995 resultados para Ambient air
Resumo:
Context - Correction of voluminous hernias and large abdominal wall defects is a big challenge in surgical practice due to technical difficulties and the high incidence of respiratory and cardiovascular complications. Objectives - To present the authors experience with inducing progressive pneumoperitoneum preoperative to surgical treatment of voluminous hernias of the abdominal wall. Methods - Retrospective study of six patients who presented voluminous hernias of the abdominal wall and were operated after installation of a pneumoperitoneum. The procedure was performed by placing a catheter in the abdominal cavity at the level of the left hypochondrium with ambient air insufflation for 10 to 15 days. Results - Four of the six patients were female and two male. Ages ranged from 42 to 62 years. Hernia duration varied from 5 to 40 years. Four patients had incisional, one umbilical, and one inguinal hernias. Mean pneumoperitoneum time was 11.6 days. There were no complications related to pneumoperitoneum installation and maintenance. All hernias were corrected without technical difficulties. The Lichtenstein technique was used to correct the inguinal hernia, peritoneal aponeurotic transposition for one of the incisional hernias, with the rest corrected using polypropylene mesh. One death and one wall infection were observed post operatively. No recurrences were reported until now, in 4 to 36 months of follow-up. Conclusion - Preoperative progressive pneumoperitoneum is a safe and easy executed procedure, which simplifies surgery and reduces post-operative respiratory and cardiovascular complications. It is indicated for patients with hernias that have lost the right of domain in the abdominal cavity.
Resumo:
Tribocorrosion plays an important role in the lifetime of metallic implants. Once implanted, biomaterials are subjected to micro-movements in aggressive biological fluids. Titanium is widely used as an implant material because it spontaneously forms a compact and protective nanometric thick oxide layer, mainly TiO2, in ambient air. That layer provides good corrosion resistance, and very low toxicity, but its low wear resistance is a concern. In this work, an anodizing treatment was performed on commercial pure titanium to form a homogeneous thick oxide surface layer in order to provide bioactivity and improve the biological, chemical and mechanical properties. Anodizing was performed in an electrolyte containing β-glycerophosphate and calcium acetate. The influence of the calcium acetate content on the tribocorrosion behaviour of the anodized material was studied. The concentration of calcium acetate in the electrolyte was found to largely affect the crystallographic structure of the resulting oxide layer. Better tribocorrosion behaviour was noticed on increasing the calcium acetate concentration. © 2013 IOP Publishing Ltd.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Anestesiologia - FMB
Resumo:
Pós-graduação em Enfermagem (mestrado profissional) - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The classic conservative approach for thermal process design can lead to over-processing, especially for laminar flow, when a significant distribution of temperature and of residence time occurs. In order to optimize quality retention, a more comprehensive model is required. A model comprising differential equations for mass and heat transfer is proposed for the simulation of the continuous thermal processing of a non-Newtonian food in a tubular system. The model takes into account the contribution from heating and cooling sections, the heat exchange with the ambient air and effective diffusion associated with non-ideal laminar flow. The study case of soursop juice processing was used to test the model. Various simulations were performed to evaluate the effect of the model assumptions. An expressive difference in the predicted lethality was observed between the classic approach and the proposed model. The main advantage of the model is its flexibility to represent different aspects with a small computational time, making it suitable for process evaluation and design. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Exergetic analysis can provide useful information as it enables the identification of irreversible phenomena bringing about entropy generation and, therefore, exergy losses (also referred to as irreversibilities). As far as human thermal comfort is concerned, irreversibilities can be evaluated based on parameters related to both the occupant and his surroundings. As an attempt to suggest more insights for the exergetic analysis of thermal comfort, this paper calculates irreversibility rates for a sitting person wearing fairly light clothes and subjected to combinations of ambient air and mean radiant temperatures. The thermodynamic model framework relies on the so-called conceptual energy balance equation together with empirical correlations for invoked thermoregulatory heat transfer rates adapted for a clothed body. Results suggested that a minimum irreversibility rate may exist for particular combinations of the aforesaid surrounding temperatures. By separately considering the contribution of each thermoregulatory mechanism, the total irreversibility rate rendered itself more responsive to either convective or radiative clothing-influenced heat transfers, with exergy losses becoming lower if the body is able to transfer more heat (to the ambient) via convection.
Resumo:
[EN] The principal aim of this investigation was to determine the influence of blood haemoglobin concentration ([Hb]) on maximal exercise capacity and maximal O(2) consumption (V(O(2),max)) in healthy subjects acclimatised to high altitude. Secondarily, we examined the effects of [Hb] on the regulation of cardiac output (CO), blood pressure and muscular blood flow (LBF) during exercise. Eight Danish lowlanders (three females and five males; 24 +/- 0.6 years, mean +/- S.E.M.) performed submaximal and maximal exercise on a cycle ergometer after 9 weeks at an altitude of 5260 m (Mt Chacaltaya, Bolivia). This was done first with the high [Hb] resulting from acclimatisation and again 2-4 days later, 1 h after isovolaemic haemodilution with Dextran 70 to near sea level [Hb]. After measurements at maximal exercise while breathing air at each [Hb], subjects were switched to hyperoxia (55 % O(2) in N(2)) and the measurements were repeated, increasing the work rate as tolerated. Hyperoxia increased maximal power output and leg V(O(2),max), showing that breathing ambient air at 5260 m, V(O(2),max) is limited by the availability of O(2) rather than by muscular oxidative capacity. Altitude increased [Hb] by 36 % from 136 +/- 5 to 185 +/- 5 g l(-1) (P < 0.001), while haemodilution (replacing 1 l of blood with 1 l of 6 % Dextran) lowered [Hb] by 24 % to 142 +/- 6 g l(-1) (P < 0.001). Haemodilution had no effect on maximal pulmonary or leg V(O(2),max), or power output. Despite higher LBF, leg O(2) delivery was reduced and maximal V(O(2)) was thus maintained by higher O(2) extraction. While CO increased linearly with work rate irrespective of [Hb] or inspired oxygen fraction (F(I,O(2))), both LBF and leg vascular conductance were systematically higher when [Hb] was low. Close and significant relationships were seen between LBF (and CO) and both plasma noradrenaline and K(+) concentrations, independently of [Hb] and F(I,O(2)). In summary, under conditions where O(2) supply limits maximal exercise, the increase in [Hb] with altitude acclimatisation does not improve maximal exercise capacity or V(O(2),max), and does not alter peak CO. However, LBF and vascular conductance are higher at altitude when [Hb] is lowered to sea level values, with both relating closely to catecholamine and potassium concentrations. This suggests that the lack of effect of [Hb] on V(O(2),max) may involve reciprocal changes in LBF via local metabolic control of the muscle vasculature.
Resumo:
[EN] 1. One to five weeks of chronic exposure to hypoxia has been shown to reduce peak blood lactate concentration compared to acute exposure to hypoxia during exercise, the high altitude 'lactate paradox'. However, we hypothesize that a sufficiently long exposure to hypoxia would result in a blood lactate and net lactate release from the active leg to an extent similar to that observed in acute hypoxia, independent of work intensity. 2. Six Danish lowlanders (25-26 years) were studied during graded incremental bicycle exercise under four conditions: at sea level breathing either ambient air (0 m normoxia) or a low-oxygen gas mixture (10 % O(2) in N(2), 0 m acute hypoxia) and after 9 weeks of acclimatization to 5260 m breathing either ambient air (5260 m chronic hypoxia) or a normoxic gas mixture (47 % O(2) in N(2), 5260 m acute normoxia). In addition, one-leg knee-extensor exercise was performed during 5260 m chronic hypoxia and 5260 m acute normoxia. 3. During incremental bicycle exercise, the arterial lactate concentrations were similar at sub-maximal work at 0 m acute hypoxia and 5260 m chronic hypoxia but higher compared to both 0 m normoxia and 5260 m acute normoxia. However, peak lactate concentration was similar under all conditions (10.0 +/- 1.3, 10.7 +/- 2.0, 10.9 +/- 2.3 and 11.0 +/- 1.0 mmol l(-1)) at 0 m normoxia, 0 m acute hypoxia, 5260 m chronic hypoxia and 5260 m acute normoxia, respectively. Despite a similar lactate concentration at sub-maximal and maximal workload, the net lactate release from the leg was lower during 0 m acute hypoxia (peak 8.4 +/- 1.6 mmol min(-1)) than at 5260 m chronic hypoxia (peak 12.8 +/- 2.2 mmol min(-1)). The same was observed for 0 m normoxia (peak 8.9 +/- 2.0 mmol min(-1)) compared to 5260 m acute normoxia (peak 12.6 +/- 3.6 mmol min(-1)). Exercise after acclimatization with a small muscle mass (one-leg knee-extensor) elicited similar lactate concentrations (peak 4.4 +/- 0.2 vs. 3.9 +/- 0.3 mmol l(-1)) and net lactate release (peak 16.4 +/- 1.8 vs. 14.3 mmol l(-1)) from the active leg at 5260 m chronic hypoxia and 5260 m acute normoxia. 4. In conclusion, in lowlanders acclimatized for 9 weeks to an altitude of 5260 m, the arterial lactate concentration was similar at 0 m acute hypoxia and 5260 m chronic hypoxia. The net lactate release from the active leg was higher at 5260 m chronic hypoxia compared to 0 m acute hypoxia, implying an enhanced lactate utilization with prolonged acclimatization to altitude. The present study clearly shows the absence of a lactate paradox in lowlanders sufficiently acclimatized to altitude.