditions. For dentine, the F-containing groups showed similar protective effect.Clinical significance: The addition of LPP and/or Sn can improve the fluoride solution protection against erosion of enamel but not of dentine. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the transdentinal cytotoxicity of resin-based luting cements (RBLCs), with no HEMA in their composition, to odontoblast-like cells. Human dentine discs 0.3 mm thick were adapted to artificial pulp chambers (APCs) and placed in wells of 24-well plates containing 1 mL of culture medium (DMEM). Two categories of HEMA-free RBLCs were evaluated: group 1, self-adhesive Rely X Unicem (RU; 3M ESPE), applied directly to the dentine substrate; and group 2, Rely X ARC (RARC; 3M ESPE), applied to dentine previously acid-etched and treated with a bonding agent. In group 3 (control), considered as representing 100% cell metabolic activity, no treatment was performed on dentine. The APC/disc sets were incubated for 24 h or 7 days at 37 °C and 5% CO2 . Then, the extracts (DMEM + dental materials components that diffused through dentine) were applied to cultured odontoblast-like MDPC-23 cells for 24 h. After that, the cell viability (MTT assay), cell morphology (SEM), total protein production (TP) and alkaline phosphatase (ALP) activity were assessed. Data from MTT assay and TP production were analysed by Kruskal-Wallis and Mann-Whitney tests (α = 5%). Data from ALP activity were analysed by one-way anova and Tukey's test (α = 5%). In group 1, a slight reduction in cell viability (11.6% and 16.8% for 24-h and 7-day periods, respectively) and ALP activity (13.5% and 17.9% for 24-h and 7-day periods, respectively) was observed, with no significant difference from group 3 (control) (P > 0.05). In group 2, a significant reduction in cell viability, TP production and ALP activity compared with group 3 (control) occurred (P < 0.05), regardless of incubation time. Alteration in MDPC-23 cell morphology was observed only in group 2. HEMA-free Rely X ARC cement caused greater toxicity to odontoblast-like MDPC-23 cells than did Rely X Unicem cement when both resin-based luting materials were applied to dentine as recommended by the manufacturer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To investigate the ability of BioRoot RCS, a tricalcium silicate-based root canal sealer and AH Plus to effectively fill the root canals of contralateral teeth using three evaluation methods, and to investigate also the correlation between the methods. The prepared root canals of ten pairs of contralateral mandibular premolar teeth were filled with gutta-percha and sealer using lateral compaction. The percentage of voids within the root canal was assessed by micro-computed tomography, whilst sealing ability was investigated by fluid transport and leakage of fluorescent microspheres. The interaction of sealer with dentine, and sealer penetration were assessed by confocal microscopy. The void volume, fluid flow, microsphere leakage and sealer interaction with dentine for both materials were compared. Nonparametric (Mann-Whitney) tests were used to compare the % void and fluid transport of the two sealers. Spearman correlation was used to assess the pairwise relationships between the techniques. The level of significance was set to 0.05. BioRoot RCS exhibited significantly more percentage of voids than AH Plus. There was no difference in fluid flow and microsphere penetration. BioRoot RCS exhibited a different pattern of sealer penetration and interaction with the dentine walls compared to AH Plus. For both materials, the pairwise correlations between the three techniques were close to zero, indicating weak relationships. MicroCT analysis revealed a higher void volume for BioRoot RCS. The other techniques did not show a difference between the sealing ability of the sealers. The correlation between the three ex vivo methods of assessment was weak demonstrating their complementarity rather than their concordance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The etiology of bruxism is not well defined. Different factors affecting the central nervous system are considered as risk factors for bruxism. Dental students are not immune to the bruxism, alcohol consumption and tobacco use, despite their training, knowledge of its effects and social responsibility. The purpose of this study was to evaluate the association between bruxism, alcohol consumption and tobacco use among Brazilian dental students. Participants were chosen among 180, 17-29 year-old students at the UNESP’s Dentistry School – Araçatuba Campus. They were divided into those with and without bruxism on the basis at validated clinical criteria. The clinical examinations were carried out by four standardized examiners (Intraexaminer and Interexaminer Unweighted kappa= 0.82, Weighted kappa= 0.89, respectively), in the clinic, with daylight and a tongue depressor. Bruxism was registered with the following categories: no wear facets, wear facets in enamel, dentine wear facets, facets wear half of the crown and wear facets more than 2/3 of the tooth crown. A self report validated questionnaire for alcohol consumption and tobacco use with 29 questions was completed by both groups. Fischer exact test and T-test were used and Odds Ratio and Confidence Interval was estimated. Bruxism was more frequent among cigarette smokers both in men (68.4%) and in women (56.8%). Among all respondents in this group, 82.6% reported that they would like to quit smoking and those who have tried previously to quit (76.4%) found it made them more stressed. Drinker was more frequent in the group with bruxism also (66.5% of the female and 73.5% of the male). 88.4% reported drinking alcohol because it “allows dealing with stress in an adequate way”. Results suggest a positive association between bruxism and alcohol consumption and tobacco use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study assess the effects of bioceramic and poly(lactic-co-glycolic acid) composite (BCP/PLGA) on the viability of cultured macrophages and human dental pulp fibroblasts, and we sought to elucidate the temporal profile of the reaction of pulp capping with a composite of bioceramic of calcium phosphate and biodegradable polymer in the progression of delayed dentine bridge after (30 and 60 days) in vivo. Histological evaluation of inflammatory infiltrate and dentin bridge formation were performed after 30 and 60 days. There was similar progressive fibroblast growth in all groups and the macrophages showed viability. The in vivo study showed that of the three experimental groups: BCP/PLGA composite, BCP and calcium hydroxide (Ca(OH)(2)) dentin bridging was the most prevalent (90 %) in the BCP/PLGA composite after 30 days, mild to moderate inflammatory response was present throughout the pulp after 30 days. After 60 days was observed dentine bridging in 60 % and necrosis in 40 %, in both groups. The results indicate that understanding BCP/PLGA composite is biocompatible and by the best tissue response as compared to calcium hydroxide in direct pulp capping may be important in the mechanism of delayed dentine bridge after 30 and 60 days.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. The aim of this study is to critically evaluate the bond strength (BS) of Glass-Ionomer Cements (GIC) to dentine with microtensile (mu TBS) and microshear (mu SBS) BS tests by assessing their rankings and failure patterns. Methods. Samples were made on flat dentine surfaces and submitted to mTBS and mSBS. The materials used were: high viscosity GIC (Ketac (TM) Molar Aplicap-KM), resin-modified GIC (Fuji II-FII), nano-filled resin-modified GIC (Ketac (TM) N100-N100) and an etch-and-rinse adhesive system with a composite resin (Adper (TM) Single Bond 2 and Z100 (TM)-Z100). All tests were performed with a Universal Testing Machine (24 h water storage, crosshead speed of 1 mm/min). Debonded surfaces were examined with a stereomicroscope (x40) to identify the failure mode. The data was analyzed with two-way ANOVA (p < 0.05) and LSD test. Results. Means were statistically different regarding the tests and materials, indicating that values for BS obtained for each material depend on the test performed. Failure analysis revealed that failures produced by mTBS were mainly cohesive for KM and FII. mu SBS failures were mainly adhesive or mixed for all materials. For the mTBS, the rank was Z100 > FII > KM = N100, whereas for the mSBS it was Z100 = FII = KM > N100. Conclusion: It may be concluded that distinct micro-mechanical tests present different failure patterns and rankings depending on the material to be considered.