176 resultados para Bráquetes ortodônticos
Resumo:
This study evaluated the maxillary transversal changes caused by the rapid maxillary expansion (RME) accomplished by Hyrax appliance. Sixteen children from both genders were selected and treated, with ages between 7.7 to 10.8 years, who presented unilateral or bilateral posterior crossbite. Postero-anterior radiographs were taken at the beginning of the treatment, end and post-retention period. The treatment promoted an average opening of 8.8 mm of IMD (intermolar distance), 2.33 mm of IAD (interapex distance) and none of IID (interincisal distance). At the end of retention period, relapse was observed, with a decrease of 4.3 mm of IMD, 1.23 mm of IAD, a non-significant enlargement of IID (0,38 mm).These results confirm the significant influence of Hyrax appliance on transverse dimensions, represented by enlargement of IMD and IAD and its effectiveness to solve posterior crossbites.
Resumo:
The increased interest in orthodontics by adults has led companies to develop new treatment alternatives that use less visible and more aesthetic orthodontic appliances. The aesthetic aligners stand out among the treatment options that attend these expectations. This paper presented some relevant aspects of these devices, as well as two cases treated with Essix MTM (Dentsply) system, in which all aesthetic and functional objectives proposed treatment have been achieved. The results of this study support the idea that, when properly indicated, aesthetic aligners are a viable treatment option within the clinical routine of the orthodontist.
Resumo:
Bite block is a functional orthodontic appliance that promotes relative intrusion or dental eruption inhibition. The purpose of this study is to present the effects of bite block on the treatment of an open bite case report.
Resumo:
Following the introduction of the acid-etching technique in enamel surface, direct attachment of orthodontic appliances on the surface of the tooth and/or restorations became a routine procedure in the assembly of the fixed devices. The attainment of a success result is related to the criterion attention to the details and the steps of the bonding technique, as well as, to the knowledge of the characteristics of the adhesive materials and orthodontic brackets. This paper presents some aspects of various types of brackets and adhesives materials.
Resumo:
Direct bonding of orthodontics attachments to the teeth or restoration has become a routine in fixed appliance therapy. The technique used seems to be simple, but meticulous attention to detail and steps, a thorough understanding of factors involved are needed to ensure a successful outcome into different surfaces. It is the purpose of this article to review concerning aspects to orthodontic bonding in enamel and restorations fabricated from different materials; affording assistance to the reader wiser accomplishment and successful procedure.
Resumo:
Introduction: Ertty System® is an intraoral system of biomechanical forces to move teeth anteroposteriorly. The application of forces on this system results in the distalization of the molar and all lateral segment in the side to be distalized, including premolars and canine, resulting in alveolar bone remodeling. This system is indicated to correct uni- or bilateral maxillary dental Class II malocclusion in permanent dentition both in children and adults. It is contraindicated in case of skeletal asymmetries, protrusion of maxillary and mandibular teeth, skeletal Class II and Class II subdivision malocclusions with mandibular midline deviation. This study describes Ertty System® and presents two clinical cases treated using this system. The two female patients presented with Class II malocclusion subdivision and maxillary midline deviation. Results: It was achieved correct alignment and leveling, Class I dental relation and correction of upper midline. Conclusion: The success and stability of results confirmed diagnosis and treatment adequacy.
Resumo:
In recent years the number of adult Patients who seek esthetic treatments has increased. Among the patients main concern, lip augmentation has increased, and this procedure has been very well performed and studied by dermatologists and plastic surgeons. Although Orthodontics can achieve good esthetic results through teeth and jaw proper positioning it is a time consuming approach and it discloses some anatomical and biological limitations. Dermatology may be an excellent alternative to enhance orthodontic results through lip augmentation. The aim of this paper is to discuss some dermatology techniques currently available to augment the lips as well as describe a case report highlighting the need for interdisciplinary approach to enhance facial esthetics goals.
Resumo:
Introduction: The orthodontic treatment using lingual brackets has been desired by adult patients for esthetic factors. In this paper it is described the clinical steps of an orthodontic treatment using Incognito™ system, individualized lingual brackets and archwires designed by CAD/CAM technology. Methods: The presented case describes the treatment of a patient with mesofacial growth pattern,Class I malocclusion, with mandibular crowding and diastema between the upper central incisors, treated using 100% individualized lingual brackets. Results: After treatment, the molar relation of Class I was kept, the spaces between upper central incisors were closed and mandibular crowding corrected. Conclusion: This case report demonstrated the efficiency of the new method for lingual orthodontic treatment.
Resumo:
Osteodistraction is a clinical reality, available in the last decades for the resolution of large bone deficiencies, in cases that there are pre-existing, but misplaced implants and teeth. The aims of thearticle is to present a case report in which a new possibility for bone distraction, based on tooth-implant bone distractors, made from standard orthodontic expansion-screws, was used in an area where there was an extensive need of alveolar bone and aesthetical recovery, allied to teeth and dental implant misplacement. This technique presented good clinical results, associated to effective simplicity and low cost, becoming viable clinical solution for bone tissue augmentation and aesthetical optimization. In resume, it is possible to say that the suggested technique achieved its objectives, improving the hard and soft tissue profile, whilst allowing completion of oral rehabilitation.
Resumo:
A metal coping may undergo changes during porcelain firing, which compromises its marginal adaptation. The use of NiCrTi alloy proposes to minimize this effect through the high melting point of titanium present in its composition. This study evaluated the influence of porcelain firing cycle on the marginal adaptation of NiCrTi copings in different preparation designs. Forty standardized metal dies were fabricated with the following combinations finish line/convergence of the axial walls: 1) shoulder/6°; 2) shoulder/20°; 3) sloping shoulder/6°; 4) sloping shoulder/20°. On each die a metal ceramic restoration coping was made. The die/coping set was stabilized with orthodontic elastics, divided into four equidistant areas with three measurement points each and a cementation pressure was simulated. The measurements were taken under a stereomicroscope (32×). After the first measurement, the copings were submitted to sintering cycles simulating porcelain application. For repeated measurements, the same procedures described above were performed. Data were submitted to Student’s-t test, 1-way ANOVA and Tukey´s test (α = 0.05). Adaptation means (µm) before and after porcelain firing in different preparations were: 1) 111.92 and 127.31; 2) 124.15 and 135.48; 3) 122.19 and 138.77; 4) 166.09 and 186.72; respectively. The porcelain firing impaired adaptation, regardless of the preparation design. The preparation in a 20° sloping shoulder provided a worse adaptation when compared with preparations that had 6° and 20° shoulder, which were statistically equal. The 6° sloping shoulder was statistically equal to the other three preparation designs.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding) and indirect (IBB - indirect bracket bonding) bracket bonding techniques. The time length of laboratorial (IBB) and clinical steps (DBB and IBB) as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women) with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB). The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001). However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001). There was no significant difference (p = 0.910) for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.
Resumo:
OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n=5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSION: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Since bleaching has become a popular procedure, the effect of peroxides on dental hard tissues is of great interest in research. Purpose: The aim of this in vitro study was to perform a qualitative analysis of the human enamel after the application of in-office bleaching agents, using Scanning Electron Microscopy (SEM). Materials and Methods: Twenty intact human third molars extracted for orthodontic reasons were randomly divided into four groups (n=5) treated as follows: G1- storage in artificial saliva (control group); G2- four 30-minute applications of 35% carbamide peroxide (total exposure: 2h); G3- four 2-hour exposures to 35% carbamide peroxide (total exposure: 8h); G4- two applications of 35% hydrogen peroxide, which was light-activated with halogen lamp at 700mW/cm2 during 7min and remained in contact with enamel for 20min (total exposure: 40min). All bleaching treatments adopted in this study followed the application protocols advised by manufacturers. Evaluation of groups submitted to 35% carbamide peroxide was carried out after two time intervals (30 minutes and 2 hours per session), following the extreme situations recommended by the manufacturer. Specimens were prepared for SEM analysis performing gold sputter coating under vacuum and were examined using 15kV at 500x and 2000x magnification. Results: Morphological alterations on the enamel surface were similarly detected after bleaching with either 35% carbamide peroxide or 35% hydrogen peroxide. Surface porosities were characteristic of an erosive process that took place on human enamel. Depression areas, including the formation of craters, and exposure of enamel rods could also be detected. Conclusion: Bleaching effects on enamel morphology were randomly distributed throughout enamel surface and various degrees of enamel damage could be noticed. Clinical significance: In-office bleaching materials may adversely affect enamel morphology and therefore should be used with caution.