292 resultados para ANESTHESIOLOGY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A associação entre ropivacaína e clonidina agiria menos que a ropivacaína isolada na mãe e no feto? Foram pesquisados os efeitos materno-fetais de duas técnicas farmacológicas: pequena dose de ropivacaína ou dose menor de ropivacaína mais clonidina na analgesia peridural para parto. TIPO DE ESTUDO E LOCAL: Estudo prospectivo, Departamento de Anestesiologia, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista. MÉTODOS: Trinta e duas parturientes, estado físico de acordo com a American Society of Anesthesiologists I e II, foram aleatoriamente submetidas à analgesia peridural com 15 ml de ropivacaína 0,125% (grupo R) ou 15 ml de ropivacaína 0,0625% mais clonidina, 75 µg (grupo RC). Foram avaliados: intensidade da dor, nível do bloqueio sensitivo, latência, intensidade do bloqueio motor, duração da analgesia de parto e da analgesia peridural. Os neonatos foram avaliados pelo Apgar e método de Amiel-Tison (capacidade neurológica e adaptativa). RESULTADOS: Não houve diferenças significativas entre grupos para dor, nível de bloqueio sensitivo, duração da analgesia peridural e Apgar. Para latência, duração da analgesia de parto e bloqueio motor, grupo R < grupo RC. O escore da capacidade neurológica e adaptativa de meia e duas horas foi maior para o grupo R. Cem por cento dos neonatos do grupo R e 75% dos do grupo RC estavam neurologicamente saudáveis ao exame de 24 horas. CONCLUSÃO: Pequena dose de ropivacaína e dose menor mais clonidina aliviaram a dor materna durante o parto. Neonatos de mães que receberam apenas ropivacaína mostraram melhores escores da capacidade neurológica e adaptativa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A dor pós-operatória continua sendo uma das principais complicações pós-operatórias e motivo de desconforto, principalmente em crianças. O objetivo deste estudo foi avaliar o uso de analgésicos desde o término da cirurgia até a alta da sala de recuperação pós-anestésica (SRPA), como medida terapêutica ou profilática, para crianças com menos de 1 ano de idade. MÉTODO: Utilizando o banco de dados do Departamento de Anestesiologia, foi realizada análise retrospectiva, envolvendo o período de janeiro de 2000 a abril de 2001, das anestesias de crianças menores que 1 ano de idade submetidas a procedimentos cirúrgicos diversos, avaliando aspectos relacionados à analgesia pós-operatória. RESULTADOS: No período do estudo, foram anestesiadas 402 crianças menores que 1 ano, sendo que 194 (48,2%) não receberam analgésicos e 208 (51,8%) receberam. Com relação ao uso ou não de analgésicos, foi observado o que se segue: Sem analgésicos: (1) Idade: até 1 mês, 68/99; entre 1 e 6 meses, 53/126; entre 6 meses e 1 ano, 73/177. (2) Peso: 6,7 ± 3,1 kg (3). Sexo: masculino, 106/240; feminino, 88/162. (4) Estado físico ASA: ASA I, 69/187; ASA II, 56/113; ASA III, 46/79; ASA IV, 23/23. (5) Anestesia peridural sacral: 3/4. (6) Tempo de anestesia: 106 ± 32 minutos. (7) Encaminhamento para unidade de terapia intensiva (UTI): 93/119. Uso de analgésicos: (1) Idade: até 1 mês, 31/99; entre 1 e 6 meses, 73/126; entre 6 meses e 1 ano, 104/177. (2) Peso: 9 ± 2,3 kg. (3) Sexo: masculino, 134/240; feminino, 74/162. (4) Estado físico ASA: ASA I, 118/187; ASA II, 57/113; ASA III, 33/79; ASA IV, 0/23. (5) Anestesia peridural sacral: 1/4. (6) Tempo de anestesia: 130 ± 38 minutos. (7) Encaminhamento para UTI: 26/119. Os fármacos empregados para promover analgesia foram: dipirona (60,6%), dipirona + tramadol (25,5%), dipirona + nalbufina (5,3%), tramadol (3,8%), nalbufina (3,8%), meperidina (0,5%) e fentanil (0,5%). CONCLUSÕES: Utilizar analgésicos em crianças desde o término da cirurgia até a alta da SRPA não foi habitual, principalmente nas crianças menores e mais graves e em procedimentos cirúrgicos mais rápidos. O uso de dipirona, isoladamente, ou a associação dipirona/tramadol, foram as drogas analgésicas mais freqüentemente empregadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A dexmedetomidina é um novo agonista alfa2-adrenérgico que apresenta relação de seletividade entre os receptores alfa2:alfa1 de 1600:1, com importante ação sedativa e analgésica, bom controle hemodinâmico frente ao estresse e que pode produzir, por si só, anestesia. Este agente tem sido empregado para promover analgesia e sedação no período pós-operatório e nas unidades de tratamento intensivo. Devido à suas propriedades, recentemente, a dexmedetomidina passou a ser utilizada também na sala de operações, como fármaco coadjuvante em anestesia. Assim, este artigo faz uma revisão da literatura com relação ao uso da dexmedetomidina na prática anestésica. CONTEÚDO: São apresentados os principais trabalhos com o emprego da dexmedetomidina em Anestesiologia, seja como medicação pré-anestésica, ou durante o ato anestésico-cirúrgico. O mecanismo de ação dos fármacos alfa2-agonistas e as propriedades farmacocinéticas e farmacodinâmicas da dexmedetomidina também são revistos neste artigo. CONCLUSÕES: O uso da dexmedetomidina como medicação pré-anestésica, durante anestesia, ou no período pós-operatório, promove boa estabilidade hemodinâmica. Há redução do consumo de anestésicos durante a anestesia. Os pacientes sedados com a dexmedetomidina podem ser despertados, quando solicitados, e tornarem-se cooperativos. Mesmo doses elevadas do fármaco não provocam depressão respiratória. Bradicardia é um efeito adverso observado com freqüência, problema amenizado pela administração lenta da droga. Assim, a dexmedetomidina torna-se importante recurso adicional para a prática clínica da Anestesiologia, com possibilidade de uso em diversos tipos de pacientes e procedimentos cirúrgicos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Eventos considerados menores têm assumido papel fundamental na determinação da qualidade do serviço prestado na área da Anestesiologia. O objetivo do presente estudo foi avaliar as principais preocupações dos pacientes em relação ao período pós-anestésico e testar a hipótese de que os efeitos mais indesejados podem ser influenciados por características demográficas. MÉTODO: Um questionário foi respondido por 440 pacientes imediatamente antes da avaliação pré-anestésica. Foram listados os possíveis efeitos indesejáveis no período pós-operatório imediato, baseados em levantamento a partir de dados disponíveis na literatura e considerando o critério de frequência, mas não o de gravidade. Foram avaliados os dados demográficos e pesquisadas as nove preocupações mais frequentemente citadas. As informações coletadas a partir da análise dos questionários preenchidos pelos entrevistados foram relacionadas com seus dados antropométricos, socioeconômicos e educacionais, com o objetivo de avaliar a influência dessas variáveis no perfil das respostas. RESULTADOS: Entre os efeitos indesejados, o temor de acordar intubado foi o mais frequentemente citado como o mais importante, seguido de dor forte no local da cirurgia e acordar durante a cirurgia. A análise dos três efeitos mais indesejados em relação aos dados demográficos não evidenciou diferença estatística significativa, com exceção do item dor no local da cirurgia (menos citada entre pacientes do sexo masculino). CONCLUSÕES: As principais preocupações dos pacientes em relação ao período pós-anestésico são: acordar com um tubo na garganta, dor forte no local da cirurgia e a lembrança de estar acordado durante a cirurgia. A idade, o grau de escolaridade e a renda familiar não determinaram diferenças nas preocupações dos pacientes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Lung deposition of intravenous cephalosporins is low. The lung deposition of equivalent doses of ceftazidime administered either intravenously or by ultrasonic nebulization using either nitrogen-oxygen or helium-oxygen as the carrying gas of the aerosol was compared in ventilated piglets with and without experimental bronchopneumonia. Methods: Five piglets with noninfected lungs and 5 piglets with Pseudomonas aeruginosa experimental bronchopneumonia received 33 mg/kg ceftazidime intravenously. Ten piglets with noninfected lungs and 10 others with experimental P. aeruginosa bronchopneumonia received 50 mg/kg ceftazidime by ultrasonic nebulization. In each group, the ventilator was operated in half of the animals with a 65%/35% helium-oxygen or nitrogen-oxygen mixture. Animals were killed, and multiple lung specimens were sampled for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography. Results: As compared with intravenous administration, nebulization of ceftazidime significantly increased lung tissue concentrations (17 ± 13 vs. 383 ± 84 μg/g in noninfected piglets and 10 ± 3 vs. 129 ± 108 μg/g in piglets with experimental bronchopneumonia; P < 0.001). The use of a 65%/35% helium-oxygen mixture induced a 33% additional increase in lung tissue concentrations in noninfected piglets (576 ± 141 μg/g; P < 0.001) and no significant change in infected piglets (111 ± 104 μg/g). Conclusion: Nebulization of ceftazidime induced a 5- to 30-fold increase in lung tissue concentrations as compared with intravenous administration. Using a helium-oxygen mixture as the carrying gas of the aerosol induced a substantial additional increase in lung deposition in noninfected piglets but not in piglets with experimental bronchopneumonia. © 2005 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The laryngeal mask has been frequently used in Anesthesiology. Although the rate of complications with this technique is smaller than that of the endotracheal tube, it is not devoid of risks, especially in cases of difficult airways. The objective of this study was to report a case of unilateral lingual nerve damage after the use of the laryngeal mask airway. CASE REPORT: A female patient underwent a surgical procedure for removal of bilateral breast prosthesis under general, balanced anesthesia, with a size three laryngeal mask. The balloon was inflated with 30 mL of air. After the first postoperative hour, she developed decreased sensation and pain in the oropharynx and posterior two thirds of the tongue, which evolved for loss of taste in the next 24 hours. A tentative diagnosis of lingual nerve neuropraxis secondary to the use of the laryngeal mask was made. After three weeks, her symptoms subsided. CONCLUSION: Although complications after the use of the laryngeal mask airway are rare, they do occur, and neuropraxis of the lingual nerve is one of them. The diagnosis is clinical and it has a good outcome, with resolution of the symptoms within a few weeks or months. © Sociedade Brasileira de Anestesiologia, 2007.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In spontaneously breathing cardiac patients, pulmonary artery pressure (PAP) can be accurately estimated from the transthoracic Doppler study of pulmonary artery and tricuspid regurgitation blood flows. In critically ill patients on mechanical ventilation for acute lung injury, the interposition of gas between the probe and the heart renders the transthoracic approach problematic. This study was aimed at determining whether the transesophageal approach could offer an alternative. METHODS: Fifty-one consecutive sedated and ventilated patients with severe hypoxemia (arterial oxygen tension/fraction of inspired oxygen < 300) were prospectively studied. Mean PAP measured from the pulmonary artery catheter was compared with several indices characterizing pulmonary artery blood flow assessed using transesophageal echocardiography: preejection time, acceleration time, ejection duration, preejection time on ejection duration ratio, and acceleration time on ejection duration ratio. In a subgroup of 20 patients, systolic PAP measured from the pulmonary artery catheter immediately before withdrawal was compared with Doppler study of regurgitation tricuspid flow performed immediately after pulmonary artery catheter withdrawal using either the transthoracic or the transesophageal approach. RESULTS: Weak and clinically irrelevant correlations were found between mean PAP and indices of pulmonary artery flow. A statistically significant and clinically relevant correlation was found between systolic PAP and regurgitation tricuspid flow. In 3 patients (14%), pulmonary artery pressure could not be assessed echocardiographically. CONCLUSIONS: In hypoxemic patients on mechanical ventilation, mean PAP cannot be reliably estimated from indices characterizing pulmonary artery blood flow. Systolic PAP can be estimated from regurgitation tricuspid flow using either transthoracic or transesophageal approach. © 2008 American Society of Anesthesiologists, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objectives: Glass ampoules have been widely used in packaging injection drugs. Glass has important characteristics that allow it to be widely used in fabrication of recipients for drugs and other sterile substances. However, contamination of solutions with glass microparticles on breaking open glass ampoules, the presence of metals, percutaneous injury, and biological contamination justify the need of educational materials to orient the manipulation of ampoules. Contents: Glass microparticles generated in the snap-opening of ampoules, as well as metals that contaminate their contents can be aspirated and injected through several routes. Exogenous contaminations by glass and metals can reach several sites in the organism. They trigger organic reactions that may give rise to injuries. Opening ampoules can expose professionals to the risk of percutaneous injuries. These lesions increase the biological risk as they are the gateway for viruses and bacteria. Ampoules opening systems (VIBRAC and OPC) have been developed to reduce the incidence of such accidents. Alternative materials to glass may represent an interesting strategy to increase safety. The use of prefilled syringes may represent an evolution regarding safety. Conclusions: Team training and information provided by the pharmaceutical industry on the use of ampoules are fundamental in the prophylaxis of accidents and contaminations. The search for safer materials to replace glass is also important. © 2011 Elsevier Editora Ltda.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Estudos Linguísticos - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)