958 resultados para Bland Altman analysis
Resumo:
The purpose of this study was to compare the validity and output of the biaxial ActiGraph GT1M and the triaxial GT3X (ActiGraph, LLC, Pensacola, FL, USA)accelerometer in 5- to 9-year-old children. Thirty-two children wore the two monitors while their energy expenditure was measured with indirect calorimetry. They performed four locomotor and four play activities in an exercise laboratory and were further measured during 12 minutes of a sports lesson. Validity evidence in relation to indirect calorimetry was examined with linear regression equations applied to the laboratory data. During the sports lessons predicted energy expenditure according to the regression equations was compared to measured energy expenditure with the Wilcoxon-signed rank test and the Spearman correlation. To compare the output, agreement between counts of the two monitors during the laboratory activities was assessed with Bland-Altman plots. The evidence of validity was similar for both monitors. Agreement between the output of the two monitors was good for vertical counts (mean bias = −14 ± 22 counts) but not for horizontal counts (−17 ± 32 counts). The current results indicate that the two accelerometer models are able to estimate energy expenditure of a range of physical activities equally well in young children. However, they show output differences for movement in the horizontal direction.
Resumo:
This study aimed to evaluate whether equine serum amyloid A (SAA) concentrations could be reliably measured in plasma with a turbidimetric immunoassay previously validated for equine SAA concentrations in serum. Paired serum and lithium-heparin samples obtained from 40 horses were evaluated. No difference was found in SAA concentrations between serum and plasma using a paired t test (P=0.48). The correlation between paired samples was 0.97 (Spearman's rank P<0.0001; 95% confidence interval 0.95-0.99). Passing-Bablok regression analyses revealed no differences between paired samples. Bland-Altman plots revealed a positive bias in plasma compared to serum but the difference was not considered clinically significant. The results indicate that lithium-heparin plasma samples are suitable for measurement of equine SAA using this method. Use of either serum or plasma allows for greater flexibility when it comes to sample collection although care should be taken when comparing data between measurements from different sample types.
Resumo:
Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right-left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland-Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed.
Resumo:
BACKGROUND Ultrasonographic appearance of the gastrointestinal (GI) tract of equine neonates has not been completely described. OBJECTIVES To describe (1) sonographic characteristics of the GI segments in normal nonsedated equine neonates, (2) intra- and interobserver variation in wall thickness, and (3) the sonographic appearance of asymptomatic intussusceptions, and (4) to compare age and sonographic findings of foals with and without asymptomatic intussusceptions. ANIMALS Eighteen healthy Standardbred foals ≤5 days of age. METHODS Prospective, cross-sectional blinded study. Gastrointestinal sonograms were performed stall-side. Intraobserver variability in wall thickness measurements was determined by calculating the coefficient of variation (CV). The Bland-Altman method was used to assess interobserver bias. Student's t-test and Fisher's exact test were used to test the association among presence of intussusceptions, age, and selected sonographic findings. RESULTS The reference ranges (95% predictive interval) for wall thickness were 1.6-3.6 mm for the stomach, 1.9-3.2 mm for the duodenum, 1.9-3.1 mm for the jejunum, 1.3-2.2 mm for the colon, and 0.8-2.7 mm for the cecum. Intraobserver wall thickness CV ranged from 8 to 21% for the 2 observers for 5 gastrointestinal segments. The interobserver bias for wall thickness measurements was not significant except for the stomach (0.14 mm, P < .05) and duodenum (0.29 mm, P < .05). Diagnostic images of mural blood flow could not be obtained. Asymptomatic intussusceptions were found in 10/18 neonates. Associations between sonographic variables or age and the presence of intussusceptions were not found. CONCLUSIONS AND CLINICAL IMPORTANCE Sonographic characteristics of the GI tract of normal Standardbred neonates can be useful in evaluating ill foals. Asymptomatic small intestinal intussusceptions occur in normal Standardbred neonates.
Resumo:
OBJECTIVES
To test the applicability, accuracy, precision, and reproducibility of various 3D superimposition techniques for radiographic data, transformed to triangulated surface data.
METHODS
Five superimposition techniques (3P: three-point registration; AC: anterior cranial base; AC + F: anterior cranial base + foramen magnum; BZ: both zygomatic arches; 1Z: one zygomatic arch) were tested using eight pairs of pre-existing CT data (pre- and post-treatment). These were obtained from non-growing orthodontic patients treated with rapid maxillary expansion. All datasets were superimposed by three operators independently, who repeated the whole procedure one month later. Accuracy was assessed by the distance (D) between superimposed datasets on three form-stable anatomical areas, located on the anterior cranial base and the foramen magnum. Precision and reproducibility were assessed using the distances between models at four specific landmarks. Non parametric multivariate models and Bland-Altman difference plots were used for analyses.
RESULTS
There was no difference among operators or between time points on the accuracy of each superimposition technique (p>0.05). The AC + F technique was the most accurate (D<0.17 mm), as expected, followed by AC and BZ superimpositions that presented similar level of accuracy (D<0.5 mm). 3P and 1Z were the least accurate superimpositions (0.79
Resumo:
The use of the SenseWear™ armband (SWA), an objective monitor of physical activity, is a relatively new device used by researchers to measure energy expenditure. These monitors are practical, relatively inexpensive and easy-to-use. The aim of the present study was to assess the validity of SWAs for the measurement of energy expenditure (EE) in circuit resistance training (CRT) at three different intensities in moderately active, healthy subjects. The study subjects (17 females, 12 males) undertook CRT at 30, 50 and 70% of the 15 repetition maximum for each exercise component wearing an SWA as well as an Oxycon Mobile (OM) portable metabolic system (a gold standard method for measuring EE). The EE rose as exercise intensity increased, but was underestimated by the SWAs. For women, Bland-Altman plots showed a bias of 1.13 ± 1.48 METs and 32.1 ± 34.0 kcal in favour of the OM system, while for men values of 2.33 ± 1.82 METs and 75.8 ± 50.8 kcal were recorded.
Resumo:
O trabalho que se apresenta nesta dissertação pretende ser uma contribuição para o desenvolvimento de métodos de avaliação da recuperação da marcha em pacientes pós acidente vascular cerebral (AVC), envolvidos em programas de reabilitação e que sejam utilizadores de ortóteses tornozelo-pé (AFO – Ankle Foot Orthosis). A metodologia desenvolvida considera uma AFO em polipropileno (PP), que é instrumentada com uma unidade de medição inercial (UMI) e oito extensómetros elétricos de resistência. A UMI é fixa com uma tira elástica na posição do retro pé. Os dados recolhidos a partir da instrumentação são utilizados para monitorizar a marcha de doentes pós AVC, a partir do qual podem ser estimados diversos parâmetros espácio-temporais. Os sinais recolhidos nos extensómetros permitem a identificação dos eventos da marcha, necessários para a segmentação do sinal da aceleração, enquanto o sinal da aceleração do eixo horizontal da UMI, no plano sagital, garante a identificação da velocidade da marcha, tempo de apoio e comprimento do ciclo da marcha. Nos testes ao método desenvolvido foram utilizados dois voluntários: um indivíduo saudável e um paciente em recuperação pós AVC, tendo sido definido um protocolo de marcha com dez metros (10 MWT). Os dados recolhidos no indivíduo saudável foram enquadrados no padrão de referência. O paciente executou o protocolo antes e após tratamento com toxina botulínica (TB). Este estudo propõe a definição de um novo parâmetro, o índice de confiança ic, que avalia a confiança do sujeito espástico durante a marcha, com base na transferência do centro da gravidade do corpo na fase do balanço. O método Bland –Altman foi aplicado para validar o método da UMI de medição da velocidade de marcha, comparando com um método de referencia que utiliza medição temporal com cronómetro. A média das diferenças entre os dois métodos foi determinada junto aos limites de concordância. O t Student test permitiu a validação dos dados utilizados no cálculo do índice de confiança. A correlação forte entre as velocidades da marcha e os tempos de apoio e a cadência, fortalece a confiabilidade dos dados obtidos e dos parâmetros calculados utilizando os métodos desenvolvidos neste trabalho. Os resultados obtidos com a metodologia desenvolvida, que apresenta uma estratégia inovadora que recorre aos ângulos da orientação de uma UMI no plano sagital mostraram que é possível monitorizar a evolução dos doentes pós-AVC com recurso a uma AFO.
Resumo:
This study aimed to determine the accuracy (and usability) of the Retinomax, a hand-held autorefractor, compared to measurements taken from hand-held retinoscopy (HHR) in a sample of normal 1-year-old children. The study was a method comparison set at four Community Child Health Clinics. Infants (n = 2079) of approximately 1 year of age were identified from birth/immunization records and their caregivers were contacted by mail. A total of 327 infants ranging in age from 46 weeks to 81 weeks (mean 61 weeks) participated in the study. The children underwent a full ophthalmic examination. Under cycloplegia, refraction was measured in each eye by streak retinoscopy (HHR) and then re-measured using the Retinomax autorefractor. Sphere, cylinder, axis of cylinder and spherical equivalent measurements were recorded for HHR and Retinomax instruments, and compared. Across the range of refractive errors measured, there was generally close agreement between the two examination methods, although the Retinomax consistently read around 0.3 D less hyperopic than HHR. Significantly more girls (72 infants, 47.7%), struggled during examination with the Retinomax than boys (52 infants, 29.5%) (P < 0.001). Agreement deteriorated between the two instruments if the patient struggled during the examination (P < 0.001). In general, the Retinomax would appear to be a useful screening instrument in early childhood. However, patient cooperation affects the accuracy of results and is an important con-sideration in determining whether this screening instrument should be adopted for measuring refractive errors in early infancy.
Resumo:
Purpose: This study was conducted to examine the test-retest reliability of a measure of prediagnosis physical activity participation administered to colorecial cancer survivors recruited from a population-based state cancer registry. Methods: A total of 112 participants completed two telephone interviews. I month apart, reporting usual weekly physical activity in the year before their cancer diagnosis. Intraclass correlation coefficients (ICC) and standard en-or of measurement (SEM) were used to describe the test-retest reliability of the measure across the sample: the Bland-Altman approach was used to describe reliability at the individual level. The test-retest reliability for categorized total physical activity (active, insufficiently active, sedentary) was assessed using the kappa statistic. Results: When the complete sample was considered, the ICC ranged from 0.40 (95% Cl: 0.24, 0.55) for vigorous gardening to 0.77 (95% Cl: 0.68, 0.84) for moderate physical activity. The SEM, however, were large. indicating high measurement error. The Bland-Altman plots indicated that the reproducibility of data decreases as the aniount of physical activity reported each week increases The kappa coefficient for the categorized data was 0.62 (95% Cl: 0.48, 0.76). Conclusion: Overall. the results indicated low levels of repeatability for this measure of historical physical activity. Categorizing participants as active, insufficiently active, or sedentary provides a higher level of test-retest reliability.
Resumo:
Purpose. The purpose of the study was to examine Jamaican adolescents in a school setting, for risk factors of type 2 diabetes mellitus (T2DM) and cardiovascular diseases (CVDs). Methods. A descriptive epidemiological cross-sectional study of 276 Jamaican adolescents (112 males and 164 females) ages 14-19 years (15.6±1.2), randomly selected from grades 9-12 from ten high schools on the island. Thirteen risk factors were examined. Risk factors were compared with BMI levels and demographics. A sub-study validated finger prick testing of fasting blood glucose, total cholesterol, and HbA1c versus venous testing in 59 subjects. Results. Prevalence of overweight was 33.0% (n=91) with mean BMI of 23.74±7.74. Approximately 66.7% of subjects reported ≥ 3 risk factors. The number of T2DM and CVDs risk factors increased for subjects with BMI above 25. One third of the overweight subjects were classified with the metabolic syndrome. High BMI was associated with high waist circumference (r = .767, p < .01), high waist-to-hip ratio (r = .180, p < .01), presence of Acanthosis Nigricans (r = .657, p < .01), high total cholesterol (r = .158, p < .01), family history of T2DM (r = .157, p < .01), and hypertension (r = .422, p < .01). Regression analyses significantly predicted gender and physical activity (p < .001), and total number of risk factors for T2DM and CVDs (p < .001). Paired samples t-tests revealed no significant differences between methods of testing for TC and HbA1c (p < .01) but not for FBG (p > .05). Percentage bias for the methods of blood testing met the reference standards for fasting blood glucose but not for total cholesterol and HbA1c. Bland Altman tests of agreement between the two methods indicated good agreement for all three tests. Conclusion. Jamaican adolescents are at high risk for T2DM and CVDs as seen in other study populations. Effective programs to prevent T2DM and CVDs are needed. Family history of diseases, anthropometric measures, and gender identified more subjects at risk than did the biochemical measures. Comparison between finger prick and venous blood methods suggested that finger prick is an adequate method to screen for risk factors in children and adolescents.
Resumo:
Purpose: The purpose of the study was to examine Jamaican adolescents in a school setting, for risk factors of type 2 diabetes mellitus (T2DM) and cardiovascular diseases (CVDs). Methods: A descriptive epidemiological cross-sectional study of 276 Jamaican adolescents (112 males and 164 females) ages 14-19 years (15.6±1.2), randomly selected from grades 9-12 from ten high schools on the island. Thirteen risk factors were examined. Risk factors were compared with BMI levels and demographics. A sub-study validated finger prick testing of fasting blood glucose, total cholesterol, and HbAlc versus venous testing in 59 subjects. Results: Prevalence of overweight was 33.0% (n=91) with mean BMI of 23.74±7.74. Approximately 66.7% of subjects reported > 3 risk factors. The number of T2DM and CVDs risk factors increased for subjects with BMI above 25. One third of the overweight subjects were classified with the metabolic syndrome. High BMI was associated with high waist circumference (r =.767, p (r = .180, p.05). Percentage bias for the methods of blood testing met the reference standards for fasting blood glucose but not for total cholesterol and HbAlc. Bland Altman tests of agreement between the two methods indicated good agreement for all three tests. Conclusion: Jamaican adolescents are at high risk for T2DM and CVDs as seen in other study populations. Effective programs to prevent T2DM and CVDs are needed. Family history of diseases, anthropometric measures, and gender identified more subjects at risk than did the biochemical measures. Comparison between finger prick and venous blood methods suggested that finger prick is an adequate method to screen for risk factors in children and adolescents.
Resumo:
Objetivo: Traduzir e avaliar as propriedades psicométricas do Mobility Assessment Tool Physical Activity (MAT-PA) em idosos comunitários brasileiros. Métodos: Trata-se de um estudo tradução, adaptação cultural, e acurácia do instrumento MAT-PA, no qual foram avaliados 329 idosos, com idade mínima de 60 anos, residentes na comunidade. Os indivíduos submeteram-se a um formulário de avaliação composto por: questionário sócio-demográfico e de saúde percebida; avaliação física; Prova Cognitiva de Leganés (PCL); Center for Epidemiologic Studies Depression Scale (CES-D); International Physical Activity Questionnaire (IPAQ); Mobility Assessment Tool Physical Activity (MAT-PA). Dessa amostra total, 42 idosos utilizaram o acelerômetro durante 8 dias. Para verificar a confiabilidade teste-reteste do MAT-PA, reaplicou-se esse instrumento em 34 idosos 8 dias após a primeira avaliação. A análise estatística utilizada foi a correlação de Spearman, o Coeficiente de Correlação Intra-classe, o coeficiente α de Cronbach, o Bland-Altman e o teste T pareado. Resultados: As correlações dos dados IPAQ e acelerômetro versus o escore total do MAT-PA foram significativas e apresentaram um coeficiente de correlação de Spearman de 0,13 e 0,41, respectivamente. Analisou-se também a confiabilidade que apresentou as seguintes medidas: consistência interna, pelo coeficiente alfa de Cronbach (α= 0,70); Concordância teste-reteste, pelo coeficiente de correlação intra-classe (CCI=0,53; p<0,001). Conclusão: A versão brasileira do Mobility Assessment Tool Physical Activity (MAT-PA) como um instrumento de avaliação da atividade física de idosos, mostrou ser um método válido e confiável.
Resumo:
Objectives: To measure the step-count accuracy of an ankle-worn accelerometer, a thigh-worn accelerometer and one pedometer in older and frail inpatients. Design: Cross-sectional design study. Setting: Research room within a hospital. Participants: Convenience sample of inpatients aged ≥65 years, able to walk 20 metres unassisted, with or without a walking-aid. Intervention: Patients completed a 40-minute programme of predetermined tasks while wearing the three motion sensors simultaneously. Video-recording of the procedure provided the criterion measurement of step-count. Main Outcome Measures: Mean percentage (%) errors were calculated for all tasks, slow versus fast walkers, independent versus walking-aid-users, and over shorter versus longer distances. The Intra-class Correlation was calculated and accuracy was visually displayed by Bland-Altman plots. Results: Thirty-two patients (78.1 ±7.8 years) completed the study. Fifteen were female and 17 used walking-aids. Their median speed was 0.46 m/sec (interquartile range, IQR 0.36-0.66). The ankle-worn accelerometer overestimated steps (median 1% error, IQR -3 to 13). The other motion sensors underestimated steps (40% error (IQR -51 to -35) and 38% (IQR -93 to -27), respectively). The ankle-worn accelerometer proved more accurate over longer distances (3% error, IQR 0 to 9), than shorter distances (10%, IQR -23 to 9). Conclusions: The ankle-worn accelerometer gave the most accurate step-count measurement and was most accurate over longer distances. Neither of the other motion sensors had acceptable margins of error.
Resumo:
BACKGROUND: The recently developed Context Assessment for Community Health (COACH) tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources, community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment) through 49 items. OBJECTIVE: The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. DESIGNS: To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test-retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC) and percent agreement) and dimensions (ICC and Bland-Altman plots). RESULTS: In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test-retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5-0.7), demonstrating that the instrument has an acceptable level of stability. CONCLUSIONS: This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify some items and to further review items with low ICC.
Resumo:
Thesis (Master's)--University of Washington, 2016-08