878 resultados para Abrasive Wear and Tear
Resumo:
This in situ/ex vivo study assessed the effect of different concentrations of fluoride in dentifrices on dentin subjected to erosion or to erosion plus abrasion. Ten volunteers took part in this crossover and double-blind study performed in 3 phases (7 days). They wore acrylic palatal appliances containing 4 bovine dentin blocks divided in two rows: erosion and erosion plus abrasion. The blocks were subjected to erosion by immersion ex vivo in a cola drink (60 s, pH 2.6) 4 times daily. During this step, the volunteers brushed their teeth with one of three dentifrices D (5,000 ppm F, NaF, silica); C (1,100 ppm F, NaF, silica) and placebo (22 ppm F, silica). Then, the respective dentifrice slurry (1: 3) was dripped on dentin surfaces. While no further treatment was performed in one row, the other row was brushed using an electric toothbrush for 30 s ex vivo. The appliances were replaced in the mouth and the volunteers rinsed with water. Dentin loss was determined by profilometry and analyzed by 2-way ANOVA/Bonferroni test (alpha = 0.05). Dentin loss after erosive-abrasive wear was significantly greater than after erosion alone. Wear was significantly higher for the placebo than for the D and C dentifrices, which were not significantly different from each other. It can be concluded that the presence of fluoride concentrations around 1,100 ppm in dentifrices is important to reduce dentin wear by erosion and erosion + abrasion, but the protective effect does not increase with fluoride concentration. Copyright (C) 2008 S. Karger AG, Basel.
Resumo:
Objectives: This in situ study evaluated the effect of an erosive challenge on different restorative materials and on enamel restored with these materials, as well as the ability of these materials to protect the adjacent enamel against erosion. Methods: Ten volunteers wore palatal devices with eight bovine enamel blocks, randomly selected and distributed into two vertical rows, corresponding to the following groups: GI/GV, resin-modified glass ionomer; GII/GVI, conventional glass ionomer; GIII/GVII, composite resin; GIV/GVIII, amalgam. one row (corresponding to groups I-IV) was immersed in a cola drink and the other row (corresponding to groups V-VIII) was subjected to saliva only. The palatal device was continuously worn for 7 days and only half of the appliance (groups I-IV) was immersed in the soft drink (Coca-Cola (R), 150 mL) for 5 min, three times a day. The study variables comprised the wear (profilometry, mu m) and the percentage of surface microhardness change (%SMHC). Data were tested for significant differences by two-way ANOVA and Tukey`s tests (p < 0.05). Results: Considering the restorative materials, for %SMHC and wear, there were no differences among the materials and between the saliva and the erosive challenge. For enamel analyses, the erosive challenge promoted a higher wear and %SMHC of the enamel than did the saliva. There were no significant differences in wear and %SMHC of the enamel adjacent to the different restorative materials. Conclusion: This research data suggest that there is little %SMHC and wear of the studied restorative materials and none of them had a preventive effect against erosion on adjacent enamel, which showed a pronounced wear. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
In the injection moulding of polypropylene reinforced with hard glass fibres, die materials are commonly subjected to severe abrasive wear. In order to improve its wear resistance, an unbalanced magnetron sputtering PVD compositional monolayered coating has been produced. The film was composed by a nanostructured TiB2 monolayer. Microstructure characterization and thickness evaluation were conducted by scanning electron microscopy (SEM). Film topography and roughness were accessed by SEM and Atomic Force Microscopy (AFM). The phase analyse was investigated by X-ray diffraction (XRD), using Cu Kalpha radiation. Scratch tests were conducted in order to study the film adhesion to the substrate. Load-Displacement curves (nanoindentation analysis) allowed measuring the film hardness and Young's modulus. A ball-cratering tribometer was used to determine the micro-abrasion laboratorial wear resistance, under different tests conditions, using SiC particles in distilled water slurry. At the end of these tests, the worn surfaces were analyzed by SEM and Energy Dispersive X-ray Spectroscopy (EDS) in order to compare these results with some other coatings already tested in the same conditions. To test the practical wear resistance, 135000 injection cycles were done in a plastic injection industrial mould. Coated samples were put on the plastic feed canal, after a turbulent zone. In these tests, a 30% (wt) glass fibres reinforced polypropylene was used. Worn sample surfaces were analyzed by SEM after 45.000 and 90.000 cycles. Image analyses were made in order to evaluate the damage increases and to observe the wear mechanisms involved.
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Dissertação de mestrado em Optometria Avançada
Resumo:
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.
Resumo:
The Museo de La Serena, IV Region, Chile has collections of skeletal remains representing the agricultural Diaguita people of 500 years ago excavated in the 1980s from the sites Peñuelas 21 and 24, Chile's semiarid north. Their excellent preservation has permitted an osteobiographical and radiographic analysis to better understand the patterns of the disease. This research continues the osteological analyses begun in 1989 by Rosado that seek to understand the impact the transition to and adoption of farming had on the health of prehistoric populations. Because of the significance of paleopathology in the understanding of cultural and biological adaptations, it has also become necessary to assess the preservation status and design a conservation protocol to protect and document the remains. The objectives of this communication are to: establish demographic patterns of the skeletal samples and identify and diagnose skeletal paleopathologies via photography and radiographs. Intentional cranial alteration, limb and cranial fractures, dental wear, and dental abscesses and caries are among the interesting paleopathologies so far documented. Intentional cranial alteration is very common and is manifested as tabular erect in both males and females. The high frequency of carious lesions indicates a diet that emphasized carbohydrates. Skeletal radiographs are available for several of the individuals in the sample and this has afforded a more detailed description of the paleopathologies originally documented via photography.
Resumo:
Tripping is considered a major cause of fall in older people. Therefore, foot clearance (i.e., height of the foot above ground during swing phase) could be a key factor to better understand the complex relationship between gait and falls. This paper presents a new method to estimate clearance using a foot-worn and wireless inertial sensor system. The method relies on the computation of foot orientation and trajectory from sensors signal data fusion, combined with the temporal detection of toe-off and heel-strike events. Based on a kinematic model that automatically estimates sensor position relative to the foot, heel and toe trajectories are estimated. 2-D and 3-D models are presented with different solving approaches, and validated against an optical motion capture system on 12 healthy adults performing short walking trials at self-selected, slow, and fast speed. Parameters corresponding to local minimum and maximum of heel and toe clearance were extracted and showed accuracy ± precision of 4.1 ± 2.3 cm for maximal heel clearance and 1.3 ± 0.9 cm for minimal toe clearance compared to the reference. The system is lightweight, wireless, easy to wear and to use, and provide a new and useful tool for routine clinical assessment of gait outside a dedicated laboratory.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to develop instruments to quantitatively assess the soft-tissue balance since excessive imbalance can accelerate prosthesis wear and lead to early surgical revision. The instrumented distractor proposed in this study can assist surgeons on performing ligament balance by measuring the distraction gap and applied load. Also the device allows the determination of the ligament stiffness which can contribute a better understanding of the intrinsic mechanical behavior of the knee joint. Instrumentation of the device involved the use of hall-sensors for measuring the distractor displacement and strain gauges to transduce the force. The sensors were calibrated and tested to demonstrate their suitability for surgical use. Results show the distraction gap can be measured reliably with 0.1mm accuracy and the distractive loads could be assessed with an accuracy in the range of 4N. These characteristics are consistent with those have been proposed, in this work, for a device that could assist on performing ligament balance while permitting surgeons evaluation based on his experience. Preliminary results from in vitro tests were in accordance with expected stiffness values for medial collateral ligament (MCL) and lateral collateral ligament (LCL).
Resumo:
There are many miles of portland cement concrete pavement in Iowa that due to normal wear, and in some cases accelerated wear from studded tires, the surface has become polished resulting in less than desirable friction values. Retexturing the surface may be an economical way to re-establish desirable friction values. Retexturing by grinding with diamond blades and transverse grooving with diamond blades are two methods of rehabilitating p.c.c. surfaces. MU Inc. of Lebanan, Tennessee proposed to provide without charge to the Iowa Department of Transportation, one 1500 ft x 12 ft section each of three methods of texturing. They are longitudinal grinding, transverse grooving and longitudinal grinding followed by transverse grooving. A section of 1500 feet is needed to properly evaluate a texturing method. It was decided by Iowa DOT personnel that due to possible differential friction it would be undesirable to texture only one lane. The decision was made to do test sections of 1500 ft x 24 ft with the cost of the additional texturing paid by the Iowa DOT. Iowa also has areas where the p.c.c. pavement has faulted at the joints and cracks which results in poor riding quality. Methods of correcting the faulting are to underseal the pavement where needed and/or grinding the surface to eliminate the faulted areas. It was decided to include in this research project a section for profiling by grinding.
Resumo:
Cities and counties in Iowa have more than 8,890 steel bridges, most of which are painted with red lead paint. The Iowa Department of Transportation (Iowa DOT) maintains less than 35 bridges coated with red lead paint, including seven of the large border bridges over the Mississippi and Missouri Rivers. Because of the federal and state regulations for bridge painting, many governmental agencies have opted not to repaint, or otherwise maintain, lead paint coatings. Consequently, the paint condition on many of these bridges is poor, and some bridges are experiencing severe rusting of structural members. This research project was developed with two objectives: 1) to evaluate the effectiveness of preparing the structural steel surface of a bridge with high pressure water jetting instead of abrasive blasting and 2) to coat the structural steel surface with a moisture-cured polyurethane paint under different surface preparation conditions.
Resumo:
Alumiini on pienen ominaispainonsa, hyvän korroosiokestävyytensä ja muotoiltavuutensa ansiosta runsaasti käytetty materiaali niin koneenosissa, kuin monissa muissakin rakenteissa. Alumiinin pehmeys ja huono kulumiskestävyys ovat rajoittaneet sen käyttöä. Alumiinin kovuuden ja kulumiskestävyyden parantaminen laajentaisi sen käyttömahdollisuuksia. Laserpintakäsittelymenetelmien käyttö on potentiaalinen, mutta vielä vähän tutkittu keino alumiinin kulumiskestävyyden parantamiseksi. Diplomityön teoriaosassa käsitellään materiaalin eri kulumismekanismeja, kohdemateriaali alumiinin ominaisuuksia ja tarkastellaan keinoja parantaa kulumiskestävyyttä sekä perinteisillä tekniikoilla että erityisesti lasertekniikoiden avulla. Diplomityön kokeellisessa osassa tehtiin laserpintakäsittelykokeita Nd:YAG-laserilla tavoitteena kovuuden ja kulumiskestävyyden parantaminen. Parhaat tulokset saavutettiin laserpinnanseostustekniikalla nikkelipohjaisella Inconel 625-seosaineella. Diplomityössä tehdyissä kokeissa saavutettiin yli 10-kertainen alumiinin pinnankovuus verrattuna käsittelemättömään perusaineeseen. Abrasiivinen kulumiskestävyys parantui parhaimmillaan yli kolminkertaiseksi verrattuna käsittelemättömään alumiiniin ja anodisoituihin vertailukappaleisiin. Tutkimuksessa määriteltiin myös parametrialue kokeissa käytetyille perus- ja lisäaineelle. Diplomityössä tehdyt kokeet toimivat hyvänä pohjana jatkokokeille.
Resumo:
The purpose of this work was to study the effect of aspen and alder on birch cooking and the quality of the pulp produced. Three different birch kraft pulps were studied. As a reference, pure aspen and alder were included. The laboratory trials were done at the UPM Research Centre in Lappeenranta, Finland. The materials used were birch, aspen and alder mill chips that were collected around the area of South-Carelia in Finland. The chips used in the study were pulped using a standard kraft process. The pulps including birch fibres were ECF-bleached at laboratory scale to a target brightness of 85 %. The bleached pulps were beaten at low consistency by a laboratory Voith Sulzer refiner and tested for optical and physical properties. The theoretical part is a study of hardwoods that takes into accounts the differences between birch, aspen and alder. Major sub-areas were fibre and paper-technical properties as well as chemical composition and their influence on the different properties. The pulp properties of birch, aspen and alder found in previous studies were reported. Russian hardwood forest resources were also investigated. The fundamentals of kraft pulping and bleaching were studied at the end of theoretical part. The major effect of replacing birch with aspen and alder was the deterioration (lowering) of tensile and tear strengths. In other words, addition of aspen and alder to a birch furnish reduced strength properties. The reinforcement ability of the tested pulps was the following: 100 % birch > 80 % birch, 20 % aspen > 70 % birch, 20 % aspen, 10 % alder. The second thing noted was that blending of birch together with aspen and alder give better smoothness, optical properties and also formation. It can be concluded, that replacement of birch with alder during cooking by more than 10 % can negatively affect on the paper-technical properties of birch pulp. Mixing pure birch and aspen pulps would be more beneficial when producing printing paper made from chemical pulp.
Resumo:
The study aimed to evaluate tear production by means of modified Schirmer tear tes-1 (mSTT-1) in neonate cats. Likewise, correlation between mSTT-1 and STT-1 was assessed in vitro. Standard SST strips were cut in half and after eye lid opening, tear production of neonates (n=15) was daily measured in both eyes (mSTT-1), until the 7th day, and at day 14, 21, and 28. Animals were daily weighted until 28 days of age. Results were compared statistically (P<0.05). During the first 7 days, the overall mSTT-1 mean was 0.76 wetting/minute. Significant differences between right and left eyes were not observed at any time point (P=1.00). Tear secretion increased significantly, from the 14th to 28th day, in comparison with 7 first days (P<0.05). Positive correlation between maturity parameters and tear secretion was observed (P<0.0001). Distance between slopes of each strip changed significantly (P<0.0001). It was concluded that tear secretion in the neonatal period of cats is very below the reference values described for young and adults of the same species. It is not possible to extrapolate results obtained with mSTT-1 to standard STT-1.