952 resultados para Apparent and partial molar volume


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is compelling evidence that Planet Earth is on the path to an era of global warming that has serious implications for the well-being of both people and nature. This three-volume synthesis of literature will be a marvelous place for both the public and new scholars interested in global warming to begin their pursuit of the subject. The author captures the best of the scientific literature and press materials appearing in recent years. The utility of these volumes as a resource for gaining a broad background or pursuing a particular aspect of global warming is enhanced by Johansen's talent for explaining with clarity a vast and rapidly growing subject.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is a continuation of Dokuchaev and Novikov (2010) [8]. The interaction between partial projective representations and twisted partial actions of groups considered in Dokuchaev and Novikov (2010) [8] is treated now in a categorical language. In the case of a finite group G, a structural result on the domains of factor sets of partial projective representations of G is obtained in terms of elementary partial actions. For arbitrary G we study the component pM'(G) of totally-defined factor sets in the partial Schur multiplier pM(G) using the structure of Exel's semigroup. A complete characterization of the elements of pM'(G) is obtained for algebraically closed fields. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] Erythropoietin (Epo) has been suggested to affect plasma volume, and would thereby possess a mechanism apart from erythropoiesis to increase arterial oxygen content. This, and potential underlying mechanisms, were tested in eight healthy subjects receiving 5000 IU recombinant human Epo (rHuEpo) for 15 weeks at a dose frequency aimed to increase and maintain haematocrit at approximately 50%. Red blood cell volume was increased from 2933 +/- 402 ml before rHuEpo treatment to 3210 +/- 356 (P < 0.01), 3117 +/- 554 (P < 0.05), and 3172 +/- 561 ml (P < 0.01) after 5, 11 and 13 weeks, respectively. This was accompanied by a decrease in plasma volume from 3645 +/- 538 ml before rHuEpo treatment to 3267 +/- 333 (P < 0.01), 3119 +/- 499 (P < 0.05), and 3323 +/- 521 ml (P < 0.01) after 5, 11 and 13 weeks, respectively. Concomitantly, plasma renin activity and aldosterone concentration were reduced. This maintained blood volume relatively unchanged, with a slight transient decrease at week 11, such that blood volume was 6578 +/- 839 ml before rHuEpo treatment, and 6477 +/- 573 (NS), 6236 +/- 908 (P < 0.05), and 6495 +/- 935 ml (NS), after 5, 11 and 13 weeks of treatment. We conclude that Epo treatment in healthy humans induces an elevation in haemoglobin concentration by two mechanisms: (i) an increase in red cell volume; and (ii) a decrease in plasma volume, which is probably mediated by a downregulation of the rennin-angiotensin-aldosterone axis. Since the relative contribution of plasma volume changes to the increments in arterial oxygen content was between 37.9 and 53.9% during the study period, this mechanism seems as important for increasing arterial oxygen content as the well-known erythropoietic effect of Epo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] In this work, we present a new model for a dense disparity estimation and the 3-D geometry reconstruction using a color image stereo pair. First, we present a brief introduction to the 3-D Geometry of a camera system. Next, we propose a new model for the disparity estimation based on an energy functional. We look for the local minima of the energy using the associate Euler-Langrage partial differential equations. This model is a generalization to color image of the model developed in, with some changes in the strategy to avoid the irrelevant local minima. We present some numerical experiences of 3-D reconstruction, using this method some real stereo pairs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Questo scritto mira a fare una panoramica dei problemi legati alla sicurezza della comunicazione tra componenti interne dei veicoli e delle soluzioni oggigiorno disponibili. Partendo con una descrizione generale del circuito interno dell’auto analizzeremo i suoi punti di accesso e discuteremo i danni prodotti dalla sua manomissione illecita. In seguito vedremo se ´è possibile prevenire tali attacchi dando un’occhiata alle soluzioni disponibili e soffermandoci in particolare sui moduli crittografici e le loro applicazioni. Infine presenteremo l’implementazione pratica di un protocollo di autenticazione tra ECUs e una dimostrazione matematica della sua sicurezza.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the changes in inclination of the maxillary second (M2) and third (M3) molars after orthodontic treatment of Class II Division 1 malocclusion with extraction of maxillary first molars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical examination, skin biopsies, skull radiographs, and DNA analysis of a 2-day-old Red Angus-Charolais-Simmental cross bull calf confirmed the diagnosis of congenital hypotrichosis and anodontia defect (HAD), also called anhidrotic ectodermal dysplasia, which is a rare anomaly caused by a deletion in the bovine EDA gene on the X chromosome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Insufficient blood flow and oxygenation in the intestinal tract is associated with increased incidence of postoperative complications after bowel surgery. High fluid volume administration may prevent occult regional hypoperfusion and intestinal tissue hypoxia. We tested the hypothesis that high intraoperative fluid volume administration increases intestinal wall tissue oxygen pressure during laparotomy. METHODS: In all, 27 pigs were anaesthetized, ventilated and randomly assigned to one of the three treatment groups (n = 9 in each) receiving low (3 mL kg-1 h-1), medium (7 mL kg-1 h-1) or high (20 mL kg-1 h-1) fluid volume treatment with lactated Ringer's solution. All animals received 30% and 100% inspired oxygen in random order. Cardiac index was measured with thermodilution and tissue oxygen pressure with a micro-oximetry system in the jejunum and colon wall and subcutaneous tissue. RESULTS: Groups receiving low and medium fluid volume treatment had similar systemic haemodynamics. The high fluid volume group had significantly higher mean arterial pressure, cardiac index and subcutaneous tissue oxygenation. Tissue oxygen pressures in the jejunum and colon were comparable in all three groups. CONCLUSIONS: The three different fluid volume regimens tested did not affect tissue oxygen pressure in the jejunum and colon, suggesting efficient autoregulation of intestinal blood flow in healthy subjects undergoing uncomplicated abdominal surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: It has been suggested that infants dynamically regulate their tidal flow and end-expiratory volume level. The interaction between muscle activity, flow and lung volume in spontaneously sleeping neonates is poorly studied, since it requires the assessment of transcutaneous electromyography of respiratory muscles (rEMG) in matched comparison to lung function measurements. METHODS: After determining feasibility and repeatability of rEMG in 20 spontaneously sleeping healthy neonates, we measured the relative impact of intercostal and diaphragmatic EMG activity in direct comparison to the resulting tidal flow and FRC. RESULTS: We found good feasibility, repeatability and correlation of timing indices between rEMG activity and flow. The rEMG amplitude was significantly dependent on the resistive load of the face mask. Diaphragm and intercostal muscle activity commenced prior to the onset of flow and remained active during the expiratory cycle. The relative contribution of intercostal and diaphragmatic activity to flow was variable and changed dynamically. CONCLUSION: Using matched rEMG, air flow and lung volume measurements, we have found good feasibility and repeatability of intercostal and diaphragm rEMG measurements and provide the first quantitative measures of the temporal relationship between muscle activity and flow in spontaneously sleeping healthy neonates. Lung mechanical function is dynamically regulated and adapts on a breath to breath basis. So, non-invasive rEMG measurements alone or in combination with lung function might provide a more comprehensive picture of pulmonary mechanics in future studies. The data describing the timing of EMG and flow may be important for future studies of EMG triggered mechanical ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The detection rate of pulmonary emboli (PE) with computed tomography angiography (CTA) using either a standard or a low-dose protocol, combining reduced radiation exposure and iodine delivery rate, was retrospectively analyzed in a matched cohort of 120 patients.