957 resultados para AXIAL DIVERGENCE
Resumo:
The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 µm (IPT-42) and the analytical curve was applied for quantification of two others reference materials (IPT-28 and IPT-32) and four samples. It was demonstrated that the analytical curve thus obtained was not completely suitable for IPT-28 and samples due to different mineralogical phases determined by X-ray diffraction. After considering this effect, it was possible for most elements to obtain results in agreement with certified values or with values obtained by a conventional technique at a 95% confidence level. It was demonstrated that the ICP-OES with axial view configuration did not present any incompatibility with the direct introduction of a complex inorganic suspension.
Resumo:
Atropisomerism is a special kind of stereoisomeric relationship that arises from the freezing of a certain conformation of an organic molecule, associated with a high rotational barrier about a single covalent bond. Atropisomerism has been originally described in orto-functionalyzed biphenyl derivatives, but a lot of other organic functionalities can present this structural phenomenon, characterized by the presence of chiral properties in compounds that don't present classical stereogenic centers. Atropisomeric compounds, intermediates and catalysts have well-know importance in organic synthesis, but the influence of the axial chirality in substances able to modulate biological systems is still not very exploited in drug design and development. In this context, the present account describes the importance of this structural property in the medicinal chemistry of different classes of bioactive compounds or therapeutic agents, emphasizing how atropisomerism could affect the molecular recognition of a ligand or a prototype by the target bioreceptor.
Resumo:
Concentrated winding permanent magnet machines and their electromagnetic properties are studied in this doctoral thesis. The thesis includes a number of main tasks related to the application of permanent magnets in concentrated winding open slot machines. Suitable analytical methods are required for the first design calculations of a new machine. Concentrated winding machines differ from conventional integral slot winding machines in such a way that adapted analytical calculation methods are needed. A simple analytical model for calculating the concentrated winding axial flux machines is provided. The next three main design tasks are discussed in more detail in the thesis. The magnetic length of the rotor surface magnet machines is studied, and it is shown that the traditional methods have to be modified also in this respect. An important topic in this study has been to evaluate and minimize the rotor permanent magnet Joule losses by using segmented magnets in the calculations and experiments. Determination of the magnetizing and leakage inductances for a concentrated winding machine and the torque production capability of concentrated winding machines with different pole pair numbers are studied, and the results are compared with the corresponding properties of integral slot winding machines. The thesis introduces a new practical permanent magnet motor type for industrial use. The special features of the machine are based on the option of using concentrated winding open slot constructions of permanent magnet synchronous machines in the normal speed ranges of industrial motors, for instance up to 3000 min-1, without excessive rotor losses. By applying the analytical equations and methods introduced in the thesis, a 37 kW 2400 min-1 12-slot 10-pole axial flux machine with rotor-surfacemounted magnets is designed. The performance of the designed motor is determined by experimental measurements and finite element calculations.
Resumo:
The performance of inductively-coupled plasma optical emission spectrometers with axial and radial views for determination of iodine in table salt was evaluated. Interference and memory effects in nitric acid and water-soluble tertiary amines (CFA-C) media were studied. Based on a factorial experiment, one optimum instrument operational condition for axial configuration, and two optima conditions for radial configuration was established. The ICP OES with axial view was 5-fold more sensitive than the radial view. Both matrix matching and standard addition methods were used for iodine quantification and for most samples, both strategies of calibration led to similar results. Recoveries ranged from 104 to 114%.
Resumo:
Genetic divergence within and among races of Colletotrichum lindemuthianum was determined using RAPD markers. In addition to the different races of the fungus three isolates of the sexual stage of Colletotrichum lindemuthianum (Glomerella cingulata f.sp. phaseoli) were included in this study. The band patterns generated using 11 primers produced 133 polymorphic bands. The polymorphic bands were used to determine genetic divergence among and within the pathogen races. The isolates analyzed were divided into six groups with 0.75 relative similarity. Group VI, formed by three isolates of the sexual phase of Colletotrichum lindemuthianum, was the most divergent. Races previously determined using differential cultivars did not correlate with the results obtained using RAPD markers.
Resumo:
Supersonic axial turbine stages typically exhibit lower efficiencies than subsonic axial turbine stages. One reason for the lower efficiency is the occurrence of shock waves. With higher pressure ratios the flow inside the turbine becomes relatively easily supersonic if there is only one turbine stage. Supersonic axial turbines can be designed in smaller physical size compared to subsonic axial turbines of same power. This makes them good candidates for turbochargers in large diesel engines, where space can be a limiting factor. Also the production costs are lower for a supersonic axial turbine stage than for two subsonic stages. Since supersonic axial turbines are typically low reaction turbines, they also create lower axial forces to be compensated with bearings compared to high reaction turbines. The effect of changing the stator-rotor axial gap in a small high (rotational) speed supersonic axial flow turbine is studied in design and off-design conditions. Also the effect of using pulsatile mass flow at the supersonic stator inlet is studied. Five axial gaps (axial space between stator and rotor) are modeled using threedimensional computational fluid dynamics at the design and three axial gaps at the off-design conditions. Numerical reliability is studied in three independent studies. An additional measurement is made with the design turbine geometry at intermediate off-design conditions and is used to increase the reliability of the modelling. All numerical modelling is made with the Navier-Stokes solver Finflo employing Chien’s k ¡ ² turbulence model. The modelling of the turbine at the design and off-design conditions shows that the total-to-static efficiency of the turbine decreases when the axial gap is increased in both design and off-design conditions. The efficiency drops almost linearily at the off-design conditions, whereas the efficiency drop accelerates with increasing axial gap at the design conditions. The modelling of the turbine stator with pulsatile inlet flow reveals that the mass flow pulsation amplitude is decreased at the stator throat. The stator efficiency and pressure ratio have sinusoidal shapes as a function of time. A hysteresis-like behaviour is detected for stator efficiency and pressure ratio as a function of inlet mass flow, over one pulse period. This behaviour arises from the pulsatile inlet flow. It is important to have the smallest possible axial gap in the studied turbine type in order to maximize the efficiency. The results for the whole turbine can also be applied to some extent in similar turbines operating for example in space rocket engines. The use of a supersonic stator in a pulsatile inlet flow is shown to be possible.
Resumo:
The study of convergence and divergence in global economy and social development utilises comparative indicators to investigate the contents of economic and social development policy and their effects on the global samples that represent the rich industrial, semi-industrial and the poor developing nations. The study searchesfor answers to questions such as "what are the objectives of economic growth policies in globalisation under the imperatives of convergence and divergence, and how do these affect human well-being in consideration to the objectives of social policy in various nations?" The empirical verification of data utilises the concepts of the `logic of industrialism´ for comparative analysis that focuses mainly on identifying the levels of well-being in world nations after the Second World War. The perspectives of convergence and divergence in global economy and social development critically examine the stages of early development processes in global economy, distinguish the differences between economy and social development, illustrate the contents of economic and social development policies, their effects on rich and poor countries, and the nature of convergence and divergence in propelling economic growth and unequal social development in world nations. The measurement of convergence and divergence in global economy and social development utilised both economic and social data that were combined into an index that measures the precise levels of the effects of economic and social development policies on human well-being in the rich and poor nations. The task of finding policy solutions to resolve the controversies are reviewed through empirical investigations and the analyses of trends indicated within economic and social indicators and data. These revealed how the adoption of social policy measures in translating the gains from economic growth, towards promoting education, public health, and equity, generate social progress and longer life expectancy, higher economic growth, and sustain more stable macro economy for the nations. Social policy is concerned with the translation of benefits from objectives of global economic growth policies, to objectives of social development policy in nation states. Social policy, therefore, represents an open door whereby benefits of economic growth policies are linked with the broader objectives of social development policy, thereby enhancing the possibility of extending benefits from economic growth to all human being in every nation.
Resumo:
A colheita mecanizada é ferramenta fundamental no processo produtivo das grandes culturas; se não for realizada adequadamente, poderá resultar em danos mecânicos severos às sementes, acarretando, prejuízos significativos na colheita, particularmente devido à redução da qualidade. Visando a avaliar os danos causados na colheita mecanizada de soja, o presente trabalho teve como objetivo estudar o efeito do sistema de trilha axial sobre a percentagem de bandinhas, impurezas e sementes quebradas de soja cv. M-Soy 8001, em função da velocidade de trabalho e rotação do cilindro trilhador. O delineamento experimental utilizado foi o inteiramente casualizado, em parcelas subdivididas, avaliando-se duas rotações do cilindro trilhador (400 e 500 rpm) e três velocidades de operação (3,5; 4,5 e 5,5 km h-1), com três repetições. Os resultados obtidos indicam que as combinações de velocidade de operação e rotações do cilindro de trilha avaliadas não afetam as variáveis vigor, impurezas, bandinha, emergência em areia e índice de velocidade de germinação e que o aumento da rotação de 400 para 500 rpm ocasiona o aumento de sementes quebradas.
Resumo:
O trabalho objetivou avaliar dois tipos de colhedoras, de fluxo radial e axial, em relação à qualidade física e fisiológica de sementes de duas cultivares de soja, BRS 184 e BRS 133, colhidas em dois horários, às 10 e 18 horas. A colhedora de fluxo radial trabalhou a 5,0 km h-1 , com o cilindro batedor a 750 rotações por minuto (rpm). A colhedora de fluxo axial trabalhou a 8,0 km h-1, e rotor com 650 rpm. Para a avaliação da qualidade física e fisiológica das sementes, foram realizados testes de germinação, envelhecimento acelerado, tetrazólio, dano mecânico (hipoclorito), umidade de campo e laboratório, sementes quebradas (bandinha) e pureza. A colheita realizada às 18 horas, com grau de umidade menor que 12%, ocasionou maiores danos mecânicos nas sementes da cultivar BRS 184. A colhedora de sistema de fluxo axial resultou em sementes de melhor qualidade fisiológica para a cultivar BRS 184, e em menores percentuais de sementes quebradas e maior pureza para ambas as cultivares, comparativamente à colhedora de sistema de trilha com fluxo radial.
Resumo:
The study aimed to determine an optimum angle for the nozzles axial-flow sprayers a deposition for better vertical distribution focused on cashew. In laboratory tests were conducted adjusting the angle of the nozzle axial-flow sprayers. The experimental design was randomized blocks in a 2x3 factorial with four replications. The treatment for this test were two settings (with and without the adjustment of the angles of the nozzles ) and tree application volumes 273, 699 and 954 L ha-¹.The study was conducted in an orchard of dwarf cashew, with eight years of age. It was concluded that the volumetric distribution profile showed better vertical distribution uniformity when the angles of the nozzles were regulated for the canopy, the adjustment of the angles of the nozzles for the canopy provided greater deposition of droplets, the increased volume of application resulted in higher depositions in the leaves of the crop.
Resumo:
OBJETIVO: Analisar a resistência (rigidez) do sistema de fixação externa tubular uniplanar, com hastes de conexão única e dupla, com traços de fraturas estáveis e instáveis. MÉTODOS: Foram utilizados 48 modelos semelhantes à tíbia. Em todos foi deixado um intervalo de 0,5 cm entre os fragmentos e realizados cortes com angulações de 15º e 45º para simular fraturas estáveis e instáveis, respectivamente. Os modelos foram divididos em quatro grupos de acordo com o traço fraturário (15º e 45º) e o número de barras metálicas na montagem (1 e 2 barras). Os modelos de prova foram adaptados à uma máquina de testes Instron®, pelas suas extremidades, e submetidos à compressão axial até que os fragmentos tiveram contato total. Avaliou-se a força necessária para efetuar o completo contato dos fragmentos do modelo. RESULTADOS: As forças instabilizadoras na montagem do fixador com barra dupla foram bastante superiores às com barra única. Observou-se ainda que o grupo com barra única instável apresentou variabilidade muito menor que os demais grupos, ou seja, apresenta resultados mais homogêneos, além de ter apresentado a menor média. CONCLUSÃO: A montagem do fixador externo com uma haste longitudinal dupla nos modelos estudados é mais estável que as demais quando submetidas à uma força de compressão axial.
Resumo:
Measurement is a tool for researching. Therefore, it is important that the measuring process is carried out correctly, without distorting the signal or the measured event. Researches of thermoelectric phenomena have been focused more on transverse thermoelectric phenomena during recent decades. Transverse Seebeck effect enables to produce thinner and faster heat flux sensor than before. Studies about transverse Seebeck effect have so far focused on materials, so in this Master’s Thesis instrumentation of transverse Seebeck effect based heat flux sensor is studied, This Master’s Thesis examines an equivalent circuit of transverse Seebeck effect heat flux sensors, their connectivity to electronics and choosing and design a right type amplifier. The research is carried out with a case study which is Gradient Heat Flux Sensors and an electrical motor. In this work, a general equivalent circuit was presented for the transverse Seebeck effect-based heat flux sensor. An amplifier was designed for the sensor of the case study, and the solution was produced for the measurement of the local heat flux of the electric motor to improve the electromagnetic compatibility.
Resumo:
The aim of this study was to describe the axial skeleton of a wild Brazilian carnivorous, the crab-eating fox (Cerdocyon thous). Five specimens of crab-eating fox were previously unfrozen for radiographic exams and their bones went through dissection and chemical maceration. This animal presents seven cervical vertebrae, and from the third on, they become shorter and wider than the other ones e the spinous process was makeable from the fifth cervical vertebrae on. There are thirteen thoracic vertebrae and the spinous process of the lumbar vertebrae, which are seven, decreases from the fifth on. The sacrum is formed by two vertebrae and there are twenty or twenty one caudal vertebrae. It can be concluded that the crab-eating fox axial skeleton is similar to that of the domestic dog.
Resumo:
Resumo: Feridas de grandes extensões, com perda da viabilidade tecidual e retardo na cicatrização por segunda intenção são casos que se faz necessário o emprego de técnicas cirúrgicas reconstrutivas. O plasma rico em plaquetas (PRP) é um produto com maior concentração plaquetária, adjuvante no processo cicatricial de cirurgias reconstrutivas, auxiliando nos processos de hemostasia e estimulação da angiogênese. Dessa forma, delineou-se um estudo a fim de avaliar a eficácia do uso do gel produzido a partir do plasma rico em plaquetas (PRP) em flapes de avanço de padrão axial toracodorsal em coelhos, para avaliar a possibilidade de favorecer a integração do retalho no leito receptor. Utilizaram-se 30 coelhos da raça Nova Zelândia branco, separados em dois grupos de 15 animais, compreendendo os grupos plasma rico em plaquetas (GPRP), na qual empregou-se o gel antes da síntese da ferida cirúrgica, e controle (GC), na qual utilizou-se apenas solução fisiológica. Para obtenção do PRP, coletou-se sangue dos animais, e determinou-se a contagem plaquetária antes da preparação do gel. No início e término do experimento os animais foram pesados para posterior análise de ganho peso médio. Após o procedimento cirúrgico iniciou-se as avaliações macroscópicas no 3º, 7º e 14º dia, e avaliou-se presença ou ausência de exsudato, integridade da pele, edema, rubor e necrose. Após esta etapa, coletou-se o material da ferida cirúrgica para confecção das lâminas histológicas e posterior avaliação microscópica. Avaliou-se a proliferação vascular, presença de células mononucleares e polimorfonucleares, proliferação fibroblástica, colagenização, reepitelização e hemorragia. Os dados obtidos foram submetidos à análise estatística (Teste t Student, t emparalhado, e Kruskall Walis, sendo p<0,05). O ganho de peso médio não foi significativo entre os grupos; a concentração plaquetária da amostra final do PRP foi significativamente maior quando comparada com a inicial; exsudato e necrose foram significativamente maior no grupo controle quando comparado ao grupo PRP; proliferação vascular e reepitelização foram significativamente maior no grupo PRP, enquanto que a presença de mononucleares, polimorfonucleares, proliferação de fibroblastos, colagenização e hemorragia não foram significativas entre os grupos. Obteve-se no terceiro dia, diferença significativamente maior quanto à variável exsudato no grupo controle quando comparado ao grupo PRP, no sétimo dia exsudato e rubor foram significativamente maior no grupo controle, e ao décimo quarto dia exsudato e integridade da pele foram significativamente maior no grupo controle. Os resultados obtidos neste estudo evidenciaram que a utilização do plasma rico em plaquetas na forma de gel em cirurgia reconstrutiva foi capaz de estimular a angiogênese na ferida favorecendo o processo de cicatrização.