944 resultados para Aortic ring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE/BACKGROUND: The association between socioeconomic status (SES), presentation, and outcome after vascular surgery is largely unknown. This study aimed to determine the influence of SES on post-operative survival and severity of disease at presentation among vascular surgery patients in the Dutch setting of equal access to and provision of care. METHODS: Patients undergoing surgical treatment for peripheral artery disease (PAD), abdominal aortic aneurysm (AAA), or carotid artery stenosis between January 2003 and December 2011 were retrospectively included. The association between SES, quantified by household income, disease severity at presentation, and survival was studied using logistic and Cox regression analysis adjusted for demographics, and medical and behavioral risk factors. RESULTS: A total of 1,178 patients were included. Low income was associated with worse post-operative survival in the PAD cohort (n = 324, hazard ratio 1.05, 95% confidence interval [CI] 1.00-1.10, per 5,000 Euro decrease) and the AAA cohort (n = 440, quadratic relation, p = .01). AAA patients in the lowest income quartile were more likely to present with a ruptured aneurysm (odds ratio [OR] 2.12, 95% CI 1.08-4.17). Lowest income quartile PAD patients presented more frequently with symptoms of critical limb ischemia, although no significant association could be established (OR 2.02, 95% CI 0.96-4.26). CONCLUSIONS: The increased health hazards observed in this study are caused by patient related factors rather than differences in medical care, considering the equality of care provided by the study setting. Although the exact mechanism driving the association between SES and worse outcome remains elusive, consideration of SES as a risk factor in pre-operative decision making and focus on treatment of known SES related behavioral and psychosocial risk factors may improve the outcome of patients with vascular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evolution of receiver architectures, built in modern CMOS technologies, allows the design of high efficient receivers. A key block in modern receivers is the oscillator. The main objective of this thesis is to design a very low power and low area 8-Phase Ring Oscillator for biomedical applications (ISM and WMTS bands). Oscillators with multiphase outputs and variable duty cycles are required. In this thesis we are focused in 12.5% and 50% duty-cycles approaches. The proposed circuit uses eight inverters in a ring structure, in order to generate the output duty cycle of 50%. The duty cycle of 1/8 is achieved through the combination of the longer duty cycle signals in pairs, using, for this purpose, NAND gates. Since the general application are not only the wireless communications context, as well as industrial, scientific and medical plans, the 8-Phase Oscillator is simulated to be wideband between 100 MHz and 1 GHz, and be able to operate in the ISM bands (447 MHz-930 MHz) and WMTS (600 MHz). The circuit prototype is designed in UMC 130 nm CMOS technology. The maximum value of current drawn from a DC power source of 1.2 V, at a maximum frequency of 930 MHz achieved, is 17.54 mA. After completion of the oscillator layout studied (occupied area is 165 μm x 83 μm). Measurement results confirm the expected operating range from the simulations, and therefore, that the oscillator fulfil effectively the goals initially proposed in order to be used as Local Oscillator in RF Modern Receivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quadrature oscillators are key elements in modern radio frequency (RF) transceivers and very useful nowadays in wireless communications, since they can provide: low quadrature error, low phase-noise, and wide tuning range (useful to cover several bands). RC oscillators can be fully integrated without the need of external components (external high Q-inductors), optimizing area, cost, and power consumption. The conventional structure of ring oscillator offers poor frequency stability and phasenoise, low quality factor (Q), and besides being vulnerable to process, voltage and temperature (PVT) variations, its performance degrades as the frequency of operation increases. This thesis is devoted to quadrature oscillators and presents a detailed comparative study of ring oscillator and shift register (SR) approaches. It is shown that in SRs both phase-noise and phase error are reduced, while ring oscillators have the advantage of occupying less area and less consumption due to the reduced number of components in the circuit. Thus, although ring oscillators are more suitable for biomedical applications, SRs are more appropriate for wireless applications, especially when specification requirements are more stringent and demanding. The first architecture studied consists in a simple CMOS ring oscillator employing an odd number of static single-ended inverters as delay cells. Subsequently, the quadrature 4-stage ring oscillator concept is shown and post-layout simulations are presented. The 3 and 4-phase single-frequency local oscillator (LO) generators employing SRs are presented, the latter with 50% and 25% duty-cycles. The circuits operate at 600 MHz and 900 MHz, and were designed in a 130 nm standard CMOS technology with a voltage supply of 1.2 V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE AND METHODS: Screening for abdominal aortic aneurysms may be useful to decrease mortality related to rupture. We conducted a study to assess the prevalence of abdominal aortic aneurysms in southern Brazil and to define risk factors associated with high prevalence of this disorder. The screening was conducted using abdominal ultrasound. Three groups were studied: Group 1 - cardiology clinic patients; Group 2 - individuals with severe ischemic disease and previous coronary surgery, or important lesions on cardiac catheterism; Group 3 - individuals without cardiac disease selected from the general population. All individuals were male and older than 54 years of age. The ultrasonographic diagnosis of aneurysm was based on an anteroposterior abdominal aorta diameter of 3 cm, or on an abdominal aorta diameter 0.5 cm greater than that of the supra-renal aorta. RESULTS: A total of 2.281 people were screened for abdominal aortic aneurysms in all groups: Group 1 - 768 individuals, Group 2 - 501 individuals, and Group 3 - 1012 individuals. The prevalence of aneurysms was 4.3%, 6.8% and 1.7%, respectively. Age and cigarette smoking were significantly associated with increased prevalence of aneurysms, as was the diagnosis of peripheral artery disease. DISCUSSION: We concluded that screening may be an important tool to prevent the mortality associated with abdominal aortic aneurysms surgery. Additionally, the cost of screening can be decreased if only individuals presenting significant risk factors, such as coronary and peripheral artery disease, smokers and relatives of aneurysm patients, are examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To verify if adaptive left ventricle (LV) characteristics are also present in individuals under 70 years of age with severe aortic stenosis (AS). METHODS: The study comprised 40 consecutive patients under 70 years of age with AS and no associated coronary artery disease, referred for valve surgery. Out of the 40 patients, 22 were men and 18 women, and the mean age was 49.8±14.3 years. Cardiac symptoms, presence of systemic hypertension (SH), functional class according to the New York Heart Association (NYHA), and valve lesion etiology were considered. LV cavity dimensions, ejection fraction (EF), fractional shortening (FS), mass (MS), and relative diastolic thickness (RDT) were examined by Doppler echocardiography. RESULTS: Fourteen (63.6%) men and 11 (61.6%) women were classified as NYHA class III/IV (p=0.70). There was no difference in the frequency of angina, syncope or dyspnea between genders. The incidence of SH was greater in women than in men (10 versus 2, p=0.0044). Women had a smaller LV end-diastolic diameter index (32.1±6.5 x 36.5±5.3mm/m², p=0.027), LV end-systolic diameter index (19.9±5.9 x 26.5±6.4mm/m², p=0.0022) and LV mass index (MS) (211.4±71.1 x 270.9±74.9g/m², p=0.017) when compared with men. EF (66.2±13.4 x 52.0±14.6%, p=0.0032), FS (37.6±10.7 x 27.9±9.6%, p=0.0046) and RDT (0.58±0.22 x 0.44±0.09, p=0.0095) were significantly greater in women than in men. CONCLUSION: It is the patient gender rather than age that influences left ventricular adaptive response to AS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess anatomical characteristics of the aortic valve, so that they may be useful in diagnostic situations and surgical treatment. METHODS: The study analyzed 100 healthy fixed human hearts; 84% of them obtained from males, 61% of them from Caucasian individuals. The ages of the individuals ranged from 9 to 86 years (mean 30±15.5 years). The characteristics assessed related to age, sex, and race were the following: number and height of the cusps, size of the lunulae, internal and external intercommissural distance, position of the coronary ostium in relation to the aortic valve, position of the ventricular septum in relation to the aortic valve, thickness of the cusps. RESULTS: All hearts assessed had a tricuspidal aortic valve. In regard to the height of the cusps and size of the lunula, the left coronary cusp was larger, followed by the right coronary cusp and the noncoronary cusp. The internal and external intercommissural distances had mean values of 24.6±5.7mm and 19.7±7mm, respectively. In regard to the position of the coronary ostia, in one heart two ostia emerged from the left coronary sinus, and in another, the ostium was supracommissural. The mean diameter of the aorta was 21.8±3.6mm, and there were no significant sexual or racial differences, but the diameter increased progressively with the increase in age. The thickness of the cusps did not show any significant difference in the 3 points assessed. CONCLUSION: The aortic valve annulus did not show a perfect circumference, with some variations in the measurements of the annulus, in the cusps and in the relation with the ventricular septum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Anomalous origin of the left coronary artery from the right pulmonary artery (AOLCARPA), is a rare entity that is usually associated with other defects. Of the 20 cases of AOLCARPA reported in the literature, 14 (70%) had associations. We describe four patients with AOLCARPA without associated defects, but with a peculiar intramural aortic trajectory. METHODS: Fifty-five patients with anomalous origin of the left coronary artery were operated upon at INCOR-FMUSP. Four of the patients had the anomalous origin from the right pulmonary artery (RPA) without associated defects but with intramural aortic trajectory. Clinical and laboratory examinations were analyzed, as well as surgical findings. RESULTS: All patients had congestive heart failure (CHF) and 3 also had angina pectoris. Two patients had a murmur of mitral regurgitation, signs of myocardial infarction on the ECG and cardiomegaly. The shortening fraction varied from 9% to 23%. The hemodynamic study confirmed the diagnosis of anomalous origin of the coronary artery, but the intramural trajectory and the origin from the RPA were established only at surgery. In 3 patients, the technique of side-to-side anastomosis was performed with a good outcome. One patient, who underwent end-to-side anastomosis, died 6 months after the surgery. CONCLUSION: Association with other defects usually occurs in the AOLCARPA, and the intramural aortic trajectory is difficult to clinically diagnose but easy to surgically correct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this report we describe the twelveth case in the literature of absence of the aortic valve cusps, associated with hypoplastic left-sided heart syndrome in a neonate. Clinical and hemodynamic conditions in our patient resemble the classical features of this syndrome except for a greater development of the ascending aorta and the left ventricular cavity, due to aortic insufficiency. A patch was unsuccessfully inserted at the aortic annulus to exclude the left ventricle from the circulation. In addition the Norwood operation was performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rare association of pulmonary atresia with an intact septum was diagnosed through echocardiography in a fetus 32 weeks of gestational age. The diagnosis was later confirmed by echocardiography of the newborn infant and further on autopsy. The aortic valve was bicuspid with a pressure gradient of 81mmHg, and the right ventricle was hypoplastic, as were the pulmonary trunk and arteries, and the blood flow was totally dependent on the ductus arteriosus.