995 resultados para water exercise


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In topographically flat wetlands, where shallow water table and conductive soil may develop as a result of wet and dry seasons, the connection between surface water and groundwater is not only present, but perhaps the key factor dominating the magnitude and direction of water flux. Due to their complex characteristics, modeling waterflow through wetlands using more realistic process formulations (integrated surface-ground water and vegetative resistance) is an actual necessity. This dissertation focused on developing an integrated surface – subsurface hydrologic simulation numerical model by programming and testing the coupling of the USGS MODFLOW-2005 Groundwater Flow Process (GWF) package (USGS, 2005) with the 2D surface water routing model: FLO-2D (O’Brien et al., 1993). The coupling included the necessary procedures to numerically integrate and verify both models as a single computational software system that will heretofore be referred to as WHIMFLO-2D (Wetlands Hydrology Integrated Model). An improved physical formulation of flow resistance through vegetation in shallow waters based on the concept of drag force was also implemented for the simulations of floodplains, while the use of the classical methods (e.g., Manning, Chezy, Darcy-Weisbach) to calculate flow resistance has been maintained for the canals and deeper waters. A preliminary demonstration exercise WHIMFLO-2D in an existing field site was developed for the Loxahatchee Impoundment Landscape Assessment (LILA), an 80 acre area, located at the Arthur R. Marshall Loxahatchee National Wild Life Refuge in Boynton Beach, Florida. After applying a number of simplifying assumptions, results have illustrated the ability of the model to simulate the hydrology of a wetland. In this illustrative case, a comparison between measured and simulated stages level showed an average error of 0.31% with a maximum error of 2.8%. Comparison of measured and simulated groundwater head levels showed an average error of 0.18% with a maximum of 2.9%. The coupling of FLO-2D model with MODFLOW-2005 model and the incorporation of the dynamic effect of flow resistance due to vegetation performed in the new modeling tool WHIMFLO-2D is an important contribution to the field of numerical modeling of hydrologic flow in wetlands.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation focused on developing an integrated surface – subsurface hydrologic simulation numerical model by programming and testing the coupling of the USGS MODFLOW-2005 Groundwater Flow Process (GWF) package (USGS, 2005) with the 2D surface water routing model: FLO-2D (O’Brien et al., 1993). The coupling included the necessary procedures to numerically integrate and verify both models as a single computational software system that will heretofore be referred to as WHIMFLO-2D (Wetlands Hydrology Integrated Model). An improved physical formulation of flow resistance through vegetation in shallow waters based on the concept of drag force was also implemented for the simulations of floodplains, while the use of the classical methods (e.g., Manning, Chezy, Darcy-Weisbach) to calculate flow resistance has been maintained for the canals and deeper waters. A preliminary demonstration exercise WHIMFLO-2D in an existing field site was developed for the Loxahatchee Impoundment Landscape Assessment (LILA), an 80 acre area, located at the Arthur R. Marshall Loxahatchee National Wild Life Refuge in Boynton Beach, Florida. After applying a number of simplifying assumptions, results have illustrated the ability of the model to simulate the hydrology of a wetland. In this illustrative case, a comparison between measured and simulated stages level showed an average error of 0.31% with a maximum error of 2.8%. Comparison of measured and simulated groundwater head levels showed an average error of 0.18% with a maximum of 2.9%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polonium-210 and Lead-210 have been measured in the water column and on suspended particulate matter during the POLARSTERN cruise ARK-XXII/2. The data have been submitted to Pangaea following a Polonium-Lead intercalibration exercise organized by GEOTRACES, where the AWI lab results range within the data standard deviation from 10 participating labs. Polonium-210 and Lead-210 in the ocean can be used to identify the sources and sinks of suspended matter. In seawater, Polonium-210 (210Po) and Lead-210 (210Pb) are produced by stepwise radioactive decay of Uranium-238. 210Po (138 days half life) and 210Pb (22.3 years half life) have high affinities for suspended particles. Those radionuclides are present in dissolved form and adsorbed onto particles. Following adsorption onto particle surfaces, 210Po especially is transported into the interior of cells where it bonds to proteins. In this way, 210Po also accumulates in the food chain. 210Po is therefore considered to be a good tracer for POC, and traces particle export over a timescale of month. 210Pb (22.3 years half life) adsorbs preferably onto structural components of cells, biogenic silica and lithogenic particles, and is therefore a better tracer more rapidly sinking matter. Our goal during ARK XXII/2 was to trace pathways of particulate and dissolved matter leaving the Siberian Shelf. The pathways of particulate and dissolved matter will be followed by the combined use of 210Po and 234Th as a tracer pair (and perhaps 210Pb) for particle flux (Cai, P.; Rutgers van der Loeff, MM (2008) doi:10.1594/PANGAEA.708354). This information gathered from the water column will be complemented with the results of the 210Po-210Pb study in sea ice (Camara-Mor, P, Instituto de Ciencias del Mar-SCIC, Barcelona, Spain) to provide a more thorough picture of particle transport from the shelf to the open sea and from surface to depth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to determine if ice slurry ingestion improved self-paced intermittent exercise in the heat. After a familiarisation session, 12 moderately trained males (30.4 ± 3.4 year, 1.8 ± 0.1 cm, 73.5 ± 14.3 kg, inline imageO2max 58.5 ± 8.1 mL/kg/min) completed two separate 31 min self-paced intermittent protocols on a non-motorised treadmill in 30.9 ± 0.9 °C, 41.1 ± 4.0% RH. Thirty minutes prior to exercise, participants consumed either 7.5 g/kg ice slurry (0.1 ± 0.1 °C) (ICE) or 7.5 g/kg water (23.4 ± 0.9 °C) (CONTROL). Despite reductions in Tc (ΔTc: −0.51 ± 0.3 °C, P < 0.05) and thermal sensation prior to exercise, ICE did not enhance self-paced intermittent exercise compared to CONTROL. The average speed during the walk (CONTROL: 5.90 ± 1.0 km, ICE: 5.90 ± 1.0 km), jog (CONTROL: 8.89 ± 1.7 km, ICE: 9.11 ± 1.5 km), run (CONTROL: 12.15 ± 1.7 km, ICE: 12.54 ± 1.5 km) and sprint (CONTROL: 17.32 ± 1.3 km, ICE: 17.18 ± 1.4 km) was similar between conditions (P > 0.05). Mean Tsk, Tb, blood lactate, heart rate and RPE were similar between conditions (P > 0.05). The findings suggest that lowering Tc prior to self-paced intermittent exercise does not translate into an improved performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Passive sampling devices (PS) are widely used for pollutant monitoring in water, but estimation of measurement uncertainties by PS has seldom been undertaken. The aim of this work was to identify key parameters governing PS measurements of metals and their dispersion. We report the results of an in situ intercomparison exercise on diffusive gradient in thin films (DGT) in surface waters. Interlaboratory uncertainties of time-weighted average (TWA) concentrations were satisfactory (from 28% to 112%) given the number of participating laboratories (10) and ultra-trace metal concentrations involved. Data dispersion of TWA concentrations was mainly explained by uncertainties generated during DGT handling and analytical procedure steps. We highlight that DGT handling is critical for metals such as Cd, Cr and Zn, implying that DGT assembly/dismantling should be performed in very clean conditions. Using a unique dataset, we demonstrated that DGT markedly lowered the LOQ in comparison to spot sampling and stressed the need for accurate data calculation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presenting acoustic information has become increasingly interesting for technique training and control in various sports. In elite rowing, acoustic feedback is a new and promising application to optimize the boat's forward motion. This paper describes the potential of acoustic information which represents the movement-relevant information on the boat's forward motion for rowing and its implementation as online acoustic feedback during on-water training sessions. The first significant results were encouraging and support the intention to implement the acoustic information regularly into training processes for elite athletes. © Faculty of Education. University of Alicante.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method has been recently proposed to assess acute hydration status in humans; however, several questions remain regarding its reliability, validity, and practicality. Objective: Establish reliability of a simple method to assess euhydration, that is, to analyze whether this method can be used as a consistent indicator of a person´s hydration status. In addition, the study sought to assess the effect exercise has on urine volume when euhydration is maintained and a standardized volume of water is ingested. Methods: Five healthy physically active men and five healthy physically active women, 22.5 ± 2.3 years of age (mean ± standard deviation) reported to the laboratory after fasting for 10 hours or more on three occasions, each one week apart. During the two identical resting euhydration conditions (EuA and EuB), participants remained seated for 45 minutes. During the exercise condition (EuExer), participants exercised intermittently in an environmental chamber (average temperature and relative humidity = 32 ± 3°C and 65 ± 7%, respectively) for a period of 45 minutes and drank water to offset loss due to sweating. The order of treatments was randomized. Upon finishing the treatment period, they ingested a volume of water equivalent to 1.43% body mass (BM) within 30 minutes. Urine was collected and measured henceforth every 30 minutes for 3 hours. Results: Urine volume eliminated during EuExer (1205 ± 399.5 ml) was not different from EuB (1072.2±413.1 ml) or EuA (1068 ± 382.87 ml) (p-value = 0.44). Both resting conditions were practically identical (p-value = 0.98) and presented a strong intraclass correlation (r = 0.849, p-value = 0.001). Conclusions: This method, besides simple, proved to be consistent in all conditions; therefore, it can be used with the certainty that measurements are valid and reliable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prolonged high-intensity training seems to result in increased systemic inflammation, which might explain muscle injury, delayed onset muscle soreness, and overtraining syndrome in athletes. Furthermore, an impaired immune function caused by strenuous exercise leads to the development of upper respiratory tract infections in athletes. Nutraceuticals might help counteract these performance-lowering effects. The use of nanotechnology is an interesting alternative to supply athletes with nutraceuticals, as many of these substances are insoluble in water and are poorly absorbed in the digestive tract. The present chapter starts with a brief review of the effects of exercise on immunity, followed by an analysis on how nutraceuticals such as omega-3 fatty acids, glutamine, BCAAs, or phytochemicals can counteract negative effects of strenuous exercise in athletes. Finally, how nanostructured delivery systems can constitute a new trend in enhancing bioavailability and optimizing the action of nutraceuticals will be discussed, using the example of food beverages.