914 resultados para Analyses errors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aminocarb is a widely applied carbamate insecticide with action of controlling pests such as Lepidoptera and Coleoptera. In this study, subchronic effects on Wistar rats were investigated using hematological, biochemical, and histological techniques. Rats were exposed orally at sublethal levels of 10, 20, or 40 mg/kg body weight (groups A, B, and C, respectively) for 14 d. Hematological results revealed no statistical differences after 1 d of exposure but significant reduction in white blood cells detected after 7 d of exposure in group C, as well as, in all treated groups after 14 d of exposure. Biochemical data showed a decrease of acetylcholinesterase activity in all groups after 1 d of exposure with a return to normal after 7 and 14 d. Significant increase in alkaline phosphatase activity of rats exposed to aminocarb was noted after 7 d of treatment. The levels of triglycerides were also significantly decreased. The present investigation also showed a significant increase in content of serum urea and creatinine in animals from group A (14 d), and from groups B and C (7 and 14 d). Histological results demonstrated hemorrhagic focus on hepatic and renal parenchyma in all exposed groups. Taken together, the attained results were dose dependent and indicated adverse effects of aminocarb on hepatic and renal functions, as well as on immune responsiveness at sublethal tested doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human mesenchymal stem/stromal cells (MSCs) have received considerable attention in the field of cell-based therapies due to their high differentiation potential and ability to modulate immune responses. However, since these cells can only be isolated in very low quantities, successful realization of these therapies requires MSCs ex-vivo expansion to achieve relevant cell doses. The metabolic activity is one of the parameters often monitored during MSCs cultivation by using expensive multi-analytical methods, some of them time-consuming. The present work evaluates the use of mid-infrared (MIR) spectroscopy, through rapid and economic high-throughput analyses associated to multivariate data analysis, to monitor three different MSCs cultivation runs conducted in spinner flasks, under xeno-free culture conditions, which differ in the type of microcarriers used and the culture feeding strategy applied. After evaluating diverse spectral preprocessing techniques, the optimized partial least square (PLS) regression models based on the MIR spectra to estimate the glucose, lactate and ammonia concentrations yielded high coefficients of determination (R2 ≥ 0.98, ≥0.98, and ≥0.94, respectively) and low prediction errors (RMSECV ≤ 4.7%, ≤4.4% and ≤5.7%, respectively). Besides PLS models valid for specific expansion protocols, a robust model simultaneously valid for the three processes was also built for predicting glucose, lactate and ammonia, yielding a R2 of 0.95, 0.97 and 0.86, and a RMSECV of 0.33, 0.57, and 0.09 mM, respectively. Therefore, MIR spectroscopy combined with multivariate data analysis represents a promising tool for both optimization and control of MSCs expansion processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to evaluate the feasibility of using image-based cytometry (IBC) in the analysis of algal cell quantification and viability, using Pseudokirchneriella subcapitata as a cell model. Cell concentration was determined by IBC to be in a linear range between 1 × 105 and 8 × 106 cells mL−1. Algal viability was defined on the basis that the intact membrane of viable cells excludes the SYTOX Green (SG) probe. The disruption of membrane integrity represents irreversible damage and consequently results in cell death. Using IBC, we were able to successfully discriminate between live (SG-negative cells) and dead algal cells (heat-treated at 65 °C for 60 min; SG-positive cells). The observed viability of algal populations containing different proportions of killed cells was well correlated (R 2 = 0.994) with the theoretical viability. The validation of the use of this technology was carried out by exposing algal cells of P. subcapitata to a copper stress test for 96 h. IBC allowed us to follow the evolution of cell concentration and the viability of copper-exposed algal populations. This technology overcomes several main drawbacks usually associated with microscopy counting, such as labour-intensive experiments, tedious work and lack of the representativeness of the cell counting. In conclusion, IBC allowed a fast and automated determination of the total number of algal cells and allowed us to analyse viability. This technology can provide a useful tool for a wide variety of fields that utilise microalgae, such as the aquatic toxicology and biotechnology fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In health related research it is common to have multiple outcomes of interest in a single study. These outcomes are often analysed separately, ignoring the correlation between them. One would expect that a multivariate approach would be a more efficient alternative to individual analyses of each outcome. Surprisingly, this is not always the case. In this article we discuss different settings of linear models and compare the multivariate and univariate approaches. We show that for linear regression models, the estimates of the regression parameters associated with covariates that are shared across the outcomes are the same for the multivariate and univariate models while for outcome-specific covariates the multivariate model performs better in terms of efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract In a few rare diseases, specialised studies in cerebrospinal fluid (CSF) are required to identify the underlying metabolic disorder. We aimed to explore the possibility of detecting key synaptic proteins in the CSF, in particular dopaminergic and gabaergic, as new procedures that could be useful for both pathophysiological and diagnostic purposes in investigation of inherited disorders of neurotransmission. Dopamine receptor type 2 (D2R), dopamine transporter (DAT) and vesicular monoamine transporter type 2 (VMAT2) were analysed in CSF samplesfrom 30 healthy controls (11 days to 17 years) by western blot analysis. Because VMAT2 was the only protein with intracellular localisation, and in order to compare results, GABA vesicular transporter, which is another intracellular protein, was also studied. Spearman’s correlation and Student’s t tests were applied to compare optical density signals between different proteins. All these synaptic proteins could be easily detected and quantified in the CSF. DAT, D2R and GABA VT expression decrease with age, particularly in the first months of life, reflecting the expected intense synaptic activity and neuronal circuitry formation. A statistically significant relationship was found between D2R and DAT expression, reinforcing the previous evidence of DAT regulation by D2R. To our knowledge, there are no previous studies on human CSF reporting a reliable analysis of these proteins. These kinds of studies could help elucidate new causes of disturbed dopaminergic and gabaergic transmission as well as understanding different responses to L-dopa in inherited disorders affecting dopamine metabolism. Moreover, this approach to synaptic activity in vivo can be extended to different groups of proteins and diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The environmental contamination by geohelminths represents a world public health problem and has been well documented by several authors. However, few papers describe the presence of such contamination in saline soils of coastal beaches. A study was performed on the beaches of the municipality of Santos in the period between May 2004 to April 2005 with the aim of determining the degree of contamination, and the correlation between contamination level and seasonal conditions and characteristics of the environment. Of the 2,520 samples analyzed, 18.2% (458) were contaminated, 32.3% (148) of which were localized in children's recreational areas (playgrounds). The parasite profile found in the analyzed samples indicated the presence of several zoonotic parasites: Ancylostoma larvae (82.5%), Toxocara sp. eggs (59.4%), Ancylostomidae-like eggs (37.1%), coccid oocysts (13.5%), Trichostrongylus sp. eggs and larvae, Ascaris lumbricoides eggs, (11.6%), Entamoeba sp. cysts (10.0%), Strongyloides sp. (4.8%), several free nematoids and some non-identified parasitic structures (3.3%). It was established that the highest frequency of parasitic structures occurred in the months between May and October 2004, and from February to March 2005. An increase in the diversity of parasitic forms was documented in the months between February to December 2004 and from January to April 2005, these periods having the highest rainfall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Engenharia do Ambiente, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissertation submitted to Departamento de Engenharia Electrotécnica of Faculdade de Ciências e Tecnologia of Universidade Nova de Lisboa in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: As Análises Clínicas são um precioso elemento entre os meios complementares de diagnóstico e terapêutica permitindo uma enorme panóplia de informações sobre o estado de saúde de determinado utente. O objetivo do laboratório é fornecer informação analítica sobre as amostras biológicas, sendo esta caracterizada pela sua fiabilidade, relevância e facultada em tempo útil. Assim, tratando-se de saúde, e mediante o propósito do laboratório, é notória a sua importância, bem como, a dos fatores associados para o cumprimento do mesmo. O bom desenrolar do ciclo laboratorial, compreendido pelas fases pré-analítica, analítica e pós-analítica é crucial para que o objetivo do laboratório seja cumprido com rigor e rapidez. O presente trabalho “O Erro na Fase Pré-Analítica: Amostras Não Conformes versus Procedimentos”, enquadrado no mestrado de Qualidade e Organização no Laboratório de Análises Clínicas, pretendeu enfatizar a importância da fase pré- analítica, sendo ela apontada como a primordial em erros que acabam por atrasar a saída de resultados ou por permitir que os mesmos não sejam fidedignos como se deseja, podendo acarretar falsos diagnósticos e decisões clínicas erradas. Esta fase, iniciada no pedido médico e finalizada com a chegada das amostras biológicas ao laboratório está entregue a uma diversidade de procedimentos que acarretam, por si só, uma grande diversidade de intervenientes, para além de uma variabilidade de factores que influenciam a amostra e seus resultados. Estes fatores, que podem alterar de algum modo a “veracidade” dos resultados analíticos, devem ser identificados e tidos em consideração para que estejamos convitos que os resultados auxiliam diagnósticos precisos e uma avaliação correta do estado do utente. As colheitas que por quaisquer divergências não originam amostras que cumpram o objectivo da sua recolha, não estando por isso em conformidade com o pretendido, constituem uma importante fonte de erro para esta fase pré-analítica. Neste estudo foram consultados os dados relativos a amostras de sangue e urina não conformes detetadas no laboratório, em estudo, durante o 1º trimestre de 2012, para permitir conhecer o tipo de falhas que acontecem e a sua frequência. Aos Técnicos de Análises Clínicas, colaboradores do laboratório, foi-lhes pedido que respondessem a um questionário sobre os seus procedimentos quotidianos e constituíssem, assim, a população desta 2ª parte do projeto. Preenchido e devolvido de forma anónima, este questionário pretendeu conhecer os procedimentos na tarefa de executar colheitas e, hipoteticamente, confrontá-los com as amostras não conformes verificadas. No 1ºsemestre de 2012 e num total de 25319 utentes registaram-se 146 colheitas que necessitaram de repetição por se verificarem não conformes. A “amostra não colhida” foi a não conformidade mais frequente (50%) versus a “má identificação” que registou somente 1 acontecimento. Houve ainda não conformidades que não se registaram como “preparação inadequada” e “amostra mal acondicionada”. Os técnicos revelaram-se profissionais competentes, conhecedores das tarefas a desempenhar e preocupados em executá-las com qualidade. Eliminar o erro não estará, seguramente, ao nosso alcance porém admitir a sua presença, detetá-lo e avaliar a sua frequência fará com que possamos diminuir a sua existência e melhorar a qualidade na fase pré-analítica, atribuindo-lhe a relevância que desempenha no processo laboratorial.-----------ABSTRACT:Clinical analyses are a precious element among diagnostic and therapeutic tests as they allow an enormous variety of information on the state of health of a user. The aim of the laboratory is to supply reliable, relevant and timely analytical information on biological samples. In health-related matters, in accordance with the objective of the laboratory, their importance is vital, as is the assurance that all the tools are in place for the fulfillment of its purpose. A good laboratory cycle, which includes the pre-analytical, analytical and post-analytical phases, is crucial in fulfilling the laboratory’s mission rapidly and efficiently. The present work - "Error in the pre-analytical phase: non-compliant samples versus procedures”, as part of the Master’s in Quality and Organization in the Clinical Analyses Laboratory, wishes to emphasize the importance of the pre-analytical phase, as the phase containing most errors which eventually lead to delays in the issue of results, or the one which enables those results not to be as reliable as desired, which can lead to false diagnosis and wrong clinical decisions. This phase, which starts with the medical request and ends with the arrival of the biological samples to the laboratory, entails a variety of procedures, which require the intervention of different players, not to mention a great number of factors, which influence the sample and the results. These factors, capable of somehow altering the “truth” of the analytical results, must be identified and taken into consideration so that we may ensure that the results help to make precise diagnoses and a correct evaluation of the user’s condition. Those collections which, due to any type of differences, do not originate samples capable of fulfilling their purpose, and are therefore not compliant with the objective, constitute an important source of error in this pre-analytical phase. In the present study, we consulted data from non-compliant blood and urine samples, detected at the laboratory during the 1st quarter of 2012, to find out the type of faults that happen and their frequency. The clinical analysis technicians working at the laboratory were asked to fill out a questionnaire regarding their daily procedures, forming in this way the population for this second part of the project. Completed and returned anonymously, this questionnaire intended to investigate the procedures for collections and, hypothetically, confront them with the verified non-compliant samples. In the first semester of 2012, and out of a total of 25319 users, 146 collections had to be repeated due to non-compliance. The “uncollected sample” was the most frequent non-compliance (>50%) versus “incorrect identification” which had only one occurrence. There were also unregistered non-compliance issues such as “inadequate preparation” and “inappropriately packaged sample”. The technicians proved to be competent professionals, with knowledge of the tasks they have to perform and eager to carry them out efficiently. We will certainly not be able to eliminate error, but recognizing its presence, detecting it and evaluating its frequency will help to decrease its occurrence and improve quality in the pre-analytical phase, giving it the relevance it has within the laboratory process.