925 resultados para 21-point running mean
Resumo:
We report an experimental study of a new type of turbulent flow that is driven purely by buoyancy. The flow is due to an unstable density difference, created using brine and water, across the ends of a long (length/diameter=9) vertical pipe. The Schmidt number Sc is 670, and the Rayleigh number (Ra) based on the density gradient and diameter is about 108. Under these conditions the convection is turbulent, and the time-averaged velocity at any point is ‘zero’. The Reynolds number based on the Taylor microscale, Reλ, is about 65. The pipe is long enough for there to be an axially homogeneous region, with a linear density gradient, about 6–7 diameters long in the midlength of the pipe. In the absence of a mean flow and, therefore, mean shear, turbulence is sustained just by buoyancy. The flow can be thus considered to be an axially homogeneous turbulent natural convection driven by a constant (unstable) density gradient. We characterize the flow using flow visualization and particle image velocimetry (PIV). Measurements show that the mean velocities and the Reynolds shear stresses are zero across the cross-section; the root mean squared (r.m.s.) of the vertical velocity is larger than those of the lateral velocities (by about one and half times at the pipe axis). We identify some features of the turbulent flow using velocity correlation maps and the probability density functions of velocities and velocity differences. The flow away from the wall, affected mainly by buoyancy, consists of vertically moving fluid masses continually colliding and interacting, while the flow near the wall appears similar to that in wall-bound shear-free turbulence. The turbulence is anisotropic, with the anisotropy increasing to large values as the wall is approached. A mixing length model with the diameter of the pipe as the length scale predicts well the scalings for velocity fluctuations and the flux. This model implies that the Nusselt number would scale as Ra1/2Sc1/2, and the Reynolds number would scale as Ra1/2Sc−1/2. The velocity and the flux measurements appear to be consistent with the Ra1/2 scaling, although it must be pointed out that the Rayleigh number range was less than 10. The Schmidt number was not varied to check the Sc scaling. The fluxes and the Reynolds numbers obtained in the present configuration are much higher compared to what would be obtained in Rayleigh–Bénard (R–B) convection for similar density differences.
Resumo:
We present an extensive study of Mott insulator (MI) and superfluid (SF) shells in Bose-Hubbard (BH) models for bosons in optical lattices with harmonic traps. For this we apply the inhomogeneous mean-field theory developed by Sheshadri et al. Phys. Rev. Lett. 75, 4075 (1995)]. Our results for the BH model with one type of spinless bosons agree quantitatively with quantum Monte Carlo simulations. Our approach is numerically less intensive than such simulations, so we are able to perform calculations on experimentally realistic, large three-dimensional systems, explore a wide range of parameter values, and make direct contact with a variety of experimental measurements. We also extend our inhomogeneous mean-field theory to study BH models with harmonic traps and (a) two species of bosons or (b) spin-1 bosons. With two species of bosons, we obtain rich phase diagrams with a variety of SF and MI phases and associated shells when we include a quadratic confining potential. For the spin-1 BH model, we show, in a representative case, that the system can display alternating shells of polar SF and MI phases, and we make interesting predictions for experiments in such systems.
Resumo:
We consider the problem of characterizing the minimum average delay, or equivalently the minimum average queue length, of message symbols randomly arriving to the transmitter queue of a point-to-point link which dynamically selects a (n, k) block code from a given collection. The system is modeled by a discrete time queue with an IID batch arrival process and batch service. We obtain a lower bound on the minimum average queue length, which is the optimal value for a linear program, using only the mean (λ) and variance (σ2) of the batch arrivals. For a finite collection of (n, k) codes the minimum achievable average queue length is shown to be Θ(1/ε) as ε ↓ 0 where ε is the difference between the maximum code rate and λ. We obtain a sufficient condition for code rate selection policies to achieve this optimal growth rate. A simple family of policies that use only one block code each as well as two other heuristic policies are shown to be weakly optimal in the sense of achieving the 1/ε growth rate. An appropriate selection from the family of policies that use only one block code each is also shown to achieve the optimal coefficient σ2/2 of the 1/ε growth rate. We compare the performance of the heuristic policies with the minimum achievable average queue length and the lower bound numerically. For a countable collection of (n, k) codes, the optimal average queue length is shown to be Ω(1/ε). We illustrate the selectivity among policies of the growth rate optimality criterion for both finite and countable collections of (n, k) block codes.
Resumo:
A controlled laboratory experiment was carried out on forty Indian male college students for evaluating the effect of indoor thermal environment on occupants' response and thermal comfort. During experiment, indoor temperature varied from 21 degrees C to 33 degrees C, and the variables like relative humidity, airflow, air temperature and radiant temperature were recorded along with subject's physiological parameters (skin (T-sk) and oral temperature (T-c)) and subjective thermal sensation responses (TSV). From T-sk and T-c, body temperature (T-b) was evaluated. Subjective Thermal Sensation Vote (TSV) was recorded using ASHRAE 7-point scale. In PMV model, Fanger's T-sk equation was used to accommodate adaptive response. Step-wise regression analysis result showed T-b was better predictor of TSV than T-sk and T-c. Regional skin temperature response, suppressed sweating without dipping, lower sweating threshold temperature and higher cutaneous threshold for sweating were observed as thermal adaptive responses. These adaptive responses cannot be considered in PMV model. To incorporate subjective adaptive response, mean skin temperature (T-sk) is considered in dry heat loss calculation. Along with these, PMV-model and other two methodologies are adopted to calculate PMV values and results are compared. However, recent literature is limited to measure the sweat rate in Indians and consideration of constant Ersw in PMV model needs to be corrected. Using measured T-sk in PMV model (Method(1)), thermal comfort zone corresponding to 0.5 <= PMV <= 0.5 was evaluated as (22.46-25.41) degrees C with neutral temperature of 23.91 degrees C, similarly while using TSV response, wider comfort zone was estimated as (23.25-26.32) degrees C with neutral temperature at 24.83 degrees C, which was further increased to with TSV-PPDnew, relation. It was observed that PMV-model overestimated the actual thermal response. Interestingly, these subjects were found to be less sensitive to hot but more sensitive to cold. A new TSV-PPD relation (PPDnew) was obtained from the population distribution of TSV response with an asymmetric distribution of hot-cold thermal sensation response from Indians. The calculations of human thermal stress according to steady state energy balance models used on PMV model seem to be inadequate to evaluate human thermal sensation of Indians. Relevance to industry: The purpose of this paper is to estimate thermal comfort zone and optimum temperature for Indians. It also highlights that PMV model seems to be inadequate to evaluate subjective thermal perception in Indians. These results can be used in feedback control of HVAC systems in residential and industrial buildings. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Water-tert-butyl alcohol (TBA) binary mixture exhibits a large number of thermodynamic and dynamic anomalies. These anomalies are observed at surprisingly low TBA mole fraction, with x(TBA) approximate to 0.03-0.07. We demonstrate here that the origin of the anomalies lies in the local structural changes that occur due to self-aggregation of TBA molecules. We observe a percolation transition of the TBA molecules at x(TBA) approximate to 0.05. We note that ``islands'' of TBA clusters form even below this mole fraction, while a large spanning cluster emerges above that mole fraction. At this percolation threshold, we observe a lambda-type divergence in the fluctuation of the size of the largest TBA cluster, reminiscent of a critical point. Alongside, the structure of water is also perturbed, albeit weakly, by the aggregation of TBA molecules. There is a monotonic decrease in the tetrahedral order parameter of water, while the dipole moment correlation shows a weak nonlinearity. Interestingly, water molecules themselves exhibit a reverse percolation transition at higher TBA concentration, x(TBA) approximate to 0.45, where large spanning water clusters now break-up into small clusters. This is accompanied by significant divergence of the fluctuations in the size of largest water cluster. This second transition gives rise to another set of anomalies around. Both the percolation transitions can be regarded as manifestations of Janus effect at small molecular level. (C) 2014 AIP Publishing LLC.
Resumo:
The GW approximation to the electron self-energy has become a standard method for ab initio calculation of excited-state properties of condensed-matter systems. In many calculations, the G W self-energy operator, E, is taken to be diagonal in the density functional theory (DFT) Kohn-Sham basis within the G0 W0 scheme. However, there are known situations in which this diagonal Go Wo approximation starting from DFT is inadequate. We present two schemes to resolve such problems. The first, which we called sc-COHSEX-PG W, involves construction of an improved mean field using the static limit of GW, known as COHSEX (Coulomb hole and screened exchange), which is significantly simpler to treat than GW W. In this scheme, frequency-dependent self energy E(N), is constructed and taken to be diagonal in the COHSEX orbitals after the system is solved self-consistently within this formalism. The second method is called off diagonal-COHSEX G W (od-COHSEX-PG W). In this method, one does not self-consistently change the mean-field starting point but diagonalizes the COHSEX Hamiltonian within the Kohn-Sham basis to obtain quasiparticle wave functions and uses the resulting orbitals to construct the G W E in the diagonal form. We apply both methods to a molecular system, silane, and to two bulk systems, Si and Ge under pressure. For silane, both methods give good quasiparticle wave functions and energies. Both methods give good band gaps for bulk silicon and maintain good agreement with experiment. Further, the sc-COHSEX-PGW method solves the qualitatively incorrect DFT mean-field starting point (having a band overlap) in bulk Ge under pressure.
Resumo:
[Es]Actualmente ninguna área científica es ajena a la revolución de la nanociencia; las nanopartículas atraen el interés de muchos investigadores desde el punto de vista de la ciencia fundamental y para sus aplicaciones tecnológicas. Las nanopartículas ofrecen la posibilidad de fabricar sensores que sean capaces de detectar desde un virus hasta concentraciones de substancias patógenas que no pueden ser detectadas por los métodos convencionales. Hoy en día existes 82 tratamientos contra el cáncer basadas en la utilización de nanopartículas y los materiales composite con nanopartículas se utilizan como medio de protección frente la radiación del rango de microondas. En la rama de ciencias ambientales, las nanopartículas metálicas sirven como materiales anticontaminantes. En este trabajo se ha estudiado la estructura y las propiedades magnéticas de las nanopartículas de FeNi preparadas mediante el método de explosión eléctrica de hilo. Con la técnica de Rayos–X(DRX) se ha determinado que las nanopartículas se cristalizan en un sistema cúbico FCC con un parámetro de celda de 3.596 Å, también, se ha obtenido el tamaño de dominio coherente que es de 35 nm. La muestra se ha sometido a un programa de temperatura controlada para seguir la evolución de la estructura cristalina y del tamaño del cristal, tanto en atmósfera oxidante como en vacío. Para el aprendizaje de los microscopios utilizados en este trabajo, se ha asistido al curso “Fundamentos de microscopia electrónica de barrido y microanálisis” impartido por SGIker de la UPV/EHU. Se han empleado los microscopios electrónicos SEM y TEM para obtener imágenes de gran resolución de la muestra y analizar su contenido elemental. Partiendo de las imágenes sacadas por el SEM se ha calculado el valor medio del tamaño de las partículas de la muestra, 58 nm. Mediante el Mastersizer 2000 se ha medido el tamaño de las partículas y/o agregados por método de difracción láser, disgregando la muestra todo lo posible hasta conseguir el tamaño medio que se aproxime al de una sola partícula, 100nm. Por último, para la caracterización magnética se ha servido del VSM que mide el momento magnético de una muestra cuando ésta vibra en presencia de un campo magnético estático, consiguiendo una imanación de saturación de 125 emu/g. Hemos fabricado y caracterizado las nanopartículas magnéticas de hierro-níquel y los resultados obtenidos han sido enviados a un congreso especializado de ciencia de materiales (ISMANAM - 2013, Italia).
Resumo:
The report describes the results of preliminary analyses of data obtained from a series of water temperature loggers sited at various distances (0.8 to 21.8 km) downstream of Kielder dam on the River North Tyne and in two natural tributaries. The report deals with three aspects of the water temperature records: An analysis of an operational aspect of the data sets for selected stations, a simple examination of the effects of impoundment upon water temperature at or close to the point of release, relative to natural river temperatures, and an examination of rate of change of monthly means of daily mean, maximum, minimum and range (maximum - minimum) with distance downstream of the point of release during 1983.
Resumo:
A hipotensão pós-exercício (HPE) é um fenômeno de relevância clínica, mas dúvidas persistem no tocante ao efeito do modo e da forma de execução (contínua vs. acumulada) do exercício aeróbio para sua manifestação, bem como o papel do controle autonômico cardíaco como mecanismo fisiológico associado à HPE. Assim, a presente tese objetivou: a) investigar a HPE induzida por sessões aeróbias de exercício isocalórico contínuo e acumulado; b) comparar as respostas de pressão arterial sistólica (PAS) e diastólica (PAD) após teste cardiopulmonar de exercício máximo (TCPE) em três modalidades; c) verificar a influência do modo de exercício e do controle autonômico cardíaco em repouso sobre a reativação vagal após TCPE. No primeiro estudo, 10 homens saudáveis (idade: 27,6 3,5 anos) realizaram TCPEs de corrida e ciclismo para medida do consumo de oxigênio de pico (VO2pico) e sessões contínuas (400 kcal) e acumuladas (2 x 200 kcal) de corrida e ciclismo à 75%VO2reserva. A PAS e PAD reduziram similarmente após exercício contínuo e acumulado (4,6 2,3 vs. 5,2 2,3 mmHg, 2,6 2,5 vs. 3,6 2,5 mmHg, respectivamente, P > 0,05). Porém, a corrida provocou maior declínio na PAS do que o ciclismo (P < 0.05). A atividade simpática (componente de baixa frequência, LF) e parassimpática (componente de alta frequência, HF) aumentou (P < 0,001) e diminuiu (P < 0,001) em relação à sessão controle, elevando o balanço simpato-vagal (razão LF:HF) (P < 0,001) que foi inversamente correlacionado ao ΔPAS e ΔPAD (r = -0,41 a -0,70; P < 0.05). No segundo e terceiro estudos, 20 homens saudáveis (idade: 21.2 3.0 anos) realizaram três TCPEs (ciclismo, caminhada e corrida). No segundo estudo, investigou-se a resposta aguda da PA, débito cardíaco (Q), resistência vascular periférica (RVP), sensibilidade do barorreflexo arterial (SBR), variabilidade da frequência cardíaca (VFC) e dispêndio energético durante 60 min após os TCPEs e sessão controle. Comparado ao controle, somente a corrida modalidade envolvendo maior dispêndio energético total (P < 0,001) - foi capaz de reduzir a PAS no pós-exercício (P < 0,001). Mudanças na RVP, SBR, LF, e razão LF:HF foram negativamente correlacionadas às variações na PAS (-0,69 a -0,91; P < 0,001) e PAD (-0,58 a -0,93; P ≤ 0,002). No terceiro estudo, examinou-se a reativação parassimpática após cada TCPE pela raiz quadrada da média do quadrado das diferenças entre intervalos R-R normais adjacentes em janelas de 30 s (rMSSD30s). Apesar da menor FCpico, VO2pico e dispêndio energético no ciclismo vs. caminhada e corrida (P < 0,001), a reativação parassimpática foi significativamente mais rápida após o ciclismo (P < 0,05). Outrossim, o Δ rMSSD30-180s foi positivamente correlacionado ao HF (rs = 0,90 a 0,93; P < 0,001) e negativamente correlacionado ao LF e a razão LF:HF medidos no repouso (rs = -0,73 a -0,79 e -0,86 a -0,90, respectivamente; P < 0,001). Em conclusão, a forma de execução do exercício aeróbio não interfere na magnitude da HPE, mas a HPE é dependente do modo ou o volume total de exercício. Os resultados também indicam que o padrão de recuperação do controle autonômico cardíaco pela análise espectral da VFC pode ter um papel importante na indução da HPE.