883 resultados para Air quality management.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quality related problems have become dominant in the seafood processing industry in Kerala. This has resulted in the rejection of seafood sent from India to many destinations. The latest being the total block listing of seafood companies from India from being exported to Europe and partial block listing by the US. The quality systems prevailed in the seafood industry in India were outdated and no longer in use in the developed world. According to EC Directive discussed above all the seafood factories exporting to European countries have to adopt HACCP. Based on this, EIA has now made HACCP system mandatory in all the seafood processing factories in India. This transformation from a traditional product based inspection system to a process control system requires thorough changes in the various stages of production and quality management. This study is conducted by the author with to study the status of the existing infrastructure and quality control system in the seafood industry in Kerala with reference to the recent developments in the quality concepts in international markets and study the drawbacks, if any, of the existing quality management systems in force in the seafood factories in Kerala for introducing the mandatory HACCP concept. To assess the possibilities of introducing Total Quality Management system in the seafood industry in Kerala in order to effectively adopt the HACCP concept. This is also aimed at improving the quality of the products and productivity of the industry by sustaining the world markets in the long run.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Health is an important aspect of everybody’s life. Today, there is an increasing recognition and commitment to the pursuit of health both within government and beyond. Any attempt on the part of the " State to protect and promote people’s health, in turn, must be accompanied by effective controls on air quality, as air constitutes ‘ one of the important elements of man’s life and the consequences of air pollution covers a very wide spectrum ranging from material ---damage to personal discomfort and illness. The broad social and economic objectives adumbrated in the Directive Principles of State Policy including the commitment to improve public health underlying in Article 47 and the obligation to preserve and protect-the natural environment cast under Article 48A of the Constitution are being used as versatile weapons by the State to regulate the public health scenario. Preservation and maintenance of air quality is a significant area within the sphere of public health, where the regulatory arm of the law is not adequately touched and in this arena urgent State intervention through legislative and administrative action is called for in the well-being of the society. Judiciary also plays a pivotal role in this arena in the larger interest of the society and for the benefit of the present and future generations. The research study is an attempt to analyze how far the existing legal system, for maintaining air quality and in controlling air pollution, is effective in protecting public health. The study also analyzes the limitations of the control mechanisms. The study focuses on industrial air pollution, indoor and personal air pollution, vehicular pollution and noise pollution which are today appearing as the major public health hazards affecting the air quality. However, this is not to overlook the importance of controls required under other areas of public health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: Quality Management is an essential part of successful organisations. But the effect of it is mostly not directly visible. The effects are more indirect, and have a time lag till results appear. In today’s challenging times, all activities of an organisation have to proof their ability to add value. While Value Based Management is more focussed on financial value, other concepts and models like EFQM Excellence Model and Kaplan and Norton’s Balanced Score Card also point on values that are the basis and driver for financial success. Quality Management has to proof its effects on company values, and therefore the transacting mechanisms have to be identified and procedure to manage the process of Value Adding Quality Management has to be developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Monitor a distribution network implies working with a huge amount of data coining from the different elements that interact in the network. This paper presents a visualization tool that simplifies the task of searching the database for useful information applicable to fault management or preventive maintenance of the network

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With both climate change and air quality on political and social agendas from local to global scale, the links between these hitherto separate fields are becoming more apparent. Black carbon, largely from combustion processes, scatters and absorbs incoming solar radiation, contributes to poor air quality and induces respiratory and cardiovascular problems. Uncertainties in the amount, location, size and shape of atmospheric black carbon cause large uncertainty in both climate change estimates and toxicology studies alike. Increased research has led to new effects and areas of uncertainty being uncovered. Here we draw together recent results and explore the increasing opportunities for synergistic research that will lead to improved confidence in the impact of black carbon on climate change, air quality and human health. Topics of mutual interest include better information on spatial distribution, size, mixing state and measuring and monitoring. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. II, Reading, UK, 2000. p. 1013-18; [13] Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In designing modern office buildings, building spaces are frequently zoned by introducing internal partitioning, which may have a significant influence on the room air environment. This internal partitioning was studied by means of model test, numerical simulation, and statistical analysis as the final stage. In this paper, the results produced from the statistical analysis are summarized and presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The internal partitioning, which is frequently introduced in open-space planning due to its flexibility, was tested to study its effects on the room air quality as well as ventilation performance. For the study, physical tests using a small model room and numerical modeling using CFD computation were utilized to evaluate different test conditions employing mixing ventilation from the ceiling. The partition parameters, such as its location, height, and the gap underneath, as well as contaminant source location were tested under isothermal conditions. This paper summarizes the results from the study.