971 resultados para ACOUSTIC REFLEX


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Impaired baroreflex sensitivity in diabetes is well described and has been attributed to autonomic diabetic neuropathy. In the present study conducted on acute (10-20 days) streptozotocin (STZ)-induced diabetic rats we examined: 1) cardiac baroreflex sensitivity, assessed by the slope of the linear regression between phenylephrine- or sodium nitroprusside-induced changes in arterial pressure and reflex changes in heart rate (HR) in conscious rats; 2) aortic baroreceptor function by means of the relationship between systolic arterial pressure and aortic depressor nerve (ADN) activity, in anesthetized rats, and 3) bradycardia produced by electrical stimulation of the vagus nerve or by the iv injection of methacholine in anesthetized animals. Reflex bradycardia (-1.4 ± 0.1 vs -1.7 ± 0.1 bpm/mmHg) and tachycardia (-2.1 ± 0.3 vs -3.0 ± 0.2 bpm/mmHg) were reduced in the diabetic group. The gain of the ADN activity relationship was similar in control (1.7 ± 0.1% max/mmHg) and diabetic (1.5 ± 0.1% max/mmHg) animals. The HR response to vagal nerve stimulation with 16, 32 and 64 Hz was 13, 16 and 14% higher, respectively, than the response of STZ-treated rats. The HR response to increasing doses of methacholine was also higher in the diabetic group compared to control animals. Our results confirm the baroreflex dysfunction detected in previous studies on short-term diabetic rats. Moreover, the normal baroreceptor function and the altered HR responses to vagal stimulation or methacholine injection suggest that the efferent limb of the baroreflex is mainly responsible for baroreflex dysfunction in this model of diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic attenuation coefficient, wave propagation speed and integrated backscatter coefficient (IBC) of human coronary arteries were measured in vitro over the -6 dB frequency bandwidth (36 to 67 MHz) of a focused ultrasound transducer (50 MHz, focal distance 5.7 mm, f/number 1.7). Corrections were made for diffraction effects. Normal and diseased coronary artery sub-samples (N = 38) were obtained from 10 individuals at autopsy. The measured mean ± SD of the wave speed (average over the entire vessel wall thickness) was 1581.04 ± 53.88 m/s. At 50 MHz, the average attenuation coefficient was 4.99 ± 1.33 dB/mm with a frequency dependence term of 1.55 ± 0.18 determined over the 36- to 67-MHz frequency range. The IBC values were: 17.42 ± 13.02 (sr.m)-1 for thickened intima, 11.35 ± 6.54 (sr.m)-1 for fibrotic intima, 39.93 ± 50.95 (sr.m)-1 for plaque, 4.26 ± 2.34 (sr.m)-1 for foam cells, 5.12 ± 5.85 (sr.m)-1 for media and 21.26 ± 31.77 (sr.m)-1 for adventitia layers. The IBC results indicate the possibility for ultrasound characterization of human coronary artery wall tissue layer, including the situations of diseased arteries with the presence of thickened intima, fibrotic intima and plaque. The mean IBC normalized with respect to the mean IBC of the media layer seems promising for use as a parameter to differentiate a plaque or a thickened intima from a fibrotic intima.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visceral afferents send information via cranial nerves to the nucleus tractus solitarius (NTS). The NTS is the initial step of information processing that culminates in homeostatic reflex responses. Recent evidence suggests that strong afferent synaptic responses in the NTS are most often modulated by depression and this forms a basic principle of central integration of these autonomic pathways. The visceral afferent synapse is uncommonly powerful at the NTS with large unitary response amplitudes and depression rather than facilitation at moderate to high frequencies of activation. Substantial signal depression occurs through multiple mechanisms at this very first brainstem synapse onto second order NTS neurons. This review highlights new approaches to the study of these basic processes featuring patch clamp recordings in NTS brain slices and optical techniques with fluorescent tracers. The vanilloid receptor agonist, capsaicin, distinguishes two classes of second order neurons (capsaicin sensitive or capsaicin resistant) that appear to reflect unmyelinated and myelinated afferent pathways. The differences in cellular properties of these two classes of NTS neurons indicate clear functional differentiation at both the pre- and postsynaptic portions of these first synapses. By virtue of their position at the earliest stage of these pathways, such mechanistic differences probably impart important differentiation in the performance over the entire reflex pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first minutes of the time course of cardiopulmonary reflex control evoked by lower body negative pressure (LBNP) in patients with hypertensive cardiomyopathy have not been investigated in detail. We studied 15 hypertensive patients with left ventricular dysfunction (LVD) and 15 matched normal controls to observe the time course response of the forearm vascular resistance (FVR) during 3 min of LBNP at -10, -15, and -40 mmHg in unloading the cardiopulmonary receptors. Analysis of the average of 3-min intervals of FVR showed a blunted response of the LVD patients at -10 mmHg (P = 0.03), but a similar response in both groups at -15 and -40 mmHg. However, using a minute-to-minute analysis of the FVR at -15 and -40 mmHg, we observed a similar response in both groups at the 1st min, but a marked decrease of FVR in the LVD group at the 3rd min of LBNP at -15 mmHg (P = 0.017), and -40 mmHg (P = 0.004). Plasma norepinephrine levels were analyzed as another neurohumoral measurement of cardiopulmonary receptor response to LBNP, and showed a blunted response in the LVD group at -10 (P = 0.013), -15 (P = 0.032) and -40 mmHg (P = 0.004). We concluded that the cardiopulmonary reflex response in patients with hypertensive cardiomyopathy is blunted at lower levels of LBNP. However, at higher levels, the cardiopulmonary reflex has a normal initial response that decreases progressively with time. As a consequence of the time-dependent response, the cardiopulmonary reflex response should be measured over small intervals of time in clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute otitis media (AOM) is the most prevalent bacterial infection among children. Tympanometry and spectral gradient acoustic reflectometry (SG-AR) are adjunctive diagnostic tools to pneumatic otoscopy. The aim was to investigate the diagnostic accuracy and success rates of tympanometry and SG-AR performed by physicians and nurses. The study populations comprised 515 (I-II), 281 (III), and 156 (IV) outpatients (6-35 months). Physicians performed 4246 tympanometric (I) and SG-AR (II) examinations. Nurses performed 1782 (III) and 753 (IV) examinations at symptomatic and asymptomatic visits, respectively. Pneumatic otoscopy by the physician was the diagnostic standard. The accuracy of test results by physicians or nurses (I-IV) and the proportion of visits with accurate exclusive test results from both ears (III-IV) were analyzed. Type B tympanogram and SG-AR level 5 (<49˚) predicted middle ear effusion (MEE). At asymptomatic visits, type A and C1 tympanograms (peak pressure > -200 daPa) and SG-AR level 1 (>95˚) indicated healthy middle ear. Negative predictive values of type A and C1 tympanograms by nurses in excluding AOM at symptomatic and MEE at asymptomatic visits were 94% and 95%, respectively. Nurses obtained type A or C1 tympanogram from both ears at 94/459 (20%) and 81/196 (41%) of symptomatic and asymptomatic visits, respectively. SG-AR level 1 was rarely obtained from both ears. Type A and C1 tympanograms were accurate in excluding AOM at symptomatic and MEE at asymptomatic visits. However, nurses obtained these tympanograms from both ears only at one fifth of symptomatic visits and less than half of asymptomatic visits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of exercise training on cardiovascular and autonomic functions were investigated in female rats. After an aerobic exercise training period (treadmill: 5 days/week for 8 weeks), conscious female Wistar (2 to 3 months) sedentary (S, N = 7) or trained rats (T, N = 7) were cannulated for direct arterial pressure (AP) recording in the non-ovulatory phases. Vagal (VT) and sympathetic tonus (ST) were evaluated by vagal (atropine) and sympathetic (propranolol) blockade. Baroreflex sensitivity was evaluated by the heart rate responses induced by AP changes. Cardiopulmonary reflex was measured by the bradycardic and hypotensive responses to serotonin. Resting bradycardia was observed in T (332 ± 7 bpm) compared with S animals (357 ± 10 bpm), whereas AP did not differ between groups. T animals exhibited depressed VT and ST (32 ± 7 and 15 ± 4 bpm) compared to S animals (55 ± 5 and 39 ± 10 bpm). The baroreflex and cardiopulmonary bradycardic responses were lower in T (-1.01 ± 0.27 bpm/mmHg and -17 ± 6 bpm) than in the S group (-1.47 ± 0.3 bpm/mmHg and -41 ± 9 bpm). Significant correlations were observed between VT and baroreflex (r = -0.72) and cardiopulmonary (r = -0.76) bradycardic responses. These data show that exercise training in healthy female rats induced resting bradycardia that was probably due to a reduced cardiac ST. Additionally, trained female rats presented attenuated bradycardic responses to baro- and cardiopulmonary receptor stimulation that were associated, at least in part, with exercise training-induced cardiac vagal reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We determined the sympathetic and parasympathetic control of heart rate (HR) and the sensitivity of the cardiopulmonary receptors after selective carotid and aortic denervation. We also investigated the participation of the autonomic nervous system in the Bezold-Jarish reflex after selective removal of aortic and carotid baroreceptors. Male Wistar rats (220-270 g) were divided into three groups: control (CG, N = 8), aortic denervation (AG, N = 5) and carotid denervation (CAG, N = 9). AG animals presented increased arterial pressure (12%) and HR (11%) compared with CG, while CAG animals presented a reduction in arterial pressure (16%) and unchanged HR compared with CG. The sequential blockade of autonomic effects by atropine and propranolol indicated a reduction in vagal function in CAG (a 50 and 62% reduction in vagal effect and tonus, respectively) while AG showed an increase of more than 100% in sympathetic control of HR. The Bezold-Jarish reflex was evaluated using serotonin, which induced increased bradycardia and hypotension in AG and CAG, suggesting that the sensitivity of the cardiopulmonary reflex is augmented after selective denervation. Atropine administration abolished the bradycardic responses induced by serotonin in all groups; however, the hypotensive response was still increased in AG. Although the responses after atropine were lower than the responses before the drug, indicating a reduction in vagal outflow after selective denervation, our data suggest that both denervation procedures are associated with an increase in sympathetic modulation of the vessels, indicating that the sensitivity of the cardiopulmonary receptors was modulated by baroreceptor fibers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Activation of 5-hydroxytryptamine (5-HT) 5-HT1A, 5-HT2C, 5-HT3, and 5-HT7 receptors modulates the excitability of cardiac vagal motoneurones, but the precise role of 5-HT2A/2B receptors in these phenomena is unclear. We report here the effects of intracisternal (ic) administration of selective 5-HT2A/2B antagonists on the vagal bradycardia elicited by activation of the von Bezold-Jarisch reflex with phenylbiguanide. The experiments were performed on urethane-anesthetized male Wistar rats (250-270 g, N = 7-9 per group). The animals were placed in a stereotaxic frame and their atlanto-occipital membrane was exposed to allow ic injections. The rats received atenolol (1 mg/kg, iv) to block the sympathetic component of the reflex bradycardia; 20-min later, the cardiopulmonary reflex was induced with phenylbiguanide (15 µg/kg, iv) injected at 15-min intervals until 3 similar bradycardias were obtained. Ten minutes after the last pre-drug bradycardia, R-96544 (a 5-HT2A antagonist; 0.1 µmol/kg), SB-204741 (a 5-HT2B antagonist; 0.1 µmol/kg) or vehicle was injected ic. The subsequent iv injections of phenylbiguanide were administered 5, 20, 35, and 50 min after the ic injection. The selective 5-HT2A receptor antagonism attenuated the vagal bradycardia and hypotension, with maximal effect at 35 min after the antagonist (pre-drug = -200 ± 11 bpm and -42 ± 3 mmHg; at 35 min = -84 ± 10 bpm and -33 ± 2 mmHg; P < 0.05). Neither the 5-HT2B receptor antagonists nor the vehicle changed the reflex. These data suggest that central 5-HT2A receptors modulate the central pathways of the parasympathetic component of the von Bezold-Jarisch reflex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Functional MRI (fMRI) resting-state experiments are aimed at identifying brain networks that support basal brain function. Although most investigators consider a ‘resting-state’ fMRI experiment with no specific external stimulation, subjects are unavoidably under heavy acoustic noise produced by the equipment. In the present study, we evaluated the influence of auditory input on the resting-state networks (RSNs). Twenty-two healthy subjects were scanned using two similar echo-planar imaging sequences in the same 3T MRI scanner: a default pulse sequence and a reduced “silent” pulse sequence. Experimental sessions consisted of two consecutive 7-min runs with noise conditions (default or silent) counterbalanced across subjects. A self-organizing group independent component analysis was applied to fMRI data in order to recognize the RSNs. The insula, left middle frontal gyrus and right precentral and left inferior parietal lobules showed significant differences in the voxel-wise comparison between RSNs depending on noise condition. In the presence of low-level noise, these areas Granger-cause oscillations in RSNs with cognitive implications (dorsal attention and entorhinal), while during high noise acquisition, these connectivities are reduced or inverted. Applying low noise MR acquisitions in research may allow the detection of subtle differences of the RSNs, with implications in experimental planning for resting-state studies, data analysis, and ergonomic factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rat posterodorsal medial amygdala (MePD) links emotionally charged sensory stimuli to social behavior, and is part of the supramedullary control of the cardiovascular system. We studied the effects of microinjections of neuroactive peptides markedly found in the MePD, namely oxytocin (OT, 10 ng and 25 pg; n=6/group), somatostatin (SST, 1 and 0.05 μM; n=8 and 5, respectively), and angiotensin II (Ang II, 50 pmol and 50 fmol; n=7/group), on basal cardiovascular activity and on baroreflex- and chemoreflex-mediated responses in awake adult male rats. Power spectral and symbolic analyses were applied to pulse interval and systolic arterial pressure series to identify centrally mediated sympathetic/parasympathetic components in the heart rate variability (HRV) and arterial pressure variability (APV). No microinjected substance affected basal parameters. On the other hand, compared with the control data (saline, 0.3 µL; n=7), OT (10 ng) decreased mean AP (MAP50) after baroreflex stimulation and increased both the mean AP response after chemoreflex activation and the high-frequency component of the HRV. OT (25 pg) increased overall HRV but did not affect any parameter of the symbolic analysis. SST (1 μM) decreased MAP50, and SST (0.05 μM) enhanced the sympathovagal cardiac index. Both doses of SST increased HRV and its low-frequency component. Ang II (50 pmol) increased HRV and reduced the two unlike variations pattern of the symbolic analysis (P<0.05 in all cases). These results demonstrate neuropeptidergic actions in the MePD for both the increase in the range of the cardiovascular reflex responses and the involvement of the central sympathetic and parasympathetic systems on HRV and APV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Industrial, electrical power generation, and transportation systems, to name but a few, rely heavily on power electronics to control and convert electrical power. Each of these systems, when encountering an unexpected failure, can cause significant financial losses, or even an emergency. A condition monitoring system would help to alleviate these concerns, but for the time being, there is no generally accepted and widely adopted method for power electronics. Acoustic emission is used as a failure precursor in many applications, but it has not been studied in power electronics so far. In this doctoral dissertation, observations of acoustic emission in power semiconductor components are presented. The acoustic emissions are caused by the switching operation and failure of power transistors. Three types of acoustic emission are observed. Furthermore, aspects related to the measurement and detection of acoustic phenomena are discussed. These include sensor performance and mechanical construction of experimental setups. The results presented in this dissertation are the outset of a research program where it will be determined whether an acoustic-emission-based condition monitoring method can be developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La version intégrale de ce mémoire est disponible uniquement pour consultation individuelle à la Bibliothèque de musique de l ’Université de Montréal (www.bib.umontreal.ca/MU).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Une des théories actuellement prépondérante pour expliquer le déclin cognitif observé chez les personnes âgées est une perte généralisée de la fonction inhibitrice. En revanche, de plus en plus d’études révèlent un maintien et même un gain sur le plan émotionnel chez les âgés. Afin de caractériser l’effet de l’âge sur la fonction inhibitrice et sur les émotions, nous avons utilisé le paradigme bien connu du réflexe acoustique de sursaut et de son inhibition par le prépulse, un phénomène reconnu comme reflétant le filtrage sensorimoteur, soit une mesure pré-attentionnelle d’inhibition. Le réflexe acoustique de sursaut est une réponse du corps tout entier à un bruit fort et inattendu et a été mesuré via la magnitude et la latence du clignement des yeux. La présentation d’un son faible (prépulse) quelques millisecondes avant le bruit de sursaut réduit la réponse de sursaut. Deux groupes de participants (jeunes adultes et âgés) ont visionné des images plaisantes, neutres et déplaisantes issues du International Affective Picture System (IAPS), lesquelles étaient associées à des stimuli auditifs évaluant le réflexe acoustique de sursaut et son inhibition par le prépulse. Les résultats démontrent que le réflexe de sursaut est modulé différemment par les émotions chez les jeunes adultes et les âgés. Plus particulièrement, les adultes âgés ont un plus grand réflexe de sursaut que les jeunes adultes lorsqu’ils visionnent des images plaisantes et neutres. Le processus d’inhibition par le prépulse est également modulé différemment par les émotions chez les âgés et les jeunes adultes: les âgés ont une plus grande inhibition du réflexe de sursaut que les jeunes adultes lorsqu’ils visionnent des images plaisantes et déplaisantes, mais ils ne diffèrent pas des jeunes adultes pour les images neutres. Dans l’ensemble, les résultats obtenus ne sont pas compatibles avec une perte d’inhibition chez les adultes âgés, et supportent plutôt un biais émotionnel positif.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif: Cette thèse avait pour objectif principal la mise en oeuvre et la validation de la faisabilité, chez l'humain, du paradigme de modulation du réflexe acoustique de sursaut par un court silence (GPIAS) afin de l'utiliser comme mesure objective de l'acouphène. Pour ce faire, trois expériences ont été réalisées. L'expérience 1 avait pour objectif de valider l'inhibition du réflexe de sursaut par un court silence chez des participants humains normo-entendants (sans acouphène) lors de la présentation d'un bruit de fond centré en hautes et en basses fréquences afin de déterminer les paramètres optimaux du paradigme. L'expérience 2 avait pour objectif de valider la précision et la fidélité d'une méthode de caractérisation psychoacoustique de l'acouphène (appariement en intensité et en fréquence). Finalement, l'expérience 3 avait pour objectif d'appliquer le paradigme d'objectivation de l'acouphène par le réflexe de sursaut à des participants atteints d'acouphènes chroniques en utilisant les techniques développées lors des expériences 1 et 2. Méthodologie : L'expérience 1 incluait 157 participants testés dans l'une des conditions de durée du court silence (5, 25, 50, 100, 200 ms) et dans l'un des deux paradigmes (court silence à l'intérieur du bruit de fond ou suivant celui-ci) à l'aide de bruits de fond en hautes et en basses fréquences. L'expérience 2 incluait deux groupes de participants avec acouphène, l'un musicien (n=16) et l'autre sans expérience musicale (n=16) ainsi qu'un groupe de simulateur sans acouphène (n=18). Ils tous ont été évalués sur leur capacité d'appariement en fréquence et en intensité de leur acouphène. Les mesures ont été reprises chez un sous-groupe de participants plusieurs semaines plus tard. L'expérience 3 incluait 15 participants avec acouphène et 17 contrôles évalués à l'aide du paradigme d'inhibition du réflexe de sursaut à l'aide d'un court silence (GPIAS). Les paramètres psychoacoustiques de l'acouphène ont également été mesurés. Toutes les mesures ont été reprises plusieurs mois plus tard chez un sous-groupe de participants. Résultats : Expérience 1 : le paradigme d'inhibition du réflexe acoustique de sursaut par un court silence est applicable chez l'humain normo-entendant. Expérience 2 : les mesures psychoacoustiques informatisées de l'acouphène incluant l'appariement en fréquence et en intensité sont des mesures précises et fidèles du percept de l'acouphène. Expérience 3 : un déficit d'inhibition au paradigme du GPIAS a été retrouvé chez le groupe de participants avec acouphène pour les bruits de fond en hautes et en basses fréquences au test et au retest. Les mesures d'appariement en fréquence ont révélé un acouphène dont la fréquence prédominante était d'environ 16 000 Hz chez la plupart des participants. Discussion : Il est possible d'appliquer le paradigme d'inhibition du réflexe acoustique de sursaut par un court silence à des participants humains atteints d'acouphène, tel qu'il est utilisé en recherche animale pour « objectiver » la présence d'acouphène. Toutefois, le déficit d'inhibition mesuré n'est pas spécifique à la fréquence de l'acouphène lorsque validé à partir des données d'appariement psychoacoustique. Nos résultats soulèvent des questions quant à l'interprétation originale du paradigme pour détecter la présence d'un acouphène chez les animaux.