975 resultados para 28-270
Resumo:
With the encouraging results of trawling experiments in Lake Victoria, it became apparent early in 1969 that commercial trawling on Lake Victoria might well be a viable economic enterprise. Considerable discussion about the optimum size and type of fishing vessel ensued, and the Fisheries Department decided to commission a number of different prototypes for comparative trials.
Resumo:
Theoretical investigations have been performed to analyze and compare the link power budget and power dissipation of a 28 Gb/s datacommunication system for data center switch scenarios using NRZ, PAM-4, CAP-16 and 16-QAM-OFDM modulation schemes. © 2012 IEEE.
Resumo:
Theoretical investigations have been carried out to analyze and compare the link power budget and power dissipation of non-return-to-zero (NRZ), pulse amplitude modulation-4 (PAM-4), carrierless amplitude and phase modulation-16 (CAP-16) and 16-quadrature amplitude modulation-orthogonal frequency division multiplexing (16-QAM-OFDM) systems for data center interconnect scenarios. It is shown that for multimode fiber (MMF) links, NRZ modulation schemes with electronic equalization offer the best link power budget margins with the least power dissipation for short transmission distances up to 200 m; while OOFDM is the only scheme which can support a distance of 300 m albeit with power dissipation as high as 4 times that of NRZ. For short single mode fiber (SMF) links, all the modulation schemes offer similar link power budget margins for fiber lengths up to 15 km, but NRZ and PAM-4 are preferable due to their system simplicity and low power consumption. For lengths of up to 30 km, CAP-16 and OOFDM are required although the schemes consume 2 and 4 times as much power respectively compared to that of NRZ. OOFDM alone allows link operation up to 35 km distances. © 1983-2012 IEEE.
Resumo:
An 850 nm vertical-cavity surface-emitting laser is modulated at 28 Gb/s using pulseamplitude modulation with three levels. Unequalized transmission over 100 m of OM3 MMF is demonstrated, with advantages over NRZ and PAM4 modulation. © 2012 OSA.
Resumo:
An 850 nm vertical-cavity surface-emitting laser is modulated at 28 Gb/s using pulseamplitude modulation with three levels. Unequalized transmission over 100 m of OM3 MMF is demonstrated, with advantages over NRZ and PAM4 modulation. © OSA 2012.
Resumo:
The development of transparent radio-frequency electronics has been limited, until recently, by the lack of suitable materials. Naturally thin and transparent graphene may lead to disruptive innovations in such applications. Here, we realize optically transparent broadband absorbers operating in the millimetre wave regime achieved by stacking graphene bearing quartz substrates on a ground plate. Broadband absorption is a result of mutually coupled Fabry-Perot resonators represented by each graphene-quartz substrate. An analytical model has been developed to predict the absorption performance and the angular dependence of the absorber. Using a repeated transfer-and-etch process, multilayer graphene was processed to control its surface resistivity. Millimetre wave reflectometer measurements of the stacked graphene-quartz absorbers demonstrated excellent broadband absorption of 90% with a 28% fractional bandwidth from 125-165 GHz. Our data suggests that the absorbers' operation can also be extended to microwave and low-terahertz bands with negligible loss in performance.
Resumo:
Daily intake and accumulation of microcystins (MCYSTs, MCs) in silver carp (Hypophthalmichthys molitrix) were investigated under lab conditions by feeding the fish exclusively with fresh toxic Microcystis bloom at a density of 6 x 10(9) algal cells L-1. The medial lethal dose (LD50) of microcystin-LR to silver carp was estimated to be 270 mu g kg(-1) body-weight, underlining its strong resistance to toxic Microcystis bloom. It can survive after being ingested with high doses of microcystins (about 10 mg kg(-1)) during the 28-days feeding experiment. Enzyme-linked immuno-sorbent assay results show that microcystin concentrations in muscle and liver are 1.57 +/- 0.31 mu g kg(-1) and 4.28 +/- 1.64 mg kg(-1) fresh weight. The former is much lower than the World Health Organization limit recommended for human consumption. These results suggest that silver carps can be widely used in cyanobacterial bloom control, and consumption of fish muscles is safe for human beings.
Resumo:
A flat, fully strain-relaxed Si0.72Ge0.28 thin film was grown on Si (1 0 0) substrate with a combination of thin low-temperature (LT) Ge and LT-Si0.72Ge0.28 buffer layers by ultrahigh vacuum chemical vapor deposition. The strain relaxation ratio in the Si0.72Ge0.28 film was enhanced up to 99% with the assistance of three-dimensional Ge islands and point defects introduced in the layers, which furthermore facilitated an ultra-low threading dislocation density of 5 x 10(4) cm (2) for the top SiGe film. More interestingly, no cross-hatch pattern was observed on the SiGe surface and the surface root-mean-square roughness was less than 2 nm. The temperature for the growth of LT-Ge layer was optimized to be 300 degrees C. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Zn1-xMgxS-based Schottky barrier ultraviolet (UV) photodetectors were fabricated using the molecular-beam-epitaxy (MBE) technique. The influence of Mg content on MBE-grown Zn1-xMgxS-based UV photodetectors has been investigated in details with a variety of experimental techniques, including photoresponse (PR), capacitance-voltage, deep level transient Fourier spectroscopy (DLTFS) and photoluminescence (PL). The room-temperature PR results show that the abrupt long-wavelength cutoffs covering 325, 305 295. and 270 nm with Mg contents of 16%, 44%, 57%, and 75% in the Zn1-xMgxS active layers, respectively, were achieved. But the responsivity and the external quantum efficiency exhibited a slight decrease with the Mg content increasing. In good agreement with the PR results, both of the integrated intensity of the PL spectra obtained from Zn1-xMgxS thin films with different Mg compositions (x = 31% and 52%, respectively) and the DLTFS spectra obtained from Zn1-xMgxS-based (x = 5% and 45%, respectively) UV photodetector samples clearly revealed a significant concentration increase of the non-radiative deep traps with increasing Mg containing in the ZnMgS active layers. Our experimental results also indicate that the MBE-grown ZnMgS-based photodetectors can offer the promising characteristics for the detection of short-wavelength UV radiation. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
于G批量导入至Hzhangdi
Resumo:
于G批量导入至Hzhangdi