572 resultados para Ceratodermia Palmar e Plantar


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary hyperhidrosis is an excessive sweating disorder that occurs in axillae, palms, soles, and craniofacial region. According to Traditional Chinese Medicine (TCM) it is a water metabolism disorder. This study presents a case report treated with TCM, showing more satisfactory results than those by conventional treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research seeking to elucidate the possible effects of different types of physical training on the morphological adaptations of skeletal muscle. Although it is relatively easy to study the effects of exercise training in humans, such research becomes limited due to the invasive nature of the biopsies and the risk inherent in the use of human subjects. Thus, the application of animal models of training has been considered an appropriate strategy for the study of muscular adaptations in response to exercise. Objective: This study used a rodent model to determine the possible effects of aerobic and strength training on the CSA of fibers of the plantaris muscle. Methods: 24 male Wistar rats (80 to 120 days, 250 to 400 g) were randomly divided into 3 groups: aerobic training (TA, n = 8), strength training (ST, n = 8) and control (CO, n = 8). The animals in groups TA and TF were subjected to 8 weeks of training, while the animals of group C remained without any stimulus from start to finish the training period. At the end of the experiment, the animals were sacrificed and right plantar muscles dissected and removed. For morphological and morphometric analysis of muscle fibers was performed staining was performed H.E. Results: There was no significant difference in initial body weight between experimental groups. After 8 weeks of training, the TA group showed a significant reduction in final body weight, compared to CO and TF groups. With respect to the CSA of fibers of the plantaris muscle, no significant difference between the groups CO and TA. On the other hand, the strength training promoted a significant increase in AST of the group TF in compared with the groups CO and TA. Conclusion: Strength training used in this study promoted an increase in CSA of fibers of the plantaris muscle. On the other hand, animals submitted to aerobic training showed no changes in the CSA of the fibers, however, there was reduction in PC animals. The data strongly suggest the use of animal model of strength training used in this study as an appropriate strategy for studying the hypertrophic response of skeletal muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Biotecnologia Animal - FMVZ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Biotecnologia Animal - FMVZ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of video-assisted thoracic sympathectomy (VATS)in children are unknown. To investigate the improvement in quality of life (QOL) of a group of 45 children who did and did not undergo VATS for the treatment of palmar hyperhidrosis (PH) 4 years after the initial evaluation. Forty-five children with PH were initially evaluated. Children were divided into two groups: 30 in the VATS group and 15 in the control group. We studied the evolution of PH, negative effect of hyperhidrosis on the QOL before the treatment, and improvement in QOL after treatment. Twenty-five patients (83.4%) in the VATS group experienced great improvement in PH, and five (16.6%) experienced partial improvement; 12 (80.0%) children from the control group had some type of improvement, and three (20.0%) had partial improvement. Two (13.3%) children in the control group and 23 (76.7%) in the VATS group had great improvement in QOL. For children with PH and poor QOL, VATS is better than no treatment. It produces better results with regard to sweating and greater improvement in QOL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimal levels of noise stimulation have been shown to enhance the detection and transmission of neural signals thereby improving the performance of sensory and motor systems. The first series of experiments in the present study aimed to investigate whether subsensory electrical noise stimulation applied over the triceps surae (TS) in seated subjects decreases torque variability during a force-matching task of isometric plantar flexion and whether the same electrical noise stimulation decreases postural sway during quiet stance. Correlation tests were applied to investigate whether the noise-induced postural sway decrease is linearly predicted by the noise-induced torque variability decrease. A second series of experiments was conducted to investigate whether there are differences in torque variability between conditions in which the subsensory electrical noise is applied only to the TS, only to the tibialis anterior (TA) and to both TS and TA, during the force-matching task with seated subjects. Noise stimulation applied over the TS muscles caused a significant reduction in force variability during the maintained isometric force paradigm and also decreased postural oscillations during quiet stance. Moreover, there was a significant correlation between the reduction in force fluctuation and the decrease in postural sway with the electrical noise stimulation. This last result indicates that changes in plantar flexion force variability in response to a given subsensory random stimulation of the TS may provide an estimate of the variations in postural sway caused by the same subsensory stimulation of the TS. We suggest that the decreases in force variability and postural sway found here are due to stochastic resonance that causes an improved transmission of proprioceptive information. In the second series of experiments, the reduction in force variability found when noise was applied to the TA muscle alone did not reach statistical significance, suggesting that TS proprioception gives a better feedback to reduce force fluctuation in isometric plantar flexion conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: High-frequency trains of electrical stimulation applied over the human muscles can generate forces higher than would be expected by direct activation of motor axons, as evidenced by an unexpected relation between the stimuli and the evoked contractions, originating what has been called “extra forces”. This phenomenon has been thought to reflect nonlinear input/output neural properties such as plateau potential activation in motoneurons. However, more recent evidence has indicated that extra forces generated during electrical stimulation are mediated primarily, if not exclusively, by an intrinsic muscle property, and not from a central mechanism as previously thought. Given the inherent differences between electrical and vibratory stimuli, this study aimed to investigate: (a) whether the generation of vibration-induced muscle forces results in an unexpected relation between the stimuli and the evoked contractions (i.e. extra forces generation) and (b) whether these extra forces are accompanied by signs of a centrally-mediated mechanism or whether intrinsic muscle properties are the redominant mechanisms. Methods: Six subjects had their Achilles tendon stimulated by 100 Hz vibratory stimuli that linearly increased in amplitude (with a peak-to-peak displacement varying from 0 to 5 mm) for 10 seconds and then linearly decreased to zero for the next 10 seconds. As a measure of motoneuron excitability taken at different times during the vibratory stimulation, short-latency compound muscle action potentials (V/F-waves) were recorded in the soleus muscle in response to supramaximal nerve stimulation. Results: Plantar flexion torque and soleus V/F-wave amplitudes were increased in the second half of the stimulation in comparison with the first half. Conclusion: The present findings provide evidence that vibratory stimuli may trigger a centrally-mediated mechanism that contributes to the generation of extra torques. The vibration-induced increased motoneuron excitability (leading to increased torque generation) presumably activates spinal motoneurons following the size principle, which is a desirable feature for stimulation paradigms involved in rehabilitation programs and exercise training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Demonstrar os achados em ressonância magnética (RM) da tromboflebite plantar. MÉTODOS: Revisão retrospectiva de 20 pacientes com dor na região plantar nos quais os achados de ressonância magnética indicaram tromboflebite plantar. RESULTADOS: Foram avaliados 14 homens e seis mulheres, com idade média de 46,7 anos. Oito desses pacientes também foram submetidos à ultrassonografia com doppler, que confirmaram a tromboflebite. As imagens de ressonância magnética foram avaliadas em consenso por dois radiologistas com experiência em radiologia do sistema musculoesquelético (mais de 10 anos cada um), demonstrando edema perivascular em todos os 20 pacientes (100%) e edema muscular em 19 dos 20 pacientes (95%). Todos os 20 pacientes apresentavam intensidade de sinal intermediária intraluminal em T2 (100%) e ectasia venosa estava presente em 17 dos 20 casos (85%). Veias colaterais foram visualizadas em um dos 20 pacientes (5%). Todos os 14 casos (100%), nos quais o contraste intravenoso foi administrado, apresentavam realce dos tecidos perivenulares e defeito de enchimento intraluminal. Ectasia venosa, perda da compressibilidade e ausência de fluxo na ultrassonografia com doppler também foram observados em todos os oito casos examinados pelo método. CONCLUSÕES: A RM é um método sensível na avaliação de tromboflebite plantar em pacientes com dor plantar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi investigar a influência da obesidade e da força de preensão palmar (FPP) no equilíbrio postural estático de idosas ativas nas condições de olhos abertos e fechados. Participaram 31 idosas (16 eutróficas e 15 obesas). A idade média e o Índice de Massa Corpórea (IMC) das eutróficas foram, respectivamente, 68,3±2,7 anos e 23,4±1,6kg/m², e das obesas 69,1±2,7 anos e 33,5±3kg/m². A FPP foi avaliada usando um dinamômetro (JAMAR). O equilíbrio postural estático foi avaliado usando um sistema tridimensional nas condições de olhos abertos (OA) e fechados (OF), durante 90 segundos cada condição. A FPP das idosas eutróficas foi 25,1±4,6kgf e das obesas foi 24,8±5,2kgf, não havendo diferenças significativas. No equilíbrio postural, foram observadas diferenças significativas entre os grupos apenas no deslocamento máximo a-p com AO (p=0,04) e OF (p<0,01), com as idosas obesas apresentando menor deslocamento a-p em relação às eutróficas. Não houve correlação entre o deslocamento máximo a-p com IMC e a FPP. No presente estudo FPP não influenciou o equilíbrio postural estático, enquanto a obesidade foi fator determinante de menor deslocamento ântero-posterior de idosas ativas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES] En este artículo se presenta un sistema novedoso para la autenticación automática de personas basado en un indicador biométrico de la mano: la huella de la región dígito palmar. La imagen de los pliegues de la base del dedo índice se ha tomado con una cámara digital comercial. Dichas imágenes han sido digitalmente procesadas con el fin de realzar las colinas y valles de los pliegues de la piel. Estas líneas son seguidas para establecer los puntos de bifurcación y término denominados minucias, los cuales forman el descriptor de la huella dígito palmar. Un clasificador basado en un umbral y el coeficiente de correlación de Pearson verifica si una nueva huella pertenece a la identidad reclamada. Los resultados obtenidos muestran una confianza superior al 98% trabajando con 38 personas entre las cuales se incluyen huellas de baja calidad.